Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON ACTIVATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

AutoSAC-Automated Sample Activation Calculation on VULCAN

AutoSAC is an automated python program to conduct sample activation calculation immediately after neutron scattering experiment on VULCAN. AutoSAC takes account of sample dimensions, compositions, forms, sample environments, neutron beam configurations, neutron scattering history, and proton charged resolved beam power etc., and uses a simplified method to rapidly estimate the radioactivity at end of beam or after. It generates a draft report per sample and repository of radioactivity per measurement and provides feedback of current radioactivity and decay time back to a neutron proposal Slack channel to inform users immediately on sample handling. It also utilizes either the sample note field in EPICS or sample composition or thickness correction and takes slack prompt or command to conduct post-beam SAC by demand. The program can be shared to be used in other beamlines at spallation neutron source with modified instrument configurations including instrument specific characteristic beam fluxes.

An, Ke [Oak Ridge National Laboratory (ORNL), Oak ↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Mutation of active site glutamate in serine hydroxymethyltransferase allows trapping a reactive intermediate: a combined neutron and X-ray crystallography study

Serine hydroxymethyltransferase (SHMT) is a pyridoxal-5′-phosphate (PLP) dependent enzyme that catalyzes a chemical transformation essential for the one-carbon (1C) metabolism. SHMT reversibly converts L-Ser into Gly and transfers a 1C unit to tetrahydrofolate (THF) to give 5,10-methylene-THF (5,10-MTHF). 5,10-MTHF, a 1C-unit donor, plays a crucial role in the downstream biomolecular syntheses required for the cell homeostasis and proliferation. SHMT is a prominent target for the drug discovery to battle bacterial and parasitic infections, and to treat various types of cancer. SHMT-catalyzed chemistry is governed by the general acid-base catalysis. Knowledge of the catalytic mechanism can aid drug design but can only be achieved when the atomic details of each reaction step are mapped, including accurate determination of hydrogen atom positions. Here we utilized the inactive E53Q mutant of Thermus thermophilus ( Tth ) SHMT to directly determine protonation states with room-temperature neutron crystallography and to capture a reactive intermediate containing the PLP-L-Ser external aldimine and THF in the enzyme active site. We observed protonation of the Schiff base nitrogen (N SB ) in the PLP internal aldimine but no change in the protonation states of other ionizable PLP groups and active site residues compared to wild-type Tth SHMT. X-ray structural analysis of the ternary intermediate complex E53Q-Ser-THF that eluded previous structural characterization shows the strategic positioning of the E53Q side chain in close proximity to the external aldimine and THF and reinforces the proposed role for E53 as the driver of proton transfer events along the reaction pathway.

Drago, Victoria N. [Oak Ridge National Laboratory ↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

High repetition-rate 0.5 Hz broadband neutron source driven by the Advanced Laser Light Source

Neutron beams are an essential tool to investigate material structure and perform nondestructive analysis, as they give unique access to element composition, thus ideally complementing density analysis allowed by standard x-rays investigation. Laser-driven neutron sources, though compact and cost-effective, currently have lower average flux than conventional neutron sources, due to the limited repetition rate of the lasers used so far. However, advancements in laser technology allow nowadays to address this challenge. Here, we report results obtained at the Advanced Laser Light Source characterizing stable production of broadband (0.1–2 MeV) neutrons produced at a high repetition rate (0.5 Hz). The interaction of laser pulses of 22 fs duration and 3.2 J on-target energy with 2-μm-thick tantalum targets produced protons in the Target Normal Sheath Acceleration (TNSA) regime up to 7.3 MeV. These protons were subsequently converted into neutrons by (p,n) reactions in lithium fluoride (LiF). Activation measurements and bubble detectors were used to characterize neutron emissions, with a neutron fluence of up to ∼1.4×105 neutrons/shot/sr and energies mainly between a few hundred of kilo-electron volt and 2 MeV. The total neutron yield was ∼5×105 neutrons/shot. This paves the way for numerous applications, e.g., in homeland security, materials science, or cultural heritage.

Physics↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global characterization of a laser-generated neutron source

Laser-driven neutron sources are routinely produced by the interaction of laser-accelerated protons with a converter. They present complementary characteristics to those of conventional accelerator-based neutron sources (e.g. short pulse durations, enabling novel applications like radiography). We present here results from an experiment aimed at performing a global characterization of the neutrons produced using the Titan laser at the Jupiter Laser Facility (Livermore, USA), where protons were accelerated from 23 $\mathrm {\mu }$ m thick plastic targets and directed onto a LiF converter to produce neutrons. For this purpose, several diagnostics were used to measure these neutron emissions, such as CR-39, activation foils, time-of-flight detectors and direct measurement of $^7{\rm Be}$ residual activity in the LiF converters. The use of these different, independently operating diagnostics enables comparison of the various measurements performed to provide a robust characterization. These measurements led to a neutron yield of $2.0\times 10^{9}$ neutrons per shot with a modest angular dependence, close to that simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics↗

Validation and demonstration of the AEFC as a practical safeguards tool for inventory verification

