Search NASA⌕ Search

SEARCH · Search NASA

Results for “NTF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Synthetically Reversible, Proton-Mediated Nitrite N–O Bond Cleavage at a Dicopper Site

A monocationic dicopper(I,I) nitrite complex [Cu 2 (μ-κ 1 :κ 1 -O 2 N)DPFN][NTf 2 ] (2) (DPFN = 2,7-bis(fluoro-di(2-pyridyl)methyl)-1,8-naphthyridine, NTf 2 – = N(SO 2 CF 3 ) 2 – ), was synthesized by treatment of a dicopper acetonitrile complex, [Cu 2 (μ-MeCN)DPFN][NTf 2 ] 2 (1), with tetrabutylammonium nitrite ([nBu 4 N][NO 2 ]). DFT calculations indicate that 2 is one of three linkage isomers that are close in energy and presumably accessible in solution. Reaction of the μ-κ 1 :κ 1 -O 2 N complex with p-TolSH produces nitrous acid (HONO) and the corresponding dicopper thiolate species via an acid–base exchange reaction. Notably, treatment of 2 with HNTf 2 results in N–O bond cleavage in the putative, HONO-ligated complex to form the more thermodynamically favorable nitrosyl-bridged dicopper complex [Cu 2 (μ-NO)(μ-OH)DPFN][NTf 2 ] 2 (4). This scission can be reversed via deprotonation of the hydroxy ligand with KO t Bu. X-ray diffraction studies confirmed the solid-state molecular structures of 2 and 4. DFT calculations were used to construct a reaction coordinate diagram detailing formation of the μ-NO complex and to describe its electronic structure. The nitrosyl ligand in 4 is chemically labile, as demonstrated by its ready displacement in reactions with CO or NO 2 – .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimation of fan pressure ratio requirements and operating performance for the National Transonic Facility

The National Transonic Facility (NTF), a fan-driven, transonic, pressurized, cryogenic wind tunnel, will operate over the Mach number range of 0.10 to 1.20 with stagnation pressures varying from 1.00 to about 8.8 atm and stagnation temperatures varying from 77 to 340 K. The NTF is cooled to cryogenic temperatures by the injection of liquid nitrogen into the tunnel stream with gaseous nitrogen as the test gas. The NTF can also operate at ambient temperatures using a conventional chilled water heat exchanger with air on nitrogen as the test gas. The methods used in estimating the fan pressure ratio requirements are described. The estimated NTF operating envelopes at Mach numbers from 0.10 to 1.20 are presented.

Gloss, B. B.↗

Evaluation of high-contact-ratio spur gears with profile modification

Scoring tests, surface fatigue tests, and single-tooth bending fatigue tests were conducted with four sets of spur gears of standard design and three sets of spur gears of the new tooth form (NTF) design. Scoring tests were conducted in a gear test rig at a speed of 10,000 rpm using a synthetic polyester C5, C6, C7 substituted pentaerythritol oil. Surface fatigue tests were conducted in the same rig at a speed of 10,000 rpm and Hertz stresses of 173 x 10 to the 7th power and 143 x 10 to the 7th power Pa (250,000 and 214,000 psi). Single tooth bending fatigue tests were conducted on both the standard and NTF gears at an initial load that produced a 10.35 x 10 to the eight power Pa (150,000-psi) bending stress. The gears were load cycled to failure or for 3 x 10 to the 6th power cycles, whichever occurred first. The load was increased after test until failure occurred at 3 x 10 to the 6th power cycles or less. Both the standard and NTF gears scored at a gear bulk temperature of approximately 409 K (277 F). At this temperature the load on the NTF gears was 22 percent less than the load on the standard gears. The scoring failure was a function of gear bulk temperature, where for a given lubricant the temperature is a function of gear design, operating load, and speed.

