Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Neutron detection using a crystal ball calorimeter

The program of experiments of the A2 Collaboration performed on a beam of tagged photons of the MAMI electron microtron in Mainz (Germany) includes precision measurements of the total and differential cross sections of the pion photoproduction on neutrons of a deuterium target. The determination of the detector ability to detect neutrons is undoubtedly one of the important problems of the experiment. The calorimetric system of the detector contains a segmented NaI Crystal Ball detector, which gives information about the position, energy, and detection time of neutral and charged particles in a wide angular range. In this work, we describe the measurement of the neutron detection efficiency in the energy range from 20 to 400MeV. The results are compared with BNL data obtained on a pion beam and proton target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertically Self-Oriented, Ultrafast 1D ZnO:Li Nanorods as Scintillators for Thermal Neutron Detection

Detection of special nuclear materials (SNMs) is of vital importance in the prevention of nuclear terrorism and to secure states’ national security. Neutron detection is a particularly useful tool to identify SNM, and neutron-sensitive scintillators have many promising properties, such as ease of use, good time resolution, and high detection efficiency. In this work, we develop highly stable, self-oriented, ultrafast 1D ZnO:Li (and codoped with Al, Ga, and In) nanorods (NRs) as thermal neutron-sensitive scintillators. Lithium-6 has high thermal neutron cross section for the (n, α) reaction in ZnO:Li scintillators which have a vertical nano array design greatly increasing the effective surface area and scintillation efficiency. Cost-effective low-temperature (95 °C) hydrothermal growth is used to obtain highly crystalline ZnO:Li nano scintillators by combining nuclear range data and electron transport mechanisms. Among the studies using low-temperature hydrothermal synthesis and a relatively low annealing temperature (≈350 °C) along with optimized NRs (length ≈ 5–8 μm, mean diameter ≈ 700 nm) for thermal neutron detection, this study reports the shortest scintillation decay time (≈ 470 ps) so far to the best of our knowledge. In conclusion, this nano array scintillator combines the advantages of a low-cost growth technique with environmentally friendly and widely available materials.

Ions↗

Final Technical Report for the Neutron Detection without Helium-3 Project

This report details the results of the research and development work accomplished for the ‘Neutron Detection without Helium-3’ project conducted during the 2011-2013 fiscal years. The primary focus of the project was to investigate commercially available technologies that might be used in safeguards applications in the relatively near term. Other technologies that are being developed may be more applicable in the future, but were outside the scope of this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detection efficiency measurements of organic glass scintillator arrays

We characterize the neutron detection efficiency of pixelated organic glass scintillator (OGS) arrays manufactured in two ways: an additive method in which the OGS is cast in place in a pixelated mold, and a subtractive method in which the scintillator is first cast as a large block before being cut in bars and bonded together to form the array. The cast-in-place array utilizes a mixture of “bis(9,9-dimethyl-9H-fluoren-2-yl)diphenylsilane” (P2), “tri([1,1'-biphenyl]-4-yl)(phenyl)silane” (PB3), and “4-bis(2-methylstyryl)benzene” (MSB), and 50% by weight of polystyrene is added to the mixture for subtractive manufactured array. We compare the performance of the OGS arrays to that of an EJ-299-33M plastic scintillator array that was manufactured using a subtractive process similar to that of the second OGS array.

Neutron detectors (cold, thermal, fast neutrons)↗

Computational investigation of arranged scintillating particle composites for fast neutron detection

Composite materials have the potential to play an important role in enabling high-performance and cost-effective neutron detectors for fundamental science, global security, and dosimetry applications. This work presents neutron and gamma transport simulation results on composites consisting of 6 Li-containing GS20 scintillator glass particles arranged in an organic matrix. These composites achieve high sensitivity for neutrons while suppressing signals from gamma rays. The simulations successfully identified optimal composite parameters such as particle size, geometry, and inter-particle pitch. This information is key to the subsequent fabrication and scale-up of the desired GS20-in-acrylic composite. Finally, the simulation results presented in this paper demonstrate that arranged composites can provide high neutron detection efficiency with gamma misidentification values of <1 in 10 6 gamma rays, assuming irradiation with a 252 Cf spontaneous fission source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stoichiometric Effects on the Photoelectric Properties of LiInSe 2 Crystals for Neutron Detection

