Development of a Telescoping Vaned Exhaust Nozzle for the ASTOVL LiftFan(Trademark) Application

A discussion on the development of a Telescoping, Vaned, Exhaust Nozzle (TEVEN) is presented. This nozzle was challenged to meet the thrust vectoring requirements of an Advanced Short Takeoff and Vertical Landing (ASTOVL) aircraft. The nozzle underwent a development process from concepts to detail design using computational flow analyses and from subscale performance verification tests to full-scale hardware design. The LiftFan(Trademark) nozzle is capable of providing a pitch vector range of about 80 degrees from up to 20 degrees forward to 60 degrees aft. In addition, a set of post exit yaw doors provide +/- 10 degrees yaw while maintaining a relatively high performance at all operating conditions. Further, the nozzle is axially compact, to be stowable in very short length (LJD less than 0.3), while efficiently converging the upstream nozzle flow from an annular cross section to a "D" shape at the nozzle exit. The discussion includes a review of various nozzle concepts, viscous flow analyses, and results from 1/3 scale nozzle model tests conducted at NASA LeRC Powered Lift Facility (PLF) in 1994.

Sokhey, Jack S.↗

Selected Performance Measurements of the F-15 ACTIVE Axisymmetric Thrust-Vectoring Nozzle

Flight tests recently completed at the NASA Dryden Flight Research Center evaluated performance of a hydromechanically vectored axisymmetric nozzle onboard the F-15 ACTIVE. A flight-test technique whereby strain gages installed onto engine mounts provided for the direct measurement of thrust and vector forces has proven to be extremely valuable. Flow turning and thrust efficiency, as well as nozzle static pressure distributions were measured and analyzed. This report presents results from testing at an altitude of 30,000 ft and a speed of Mach 0.9. Flow turning and thrust efficiency were found to be significantly different than predicted, and moreover, varied substantially with power setting and pitch vector angle. Results of an in-flight comparison of the direct thrust measurement technique and an engine simulation fell within the expected uncertainty bands. Overall nozzle performance at this flight condition demonstrated the F100-PW-229 thrust-vectoring nozzles to be highly capable and efficient.

Orme, John S.↗

Selected Performance Measurements of the F-15 Active Axisymmetric Thrust-vectoring Nozzle

Flight tests recently completed at the NASA Dryden Flight Research Center evaluated performance of a hydromechanically vectored axisymmetric nozzle onboard the F-15 ACTIVE. A flight-test technique whereby strain gages installed onto engine mounts provided for the direct measurement of thrust and vector forces has proven to be extremely valuable. Flow turning and thrust efficiency, as well as nozzle static pressure distributions were measured and analyzed. This report presents results from testing at an altitude of 30,000 ft and a speed of Mach 0.9. Flow turning and thrust efficiency were found to be significantly different than predicted, and moreover, varied substantially with power setting and pitch vector angle. Results of an in-flight comparison of the direct thrust measurement technique and an engine simulation fell within the expected uncertainty bands. Overall nozzle performance at this flight condition demonstrated the F100-PW-229 thrust-vectoring nozzles to be highly capable and efficient.

Orme, John S.↗

Studies of the acoustic transmission characteristics of coaxial nozzles with inverted velocity profiles, volume 1

The efficiency of internal noise radiation through coannular exhaust nozzle with an inverted velocity profile was studied. A preliminary investigation was first undertaken to: (1) define the test parameters which influence the internal noise radiation; (2) develop a test methodology which could realistically be used to examine the effects of the test parameters; (3) and to validate this methodology. The result was the choice of an acoustic impulse as the internal noise source in the in the jet nozzles. Noise transmission characteristics of a nozzle system were then investigated. In particular, the effects of fan nozzle convergence angle, core extention length to annulus height ratio, and flow Mach number and temperatures were studied. The results are presented as normalized directivity plots.

Dean, P. D.↗

Experimental evaluation of a translating nozzle sidewall radial turbine

An experimental performance evaluation was made of two movable sidewall variable area radial turbines. The turbine designs were representative of the gas generator turbine of a variable flow capacity rotorcraft engine. The first turbine was an uncooled design while the second turbine had a cooled nozzle but an uncooled rotor. The cooled nozzle turbine was evaluated both with and without coolant flow. The test results showed that the movable nozzle wall is a viable and efficient means to effectively control the flow capacity of a radial turbine. Peak efficiencies of the second turbine with and without nozzle coolant were 86.5 and 88 percent respectively. These values are comparable to pivoting vane variable geometry turbines; however, the decrease in efficiency as the flow was varied from the design value was much less for the movable wall turbine. Several design improvements which should increase the turbine efficiency one or two more points are identified. These design improvements include reduced leakage losses and relocation of the vane coolant ejection holes to reduce mainstream disturbance.

