Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fast-neutron spectrometer developments

Li6 sandwich-type neutron spectrometer is equipped with proportional counter for particle identification. System uses current-sensitive preamplifiers to minimize pile-up of gamma-ray and particle pulses.

Moler, R. B.↗

The spectrum of neutrons at 60 hg m(-2)

The rate of neutron interactions was measured for the energy range 7.5 to 60 MeV, using a 3.85 kg cell of liquid scintillator. The neutrons are selected by pulse shape discrimination, with anticoincidence counters used to reduce interference from muons transversing the scintillator. The observed flux is interpreted in terms of neutrons produced from environmental uranium and thorium, those resulting from the capture of negative muons in nuclei and those from fast muon interactions.

Barton, J. C.↗

Aspects of Neutron Star and Black Hole Transients in RXTE Observations

Scans of the the galactic center with the Proportional Counter Array on the Rossi X-ray Timing Explorer have discovered the outbursts of many neutron star and black hole binary transients early in the outbursts. We have had observations during the rise of the transients which allow us to study the spectral and timing characteristics. Some of the transients are also identified as radio sources, with compact cores and jet ejections. A recent example is H 1743-322, a recurrent black hole candidate, in which the ejection of radio emitting plasma is correlated with changes in the spectral characteristics. I will review the properties of black hole transients compare the characteristics of neutron star transients.

Swank, J.↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector

SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of Apollo 17 Epoch Neutron Spectrum as a Benchmark in Testing LEND Collimated Sensor

The Apollo 17 neutron experiment LPNE provided a unique set of data on production of neutrons in the Lunar soil bombarded by Galactic Cosmic Rays (GCR). It serves as valuable "ground-truth" in the age of orbital remote sensing. We used the neutron data attributed to Apollo 17 epoch as a benchmark for testing the LEND's collimated sensor, as introduced by the geometry of collimator and efficiency of He3 counters. The latter is defined by the size of gas counter and pressure inside it. The intensity and energy spectrum of neutrons escaping the lunar surface are dependent on incident flux of Galactic Cosmic Rays (GCR) whose variability is associated with Solar Cycle and its peculiarities. We obtain first the share of neutrons entering through the field of view of collimator as a fraction of the total neutron flux by using the angular distribution of neutron exiting the Moon described by our Monte Carlo code. We computed next the count rate of the 3He sensor by using the neutron energy spectrum from McKinney et al. [JGR, 2006] and by consider geometry and gas pressure of the LEND sensor. Finally the neutron count rate obtained for the Apollo 17 epoch characterized by intermediate solar activity was adjusted to the LRO epoch characterized by low solar activity. It has been done by taking into account solar modulation potential, which affects the GCR flux, and in turn changes the neutron albedo flux.

Chin, Gordon↗

Large scale solar modulation of 500 MeV/N galactic cosmic rays seen from 1-30 AU

Using measurements of cosmic rays obtained by Cerenkov counters on Pioneer 10 and Pioneer 11 and neutron monitor data from Earth, the spatial and temperal development of cosmic ray modulation during the last solar maximum were observed. The large-scale features of modulation and recovery are similar at these three sites and thus appear rotationally symmetric near the ecliptic plane. Outward propagating features characterize the radial dependence. The decline of the old cosmic ray cycle is marked by steplike decreases that propagate outward at nearly the solar wind velocity. During the start of the new cosmic ray cycle, recovery occurs first in the inner heliosphere and, after a lag comparable with that of the declining phase, appears later farther out. However, the direction of diffusive propagation is still inward, because the gradient remains positive. Forbush decreases are common at all three sites, and are evidently of great importance in understanding modulation. The largest decrease occurred during a short series of events in the summer of 1982 and had half the amplitude of the eleven year cycle.

Fillius, W.↗

Large-scale solar modulation of greater than approximately 500 MeV/nucleon galactic cosmic rays seen from 1 to 30 AU

Using measurements of cosmic rays obtained by Cerenkov counters on Pioneer 10 and Pioneer 11 and neutron monitor data from earth, the spatial and temporal development of cosmic ray modulation during the last solar maximum were observed. The large-scale features of modulation and recovery are similar at these three sites and thus appear rotationally symmetric near the ecliptic plane. Outward propagating features characterize the radial dependence. The decline of the old cosmic ray cycle is marked by steplike decreases that propagate outward at nearly the solar wind velocity. During the start of the new cosmic ray cycle, recovery occurs first in the inner heliosphere and, after a lag comparable with that of the declining phase, appears later farther out. However, the direction of diffusive propagation is still inward, because the gradient remains positive. Forbush decreases are common at all three sites, and are evidently of great importance in understanding modulation. The largest decrease occurred during a short series of events in the summer of 1982 and had half the amplitude of the eleven year cycle.

Fillius, W.↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing 3D asymmetries in laser-direct-drive implosions on OMEGA

Three-dimensional reconstruction algorithms have been developed which determine the hot-spot velocity, hot-spot apparent ion temperature distribution, and fuel areal density distribution present in laser-direct-drive inertial con finement fusion implosions on the OMEGA laser. These reconstructions rely on multiple independent measurements of the neutron energy spectrum emitted from the fusing plasma. Measurements of the neutron energy spectrum on OMEGA are made using a suite of quasi-orthogonal neutron time-of-flight detectors and a magnetic recoil spectrometer. These spectrometers are positioned strategically around the OMEGA target chamber to provide unique 3-D measurements of the conditions of the fusing hot spot and compressed fuel near peak compression. Here, the uncertainties involved in these 3-D reconstructions are discussed and are used to identify a new nTOF diagnostic line of sight which when built will reduce the uncertainty in the hot-spot apparent ion temperature distribution from 0.7 to < 0.4 keV.

47 OTHER INSTRUMENTATION↗

Report to NCSP on 2008 DANCE measurements of 233 U($\eta$,$\gamma$)

Uranium-233 plays an important role in the Th-U fuel cycle, with substantial production in the cycle. This cycle has been proposed as an alternative to the U-Pu fuel cycle due to its reduced production of transuranic elements. An accurate measurement of the 233 U($\eta$,$\gamma$) cross section is required by the National Criticality Safety Program (NCSP) to complete the neutron-induced cross section data, where experimental capture cross section data are scarce and were measured decades ago. The most recent capture cross section data available in the literature were measured in 2007 at the n_TOF facility (CERN); in the 60s measurements were performed at Rensselaer Polytechnic Institute (RPI) and at LANL. Finally, as reported by ORNL, a new evaluation with a revised (renormalized) fission cross section is needed on 233 U. The challenge for this measurement lies in the difficulty of measuring the capture cross section data in the competing fission background, as the fission cross section is around one order of magnitude larger than the capture cross section for 233 U. The accuracy of a capture cross section measurement depends on discrimination between $\gamma$’s produced in capture and fission reactions, for which an experimental setup combining capture and fission detectors is needed. For the ($\eta$,$\gamma$) cross section measurement at LANSCE, this discrimination is achieved by combining the Detector for Advanced Neutron Capture Experiments (DANCE), to measure $\gamma$’s from capture reactions, with a Parallel Plate Avalanche Counter (PPAC) to tag the $\gamma$’s produced by fission. This method was successfully used to measure 235 U and 239 Pu capture cross sections. In these measurements, the neutron capture cross section was determined in a large fission background well above 100 keV. As part of the NCSP nuclear data effort, we have looked at past DANCE measurements on 233 U($\eta$,$\gamma$) and evaluated whether existing data is adequate to apply this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