6 LiInSe 2 is a promising semiconductor candidate for thermal neutron detection due to its large capture cross-section. However, the charge collection efficiency is still insufficient for high resolution for the grown-in defects induced by the stoichiometric deviation. In this work, we report photoelectric properties of stoichiometric LiInSe 2 crystal boules up to 70 mm in length and 20 mm in diameter grown by the vertical Bridgman method. Inductively coupled plasma measurements demonstrate that the ratio of Li, In, and Se of the as-grown crystal is very close to 1:1:2, which is optimized by low temperature synthesis processing. The obtained single crystals display high bulk resistivity in the range of 10 11 –10 12 Ω·cm and a direct band gap of 2.01–2.83 eV with a changeable color from red to yellow. The electronic structure of LiInSe 2 was studied using first-principles density functional theory calculations, which predicts that the antisite defects of In Li and Li In are the dominant factor for the different crystal colors observed. The stoichiometric LiInSe 2 crystal gives an improved energy resolution, for a semiconductor detector when illuminated with a 241 Am@5.48 MeV α source, of 23.3%. In conclusion, the electron mobility-lifetime product (μτ) is ~2.5 × 10 –5 cm 2 V –1 .

36 MATERIALS SCIENCE↗

High efficiency method of fast neutron detection by oxide scintillators for detection systems of fissionable radioactive substances

Comparative measurements and analysis of detection efficiency (DE) of fast neutrons from {sup 239}Pu-Be source have been carried out in a broad energy range En {approx} 0.1 ./. 10 MeV using oxide scintillators BGO, GSO, CWO, ZnWO, ZnSe(Te, O), as well as LiI(Eu). DE of fast neutrons by heavy oxide scintillators was found to be very high ({approx} 40-50 %). The neutron inelastic scattering reaction (n, n'y) is considered as the most probable interaction mechanism of neutrons with nuclei of heavy oxide scintillators. It is concluded that heavy oxide scintillators, which are at the same time efficient gamma-detectors, allow creation of a highly efficient gamma-neutron detector ensuring high detection efficiency of fissionable radioactive substances. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Detection and Nuclear Security Summer School - Activity 3A: Pulse Shape Discrimination and Fast Neutron Detection

THE NEUTRON SOURCE: The source of neutrons used will be a 252 Cf source that contains about 1/3 of a microgram. 97% of decays are alpha decays while about 3% are spontaneous fission events emitted with an approximate Maxwellian/Watt spectrum. These neutrons are formed with a spread of kinetic energies ranging up to about 10 MeV (see lecture notes).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission meter and neutron detection using poisson distribution comparison

A neutron detector system and method for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. Comparison of the observed neutron count distribution with a Poisson distribution is performed to distinguish fissile material from non-fissile material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission meter and neutron detection using poisson distribution comparison

A neutron detector system and method for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. Comparison of the observed neutron count distribution with a Poisson distribution is performed to distinguish fissile material from non-fissile material.

Rowland, Mark S.↗

Determining plutonium mass in spent fuel using Cf-252 interrogation with prompt neutron detection

{sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection is proposed as one of 14 NDA techniques to determine Pu mass in spent fuel assemblies (FAs). CIPN is a low-cost and portable instrument, and it looks like a modified fork detector combined with an active interrogation source. Fission chamber (FC) is chosen as neutron detector because of its insensitivity to {gamma} radiation. The CIPN assay is comprised of two measurements, a background count and an active count, without and with the {sup 252}Cf source next to the fuel respectively. The net signal above background is primarily due to the multiplication of Cf source neutrons caused by the fissile content. The capability of CIPN to detect diversion and to determine fissile content was quantified using MCNPX simulations. New schemes were proposed (such as burnup and cooling time correction, etc.) and the results show that the fissile content of a target spent fuel assembly can be determined using CIPN signal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

