Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neck initiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-E-T-109: Development of An End-To-End Test for the Varian TrueBeamtm with a Novel Multiple-Dosimetric Modality H and N Phantom

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Methods: The initial end-to-end test and custom H and N phantom were designed to yield maximum information in anatomical regions significant to H and N plans with respect to: i) geometric accuracy, ii) dosimetric accuracy, and iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies. A CT image was taken with a 1mm slice thickness. The CT was imported into Varian's Eclipse treatment planning system, where OARs and the PTV were contoured. A clinical template was used to create an eight field static gantry angle IMRT plan. After optimization, dose was calculated using the Analytic Anisotropic Algorithm with inhomogeneity correction. Plans were delivered with a TrueBeam equipped with a high definition MLC. Preliminary end-to-end results were measured using film and ion chambers. Ion chamber dose measurements were compared to the TPS. Films were analyzed with FilmQAPro using composite gamma index. Results: Film analysis for the initial end-to-end plan with a geometrically simple PTV showed average gamma pass rates >99% with a passing criterion of 3% / 3mm. Film analysis of a plan with a more realistic, ie. complex, PTV yielded pass rates >99% in clinically important regions containing the PTV, spinal cord and parotid glands. Ion chamber measurements were on average within 1.21% of calculated dose for both plans. Conclusion: trials have demonstrated that our end-to-end testing methods provide baseline values for the dosimetric and geometric accuracy of Varian's TrueBeam system.

60 APPLIED LIFE SCIENCES↗

SU-E-J-259: Quantification of Rotational Localization Offset in Radiation Therapy

Purpose: To verify the necessity of 6D localization detection and correction in radiation therapy. Methods: An anthropomorphic head and neck phantom was used to test the BrainLab ExacTrac x-ray imaging system. After initial positioning, both ExacTrac and the on-board kV CBCT were used to detect the offset at the same position, using both manual and automatic registration algorithms. Then 6D offset including rotational errors up to 5 degree were introduced. Both ExacTrac and CBCT were used to correct the offsets and the residual errors were evaluated. Finally, 6D offset detected by ExacTrac for a C-Spine patient was reported. Results: The differences in 3D offset detected by ExacTrac and CBCT were 1.5 ± 1.2(Lateral), 2.7 ± 2.7(Vertical), and 4.0 ± 6.3(longitudinal) mm with manual registration while the corresponding differences decreased to 0.6 ± 0.3, 1.0 ± 0.3, and 0.3 ± 0.3 when automatic registration were used. CBCT corrected the translational offset to within 0.5 mm but the rotational errors remained and detected by the ExacTrac system (Yaw=2.1, Roll=1.1, Pitch=1.4 degree). When similar offset was introduced and corrected using ExacTrac, the residual error detected by both CBCT and ExacTrac were within 0.5 mm / 0.5 degree. The average offset from the 112 ExacTrac x-ray corrections for the C-Spine patient was 0.6 ± 1.6 (lateral), 5.4 ± 8(vertical), 1.6±1.1(longitudinal) mm, and 0.7 ± 0.6 (pitch), 0.7 ± 0.4(roll), 1.2 ± 0.7 (yaw) degree. Larger rotational errors, with a maximum of 2.7 degree (corresponds to about 1.5 to 4.5 mm offset for a POI 10 to 30 cm away from the isocenter), were observed when couch rotational were involved. Conclusion: Rotational errors are common in patient localization, especially when couch rotation is involved. Both appropriate imaging system and 6D robotic couch are necessary to detect and correct the rotational localization errors.

