At least 91 records · Page 5

Low-dose computed tomography image restoration using previous normal-dose scan

Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use of the previous normal-dose scan via the presented ndiNLM algorithm is noticeable as compared to a similar approach without using the previous normal-dose scan. Conclusions: For low-dose CT image restoration, the presented ndiNLM method is robust in preserving the spatial resolution and identifying the low-contrast structure. The authors can draw the conclusion that the presented ndiNLM algorithm may be useful for some clinical applications such as in perfusion imaging, radiotherapy, tumor surveillance, etc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrodynamic lubrication of rigid nonconformal contacts in combined rolling and normal motion

A numerical solution to the problem of hydrodynamic lubrication of rigid point contacts with an isoviscous, incompressible lubricant was obtained. The hydrodynamic load-carrying capacity under unsteady (or dynamic) conditions arising from the combined effects of squeeze motion superposed upon the entraining motion was determined for both normal approach and separation. Superposed normal motion considerably increases net load-carrying capacity during normal approach and substantially reduces net load-carrying capacity during separation. Geometry was also found to have a significant influence on the dynamic load-carrying capacity. The ratio of dynamic to steady state load-carrying capacity increases with increasing geometry parameter for normal approach and decreases during separation. The cavitation (film rupture) boundary is also influenced significantly by the normal motion, moving downstream during approach and upstream during separation. For sufficiently high normal separation velocity the rupture boundary may even move upstream of the minimum-film-thickness position. Sixty-three cases were used to derive a functional relationship for the ratio of the dynamic to steady state load-carrying capacity in terms of the dimensionless normal velocity parameter (incorporating normal velocity, entraining velocity, and film thickness) and the geometry parameter.

Ghosh, M. K.↗

Hydrodynamic lubrication of rigid nonconformal contacts in combined rolling and normal motion

A numerical solution to the problem of hydrodynamic lubrication of rigid point contacts with an isoviscous, incompressible lubricant was obtained. The hydrodynamic load-carrying capacity under unsteady (or dynamic) conditions arising from the combined effects of squeeze motion superposed upon the entraining motion was determined for both normal approach and separation. Superposed normal motion considerably increases net load-carrying capacity during normal approach and substantially reduces net load-carrying capacity during separation. Geometry was also found to have a significant influence on the dynamic load-carrying capacity. The ratio of dynamic to steady state load-carrying capacity increases with increasing geometry parameter for normal approach and decreases during separation. The cavitation (film rupture) boundary is also influenced significantly by the normal motion, moving downstream during approach and upstream during separation. For sufficiently high normal separation velocity the rupture boundary may even move upstream of the minimum-film-thickness position. Sixty-three cases were used to derive a functional relationship for the ratio of the dynamic to steady state load-carrying capacity in terms of the dimensionless normal velocity parameter (incorporating normal velocity, entraining velocity, and film thickness) and the geometry parameter.

Ghosh, M. K.↗

Chromosome Aberrations in Normal and Ataxia-Telangiectasia Cells Exposed to Heavy Ions

Although cells derived from Ataxia Telangiectasia (AT) patients are known to exhibit abnormal responses to ionizing radiations, its underlying mechanism still remains unclear. Previously, the authors reported that at the same gamma-irradiation dose AT cells show higher frequencies of misrepair and deletions compared to normal human fibroblast cells. In this study, we investigated the effects of heavy ions beams on chromosomal aberrations in normal and AT cells. Normal and AT fibroblast cells arrested at G0/G1 phase were irradiated with 2 Gy of X-rays, 490 MeV/u Silicon (LET 55 keV/m), 500 MeV/u Iron (LET 185 keV/m) and 200 MeV/u Iron (LET 440 keV/m) particles, and then cells were allowed to repair for 24 hours at 37 degrees before subculture. Calyculin-A induced PCC method was employed to collect G2/M chromosomes and whole DNA probes 1 and 3 were used to analyze chromosomal aberrations such as color-junctions, deletions, simple exchanges (incomplete and reciprocal exanges) and complex-type exchanges. The percentages of aberrant cells were higher when normal and AT cells were exposed to heavy ions compared to X-rays, and had a tendency to increase with increasing LET up to 185 keV/m and then decreased at 440 keV/m. When the frequency of color-junctions per cell was compared after X-ray exposure, AT cells had around three times higher frequency of color-junctions (mis-rejoining) than normal cells. However, at 185 keV/m there was no difference in the frequency of color-junctions between two cell lines. It was also found that the frequency of simple exchanges per cell was almost constant in AT cells regardless LET levels, but it was LET dependent for normal cells. Interestingly, the frequency of simple exchanges was higher for AT cells when it was compared at 185 keV/m but AT cells had more complex-type exchanges at the same LET levels. Heavy ions are more efficient in inducing chromosome aberrations in normal and AT cells compared to X-rays, and the aberration types between normal and AT fibroblast appeared different probably due to difference in the ATM gene function.