Townsend, D. P.↗

Initial research program for the National Transonic Facility

The construction and checkout of the National Transonic Facility (NTF) have been completed, and detailed calibration is now in progress. The initial NTF research program covers a wide range of study areas falling into three major elements: (1) the assessment of Reynolds number sensitivities for a broad range of configurations and flow phenomena; (2) validation of the ability of NTF to simulate full-scale aerodynamics; and (3) the development of test techniques for improved test simulations in existing wind tunnels. This paper, therefore, is a status report on these various elements of the initial NTF research program.

Gloss, B. B.↗

Analysis of Fluctuating Static Pressure Measurements in a Large High Reynolds Number Transonic Cryogenic Wind Tunnel

Dynamic measurements of fluctuating static pressure levels were made using flush mounted high frequency response pressure transducers at eleven locations in the circuit of the National Transonic Facility (NTF) over the complete operating range of this wind tunnel. Measurements were made at test section Mach numbers from 0.2 to 1.2, at pressure from 1 to 8.6 atmospheres and at temperatures from ambient to -250 F, resulting in dynamic flow disturbance measurements at the highest Reynolds numbers available in a transonic ground test facility. Tests were also made independently at variable Mach number, variable Reynolds number, and variable drivepower, each time keeping the other two variables constant thus allowing for the first time, a distinct separation of these three important variables. A description of the NTF emphasizing its flow quality features, details on the calibration of the instrumentation, results of measurements with the test section slots covered, downstream choke, effects of liquid nitrogen injection and gaseous nitrogen venting, comparisons between air and nitrogen, isolation of the effects of Mach number, Reynolds number, and fan drive power, and identification of the sources of significant flow disturbances is included. The results indicate that primary sources of flow disturbance in the NTF may be edge-tones generated by test section sidewall re-entry flaps and the venting of nitrogen gas from the return leg of the tunnel circuit between turns 3 and 4 in the cryogenic mode of operation. The tests to isolate the effects of Mach number, Reynolds number, and drive power indicate that Mach number effects predominate. A comparison with other transonic wind tunnels shows that the NTF has low levels of test section fluctuating static pressure especially in the high subsonic Mach number range from 0.7 to 0.9.

Igoe, William B.↗

Evaluation of the prototype dual-axis wall attitude measurement sensor

A prototype dual-axis electrolytic tilt sensor package for angular position measurements was built and evaluated in a laboratory environment. The objective was to investigate the use of this package for making wind tunnel wall attitude measurements for the National Transonic Facility (NTF) at NASA Langley Research Center (LaRC). The instrumentation may replace an existing, more costly, and less rugged servo accelerometer package (angle-of-attack package) currently in use. The dual-axis electrolytic tilt sensor package contains two commercial electrolytic tilt sensors thermally insulated with NTF foam, all housed within a stainless steel package. The package is actively heated and maintained at 160 F using foil heating elements. The laboratory evaluation consisted of a series of tests to characterize the linearity, repeatability, cross-axis interaction, lead wire effect, step response, thermal time constant, and rectification errors. Tests revealed that the total RMS errors for the x-axis sensor is 0.084 degree, and 0.182 degree for the y-axis sensor. The RMS errors are greater than the 0.01 degree specification required for NTF wall attitude measurements. It is therefore not a viable replacement for the angle-of-attack package in the NTF application. However, with some physical modifications, it can be used as an inexpensive 5-degree range dual-axis inclinometer with overall accuracy approaching 0.01 degree under less harsh environments. Also, the data obtained from the tests can be valuable for wind tunnel applications of most types of electrolytic tilt sensors.

Wong, Douglas T.↗

Development of a model protection and dynamic response monitoring system for the national transonic facility

A state-of-the-art, computerized mode protection and dynamic response monitoring system has been developed for the NASA Langley Research Center National Transonic Facility (NTF). This report describes the development of the model protection and shutdown system (MPSS). A technical description of the system is given along with discussions on operation and capabilities of the system. Applications of the system to vibration problems are presented to demonstrate the system capabilities, typical applications, versatility, and investment research return derived from the system to date. The system was custom designed for the NTF but can be used at other facilities or for other dynamic measurement/diagnostic applications. Potential commercial uses of the system are described. System capability has been demonstrated for forced response testing and for characterizing and quantifying bias errors for onboard inertial model attitude measurement devices. The system is installed in the NTF control room and has been used successfully for monitoring, recording and analyzing the dynamic response of several model systems tested in the NTF.

