Search NASA⌕ Search

SEARCH · Search NASA

Results for “Near Infrared Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Requirements for Portable Instrument Suites during Human Scientific Exploration of Mars

Human explorers on the surface of Mars will have access to a far wider array of scientific tools than previous crewed planetary exploration missions, but not every tool will be compatible with the restrictions of this exploration. Spectrometers on flyby, orbital, and landed missions are currently used to determine the composition and mineralogy of geological materials of various types and sizes, from small fragments to celestial bodies in the solar system. Handheld spectrometers that are capable of in situ analyses are already used for geological exploration on Earth; however, their usefulness for human exploration missions and how data from multiple handheld instruments could be combined to enhance scientific return must be further evaluated. As part of the Biologic Analog Science Associated with Lava Terrains (BASALT) research project, we incorporated two handheld instruments, a visible-near infrared spectrometer and an X-Ray Fluorescence spectrometer, into simulated Mars exploration missions conducted on basaltic terrains in Idaho and Hawai'i. To understand the data quality provided by these handheld spectrometers, we evaluated their performance under varying conditions of measurement time, distance, angle, atmosphere, and sample matrix, and we compared data quality between handheld instruments and laboratory techniques. Here, we summarize these findings, provide guidelines and requirements on how to effectively incorporate these instruments into human exploration missions to Mars, and posit that future iterations of these instruments will be beneficial for enhancing science returned from human exploration missions.

Alexander Sehlke↗

The Compositional Evolution of C/2012 S1 (ISON) from Ground-Based High-Resolution Infrared Spectroscopy as Part of a Worldwide Observing Campaign

Volatile production rates, relative abundances, rotational temperatures, and spatial distributions in the coma were measured in C/2012 S1 (ISON) using long-slit high-dispersion (lambda/delta lambda approximately 2.5 times 10 (sup 4)) infrared spectroscopy as part of a worldwide observing campaign. Spectra were obtained on Universal Time 2013 October 26 and 28 with NIRSPEC (Near Infrared Spectrometer) at the W.M. Keck Observatory, and Universal Time 2013 November 19 and 20 with CSHELL (Cryogenic Echelle Spectrograph) at the NASA IRTF (Infrared Telescope Facility). H2O was detected on all dates, with production rates increasing markedly from (8.7 plus or minus 1.5) times 10 (sup 27) molecules per second on October 26 (Heliocentric Distance = 1.12 Astronomical Units) to (3.7 plus or minus 0.4) times 10 (sup 29) molecules per second on November 20 (Heliocentric Distance = 0.43 Astronomical Units). Short-term variability of H2O production is also seen as observations on November 19 show an increase in H2O production rate of nearly a factor of two over a period of about 6 hours. C2H6, CH3OH and CH4 abundances in ISON (International Scientific Optical Network) are slightly depleted relative to H2O when compared to mean values for comets measured at infrared wavelengths. On the November dates, C2H2, HCN and OCS abundances relative to H2O appear to be within the range of mean values, whereas H2CO and NH3 were significantly enhanced. There is evidence that the abundances with respect to H2O increased for some species but not others between October 28 (Heliocentric Distance = 1.07 Astronomical Units) and November 19 (Heliocentric Distance = 0.46 Astronomical Units). The high mixing ratios of H2CO to CH3OH and C2H2 to C2H6 on November 19, and changes in the mixing ratios of some species with respect to H2O between October 28 to November 19, indicates compositional changes that may be the result of a transition from sampling radiation-processed outer layers in this dynamically new comet to sampling more pristine natal material as the outer processed layer was increasingly eroded and the thermal wave propagated into the nucleus as the comet approached perihelion for the first time. On November 19 and 20, the spatial distribution for dust appears asymmetric and enhanced in the antisolar direction, whereas spatial distributions for volatiles (excepting CN) appear symmetric with their peaks slightly offset in the sunward direction compared to the dust. Spatial distributions for H2O, HCN, C2H6, C2H2, and H2CO on November 19 show no definitive evidence for significant contributions from extended sources; however, broader spatial distributions for NH3 and OCS may be consistent with extended sources for these species. Abundances of HCN and C2H2 on November 19 and 20 are insufficient to account for reported abundances of CN and C2 in ISON near this time. Differences in HCN and CN spatial distributions are also consistent with HCN as only a minor source of CN in ISON on November 19 as the spatial distribution of CN in the coma suggests a dominant distributed source that is correlated with dust and not volatile release. The spatial distributions for NH3 and NH2 are similar, suggesting that NH3 is the primary source of NH2 with no evidence of a significant dust source of NH2; however, the higher production rates derived for NH3 compared to NH2 on November 19 and 20 remain unexplained. This suggests a more complete analysis that treats NH2 as a distributed source and accounts for its emission mechanism is needed for future work.