Roelke, Richard J.↗

Microwave electrothermal thruster performance in helium gas

The microwave electrothermal thruster presented uses an internally tuned, single-mode cylindrical cavity applicator to focus and match microwave energy into an electrodeless, high pressure flowing gas discharge that is located within a quartz discharge chamber. Experimental measurements of microwave coupling efficiency, thruster energy efficiency, and specific impulse, are obtained for N and He discharges; the efficiency of microwave energy transfer to the discharge is found to be of the order of 95 percent. Higher temperature nozzle materials and more efficient discharge chambers will further enhance performance.

Whitehair, S.↗

Start Up Research Effort in Fluid Mechanics. Advanced Methods for Acoustic and Thrust Benefits for Aircraft Engine Nozzle

In accordance with the project plan for the report period in the proposal titled above, HU and FML teams investigated two sets of concepts for reduction of noise and improvement in efficiency for jet exhaust nozzles of aircraft engines and screws for mixers, fans, propellers and boats. The main achievements in the report period are: (a) Publication of the paper in the AIAA Journal, which described our concepts and some results. (b) The Award in the Civil Research and Development Foundation (CRDF) competition. This 2 year grant for Hampton University (HU) and Central AeroHydrodynamic Institute (TSAGI, Moscow, Russia) supports the research implementation under the current NASA FAR grant. (c) Selection for funding by NASA HQ review panel of the Partnership Awards Concept Paper. This two year grant also will support our current FAR grant. (d) Publication of a Mobius Strip concept in NASA Technical Briefs, June, 1996, and a great interest of many industrial companies in this invention. Successful experimental results with the Mobius shaped screw for mixers, which save more than 30% of the electric power by comparison with the standard screws. Creation of the scientific-popular video-film which can be used for commercial and educational purposes. (e) Organization work, joint meetings and discussions of the NASA LARC JNL Team and HU professors and administration for the solution of actual problems and effective work of the Fluid Mechanics Laboratory at Hampton University. In this report the main designs are enumerated. It also contains for both concept sets: (1) the statement of the problem for each design, some results, publications, inventions, patents, our vision for continuation of this research, and (2) present and expected problems in the future.

White, Samuel G.↗

Thrust performance of isolated 36-chute suppressor plug nozzles with and without ejectors at Mach numbers from 0 to 0.45

Plug nozzles with chute-type noise suppressors were tested with and without ejector shrouds at free-stream Mach numbers from 0 to 0.45 and over a range of nozzle pressure ratios from 2 to 4. A 36-chute suppressor nozzle with an ejector had an efficiency of 94.6 percent at an assumed takeoff pressure ratio of 3.0 and a Mach number of 0.36. This represents only a 3.4 percent performance penalty when compared with the 98 percent efficiency obtained with a previously tested unsuppressed plug nozzle.

Harrington, D. E.↗

Static Investigation of a Multiaxis Thrust-Vectoring Nozzle With Variable Internal Contouring Ability

The thrust efficiency and vectoring performance of a convergent-divergent nozzle were investigated at static conditions in the model preparation area of the Langley 16-Foot Transonic Tunnel. The diamond-shaped nozzle was capable of varying the internal contour of each quadrant individually by using cam mechanisms and retractable drawers to produce pitch and yaw thrust vectoring. Pitch thrust vectoring was achieved by either retracting the lower drawers to incline the throat or varying the internal flow-path contours to incline the throat. Yaw thrust vectoring was achieved by reducing flow area left of the nozzle centerline and increasing flow area right of the nozzle centerline; a skewed throat deflected the flow in the lateral direction.

Wing, David J.↗

Acoustic Efficiency of Azimuthal Modes in Jet Noise Using Chevron Nozzles

The link between azimuthal modes in jet turbulence and in the acoustic sound field has been examined in cold, round jets. Chevron nozzles, however, impart an azimuthal structure on the jet with a shape dependent on the number, length and penetration angle of the chevrons. Two particular chevron nozzles, with 3 and 4 primary chevrons respectively, and a round baseline nozzle are compared at both cold and hot jet conditions to determine how chevrons impact the modal structure of the flow and how that change relates to the sound field. The results show that, although the chevrons have a large impact on the azimuthal shape of the mean axial velocity, the impact of chevrons on the azimuthal structure of the fluctuating axial velocity is small at the cold jet condition and smaller still at the hot jet condition. This is supported by results in the azimuthal structure of the sound field, which also shows little difference in between the two chevron nozzles and the baseline nozzle in the distribution of energy across the azimuthal modes measured.

Brown, Clifford A.↗

Ground test of a large scale 'D' vented thrust deflecting nozzle

Future V/STOL aircraft will require efficient techniques for changing the thrust vector from the vertical direction for VTOL operation to the horizontal direction for conventional flight. Most V/STOL concepts utilize thrust vectoring nozzles to provide this variation in the thrust vector direction. An experimental test program was initiated to demonstrate the capabilities of a large scale 'D' vented thrust deflecting system coupled with a high bypass ratio turbofan engine. Data were obtained for a 'D' vented nozzle mounted behind a YTF-34-F5 turbofan engine. Preliminary data are presented for a variety of test conditions. Attention is given to aspects of 'D' vented nozzle design, the test apparatus, engine-nozzle compatibility, exit area variation, longitudinal vectoring performance, nozzle temperature distribution, and large scale - small scale comparisons.