60 APPLIED LIFE SCIENCES↗

Patterns of Locoregional Failure After Exclusive IMRT for Oropharyngeal Carcinoma

Purpose: To assess the patterns of failure after intensity-modulated radiotherapy (IMRT) for oropharyngeal squamous cell carcinoma (SCC). Methods and Materials: We analyzed patients treated at the University of Texas Medical Branch between May 2002 and February 2006 who met the following criteria: (1) definitive IMRT without chemotherapy for oropharyngeal SCC; (2) no pretreatment radical surgery; (3) minimal follow-up of 1 year. The location of each nodal/primary failure was co-registered to the pretreatment planning computed tomography scan and then expanded by 5 mm to a planning target volume (PTV) of the failure (PTV-f). We then investigated whether the prescription dose to the PTV-f had been appropriate for the amount of disease present before treatment and whether the PTV-f had been adequately covered. Results: A total of 50 patients were eligible. With a median follow-up of 32.6 months (range, 12.1-58.6), three local and six regional failures were observed in 8 patients. All but one failure, that had been neglected, were recorded within 14 months of the treatment end. Of the nine failures, four developed in the neck treated electively to the lowest dose level; in all of them, we could retrospectively identify initial positive lymph nodes that might have justified the subsequent failure. The remaining five failures developed in proximity of the high-dose volume. In all but one, the volume of region of interest receiving {>=}95% of the dose of the PTV-f was >95%, suggesting adequate coverage. In 1 patient, about 20% of PTV-f was outside the 95% isodose, so that marginal underdosing could not be ruled out. Conclusions: A potential cause could be identified in all the failures in the lowest dose level. The implications and possible remedies are discussed. Most failures around the high-dose region were 'true failures' with no apparent technical caus000.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-Situ TEM Study Of Lithiation Behavior Of Silicon Nanoparticles Attached To And Embedded In A Carbon Matrix

Rational design of silicon and carbon nanocomposite with a special topological feature has been demonstrated to be a feasible way for mitigating the capacity fading associated with the large volume change of silicon anode in lithium ion batteries. Although the lithiation behavior of silicon and carbon as individual component has been well understood, lithium ion transport behavior across a network of silicon and carbon are still lacking. In this paper, we probe the lithiation behavior of silicon nanoparticles attached to and embedded in a carbon nanofiber using in-situ TEM and continuum mechanical calculation. We found that aggregated silicon nanoparticles show contact flattering upon initial lithiation, which is characteristically analogous to the classic sintering of powder particles by neck-growth mechanism. As compared with the surface-attached silicon particle, particles embedded in the carbon matrix show delayed lithiation. Depending on the strength of the carbon matrix, lithiation of the embedded silicon nanoparticle can lead to the fracture of the carbon fiber. These observations provide insights on lithium ion transport in the network structured composite of silicon and carbon, and ultimately provide fundamental guidance for mitigating the failure of battery due to the large volume change of silicon anode.

Environmental Molecular Sciences Laboratory↗

SU-E-T-581: A Comparative Study of Standard IMRT and VMAT Planning Techniques for Unilateral and Bilateral Head and Neck Irradiation

Purpose: To compare dosimetric properties and monitor units (MU) of IMRT plans with several VMAT head and neck (H and N) plans. Methods: Seventeen unilateral H and N (UHN) and five bilateral H and N (BHN) patients initially treated with IMRT were replanned with VMAT. Several arc arrangements were studied for each patient: 1)for UHN, two 360° arcs, two 260° arcs, two 210° arcs, two 360° arcs with contralateral avoidance sectors, and 2)for BHN, two 360° arcs, two 360° arcs with bilateral avoidance sectors, two 360° arcs with bilateral avoidance sectors and a third arc limited to the upper neck. Optimization constraints were adjusted for each patient and plan. All plans were normalized to achieve the same highest-dose PTV coverage. Percent differences (IMRT-VMAT)/VMAT in MU, dose homogeneity (HI=maximum point dose/prescription dose), and organ-at-risk (OAR) metrics are reported and statistical significance evaluated (p<0.05; paired Student t-test). Results: Average reduction in MU with VMAT was 28% for UHN (p<0.0001) and 63% for BHN (p<0.0001). Average HI for UHN IMRT and 360° arc VMAT plans was 1.08 and for plans with arcs <360° average HI=1.10. Average HI for BHN IMRT was 1.07, for three-arc VMAT 1.08, and for two-arc VMAT 1.11. For UHN, two 210° arcs achieved lower contralateral parotid max (−2.6 Gy, p<0.02) and mean (−1.2 Gy, p=0.06) dose. For BHN two-arc plans, contralateral parotid mean dose increased (3.3 Gy, p<0.04) and larynx max dose increased (2.9 Gy, p<0.02) with no change in larynx mean dose. Conclusion: For UHN, 360degree arc VMAT consistently produced plans dosimetrically comparable to IMRT with the benefit of lower MU. VMAT with arcs <360degrees produced plans inferior to IMRT in dose homogeneity and without significantly improved OAR sparing. For BHN, three-arc plans were dosimetrically comparable to IMRT with lower MU, while two-arc plans were inferior to IMRT in HI and OAR dose. Research supported in part by a Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy?