Kawata, T.↗

Pre-Test Assessment of the Use Envelope of the Normal Force of a Wind Tunnel Strain-Gage Balance

The relationship between the aerodynamic lift force generated by a wind tunnel model, the model weight, and the measured normal force of a strain-gage balance is investigated to better understand the expected use envelope of the normal force during a wind tunnel test. First, the fundamental relationship between normal force, model weight, lift curve slope, model reference area, dynamic pressure, and angle of attack is derived. Then, based on this fundamental relationship, the use envelope of a balance is examined for four typical wind tunnel test cases. The first case looks at the use envelope of the normal force during the test of a light wind tunnel model at high subsonic Mach numbers. The second case examines the use envelope of the normal force during the test of a heavy wind tunnel model in an atmospheric low-speed facility. The third case reviews the use envelope of the normal force during the test of a floor-mounted semi-span model. The fourth case discusses the normal force characteristics during the test of a rotated full-span model. The wind tunnel model's lift-to-weight ratio is introduced as a new parameter that may be used for a quick pre-test assessment of the use envelope of the normal force of a balance. The parameter is derived as a function of the lift coefficient, the dimensionless dynamic pressure, and the dimensionless model weight. Lower and upper bounds of the use envelope of a balance are defined using the model's lift-to-weight ratio. Finally, data from a pressurized wind tunnel is used to illustrate both application and interpretation of the model's lift-to-weight ratio.

strain-gage balance↗

Genomic aberrations in normal tissue adjacent to HER2-amplified breast cancers: field cancerization or contaminating tumor cells?

Field cancerization effects as well as isolated tumor cell foci extending well beyond the invasive tumor margin have been described previously to account for local recurrence rates following breast conserving surgery despite adequate surgical margins and breast radiotherapy. To look for evidence of possible tumor cell contamination or field cancerization by genetic effects, a pilot study (Study 1: 12 sample pairs) followed by a verification study (Study 2: 20 sample pairs) were performed on DNA extracted from HER2-positive breast tumors and matching normal adjacent mammary tissue samples excised 1–3 cm beyond the invasive tumor margin. High-resolution molecular inversion probe (MIP) arrays were used to compare genomic copy number variations, including increased HER2 gene copies, between the paired samples; as well, a detailed histologic and immunohistochemical (IHC) re-evaluation of all Study 2 samples was performed blinded to the genomic results to characterize the adjacent normal tissue composition bracketing the DNA-extracted samples. Overall, 14/32 (44 %) sample pairs from both studies produced genome-wide evidence of genetic aberrations including HER2 copy number gains within the adjacent normal tissue samples. The observed singleparental origin of monoallelic HER2 amplicon haplotypes shared by informative tumor–normal pairs, as well as commonly gained loci elsewhere on 17q, suggested the presence of contaminating tumor cells in the genomically aberrant normal samples. Histologic and IHC analyses identified occult 25–200 lm tumor cell clusters overexpressing HER2 scattered in more than half, but not all, of the genomically aberrant normal samples re-evaluated, but in none of the genomically normal samples. These genomic and microscopic findings support the conclusion that tumor cell contamination rather than genetic field cancerization represents the likeliest cause of local clinical recurrence rates following breast conserving surgery, and mandate caution in assuming the genomic normalcy of histologically benign appearing peritumor breast tissue.

59 BASIC BIOLOGICAL SCIENCES↗

A method for estimating direct normal solar irradiation from satellite data for a tropical environment

In order to investigate a potential use of concentrating solar power technologies and select an optimum site for these technologies, it is necessary to obtain information on the geographical distribution of direct normal solar irradiation over an area of interest. In this work, we have developed a method for estimating direct normal irradiation from satellite data for a tropical environment. The method starts with the estimation of global irradiation on a horizontal surface from MTSAT-1R satellite data and other ground-based ancillary data. Then a satellite-based diffuse fraction model was developed and used to estimate the diffuse component of the satellite-derived global irradiation. Based on this estimated global and diffuse irradiation and the solar radiation incident angle, the direct normal irradiation was finally calculated. To evaluate its performance, the method was used to estimate the monthly average hourly direct normal irradiation at seven pyrheliometer stations in Thailand. It was found that values of monthly average hourly direct normal irradiation from the measurements and those estimated from the proposed method are in reasonable agreement, with a root mean square difference of 16% and a mean bias of -1.6%, with respect to mean measured values. After the validation, this method was used to estimate the monthly average hourly direct normal irradiation over Thailand by using MTSAT-1R satellite data for the period from June 2005 to December 2008. Results from the calculation were displayed as hourly and yearly irradiation maps. These maps reveal that the direct normal irradiation in Thailand was strongly affected by the tropical monsoons and local topography of the country. (author)