Russo, N. Dello↗

MEMS Microshutter Array System for James Webb Space Telescope

A complex MEMS microshutter array system has been developed at NASA Goddard Space Flight Center (GSFC) for use as a multi-object aperture array for a Near-Infrared Spectrometer (NIRSpec). The NIRSpec is one of the four major instruments carried by the James Webb Space Telescope (JWST), the next generation of space telescope after the Hubble Space Telescope retires. The microshutter arrays (MSAs) are designed for the selective transmission of light with high efficiency and high contrast. It is demonstrated in Figure 1 how a MSA is used as a multiple object selector in deep space. The MSAs empower the NIRSpec instrument simultaneously collect spectra from more than 100 targets therefore increases the instrument efficiency 100 times or more. The MSA assembly is one of three major innovations on JWST and the first major MEMS devices serving observation missions in space. The MSA system developed at NASA GSFC is assembled with four quadrant fully addressable 365x171 shutter arrays that are actuated magnetically, latched and addressed electrostatically. As shown in Figure 2, each MSA is fabricated out of a 4' silicon-on-insulator (SOI) wafer using MEMS bulk-micromachining technology. Individual shutters are close-packed silicon nitride membranes with a pixel size close to 100x200 pm (Figure 3). Shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. In order to prevent light leak, light shields are made on to the surrounding frame of each shutter to cover the gaps between the shutters and the Game (Figure 4). Micro-ribs and sub-micron bumps are tailored on hack walls and light shields, respectively, to prevent sticktion, shown in Figures 4 and 5. JWST instruments are required to operate at cryogenic temperatures as low as 35K, though they are to be subjected to various levels of ground tests at room temperature. The shutters should therefore maintain nearly flat in the entire temperature range between 35K and 300K. Through intensive numerical simulations and experimental studies, an optically opaque and electrically conductive metal-nitride thin film was selected as a coating material deposited on the shutters with the best thermal-expansion match to silicon nitride - the shutter blade thin film material. A shutter image shown in Figure 6 was taken at room temperature, presenting shutters slightly bowing down as expected. Shutters become flat when the temperature decreases to 35K. The MSAs are then bonded to silicon substrates that are fabricated out of 6" single-silicon wafers in the thickness of 2mm. The bonding is conducted using a novel single-sided indium flip-chip bonding technology. Indium bumps fabricated on a substrate are shown in Figure 7. There are 180,000 indium bumps for bonding a flight format MSA array to its substrate. Besides a MSA, each substrate houses five customer-designed ASIC (Application Specific Integrated Circuit) multiplexer/address chips for 2-dimensional addressing, twenty capacitors, two temperature sensors, numbers of resistors and all necessary interconnects, as shown in Figure 8. Complete MSA quadrant assemblies have been successfully manufactured and fully functionally tested. The assemblies have passed a series of critical reviews required by JWST in satisfying all the design specifications. The qualification tests cover programmable 2-D addressing, life tests, optical contrast tests, and environmental tests including radiation, vibration, and acoustic tests. A 2-D addressing pattern with 'ESA' letters programmed in a MSA is shown in Figure 9. The MSAs passed 1 million cycle life tests and achieved high optical contrast over 10,000. MSA teams are now making progress in final fabrication, testing and assembly (Figure 10). The delivery of flight-format MSA system is scheduled at the end of 2008 for being integrated to the focal plane of the NIRSpec detectors.