This study aimed to quantify dosimetric effects of weight loss for nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Overall, 25 patients with NPC treated with IMRT were enrolled. We simulated weight loss during IMRT on the computer. Weight loss model was based on the planning computed tomography (CT) images. The original external contour of head and neck was labeled plan 0, and its volume was regarded as pretreatment normal weight. We shrank the external contour with different margins (2, 3, and 5 mm) and generated new external contours of head and neck. The volumes of reconstructed external contours were regarded as weight during radiotherapy. After recontouring outlines, the initial treatment plan was mapped to the redefined CT scans with the same beam configurations, yielding new plans. The computer model represented a theoretical proportional weight loss of 3.4% to 13.7% during the course of IMRT. The dose delivered to the planning target volume (PTV) of primary gross tumor volume and clinical target volume significantly increased by 1.9% to 2.9% and 1.8% to 2.9% because of weight loss, respectively. The dose to the PTV of gross tumor volume of lymph nodes fluctuated from −2.0% to 1.0%. The dose to the brain stem and the spinal cord was increased (p < 0.001), whereas the dose to the parotid gland was decreased (p < 0.001). Weight loss may lead to significant dosimetric change during IMRT. Repeated scanning and replanning for patients with NPC with an obvious weight loss may be necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Validation of a Standardized Method for Contouring the Brachial Plexus: Preliminary Dosimetric Analysis Among Patients Treated With IMRT for Head-and-Neck Cancer

Purpose: Although Radiation Therapy Oncology Group protocols have proposed a limiting dose to the brachial plexus for patients undergoing intensity-modulated radiotherapy for head-and-neck cancer, essentially no recommendations exist for the delineation of this structure for treatment planning. Methods and Materials: Using anatomic texts, radiologic data, and magnetic resonance imaging, a standardized method for delineating the brachial plexus on 3-mm axial computed tomography images was devised. A neuroradiologist assisted with identification of the brachial plexus and adjacent structures. This organ at risk was then contoured on 10 consecutive patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Dose-volume histogram curves were generated by applying the proposed brachial plexus contour to the initial treatment plan. Results: The total dose to the planning target volume ranged from 60 to 70 Gy (median, 70). The mean brachial plexus volume was 33 {+-} 4 cm{sup 3} (range, 25.1-39.4). The mean irradiated volumes of the brachial plexus were 50 Gy (17 {+-} 3 cm{sup 3}), 60 Gy (6 {+-} 3 cm{sup 3}), 66 Gy (2 {+-} 1 cm{sup 3}), 70 Gy (0 {+-} 1 cm{sup 3}). The maximal dose to the brachial plexus was 69.9 Gy (range, 62.3-76.9) and was {>=}60 Gy, {>=}66 Gy, and {>=}70 Gy in 100%, 70%, and 30% of patients, respectively. Conclusions: This technique provides a precise and accurate method for delineating the brachial plexus organ at risk on treatment planning computed tomography scans. Our dosimetric analysis suggest that for patients undergoing intensity-modulated radiotherapy for head-and-neck cancer, brachial plexus routinely receives doses in excess of historic and Radiation Therapy Oncology Group limits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Shape Modeling of Cam Femoroacetabular Impingement

