Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muon beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electroweak $\mathrm{ALP}$ searches at a muon collider

A high-energy muon collider with center-of-mass energy around and above 10 TeV is also a vector boson fusion (VBF) machine, due to the significant virtual electroweak (EW) gauge boson content of high-energy muon beams. This feature, together with the clean environment, makes it an ideal collider to search for TeV-scale axion-like particles (ALP) coupling to Standard Model EW gauge bosons, which current and other future colliders have limited sensitivities to. We present detailed analyses of heavy ALP searches in both the VBF and associated production channels at a muon collider with different running benchmarks. We also show projected constraints on the ALP couplings in the effective field theory, including an operator with its coefficient not determined by the mixed Peccei-Quinn anomaly. We demonstrate that a muon collider could probe new ALP parameter space and push the sensitivities of the couplings between the ALP and EW gauge bosons by one order of magnitude compared to HL-LHC. The projected limits and search strategies for ALPs could also be applied to other types of resonances coupling to EW gauge bosons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alignment of the straw tracking detectors for the Fermilab Muon $g − 2$ experiment and systematic studies for a muon electric dipole moment measurement

The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the coming months. The final goal of the experiment is to determine the muon magnetic anomaly to a precision of 140 ppb. This level of precision will provide indirect evidence of new physics, if the central value agrees with the previously-measured value of the magnetic anomaly. Essential in reducing the systematic uncertainty, through measurements of the muon beam profile, are the in-vacuum straw tracking detectors. A crucial prerequisite in obtaining accurate distributions of the beam profile is the internal alignment of the tracking detectors, which is described in this thesis. As a result of this position calibration, the tracking efficiency has increased by 3%, while the track quality increased by 4%. This thesis also discusses an additional measurement that will be made using the tracking detectors: a search for an electric dipole moment (EDM) of the muon, through the direct detection of an oscillation in the average vertical angle of the electron from the muon decay. An observation of a muon EDM would be evidencemore » of new physics and would provide a new source of CP violation in the charged lepton sector. Essential in measuring the EDM are accurate and precise estimations of potential non-zero radial and longitudinal magnetic fields, which were estimated using the Run-1 data. In addition, a preliminary analysis using the Run-1 data was undertaken to estimate the available precision for the magnetic anomaly measurement using the tracking detectors.« less

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrinos from Stored Muons (nuSTORM)

The 2020 Update of the European Strategy for Particle Physics (ESPP) (see https://cds.cern.ch/record/2720129 ) recommended that muon beam R&D should be considered a high-priority future initiative and that a programme of experimentation be developed to determine the neutrino cross-sections required to extract the most physics from the DUNE and Hyper-K long-baseline experiments. The ENUBET and nuSTORM collaborations have begun to work within and alongside the CERN Physics Beyond Colliders study group and the international Muon Collider collaboration to carry out a joint, five-year R&D programme to deliver a detailed plan for the implementation of an infrastructure in which: (1) ENUBET and nuSTORM deliver the neutrino cross-section measurement programme identified in the ESPP and allow sensitive searches for physics beyond the Standard Model to be carried out; and in which (2) A 6D muon ionisation cooling experiment is delivered as part of the technology development programme defined by the international Muon Collider collaboration. This document summarises the status of development of the nuSTORM and 6D cooling experiments and identifies opportunities for collaboration in the development of the initiative outlined above.

43 PARTICLE ACCELERATORS↗

Towards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning

The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating μ + →e + γ decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR (μ + →e + γ) ≤ 4.2×10 –13 at 90% confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of 6×10 –14 . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG (7×10 7 μ + /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

The Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay μ+→e+γ: BR(μ+→e+γ) <4.2×10−13 at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of 6×10−14. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute (7×107 muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

physics beyond the Standard Model↗

New physics at the Muon (Synchrotron) Ion Collider: MuSIC for several scales

A Muon (Synchrotron) Ion Collider (MuSIC) can be the successor to the Electron-Ion Collider at Brookhaven National Laboratory, as well as the ideal demonstrator facility for a future multi-TeV Muon Collider. Besides its rich nuclear physics and Standard Model particle physics programs, in this work we show that the MuSIC with a TeV-scale muon beam offers also a unique opportunity to probe New Physics. In particular, the relevant searches have the potential to surpass current experimental limits and explore new regimes of the parameter space for a variety of Beyond the Standard Model scenarios including: lepton-flavor violating leptoquarks, muonphilic vector boson interactions, axion-like particles coupling to photons, and heavy sterile neutrinos. Depending on the particular case, the sensitivity of the searches in the MuSIC may span a wide range of energy scales, namely from sub-GeV particles to the few TeV New Physics mediators. Our analysis demonstrates that the MuSIC can strike a powerful chord in the search for New Physics, thanks to unique combination of features that amplify its capabilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A robust search for lepton flavour violating axions at Mu3e