14 SOLAR ENERGY↗

A Pseudoreversible Normalizing Flow for Stochastic Dynamical Systems with Various Initial Distributions

Here, we present a pseudoreversible normalizing flow method for efficiently generating samples of the state of a stochastic differential equation (SDE) with various initial distributions. The primary objective is to construct an accurate and efficient sampler that can be used as a surrogate model for computationally expensive numerical integration of SDEs, such as those employed in particle simulation. After training, the normalizing flow model can directly generate samples of the SDE’s final state without simulating trajectories. The existing normalizing flow model for SDEs depends on the initial distribution, meaning the model needs to be retrained when the initial distribution changes. The main novelty of our normalizing flow model is that it can learn the conditional distribution of the state, i.e., the distribution of the final state conditional on any initial state, such that the model only needs to be trained once and the trained model can be used to handle various initial distributions. This feature can provide a significant computational saving in studies of how the final state varies with the initial distribution. Additionally, we propose to use a pseudoreversible network architecture to define the normalizing flow model, which has sufficient expressive power and training efficiency for a variety of SDEs in science and engineering, e.g., in particle physics. We provide a rigorous convergence analysis of the pseudoreversible normalizing flow model to the target probability density function in the Kullback–Leibler divergence metric. Numerical experiments are provided to demonstrate the effectiveness of the proposed normalizing flow model.

97 MATHEMATICS AND COMPUTING↗

A Convex Optimization Approach to Improving Suboptimal Hyperparameters of Sliced Normal Distributions

Sliced Normal (SN) distributions are a generalization of Gaussian distributions where the quadratic argument of the exponential is replaced with a sum of squares polynomial. SNs may be used to represent the distribution of a diverse set of random variables including multi-modal, non-symmetric, and skewed distributions. Unfortunately, the likelihood function of a SN includes a normalization constant and the inclusion of this normalization constant makes the likelihood a non-convex function of the hyperparameters which define the SN. In previous work, suboptimal fitting of the hyperparameters was performed by transforming the given data into a higher dimensional monomial basis and selecting the optimal hyperparameters of a Gaussian fit in this space. However, this approach did not account for the effect of lifting on the normalization constant. Indeed, it was observed that as the number of monomials is increased the likelihood of the Sliced Normal can decrease. In this paper, we increase the likelihood of Sliced Normals found using the previous method by developing a convex formulation which scales the covariance matrix of the Gaussian fit such that the likelihood of the Sliced Normal is maximized. The result is significant improvements of the log likelihood of fitted SN distributions, including a significant increase, especially for problems with 500+ monomials.

Convex optimization approach to improving suboptim↗

Early Radiosurgery Improves Hearing Preservation in Vestibular Schwannoma Patients With Normal Hearing at the Time of Diagnosis

Purpose: Vestibular schwannomas (VS) are increasingly diagnosed in patients with normal hearing because of advances in magnetic resonance imaging. We sought to evaluate whether stereotactic radiosurgery (SRS) performed earlier after diagnosis improved long-term hearing preservation in this population. Methods and Materials: We queried our quality assessment registry and found the records of 1134 acoustic neuroma patients who underwent SRS during a 15-year period (1997-2011). We identified 88 patients who had VS but normal hearing with no subjective hearing loss at the time of diagnosis. All patients were Gardner-Robertson (GR) class I at the time of SRS. Fifty-seven patients underwent early (≤2 years from diagnosis) SRS and 31 patients underwent late (>2 years after diagnosis) SRS. At a median follow-up time of 75 months, we evaluated patient outcomes. Results: Tumor control rates (decreased or stable in size) were similar in the early (95%) and late (90%) treatment groups (P=.73). Patients in the early treatment group retained serviceable (GR class I/II) hearing and normal (GR class I) hearing longer than did patients in the late treatment group (serviceable hearing, P=.006; normal hearing, P<.0001, respectively). At 5 years after SRS, an estimated 88% of the early treatment group retained serviceable hearing and 77% retained normal hearing, compared with 55% with serviceable hearing and 33% with normal hearing in the late treatment group. Conclusions: SRS within 2 years after diagnosis of VS in normal hearing patients resulted in improved retention of all hearing measures compared with later SRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anomalous normal fluid response in a chiral superconductor UTe2