In this study, statistical shape modeling (SSM) was used to quantify three-dimensional (3D) variation and morphologic differences between femurs with and without cam femoroacetabular impingement (FAI). 3D surfaces were generated from CT scans of femurs from 41 controls and 30 cam FAI patients. SSM correspondence particles were optimally positioned on each surface using a gradient descent energy function. Mean shapes for control and patient groups were defined from the resulting particle configurations. Morphological differences between group mean shapes and between the control mean and individual patients were calculated. Principal component analysis was used to describe anatomical variation present in both groups. The first 6 modes (or principal components) captured statistically significant shape variations, which comprised 84% of cumulative variation among the femurs. Shape variation was greatest in femoral offset, greater trochanter height, and the head-neck junction. The mean cam femur shape protruded above the control mean by a maximum of 3.3 mm with sustained protrusions of 2.5-3.0 mm along the anterolateral head-neck junction and distally along the anterior neck, corresponding well with reported cam lesion locations and soft-tissue damage. This study provides initial evidence that SSM can describe variations in femoral morphology in both controls and cam FAI patients and may be useful for developing new measurements of pathological anatomy. SSM may also be applied to characterize cam FAI severity and provide templates to guide patient-specific surgical resection of bone.

statistical shape modeling↗

Clinical Outcomes and Patterns of Disease Recurrence After Intensity Modulated Proton Therapy for Oropharyngeal Squamous Carcinoma

Purpose: A single-institution prospective study was conducted to assess disease control and toxicity of proton therapy for patients with head and neck cancer. Methods and Materials: Disease control, toxicity, functional outcomes, and patterns of failure for the initial cohort of patients with oropharyngeal squamous carcinoma (OPC) treated with intensity modulated proton therapy (IMPT) were prospectively collected in 2 registry studies at a single institution. Locoregional failures were analyzed by using deformable image registration. Results: Fifty patients with OPC treated from March 3, 2011, to July 2014 formed the cohort. Eighty-four percent were male, 50% had never smoked, 98% had stage III/IV disease, 64% received concurrent therapy, and 35% received induction chemotherapy. Forty-four of 45 tumors (98%) tested for p16 were positive. All patients received IMPT (multifield optimization to n=46; single-field optimization to n=4). No Common Terminology Criteria for Adverse Events grade 4 or 5 toxicities were observed. The most common grade 3 toxicities were acute mucositis in 58% of patients and late dysphagia in 12%. Eleven patients had a gastrostomy (feeding) tube placed during therapy, but none had a feeding tube at last follow-up. At a median follow-up time of 29 months, 5 patients had disease recurrence: local in 1, local and regional in 1, regional in 2, and distant in 1. The 2-year actuarial overall and progression-free survival rates were 94.5% and 88.6%. Conclusions: The oncologic, toxicity, and functional outcomes after IMPT for OPC are encouraging and provide the basis for ongoing and future clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study on coalescence dynamics of unequal-sized microbubbles captive on solid substrate

The dynamics of bubble coalescence are of importance for a number of industrial processes, in which the size inequality of the parent bubbles plays a significant role in mass transport, topological change and overall motion. In this study, coalescence of unequal-sized microbubbles captive on a solid substrate was observed from cross-section view using synchrotron high-speed imaging technique and a microfluidic gas generation device. The bridging neck growth and surface wave propagation at the early stage of coalescence were investigated by experimental and numerical methods. The results show that theoretical half-power-law of neck growth rate is still valid when viscous effect is neglected. However, the inertial-capillary time scale is associated with the initial radius of the smaller parent microbubble. Furthermore the surface wave propagation rate on the larger parent microbubble is proportional to the inertial-capillary time scale.

42 ENGINEERING↗

A Clinical Concept for Interfractional Adaptive Radiation Therapy in the Treatment of Head and Neck Cancer