Young, Clarence P., Jr.↗

Computer model to simulate testing at the National Transonic Facility

A computer model has been developed to simulate the processes involved in the operation of the National Transonic Facility (NTF), a large cryogenic wind tunnel at the Langley Research Center. The simulation was verified by comparing the simulated results with previously acquired data from three experimental wind tunnel test programs in the NTF. The comparisons suggest that the computer model simulates reasonably well the processes that determine the liquid nitrogen (LN2) consumption, electrical consumption, fan-on time, and the test time required to complete a test plan at the NTF. From these limited comparisons, it appears that the results from the simulation model are generally within about 10 percent of the actual NTF test results. The use of actual data acquisition times in the simulation produced better estimates of the LN2 usage, as expected. Additional comparisons are needed to refine the model constants. The model will typically produce optimistic results since the times and rates included in the model are typically the optimum values. Any deviation from the optimum values will lead to longer times or increased LN2 and electrical consumption for the proposed test plan. Computer code operating instructions and listings of sample input and output files have been included.

Mineck, Raymond E.↗

Model Deformation Measurement Technique NASA Langley HSR Experiences

Model deformation measurement techniques have been investigated and developed at NASA's Langley Research Center. The current technique is based upon a single video camera photogrammetric determination of two dimensional coordinates of wing targets with a fixed (and known) third dimensional coordinate, namely the spanwise location. Variations of this technique have been used to measure wing twist and bending at a few selected spanwise locations near the wing tip on HSR models at the National Transonic Facility, the Transonic Dynamics Tunnel, and the Unitary Plan Wind Tunnel. Automated measurements have been made at both the Transonic Dynamics Tunnel and at Unitary Plan Wind Tunnel during the past year. Automated measurements were made for the first time at the NTF during the recently completed HSR Reference H Test 78 in early 1996. A major problem in automation for the NTF has been the need for high contrast targets which do not exceed the stringent surface finish requirements. The advantages and limitations (including targeting) of the technique as well as the rationale for selection of this particular technique are discussed. Wing twist examples from the HSR Reference H model are presented to illustrate the run-to-run and test-to-test repeatability of the technique in air mode at the NTF. Examples of wing twist in cryogenic nitrogen mode at the NTF are also presented.

Burner, A. W.↗

Effects of Active Sting Damping on Common Research Model Data Quality

Recent tests using the Common Research Model (CRM) at the Langley National Transonic Facility (NTF) and the Ames 11-foot Transonic Wind Tunnel (11' TWT) produced large sets of data that have been used to examine the effects of active damping on transonic tunnel aerodynamic data quality. In particular, large statistically significant sets of repeat data demonstrate that the active damping system had no apparent effect on drag, lift and pitching moment repeatability during warm testing conditions, while simultaneously enabling aerodynamic data to be obtained post stall. A small set of cryogenic (high Reynolds number) repeat data was obtained at the NTF and again showed a negligible effect on data repeatability. However, due to a degradation of control power in the active damping system cryogenically, the ability to obtain test data post-stall was not achieved during cryogenic testing. Additionally, comparisons of data repeatability between NTF and 11-ft TWT CRM data led to further (warm) testing at the NTF which demonstrated that for a modest increase in data sampling time, a 2-3 factor improvement in drag, and pitching moment repeatability was readily achieved not related with the active damping system.

Acheson, Michael J.↗

A Description of the Development, Capabilities, and Operational Status of the Test SLATE Data Acquisition System at the National Transonic Facility

The paper will present a brief background of the previous data acquisition system at the National Transonic Facility (NTF) and the reasoning and goals behind the upgrade to the current Test SLATE (Test Software Laboratory and Automated Testing Environments) data acquisition system. The components, performance characteristics, and layout of the Test SLATE system within the NTF control room will be discussed. The development, testing, and integration of Test SLATE within NTF operations will be detailed. The operational capabilities of the system will be outlined including: test setup, instrumentation calibration, automatic test sequencer setup, data recording, communication between data and facility control systems, real time display monitoring, and data reduction. The current operational status of the Test SLATE system and its performance during recent NTF testing will be highlighted including high-speed, frame-by-frame data acquisition with conditional sampling post-processing applied. The paper concludes with current development work on the system including the capability for real-time conditional sampling during data acquisition and further efficiency enhancements to the wind tunnel testing process.