We propose a search at Mu3e for lepton flavor violating axion(-like) particles in μ → 3e + a decays. By requiring an additional e+e− pair from internal conversion, one can circumvent the calibration challenges which plague the μ → e + a channel for axions lighter than 20 MeV. Crucially, the corresponding reduction in signal rate is to a large extent compensated for by Mu3e’s ability to resolve highly collimated tracks. For phase I of Mu3e, we project a sensitivity to decay constants as high as 6 × 109 GeV which probes uncharted parameter space in scenarios of axion dark matter. The sensitivity to axions which couple primarily to right-handed leptons can be further improved by leveraging the polarisation of the muon beam.

Knapen, Simon↗

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Mu2e experiment

The Mu2e experiment at Fermilab searches for the coherent, neutrino-less conversion of a μ − to e − in the Coulomb field of Al nuclei, that represents one of the cleanest Charged Lepton Flavor Violating (CLFV) processes for exploring Beyond the Standard Model (BSM) physics. Mu2e aims to improve previous sensitivity by four orders of magnitude, with a distinctive signature provided by identifying mono-energetic electrons with energy slightly below the muon rest mass. To reach this goal, the experiment will use the highest intensity pulsed muon beam in the world, with up to 6 × 1 0 9 stopped muons/sec. This is achieved using the Fermilab proton beam and the design and realization of a unique 25 m long superconducting solenoidal system. The high beam intensity relies upon minimizing beam losses in the slow extraction region, indicating an opportunity of using bent crystals for shadowing. A high-resolution straw tracker and a fast CsI crystal calorimeter identify the conversion electron. Both detectors are inserted behind the Stopping Target in the last solenoid section. A Cosmic Ray Veto covers a large part of the solenoids to suppress background produced by cosmic rays. In this paper, we report the details of the experimental layout, the construction status of the magnetic system and detectors, and a short description of the simulation and realization of the bent crystals. Performing crystal channeling in front of the first slow extraction septa will allow beam shadowing and largely reduce beam losses. •Charge Lepton Flavor Violation processes: μ − → e − conversion.•Large Superconducting Solenoid system.•High-Intensity beams•High precision detectors.•Crystal channeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MuFusE large-volume diamond anvil cell for exploring muon-catalyzed fusion at higher pressures and temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion (μCF) Experiment (MuFusE), enabling the compression and heating of deuterium–tritium (d–t) mixtures to pressures and temperatures needed to advance μCF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm 3 at liquid density, pressures up to 933 MPa and temperatures up to 400 K—benchmarks that significantly exceed previously reported limits for static d–t targets.

Kalow, J. D. [Acceleron Fusion, Inc., Cambridge, M↗

Operation of normal-conducting rf cavities in multi-Tesla magnetic fields for muon ionization cooling: A feasibility demonstration

Ionization cooling is the preferred method for producing bright muon beams. This cooling technique requires the operation of normal conducting, radio-frequency (rf) accelerating cavities within the multi-tesla fields of dc solenoid magnets. Under these conditions, cavities exhibit increased susceptibility to rf breakdown, which can damage cooling channel components and imposes limits on channel length and transmission efficiency. We report, for the first time, stable high-vacuum, normal-conducting cavity operation at gradients of 50 MV / m in an external magnetic field of three tesla, through the use of beryllium cavity elements. This eliminates a significant technical risk that has previously been inherent in ionization cooling channel designs.