Purpose: To present an approach to fast, interfractional adaptive RT in intensity-modulated radiation therapy (IMRT) of head and neck tumors in clinical routine. Ensuring adequate patient position throughout treatment proves challenging in high-precision RT despite elaborate immobilization. Because of weight loss, treatment plans must be adapted to account for requiring supportive therapy incl. feeding tube or parenteral nutrition without treatment breaks. Methods and Materials: In-room CT position checks are used to create adapted IMRT treatment plans by stereotactic correlation to the initial setup, and volumes are adapted to the new geometry. New IMRT treatment plans are prospectively created on the basis of position control scans using the initial optimization parameters in KonRad without requiring complete reoptimization and thus facilitating quick replanning in daily routine. Patients treated for squamous cell head and neck cancer (SCCHN) in 2006-2007 were evaluated as to necessity/number of replannings, weight loss, dose, and plan parameters. Results: Seventy-two patients with SCCHN received IMRT to the primary site and lymph nodes (median dose 70.4 Gy). All patients received concomitant chemotherapy requiring supportive therapy by feeding tube or parenteral nutrition. Median weight loss was 7.8 kg, median volume loss was approximately 7%. Fifteen of 72 patients required adaptation of their treatment plans at least once. Target coverage was improved by up to 10.7% (median dose). The increase of dose to spared parotid without replanning was 11.7%. Replanning including outlining and optimization was feasible within 2 hours for each patient, and treatment could be continued without any interruptions. Conclusion: To preserve high-quality dose application, treatment plans must be adapted to anatomical changes. Replanning based on position control scans therefore presents a practical approach in clinical routine. In the absence of clinically usable online correction methods, this approach allows significant improvement of target volume coverage and continuous parotid sparing without treatment delays.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial and second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hexapod Robot

The project I am working on at NASA-Johnson Space Center in Houston, TX is a hexapod robot. This project was started by various engineers at the Trick Lab. The goal of this project is to have the hexapod track a yellow ball or possibly another object from left to right and up/down. The purpose is to have it track an object like a real creature. The project will consist of using software and hardware. This project started with a hexapod robot which uses a senor bar to track a yellow ball but with a limited field of vision. The sensor bar acts as the robots "head." Two servos will be added to the hexapod to create flexion and extension of the head. The neck and head servos will have to be programmed to be added to the original memory map of the existing servos. I will be using preexisting code. The main programming language that will be used to add to the preexisting code is C++. The trick modeling and simulation software will also be used in the process to improve its tracking and movement. This project will use a trial and error approach, basically seeing what works and what does not. The first step is to initially understand how the hexapod works. To get a general understanding of how the hexapod maneuvers and plan on how to had a neck and head servo which works with the rest of the body. The second step would be configuring the head and neck servos with the leg servos. During this step, limits will be programmed specifically for the each servo. By doing this, the servo is limited to how far it can rotate both clockwise and counterclockwise and this is to prevent hardware damage. The hexapod will have two modes in which it works in. The first mode will be if the sensor bar does not detect an object. If the object it is programmed to look for is not in its view it will automatically scan from left to right 3 times then up and down once. The second mode will be if the sensor bar does detect the object. In this mode the hexapod will track the object from left to right or up and down. The hexapod will eventually be able to track the object moving its head and body in sync with on another and being able to rotate its body at 360 degrees. This is the plans and possible end results for the hexapod robot I will be working on during my summer internship at NASA Johnson Space Center. Since working on the hexapod project I have gained an increase interest in robotics. I enjoy the process of critical thinking. Also will working on this project I was challenged in a way that made more passionate to strive even more to become an engineer. I've learned that asking questions is an important part of the learning process. Also I learn that much more is accomplished when teamwork is applied.

Begody, Ericka↗

Comparative Analysis of an Image-Guided Versus a Non-Image-Guided Setup Approach in Terms of Delivered Dose to the Parotid Glands in Head-and-Neck Cancer IMRT