Li, Mary J.↗

Radiation Test Results for a MEMS Microshutter Operating at 60 K

The James Webb Space Telescope (JWST), the successor to the Hubble Space Telescope, is due to be launched in 2013 with the goal of searching the very distant Universe for stars that formed shortly after the Big Bang. Because this occurred so far back in time, the available light is strongly red-shifted, requiring the use of detectors sensitive to the infrared portion of the electromagnetic spectrum. HgCdTe infrared focal plane arrays, cooled to below 30 K to minimize noise, will be used to detect the faint signals. One of the instruments on JWST is the Near Infrared Spectrometer (NIRSPEC) designed to measure the infrared spectra of up to 100 separate galaxies simultaneously. A key component in NIRSPEC is a Micro-Electromechanical System (MEMS), a two-dimensional micro-shutter array (MSA) developed by NASA/GSFC. The MSA is inserted in front of the detector to allow only the light from the galaxies of interest to reach the detector and to block the light from all other sources. The MSA will have to operate at 30 K to minimize the amount of thermal radiation emitted by the optical components from reaching the detector array. It will also have to operate in the space radiation environment that is dominated by the MSA will be exposed to a large total ionizing dose of approximately 200 krad(Si). Following exposure to ionizing radiation, a variety of MEMS have exhibited performance degradation. MEMS contain moving parts that are either controlled or sensed by changes in electric fields. Radiation degradation can be expected for those devices where there is an electric field applied across an insulating layer that is part of the sensing or controlling structure. Ionizing radiation will liberate charge (electrons and holes) in the insulating layers, some of which may be trapped within the insulating layer. Trapped charge will partially cancel the externally applied electric field and lead to changes in the operation of the MEMS. This appears to be a general principle for MEMS. Knowledge of the above principle has raised the concern at NASA that the MSA might also exhibit degraded performance because, i) each shutter flap is a multilayer structure consisting of metallic and insulating layers and ii) the movement of the shutter flaps is partially controlled by the application of an electric field between the shutter flap and the substrate (vertical support grid). The whole mission would be compromised if radiation exposure were to prevent the shutters from opening and closing properly. energetic ionizing particles. Because it is located A unique feature of the MSA is that, as outside the spacecraft and has very little shielding, previously mentioned, it will have to operate at temperatures near 30 K. To date, there are no published reports on how very low temperatures (- 30K) affect the response of MEMS devices to total ionizing dose. Experiments on SiO2 structures at low temperatures (80 K) indicate that the electrons generated by the ionizing radiation are mobile and will move rapidly under the application of an external electric field. Holes, on the other hand, that would normally move in the opposite direction through the SiO2 via a "thermal hopping" process, are effectively immobile at low electric fields as they are trapped close to their generation sites. However, for sufficiently large electric fields (greater than 3 MV/cm) holes are able to move through the SiO2. The larger the field, the more rapidly the holes move. The separation of the electrons and holes leads to a reduced electric field within the insulating layer. To overcome this reduction in electric field, a greater external voltage will have to be applied that alters the normal operation of the device. This report presents the results of radiation testing of the MSA at 60 K. The temperature was higher than the targeted temperature because of a faulty electrical interconnect on the test board. Specifically, our goal was to determine whether the MSA would function propey after a TID of 200 krad(Si).

Rapchun, David A.↗

The Cassini mission: Infrared and microwave spectroscopic measurements

The Cassini Orbiter and Titan Probe model payloads include a number of infrared and microwave instruments. This document describes: (1) the fundamental scientific objectives for Saturn and Titan which can be addressed by infrared and microwave instrumentation, (2) the instrument requirements and the accompanying instruments, and (3) the synergism resulting from the comprehensive coverage of the total infrared and microwave spectrum by the complement of individual instruments. The baseline consists of four instruments on the orbiter and two on the Titan probe. The orbiter infrared instruments are: (1) a microwave spectrometer and radiometer; (2) a far to mid-infrared spectrometer; (3) a pressure modulation gas correlation spectrometer, and (4) a near-infrared grating spectrometer. The two Titan probe infrared instruments are: (1) a near-infrared instrument, and (2) a tunable diode laser infrared absorption spectrometer and nephelometer.