Cramer, Christopher J.↗

2 mm GISMO Observations of the Galactic Center. II. A Nonthermal Filament in the Radio Arc and Compact Sources

We have used the Goddard IRAM 2 Millimeter Observer (GISMO) with the 30 m IRAM telescope to carry out a 2 mm survey of the Galaxy’s central molecular zone. These observations detect thermal emission from cold interstellar medium dust, thermal free–free emission from ionized gas, and nonthermal synchrotron emission from relatively flat-spectrum sources. Archival data sets spanning 3.6 μm–90 cm are used to distinguish different emission mechanisms. After the thermal emission of dust is modeled and subtracted, the remaining 2 mm emission is dominated by free–free emission, with the exception of the brightest nonthermal filament (NTF) that runs through the middle of the bundle of filaments known as the Radio Arc. This is the shortest wavelength at which any NTF has been detected. The GISMO observations clearly trace this NTF over a length of ∼0°. 2, with a mean 2 mm spectral index that is steeper than at longer wavelengths. The 2 mm–6 cm (or 20 cm) spectral index steepens from α ≈ −0.2 to −0.7 as a function distance from the Sickle H II region, suggesting that this region is directly related to the NTF. A number of unresolved (at 21″) 2 mm sources are found nearby. One appears to be thermal dust emission from a molecular cloud that is associated with an enigmatic radio point source whose connection to the Radio Arc is still debated. The morphology and colors at shorter IR wavelengths indicate other 2 mm unresolved sources are likely to be compact H II regions.

Staguhn, Johannes↗

Cryogenic Angle Measurement at NASA Langley

NASA’s National Transonic Facility is one of the few cryogenic wind-tunnel facilities in the world, where tunnel conditions may reach -250 F. Model angle of attack (AoA) at NTF is typically measured by an on-board accelerometer package that is exposed to the cryogenic tunnel conditions. These NTF AoA packages house two Q-Flex accelerometers in a compact heated environment in order to maintain constant temperature of the sensors for stability. Recently, drift in sensor output was observed in one of the NTF AoA packages. The drift is correlated with the AoA package temperature and cryogenic soak time. This paper studies the temperature and time dependent behavior of the NTF AoA packages, and reviews their design and calibration. Recommended improvements to the AoA packages are made to improve the stability of the model angle of attack measurements at cryogenic conditions.

Toro, Kenneth G.↗

Additional Findings from the Common Research Model Natural Laminar Flow Wind Tunnel Test

An experimental investigation of the Common Research Model with Natural Laminar Flow (CRM-NLF) took place in the National Transonic Facility (NTF) at the NASA Langley Research Center in 2018. The 5.2% scale semispan model was designed using a new natural laminar flow design method, Crossflow Attenuated NLF (CATNLF). CATNLF enables laminar flow on typical transport wings with high sweep and Reynolds number by reshaping the wing airfoils to obtain specific pressure distribution characteristics that control the crossflow growth near the leading edge. The CATNLF method also addresses Tollmien- Schlichting transition, attachment line transition, and Görtler vortices. During the wind tunnel test, data were acquired to address three primary test objectives: validate the CATNLF design method, characterize the NTF laminar flow testing capabilities, and establish best practices for laminar flow wind tunnel testing. The present paper provides both experimental and computational data to understand the CRM-NLF laminar flow characteristics, as well as address the three primary test objectives. The effects of angle of attack and Reynolds number on the CRM-NLF laminar flow extent are studied, and the dominant transition mechanism is evaluated at a variety of test conditions. Critical N-factors are calculated for the NTF environment, and a discussion on best practices for laminar flow wind tunnel testing is provided. The CRM-NLF in the NTF provided initial confirmation of the ability of the CATNLF method to suppress crossflow growth and enable significant extents of laminar flow on transport wings with high sweep and Reynolds numbers.