Abstract Chiral superconductors have been proposed as one pathway to realize Majorana normal fluid at its boundary. However, the long-sought 2D and 3D chiral superconductors with edge and surface Majorana normal fluid are yet to be conclusively found. Here, we report evidence for a chiral spin-triplet pairing state of UTe 2 with surface normal fluid response. The microwave surface impedance of the UTe 2 crystal was measured and converted to complex conductivity, which is sensitive to both normal and superfluid responses. The anomalous residual normal fluid conductivity supports the presence of a significant normal fluid response. The superfluid conductivity follows the temperature behavior predicted for an axial spin-triplet state, which is further narrowed down to a chiral spin-triplet state with evidence of broken time-reversal symmetry. Further analysis excludes trivial origins for the observed normal fluid response. Our findings suggest that UTe 2 can be a new platform to study exotic topological excitations in higher dimension.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Normal and abnormal grain growth in nanostructured gold film

Thin nanostructured gold films were deposited on SiO{sub 2} by the sputtering technique at room temperature. Films of different thicknesses were deposited ranging from 2 to 16 nm. The film morphology as a function of the thickness was analyzed by microscopic techniques such as atomic force microscopy and transmission electron microscopy. These analyses allowed us to clarify the growth mechanism of the gold nanograins forming the film: in a first stage of growth (2-6 nm) normal grain growth proceeds; then (8-16 nm) the grain surface energy anisotropy drives the growth of abnormal large gold grains by annihilation of the normal ones. During the abnormal growth other normal grain continue to growth. The normal grain size distribution is showed to be a monomodal log-normal distribution that evolves toward larger mean grain radius continuously following a scaling law. By determination of the grain growth exponent, the kinetic mechanism responsible of the grain growth is demonstrated to be the gold atomic diffusion on grain boundaries. By fitting the experimental data using established theoretical models, the room-temperature gold grain boundary coefficient diffusion and mobility were derived. The abnormal grain grows, manifest itself as a bimodal grain size distribution: with the log-normal distribution of the normal grain size, a second Gaussian grain size distribution rises, shifting toward lower size increasing the film thickness. The abnormal grain growth continues until all the abnormal grain boundaries meet each other.

36 MATERIALS SCIENCE↗

The spectral theorem for quaternionic unbounded normal operators based on the S-spectrum

In this paper we prove the spectral theorem for quaternionic unbounded normal operators using the notion of S-spectrum. The proof technique consists of first establishing a spectral theorem for quaternionic bounded normal operators and then using a transformation which maps a quaternionic unbounded normal operator to a quaternionic bounded normal operator. With this paper we complete the foundation of spectral analysis of quaternionic operators. The S-spectrum has been introduced to define the quaternionic functional calculus but it turns out to be the correct object also for the spectral theorem for quaternionic normal operators. The lack of a suitable notion of spectrum was a major obstruction to fully understand the spectral theorem for quaternionic normal operators. A prime motivation for studying the spectral theorem for quaternionic unbounded normal operators is given by the subclass of unbounded anti-self adjoint quaternionic operators which play a crucial role in the quaternionic quantum mechanics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Normal modes for electromagnetically induced transparency in a lambda system of degenerate energy levels

This paper presents an analytical study of the formation of normal modes of probe light for electromagnetically induced transparency in a lambda system of quantum transitions between {sup 3}P{sub 0}, and {sup 3}P{sub 2} levels in the case of an elliptically polarised control field and inhomogeneous broadening. The normal modes are elliptically polarised waves with identical polarisation ellipse eccentricities but different electric vector rotation directions. The mode eccentricities are only determined by the control field polarisation ellipse eccentricity. The major axis of the polarisation ellipse of one of the normal modes is parallel to the major axis of the control light polarisation ellipse, whereas the major axis of the polarisation ellipse of the other normal mode is perpendicular to it. The former type of mode has a higher group velocity than does the latter type of mode, and both velocities depend on control light polarisation ellipse eccentricity and intensity. Probe light with an arbitrary elliptical polarisation is the sum of normal modes which propagate independently of each other. Since the modes differ in group velocity, a probe pulse entering the medium splits into two components, each of which is a normal mode. The fraction of energy in each normal mode depends only on polarisation characteristics of coupled fields and is independent of their intensity. The bibliography includes 27 references. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Normal modes of strictly resonant and quasi-resonant regimes of electromagnetically induced transparency