Purpose: To assess the impact of interfractional variations of shape and setup uncertainties on the dose to the parotid glands (PGs) in head-and-neck cancer intensity-modulated radiotherapy and image-guided radiotherapy (IGRT). Methods and Materials: Two scenarios were analyzed retrospectively for 10 head-and-neck cancer patients, treated with helical TomoTherapy (TomoTherapy Inc., Madison, WI): the IGRT scenario and the non-IGRT scenario. The initial dose-volume histograms derived from the planning computed tomography (PCT) scan and 120 recalculated dose-volume histograms of the PGs of each scenario and of corresponding fractions were compared. Setup errors, cumulative median doses (CMDs) for 6 fractions, overall volumes of the PGs, and volumes that received less than 1 Gy or more than 1.6 Gy per fraction were analyzed. Results: The mean decrease in the PG volume was 0.13 cm{sup 3}/d. There was a significantly higher CMD than initially predicted (mean increase for 6 fractions, 1.13 Gy for IGRT and 0.96 Gy for non-IGRT). The volume that received less than 1 Gy per fraction decreased (mean difference to PCT, 1.36 cm{sup 3} for IGRT [p = 0.003] and 1.35 cm{sup 3} for non-IGRT [p = 0.003]) and the volume that received more than 1.6 Gy per fraction increased with increasing fraction number (mean difference to PCT, 1.14 cm{sup 3} for IGRT [p = 0.01] and 1.16 cm{sup 3} for non-IGRT [p = 0.006]). There was no statistically significant difference between the two scenarios (CMD, p = 0.095; volume that received <1 Gy per fraction, p = 0.896; and volume that received >1.6 Gy per fraction, p = 0.855). Conclusions: In the analyzed group the actual delivered dose to the PGs does not differ significantly between an IGRT and a non-IGRT approach. However, IGRT in head-and-neck cancer intensity-modulated radiotherapy is strongly recommended to improve patient setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of copper-rich regions on tensile properties of VPPA weldments of 2219-T87 aluminum

This study examines the relations between tensile properties and microstructural features of variable polarity plasma arc (VPPA) weldments of 2219-T87 aluminum. Crack initiation and weld failure of transverse tensile specimens of single and multipass weldments were studied. The specimens fractured on the rising portion of the stress-strain curve prior to necking, signifying that an increase in strength would accompany an increase in ductility. Of particular interest is a shallow, typically 0.001-0.003-in. (0.03-0.08-mm) deep, copper-rich region located in the crown and root corners of the weld. This region is a primary source of crack initiation and growth, due to its brittle nature and highly strained location. The brittle regions were removed by electropolishing and machining to determine their effect on weld tensile properties. The removal increased the ductility of the weld specimens, and in the case of single pass welds, actually increased the load carrying capacity. Local strain measurements and metallographic and chemical analyses are presented.

Hartman, J. A.↗

SU-E-T-659: Quantitative Evaluation of Patient Setup Accuracy of Stereotactic Radiotherapy with the Frameless 6D-ExacTrac System Using Statistical Modeling

Purpose: To evaluate patient setup accuracy and quantify individual and cumulative positioning uncertainties associated with different hardware and software components of the stereotactic radiotherapy (SRS/SRT) with the frameless-6D-ExacTrac system. Methods: A statistical model was used to evaluate positioning uncertainties of the different components of SRS/SRT treatment with the BrainLAB 6D-ExacTrac system using the positioning shifts of 35 patients having cranial lesions (49 total lesions treated in 1, 3, 5 fractions). All these patients were immobilized with rigid head-and-neck masks, simulated with BrainLAB-localizer and planned with iPlan treatment planning system. Infrared imaging (IR) was used initially to setup patients. Then, stereoscopic x-ray images (XC) were acquired and registered to corresponding digitally-reconstructed-radiographs using bony-anatomy matching to calculate 6D-translational and rotational shifts. When the shifts were within tolerance (0.7mm and 1°), treatment was initiated. Otherwise corrections were applied and additional x-rays were acquired (XV) to verify that patient position was within tolerance. Results: The uncertainties from the mask, localizer, IR-frame, x-ray imaging, MV and kV isocentricity were quantified individually. Mask uncertainty (Translational: Lateral, Longitudinal, Vertical; Rotational: Pitch, Roll, Yaw) was the largest and varied with patients in the range (−1.05−1.50mm, −5.06–3.57mm, −5.51−3.49mm; −1.40−2.40°, −1.24−1.74°, and −2.43−1.90°) obtained from mean of XC shifts for each patient. Setup uncertainty in IR positioning (0.88,2.12,1.40mm, and 0.64,0.83,0.96°) was extracted from standard-deviation of XC. Systematic uncertainties of the localizer (−0.03,−0.01,0.03mm, and −0.03,0.00,−0.01°) and frame (0.18,0.25,−1.27mm,−0.32,0.18, and 0.47°) were extracted from means of all XV setups and mean of all XC distributions, respectively. Uncertainties in isocentricity of the MV radiotherapy machine were (0.27,0.24,0.34mm) and kV-imager (0.15,−0.4,0.21mm). Conclusion: A statistical model was developed to evaluate the individual and cumulative systematic and random uncertainties induced by the different hardware and software components of the 6D-ExacTrac-system. The immobilization mask was associated with the largest positioning uncertainty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tobacco Smoking During Radiation Therapy for Head-and-Neck Cancer Is Associated With Unfavorable Outcome