Kunde, V. G.↗

Near-infrared linear array spectrometer for space applications

A 128-element InSb linear detector array read out with a field effect transistor (FET) multiplexing scheme has been developed at the Jet Propulsion Laboratory. State-of-the-art NEP, uniform response, on-detector charge integration, and very low focal plane heat load compared to that of discrete detector arrays allows this type of array to open new possibilities for spaceborne near-infrared imaging spectrometers. Large number of cooled detector elements are feasible with the new technology, making it practical to design sensitive spectrometers even for spinning spacecraft where simultaneous wavelength coverage is necessary to avoid confusion of spatial with spectral variations.

Apt, J.↗

Evaluating the Thickness and Stratigraphy of Ejecta Materials at the Chang’e-4 Landing Site

The landing site of China’s Chang’e-4 (CE-4) probe is located on the mare basalts on the floor of the Von Kármán crater on the lunar far side. The Von Kármán crater is inside the ancient and highly cratered South Pole–Aitken basin, which has experienced complex emplacement sequences of both near and distant ejecta materials. These issues complicated the interpretation of the CE-4 surface in situ measurements of the visible and near-infrared spectrometer and the lunar penetrating radar (LPR) onboard Yutu-2 rover. To evaluate the sources and amounts of all principle foreign materials at the CE-4 landing site, we thoroughly examine the ejecta delivered by crater-forming events that occurred later than the formation of the mare basalts at the CE-4 landing site. We found a total of 16 craters that may have delivered ejecta thicker than 10 cm level superposed on the mare basalts at the CE-4 landing site. Crater Finsen, Von Kármán L, Von Kármán L′, and Maksutov are the top four major foreign material sources, and each of them contributed ejecta thicker than 1 m. Our surveys confirm that the ejecta from Finsen crater are the most dominant foreign materials in the uppermost few meters at the CE-4 landing site and the total impact ejecta deposited upon the mare basalts at the landing site is estimated to be thinner than 30 m. We found that the estimations from Pike’s model are the most consistent with the Yutu-2 LPR observations.

58 GEOSCIENCES↗

IRTS observation of zodiacal light and emission

We present the infrared spectrum of the zodiacal light and emission obtained by the Near-Infrared Spectrometer (NIRS) and Mid-Infrared Spectrometer (MIRS) onboard the Infrared Telescope in Space (IRTS). The wavelength coverages and spectral resolutions are 1.4-4.0 microns and 0.12 microns for the NIRS, and 4.5-11.7 microns and 0.23-0.36 microns for the MIRS respectively. Both instruments have the same beam size of 8 arcminutes square. The IRTS observations were made for 1995 March 29 - April 26. Here we present the data of two days, April 19 and April 20.

Matsumoto, T.↗

Observations of 433 Eros from 1.25 to 3.35 Microns

We have spectrophotometrically observed 433 Eros, the target of the Near Earth Asteroid Rendezvous (NEAR)-Shoemaker spacecraft, on 1995 December 4 from 1.25 to 3.35 microns. As expected, Eros shows no evidence of an absorption feature over 5% in the 3-micron region, and is interpreted to have an anhydrous surface within observational uncertainties. Our observations in the JHK region agree with previous work by Chapman and Morrison and Murchic and Pieters, but differ from the near-infrared spectrometer spectra reported by Clark et al. Our calculations indicate that thermal flux from Eros is not responsible for this mismatch.