Lynde, Michelle N.↗

Extraction chromatography of 225 Ac and lanthanides on N,N-dioctyldiglycolamic acid /1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide solvent impregnated resin

The alpha-emitter 225 Ac (t 1/2 = 9.92 d) is currently under development for targeted alpha-particle therapy of cancer, and accelerator production of 225 Ac via proton irradiation of thorium targets requires robust separations of 225 Ac from chemically similar fission product lanthanides. Additionally, the lanthanide elements represent critical components in modern technologies, and radiolanthanides such as 140 Nd (t 1/2 = 3.37 d) also have potential application in the field of nuclear medicine. The ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([Bmim][NTf 2 ]), combined with the diglycolamide extractant, N,N-dioctyldiglycolamic acid (DODGAA), was adsorbed on macroporous resin support to produce a solvent impregnated resin (SIR) that was investigated for separations of 225 Ac and lanthanides. The equilibrium distribution coefficients (Kd) of the rare earth elements (Sc(III), Y(III), Ln(III)), 225 Ac(III), Th(IV), and U(VI) on the prepared DODGAA/[Bmim][NTf 2 ]-SIR were determined from batch adsorption experiments in HCl and HNO 3 media. The DODGAA/[Bmim][NTf2]-SIR exhibited preferential uptake of the heavier lanthanide elements while allowing for the separation of the lighter lanthanides. Column separations utilizing the DODGAA/[Bmim][NTf 2 ]-SIR were effective at separating the lighter lanthanides from each other, and separating 225 Ac from a mixture of lanthanides, 213 Bi, and 225 Ra without the need for additional complexing agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plenum response to simulated disturbances of the model and fan inlet guide vanes in a transonic tunnel

In order to aid in the design of the National Transonic Facility (NTF) control system, test section/plenum response studies were carried out in a 0.186 scale model of the NTF high speed duct. Two types of disturbances, those induced by the model and those induced by the compressor inlet guide vanes were simulated. Some observations with regard to the test section/plenum response tests are summarized as follows. A resonance frequency for the test section/plenum area of the tunnel of approximately 50 Hz was observed for Mach numbers from 0.40 to 0.90. However, since the plenum is 3.1 times (based on volume) too large for the scaled size of the test section, care must be taken in extrapolating these data to NTF conditions. The plenum pressure data indicate the existence of pressure gradients in the plenum. The test results indicate that the difference between test section static pressure and plenum pressure is dependent on test section flow conditions. Plenum response to inlet guide vane type disturbances appears to be slower than plenum response to test section disturbances.

Gloss, B. B.↗

Description of 0.186-scale model of high-speed duct of national transonic facility

The National Transonic Facility (NTF) is a pressurized cryogenic wind tunnel with a 2.5 m square test section. A 0.186-scale model of the NTF was used to simulate the aerodynamic performance of the components of the high-speed duct of the NTF. These components consist of a wide-angle diffuser, settling chamber, contraction section, test section, model support section, and high-speed diffuser. The geometry of the model tunnel, referred to as the diffuser flow apparatus is described, and some of its operating characteristics are presented.

Gentry, C. L., Jr.↗

Guide for users of the National Transonic Facility

The National Transonic Facility (NTF) is a fan-driven, closed-circuit, continuous flow, pressurized wind tunnel. The test section is 2.5 m x 2.5 m and 7.62 m long with a slotted-wall configuration. The NTF will have a Mach number range from 0.2 to 1.2, with Reynolds number up to 120 10 to the sixth power at Mach 1 (based on a reference length of 0.25 m). The pressure range for the facility will be from 1 to about 9 bars (1 ban = 100 kPa), and the temperature can be varied from 340 to 78 K. This report provides potential users of the NTF with the information required for preliminary planning to test programs and for preliminary layout of models and model supports which may be used in such programs.

Fuller, D. E.↗