We report the results of a theoretical study of the evolution of a probe pulse under electromagnetically induced transparency conditions in the lambda scheme of degenerate inhomogeneously broadened quantum transitions. It is assumed that the interacting fields are elliptically polarised, and their effect on the medium can be either strictly resonant or quasi-resonant. It is shown that probe light in a medium can be represented as the sum of two normal modes, i.e. quasi-monochromatic elliptically polarised fields propagating independently of each other. The major axis of the polarisation ellipse of the normal mode of the first type is parallel, and that of the second type is perpendicular to the major axis of the polarisation ellipse of the control light. Due to the fact that velocities of normal-mode pulses are different, a single probe pulse entering a medium splits into individual pulses inside the medium, each of which transfers the energy of one of the normal modes. In the case of quasi-resonance, the splitting occurs at a shorter distance than in the case of strict resonance. If normal modes are not phase modulated at the input surface of the medium, then in the case of quasi-resonance they become phase modulated during their propagation inside the medium, whereas this does not occur in the case of strict resonance. It is shown that in the case of quasi-resonance, the phase modulation value of the mode of the second of the above types significantly exceeds that of the first type. The medium transparency for the normal mode of the first type slightly decreases with the transition from the case of strict resonance to the case of quasi-resonance, while the medium transparency for the mode of the second type decreases significantly. The total probe field, which is the sum of the normal modes, has phase modulation before it splits into mode pulses in cases of both strict resonance and quasi-resonance, even if it does not have it on the input surface. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density- and wavefunction-normalized Cartesian spherical harmonics for l ≤ 20

The widely used pseudoatom formalism in experimental X-ray charge-density studies makes use of real spherical harmonics when describing the angular component of aspherical deformations of the atomic electron density in molecules and crystals. The analytical form of the density-normalized Cartesian spherical harmonic functions for up to l ≤ 7 and the corresponding normalization coefficients were reported previously by Paturle & Coppens. It was shown that the analytical form for normalization coefficients is available primarily for l ≤ 4. Only in very special cases it is possible to derive an analytical representation of the normalization coefficients for 4 < l ≤ 7. In most cases for l > 4 the density normalization coefficients were calculated numerically to within seven significant figures. In this study we review the literature on the density-normalized spherical harmonics, clarify the existing notations, use the Paturle–Coppens method in the Wolfram Mathematica software to derive the Cartesian spherical harmonics for l ≤ 20 and determine the density normalization coefficients to 35 significant figures, and computer-generate a Fortran90 code. The article primarily targets researchers who work in the field of experimental X-ray electron density, but may be of some use to all who are interested in Cartesian spherical harmonics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Normalization of the modulation transfer function: The open-field approach

The modulation transfer function (MTF) is widely used to describe the spatial resolution of x-ray imaging systems. The MTF is defined to have a zero-frequency value of unity, and it is common practice to ensure this by normalizing a measured MTF curve by the zero-frequency value. However, truncation of the line spread function (LSF) within a finite region of interest (ROI) results in spectral leakage and causes a reduction in the measured MTF zero-frequency value equal to the area of truncated LSF tails. Subsequent normalization by this value may result in inflated MTF values. We show that open-field normalization with the edge method produces accurate MTF values at all nonzero frequencies without need for further normalization by the zero-frequency value, regardless of ROI size. While both normalization techniques are equivalent for a sufficiently large ROI, a 5% inflation in MTF values was observed for a CsI-based flat-panel system when using a 10 cm ROI. Use of open-field normalization avoids potential inflation caused by zero-frequency normalization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Normal tissue dose conformality measures to guide radiotherapy fractionation decisions

Purpose: To determine conditions under which hypofractionation could be favorable for a normal tissue--even if tumor [{alpha}/{beta}] exceeds the normal tissue's [{alpha}/{beta}]. Methods: The hypofractionation sufficiency condition (HSC) for an organ is defined as a dose conformality constraint such that, if satisfied, a family of tumor control probability isoeffective fractionation schemes will show decreasing normal tissue complication probability with decreasing number of fractions. Results: In the extended equivalent uniform dose (EUD) model [obtained by replacing dose with linear quadratic (LQ) 2 Gy equivalent dose], the HSC for a normal organ is proven to be satisfied if a suitably weighted average of the relative dose [hypofractionation sufficiency index (HSI)] is less than the ratio of normal tissue to tumor [{alpha}/{beta}]. The HSI is determined solely by dose distribution and the normal tissue volume factor, ''a.'' If the HSC is satisfied for every normal tissue of concern, then there is a therapeutic gain with hypofractionation. The corresponding multifractionation sufficiency condition (therapeutic gain with increasing number of fractions) and multifractionation sufficiency index (MSI) are also derived. A sample clinical case is presented. Conclusions: Within the context of the LQ/EUD models, conformality measures (HSI and MSI) can be used to inform fractionation decisions.

60 APPLIED LIFE SCIENCES↗