Rosenberg, E. W.↗

High-power hydrogen arcjet performance

A hydrogen arcjet was operated at power levels ranging from 5 to 30 kW with three different nozzle geometries. Test results using all three nozzle geometries are reported and include variations of specific impulse with flow rate, and thrust with power. Geometric variables investigated included constrictor diameter, length, and diverging exit angle. The nozzle with a constrictor diameter of 1.78 mm and divergence angle of 20 deg was found to give the highest performance. A specific impulse of 1460 s was attained with this nozzle at a thrust efficiency of 29.8 percent. The best efficiency measured was 34.4 percent at a specific impulse of 1045 s. Post test examination of the cathode showed erosion after 28 hours of operation to be small, and limited to the conical tip where steady state arc attachment occurred. Each nozzle was tested to destruction.

Haag, Thomas W.↗

High-power hydrogen arcjet performance

A hydrogen arcjet was operated at power levels ranging from 5 to 30 kW with three different nozzle geometries. Test results using all three nozzle geometries are reported and include variations of specific impulse with flow rate, and thrust with power. Geometric variables investigated included constrictor diameter, length, and diverging exit angle. The nozzle with a constrictor diameter of 1.78 mm and divergence angle of 20 degrees was found to give the highest performance. A specific impulse of 1460 s was attained with this nozzle at a thrust efficiency of 29.8 percent. The best efficiency measured was 34.4 percent at a specific impulse of 1045 s. Post test examination of the cathode showed erosion after 28 hours of operation to be small, and limited to the conical tip where steady state arc attachment occurred. Each nozzle was tested to destruction.

Haag, Thomas W.↗

Experimental study of low Reynolds number nozzles

High-performance electrothermal thrusters operate in a low nozzle-throat Reynolds number regime. Under these conditions, the flow boundary layer occupies a large volume inside the nozzle, contributing to large viscous losses. Four nozzles (conical, bell, trumpet, and modified trumpet) and a sharp-edged orifice were evaluated over a Reynolds number range of 500 to 9000 with unheated nitrogen and hydrogen. The nozzles showed significant decreases in specific impulse efficiency with decreasing Reynolds number. At Reynolds numbers less than 1000, all four nozzles were probably filled with a large boundary layer. The discharge coefficient decreased with Reynolds number in the same manner as the specific impulse efficiency. The bell and modified trumpet nozzles had discharge coefficients 4 to 8 percent higher than those of the cone or trumpet nozzles. The Two-Dimensional Kinetics (TDK) nozzle analysis computer program was used to predict nozzle performance. The results were then compared to the experimental results in order to determine the accuracy of the program within this flow regime.

Grisnik, Stanley P.↗

Experimental study of low Reynolds number nozzles

High-performance electrothermal thrusters operate in a low nozzle-throat Reynolds number regime. Under these conditions, the flow boundary layer occupies a large volume inside the nozzle, contributing to large viscous losses. Four nozzles (conical, bell, trumpet, and modified trumpet) and a sharp-edged orifice were evaluated over a Reynolds number range of 500 to 9000 with unheated nitrogen and hydrogen. The nozzles showed significant decreases in specific impulse efficiency with decreasing Reynolds number. At Reynolds numbers less than 1000, all four nozzles were probably filled with a large boundary layer. The discharge coefficient decreased with Reynolds number in the same manner as the specific impulse efficiency. The bell and modified trumpet nozzles had discharge coefficients 4 to 8 percent higher than those of the cone or trumpet nozzles. The Two-Dimensional Kinetics (TDK) nozzle analysis computer program was used to predict nozzle performance. The results were then compared to the experimental results in order to determine the accuracy of the program within this flow regime.

Grisnik, Stanley P.↗

Model Preparation Areas for Propulsion Airframe Integration Testing at NASA Langley Research Center

Currently there are three major NASA Langley facilities that perform PAI testing. These include the National Transonic Facility, the 14’x22’ Low Speed Wind tunnel, and the Unitary Plan Wind Tunnel. While each of these facilities have their own model preparation areas, the model preparation area located at the NTF complex that focuses on blowing systems with high mass flow requirements support all of the LaRC facilities. The application of a Propulsion Airframe Integration requires special attention to the air delivery system interaction with the model. These interactions typically focus on the tares across the balance associated with inlet and nozzle performance which are related to the mass flow through the system and the efficiency of the inlet and nozzle geometries. While this paper does not characterize any specific propulsion system, it does focus on the mass flow and pressures requirement needed for pretesting such systems prior to wind tunnel installation. Weight flow boundaries for the air delivery system were identified to range from 0.1 to 20 lbm/sec.

Model Preparation Area↗