Rivkin, A. S.↗

Thermal-Stress Control of Microshutter Arrays in Cryogenic Applications for the James Webb Space Telescope

We report on methods to minimize thermally-induced deformation in a MEMS-based reconfigurable aperture. The device is an enabling component of the Near-Infrared Spectrometer, a principle instrument on NASA's James Webb Space Telescope. The Microshutter Array consists of 384 x 175 individually addressable shutters which can be magnetically rotated 90 deg into the plane of the array and electrostatically latched open. Each shutter is a 100 x 200 micron rectangular membrane suspended by a small neck region and torsion flexure. The primary materials in the shutter are a 5000A Si3N4 layer for mechanical rigidity, 2000A Al for opacity and electrostatic latching, and 2800A CoFe for magnetic actuation. This multi-layer stack presents a challenge due to the operating temperatures required for the device: both room temperature (300K) and cryogenic temperature (35K). Thermal expansion of the materials causes the shutters to bow out of plane excessively, which can prevent actuation of the shutters, cause damage to portions of the array, and allow light leakage around closed shutters. Here we present our investigation of several methods to prevent microshutter bowing including deposition of additional materials on the shutters to create a symmetrical layer stack and replacing the current stack with low-coefficient of thermal expansion materials. Using shutter-size suspended cantilever beams as a rapid-development test bed, we have reduced out-of-plane bowing between 300K and 35K to 10% or better. We are currently applying these results to microshutter arrays to develop shutters that remain flat from room temperature to cryogenic temperature while retaining the required mechanical, optical, and magnetic properties.

Kelly, Daniel P.↗

JWST NIRSpec Cryogenic Light Shield Mechanism

The focal plane detectors for the Near-Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST) require a light tight cover for calibration along with an open field-of-view during g round performance testing within a cryogenic dewar. In order to meet the light attenuation requirements and provide open and closed fields of view without breaking vacuum, a light shield mechanism was designe d. This paper describes the details of the light shield mechanism design and test results. Included is information on the labyrinth light p ath design, motor capability and performance, dry film lubrication, m echanism control, and mechanism cryogenic performance results.

Hale, Kathleen↗

Reducing Stray Light To Characterize Nirspec Subsystems: The Focal Plane Array And Micro-Shutter Array

The James Webb Space Telescope (JWST) is an infrared, space-based telescope scheduled for launch in 2013. JWST includes four scientific instruments, including the Near Infrared Spectrometer (NIRSpec), which operates in the wavelength range from 0.6 to 5 microns. NASA/Goddard Space Flight Center (GSFC) is responsible for two NIRSpec subsystems: the detector subsystem, with its focal plane array (FPA), and the micro-shutter subsystem, with its micro-shutter array (MSA). The FPA is comprised of two side-by-side Rockwell Scientific HgCdTe 2kx2k detectors, with detectors and readout electronics optimized for low noise. The MSA is a GSFC developed micro-electro-mechanical system (MEMS) that serves as a programmable slit mask, allowing NIRSpec to obtain simultaneous spectra of >100 objects in a single field of view. We present the optical characterization test plan of the FPA. The test plan is driven by many requirements: cryogenic operating temperature, a flight-like beam shape, and multi-wavelength photon flux from 1 to 60,000 per second, thus low stray light is critical. We use commercial optical modeling software to predict stray light effects at the FPA. We also present the optical contrast test plan of the MSA. Since each individual shutter element operates in on/off fashion, the most important optical metric is contrast. The MSA structure is designed to minimize stray and scattered light, and the test setup reduces stray light such that the optical contrast requirement is met.

Connelly, Joseph A.↗

JWST NIRSpec Cryogenic Light Shield Mechanism

The focal plane detectors for the Near-Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST) require a light tight cover for calibration along with an open field-of-view during ground performance testing within a cryogenic dewar. In order to meet the light attenuation requirements and provide open and closed fields of view without breaking vacuum, a light shield mechanism was designed. This paper describes the details of the light shield mechanism design and test results. Included is information on the labyrinth light path design, motor capability and performance, dry film lubrication, mechanism control, and mechanism cryogenic performance results.