Purpose: To evaluate the effect of continued cigarette smoking among patients undergoing radiation therapy for head-and-neck cancer by comparing the clinical outcomes among active smokers and quitters. Methods and Materials: A review of medical records identified 101 patients with newly diagnosed squamous cell carcinoma of the head and neck who continued to smoke during radiation therapy. Each active smoker was matched to a control patient who had quit smoking before initiation of radiation therapy. Matching was based on tobacco history (pack-years), primary site, age, sex, Karnofsky Performance Status, disease stage, radiation dose, chemotherapy use, year of treatment, and whether surgical resection was performed. Outcomes were compared by use of Kaplan-Meier analysis. Normal tissue effects were graded according to the Radiation Therapy Oncology Group/European Organization for the Treatment of Cancer toxicity criteria. Results: With a median follow-up of 49 months, active smokers had significantly inferior 5-year overall survival (23% vs. 55%), locoregional control (58% vs. 69%), and disease-free survival (42% vs. 65%) compared with the former smokers who had quit before radiation therapy (p < 0.05 for all). These differences remained statistically significant when patients treated by postoperative or definitive radiation therapy were analyzed separately. The incidence of Grade 3 or greater late complications was also significantly increased among active smokers compared with former smokers (49% vs. 31%, p = 0.01). Conclusions: Tobacco smoking during radiation therapy for head-and-neck cancer is associated with unfavorable outcomes. Further studies analyzing the biologic and molecular reasons underlying these differences are planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-Driven Approach to Generating Achievable Dose-Volume Histogram Objectives in Intensity-Modulated Radiotherapy Planning

Purpose: To propose a method of intensity-modulated radiotherapy (IMRT) planning that generates achievable dose-volume histogram (DVH) objectives using a database containing geometric and dosimetric information of previous patients. Methods and Materials: The overlap volume histogram (OVH) is used to compare the spatial relationships between the organs at risk and targets of a new patient with those of previous patients in a database. From the OVH analysis, the DVH objectives of the new patient were generated from the database and used as the initial planning goals. In a retrospective OVH-assisted planning demonstration, 15 patients were randomly selected from a database containing clinical plans (CPs) of 91 previous head-and-neck patients treated by a three-level IMRT-simultaneous integrated boost technique. OVH-assisted plans (OPs) were planned in a leave-one-out manner by a planner who had no knowledge of CPs. Thus, DVH objectives of an OP were generated from a subdatabase containing the information of the other 90 patients. Those DVH objectives were then used as the initial planning goals in IMRT optimization. Planning efficiency was evaluated by the number of clicks of the 'Start Optimization' button in the course of planning. Although the Pinnacle{sup 3} treatment planning system allows planners to interactively adjust the DVH parameters during optimization, planners in our institution have never used this function in planning. Results: The average clicks required for completing the CP and OP was 27.6 and 1.9, respectively (p <.00001); three OPs were finished within a single click. Ten more patient's cord + 4 mm reached the sparing goal D{sub 0.1cc} <44 Gy (p <.0001), where D{sub 0.1cc} represents the dose corresponding to 0.1 cc. For planning target volume uniformity, conformity, and other organ at risk sparing, the OPs were at least comparable with the CPs. Additionally, the averages of D{sub 0.1cc} to the cord + 4 mm decreased by 6.9 Gy (p <.0001); averages of D{sub 0.1cc} to the brainstem decreased by 7.7 Gy (p <.005). The averages of V(30 Gy) to the contralateral parotid decreased by 8.7% (p <.0001), where V(30 Gy) represents the percentage volume corresponding to 30 Gy. Conclusion: The method heralds the possibility of automated IMRT planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