The Advanced Experimental Fuel Counter (AEFC) is a nondestructive assay (NDA) instrument designed to determine the residual fissile mass in irradiated fuel assemblies for safeguards verification purposes. This is done by actively interrogating an assembly with a neutron source and measuring the total (Singles) and correlated (Doubles) neutron count rates resulting from induced fissions in the irradiated nuclear fuel and relating those rates to the residual fissile mass using calibration curves. Comprehensive NDA measurements of the irradiated fuel inventory at Israeli Research Reactor 1 (IRR-1) were taken with the AEFC to validate a set of previously developed calibration curves. During the campaign, measurements were acquired of 32 standard fuel assemblies and three control assemblies in just nine days. This is a significant majority of the research reactor's irradiated fuel inventory and the largest data set gathered by the AEFC to date. Many of the fuel assemblies measured during the campaign had much shorter cooling times than those assemblies previously measured with the instrument. Calibration curves developed from previous AEFC deployments were used to determine the residual 235 U mass in the measured standard fuel assemblies. The results of the campaign demonstrated that the AEFC can be used to estimate the 235 U mass remaining in a large number of irradiated fuel assemblies with 1%–5% uncertainty in a reasonable amount of time despite operating in a high dose environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Testing the Activation Analysis for Fusion in OpenMC

OpenMC is a community-developed Monte Carlo neutron and photon transport simulation code. It can perform fission simulations such as fixed-source, k-eigenvalue, and subcritical multiplication calculations on models built using either a constructive solid geometry or CAD representation. To explore the use of OpenMC for fusion activation analysis, a detailed model of the Fusion Neutronics Science Facility (FNSF) was first developed for comparisons against an existing SERPENT model. A 90-degree model of FNSF in Standard-Triangle-Language (STL) CAD format was converted to Constructive Solid Geometry (CSG) using each code's built-in functions, and the geometries were validated by ensuring no cells overlapped and no particles were lost during simulations. The neutron fluxes were calculated and compared for multiple components close to the plasma. The results show differences mostly below 1% in fluxes and averaged 8% for activity and decay heat. Here, the work described in this study tests the CAD-based geometry using the DagMC toolkit in OpenMC and compares the activation analysis of OpenMC to SERPENT code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Activation of Insulation in Low Power Nuclear Experiments

Nuclear experiments aim to test new designs, procedures, and materials. Similar to conventional power reactors, potential sources of worker exposure to radiation is a primary concern. One such concern is the insulation materials that are used in or near the reactor, which can often create dust when being handled. If this material receives a substantial neutron dose, then it can become activated, which can pose a health risk if inhaled or ingested. This analysis looked at the activation of, and conservative dose estimates from, industrial grade insulations that may be used in a reactor experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Fusion Neutron Generator

The proposed code, named FROG (Fusion neutron Generator) is built upon the open-source particle transport Monte Carlo toolkit Geant4. Geant4 provides C++ classes that can be leveraged to build application-specific codes dealing with the transport of particles through matter. Geant4-based codes are applied in high-energy particle physics experiments, medical applications, shielding, and space applications for example. The FROG code allows the user to define the geometry of a neutron converter device shaped as a hollow cylinder, where a neutron breeding material such as lithium deuteride (LiD) is cladded by two concentric cylinders. Such neutron converter is then placed inside a regular nuclear fission reactor, where thermal neutrons will react with the neutron breeder material (typically, Lithium 6), and through a series of reactions, will generate high-energy neutrons – neutrons whose kinetic energy are around 14 MeV. The hollowed central portion can hold a specimen that will be bombarded by high-energy neutrons created inside the neutron breeding material. Figuratively speaking, this type of device transforms neutrons from thermal (~0.625 eV) to fusion (~14 MeV) energies and is sometimes termed “fusion-to-thermal neutron converters” in the literature. The code consists of C++ source file compiled and linked to generate an executable. The user can select the dimensions of the converter (radius, length, and thickness of the breeder material), the breeder material type, the cladding material, and the specimen material that will be activated or irradiated. As input, the neutron flux for a specific location inside a reactor, for instance, positions in ATR, is required. As output, the code predicts the number of high-energy neutrons produced, the total neutron flux and fluence as well as its detailed spectrum. The physics involved in such device is very complex, as it requires modeling neutron transport, light-ion (tritons) transport, as well as fusion reactions. The Geant4 toolkit provides the required physical models.

Martin, NicholasP. [Idaho National Laboratory (INL↗

An Active Learning-Based Streaming Pipeline for Reduced Data Training of Structure Finding Models in Neutron Diffractometry

Structure determination workloads in neutron diffractometry are computationally expensive and routinely require several hours to many days to determine the structure of a material from its neutron diffraction patterns. The potential for machine learning models trained on simulated neutron scattering patterns to significantly speed up these tasks have been reported recently. However, the amount of simulated data needed to train these models grows exponentially with the number of structural parameters to be predicted and poses a significant computational challenge. To overcome this challenge, we introduce a novel batch-mode active learning (AL) policy that uses uncertainty sampling to simulate training data drawn from a probability distribution that prefers labelled examples about which the model is least certain. We confirm its efficacy in training the same models with ∼ 75% less training data while improving the accuracy. We then discuss the design of an efficient stream-based training workflow that uses this AL policy and present a performance study on two heterogeneous platforms to demonstrate that, compared with a conventional training workflow, the streaming workflow delivers ∼ 20% shorter training time without any loss of accuracy.

Wang, Tianle [Brookhaven National Laboratory (BNL)↗