Hale, Kathleen↗

MEMS Microshutter Arrays for James Webb Space Telescope

MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use as an aperture array for a Near-Infrared Spectrometer (NirSpec). The instruments will be carried on the James Webb Space Telescope (JWST), the next generation of space telescope after Hubble Space Telescope retires. The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast, Arrays are close-packed silicon nitride membranes with a pixel size of 100x200 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. Light shields are made on to each shutter for light leak prevention so to enhance optical contrast, Shutters are actuated magnetically, latched and addressed electrostatically. The shutter arrays are fabricated using MEMS technologies.

Li, Mary J.↗

Microshutter Arrays for the JWST NIRSpec

A primary goal of the James Webb Space Telescope (JWST) is to characterize the birth and evolution of galaxies by imaging and spectroscopic observations. The telescope will use a Near Infrared Camera and a Near Infrared Spectrometer (NIRSpec) to carry out this program. The 3.6 x 3.6 field of NIRSpec will contain thousands of candidate high redshift galaxies. With such a high candidate object density, simultaneous multi-object capability is essential. This capability requires a programmable object selection mask to eliminate sky background and to reduce source confusion caused. We are developing a two-dimensional programmable field mask for NIRSpec. These masks employ micromechanical (MEMS) techniques to provide source selection over the NIRSpec field of view. The first flight format arrays (171x365 shutters) have been fabricated and full functionality of these arrays has been demonstrated in lab tests. Qualification tests are in progress to demonstrate readiness for flight, and will be complete in the early fall of 2006. In this paper, I describe performance of this critical new technology, and progress in making the devices ready for a 2008 delivery to ESA for inclusion in the NIRSpec.

Moseley, Samuel H.↗

JWST NIRSpec Cryogenic Light Shield Mechanism

The focal plane detectors for the Near-Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST) require a light tight cover for calibration as well as an open field-of-view during ground performance testing within a cryogenic dewar. In order to achieve the light attenuation requirements when closed as well as provide a open field of view for the detectors within the cryogenic dewar, a light shield mechanism was designed. This paper discusses the details of the light shield mechanism design, development, and test results.

Sharma, Rajeev K.↗

James Webb Space Telescope Project (JWST) Overview

This presentation provides an overview of the James Webb Space Telescope (JWST) Project. The JWST is an infrared telescope designed to collect data in the cosmic dark zone. Specifically, the mission of the JWST is to study the origin and evolution of galaxies, stars and planetary systems. It is a deployable telescope with a 6.5 m diameter, segmented, adjustable primary mirror. outfitted with cryogenic temperature telescope and instruments for infrared performance. The JWST is several times more sensitive than previous telescope and other photographic and electronic detection methods. It hosts a near infrared camera, near infrared spectrometer, mid-infrared instrument and a fine guidance sensor. The JWST mission objection and architecture, integrated science payload, instrument overview, and operational orbit are described.

Dutta, Mitra↗

Contrast Measurements of the Microshutter Arrays for the NIRspec

We have been developing programmable microshutter arrays for the Near Infrared Spectrometer (NIRSpec) on the James Webb Space telescope (JWST). These arrays are an enabling technology that allows to turn NIRSpec into a powerful multi-object spectrometer and tremendously increase its efficiency. The arrays are essentially 2D programmable masks that are designed to operate at cryogenic temperatures of JWST. The primary optical characteristic of the microshutter array is a contrast, that is defined as a ratio of the transmitted light intensity through open shutters to the intensity of the transmitted light through the closed shutters. To eliminate the noise and confusion from other sources in the field of view and therefore to improve the detection limit, the contrast provided by the microshutter array should be very high, with the goal of 10,000. The test system that we have developed specifically for the purpose of the high contrast characterization of the microshutter array devices has been used to test several microshutter arrays. It is capable of measuring contrast values of up to 10^5 and therefore can reliably measure contrast values of the arrays that satisfy the requirements. The arrays have been characterized for the contrast ratio and its behavior with temperature and other array operating parameters. The arrays that we have tested meet or exceed the NiRSpec requirements.

Kutyrev, Alexander↗