43 PARTICLE ACCELERATORS↗

General signals for charged lepton flavor violating decays

We explore the most general phenomenology of charged lepton flavor violating (CLFV) decays of muon and tau leptons to the three body final states ($\bar{e}ee, \bar{μ}μμ, \bar{e}μμ, \bar{μ}μe, \bar{μ}ee, \bar{e}eμ$). By constructing a complete basis of operators at each dimension, we derive the most general amplitudes for these decay processes. By considering constraints from unitarity and Large Electron-Positron Collider (LEP), we show that operators of mass dimension 6 and 7 are the most likely to be observed in next generation experiments. Focusing on these dimensions, we compute the results of unpolarized (spin-averaged) decays parametrized in terms of the invariant masses of the daughter particles. We also compute the differential decay rates for polarized decays, in anticipation of the experimental search Mu3e, which expects to have a muon beam with ∼ 90% polarization, and the chiral Belle proposal, which aims to have a 70% polarized electron beam. To determine the extent to which the operators may be distinguished experimentally, we plot the differential distributions for each operator, showing that they leave only a few possible degenerate explanations. Through a statistical analysis, we estimate the number of events needed to break the degeneracies using the angular information. These results are adapted to treat ℓ → ℓ′⁢$v\bar{v}$, where the angular distribution of the outgoing charged lepton has enhanced distinguishing power. With many Standard Model extensions predicting these CLFV decays, these results will better enable upcoming searches to identify and/or constrain physics beyond the Standard Model.

phenomenology↗

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]↗

Analysis of Slow Spill Data for Mu2e

The Mu2e experiment requires a constant, relatively low intensity muon beam to produce data with high clarity, which can be achieved using slow extraction. Slow spills/extractions in the Delivery Ring involve contracting and expanding the stable region, which is bordered by the separatrix, of the beam pipe. While this does lower the beam intensity, it is very inconsistent. To help mitigate future inconsistencies, data from many trial spills (some including various magnet impulses to influence the beam intensity) was examined. This involved cutting low quality spills that have abnormal peak and integrated intensities, as well as spills with unusually low magnet ramping. Then, the remaining spills in the datasets were analyzed for trends within spills and across many spills. The findings from this analysis were then given to the FAN-C team to help them develop their simulations, as well as provide training data for their machine learning models that will use beam and impulse data to apply corrective impulses during future slow extractions.

Osborn, Thomas [Purdue U., West Lafayette]↗

Analysis of Samples from Asteroid Ryugu Returned by Hayabusa2

After returning to Earth in the winter of 2020, the samples from Cb-type asteroid Ryugu were stored under atmosphere-free conditions at the Extraterrestrial Materials Curation Center of ISAS/JAXA, and investigated for basic descriptions (sample imaging, weighing, etc.). They were distributed to six initial analysis teams in Japan in June 2021. The "Stone" team, in charge of analysis of coarse particles (>1 mm in size), conducted a series of analyses using a variety of techniques including reflectance spectra measurement, synchrotron-radiation three-dimensional elemental and mineralogical analysis, bulk elemental analysis using muon beam, Fe valence state measurement by XANES and Mössbauer spectroscopy, detailed mineralogical and petrological characterization by scanning and transmission electron microscopes. Physical and thermal properties of Ryiugu samples were measured to understand the response to shock and heating. In this talk, I would like to introduce summary of analysis results and what comes to be known about the formation and evolution of asteroid Ryugu.

Tomoki Nakamura↗

The Detectors of the Mu2e Experiment

The Mu2e experiment aims to test Charge Lepton Flavour Violation to an unprecedented level, enhancing the current sensitivity by four orders of magnitude for the neutrinoless conversion of muons into electrons. A series of graded solenoids convey an intense, pulsed muon beam to an aluminum target. The main detector components are a low mass straw drift tubes tracker, a pure Cesium Iodide calorimeter and an extruded plastic scintillator cosmic ray veto. Requirements, tests on prototypes and status of the production will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solving Critical Problems of the Muon Collider Higgs Factory: Optics, Magnets and their Protection, Detector Backgrounds

A low-energy medium-luminosity Muon Collider (MC) is being studied as a possible Higgs Factory (HF). Electrons from muon decays will deposit more than 300 kW in superconducting magnets of the HF collider ring. This imposes significant challenges to superconducting (SC) magnets used in the MC storage ring (SR) and interaction regions (IR). Magnet designs are proposed which provide high operating gradient and magnetic field in a large aperture to accommodate the large size of muon beams (due to low beta*), as well as a cooling system to intercept the large heat deposition from the showers induced by decay electrons. The distribution of heat deposition in the MC SR lattice elements requires large-aperture magnets in order to accommodate thick high-Z absorbers to protect the SC coils. Based on the developed MARS15 model and intensive simulations, a sophisticated radiation protection system was designed for the collider SR and IR to bring the peak power density in the superconducting coils below the quench limit and reduce the dynamic heat deposition in the cold mass by a factor of 100. The system consists of tight tungsten masks in the magnet interconnect regions and elliptical tungsten liners in the magnet aperture optimized individually for each magnet. These also reduce the background particle fluxes in the collider detector.

43 PARTICLE ACCELERATORS↗