{sup 6}LiF oleic acid capped nanoparticles entrapment in siloxanes for thermal neutron detection

The good light output of siloxane based scintillators as displayed under γ-rays and α particles has been exploited here to obtain clear and reliable response toward thermal neutrons. Sensitization towards thermal neutrons has been pursued by adding {sup 6}LiF, in form of nanoparticles. Aiming at the enhancement of compatibility between the inorganic nanoparticles and the low polarity, siloxane based surrounding medium, oleic acid-capped {sup 6}LiF nanoparticles have been synthesized by thermal decomposition of Li trifluoroacetate. Thin pellets siloxane scintillator maintained their optical transmittance up to weight load of 2% of {sup 6}Li. Thin samples with increasing {sup 6}Li concentration and thicker ones with fixed {sup 6}Li amount have been prepared and tested with several sources (α, γ-rays, moderated neutrons). Light output as high as 80% of EJ212 under α irradiation was measured with thin samples, and negligible changes have been observed as a result of {sup 6}LiF addition. In case of thick samples, severe light loss has been observed, as induced by opacity. Nevertheless, thermal neutrons detection has been assessed and the data have been compared with GS20, based on Li glass, taken as a reference material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Hydrogen Content Graphene Hydride Compounds & High Cross-­ Section Cladding Coatings for Fast Neutron Detection

The objective is to develop and implement a superior low-cost, large area (potentially >32in), easily deployable, close proximity, harsh environment innovative neutron sensor needed for next generation fuel cycle monitoring. We will exploit recent breakthroughs at the PI’s lab on the electrochemistry of epitaxial graphene (EG) formed on commercial SiC wafers, a transformative nanomaterial system with superior radiation detection and durability properties to develop a new paradigm in detection for fast neutrons, a by-product of fission reactors. There are currently few effective detection/monitoring schemes, especially solid-state ones at present. This is essential for monitoring and control of future fuel cycles to make them more efficient and reliable. By exploiting these novel materials, as well as innovative hybrid SiC/EG/Cladding device architectures conceived by the team, will develop low-cost, high performance solutions to fast-neutron detection. Finally, we will also explore 3-terminal device implementations for neutron detectors with built-in electronic gain to further shrink these devices and improve their sensitivity.

36 MATERIALS SCIENCE↗

Neutron detection with single crystal organic scintillators

Detection of high-energy neutrons in the presence of gamma radiation background utilizes pulse-shape discrimination (PSD) phenomena in organics studied previously only with limited number of materials, mostly liquid scintillators and single crystal stilbene. The current paper presents the results obtained with broader varieties of luminescent organic single crystals. The studies involve experimental tools of crystal growth and material characterization in combination with the advanced computer modeling, with the final goal of better understanding the relevance between the nature of the organic materials and their PSD properties. Special consideration is given to the factors that may diminish or even completely obscure the PSD properties in scintillating crystals. Among such factors are molecular and crystallographic structures that determine exchange coupling and exciton mobility in organic materials and the impurity effect discussed on the examples of trans-stilbene, bibenzyl, 9,10-diphenylanthracene and diphenylacetylene.

36 MATERIALS SCIENCE↗

Modeling and Simulation Optimization and Feasibility Studies for the Neutron Detection without Helium-3 Project

This report details the results of the modeling and simulation work accomplished for the ‘Neutron Detection without Helium-3’ project during the 2011 and 2012 fiscal years. The primary focus of the project is to investigate commercially available technologies that might be used in safeguards applications in the relatively near term. Other technologies that are being developed may be more applicable in the future, but are outside the scope of this study.

Ely, James H.↗

Binderless composite scintillator for neutron detection

Composite scintillator material consisting of a binderless sintered mixture of a Lithium (Li) compound containing .sup.6Li as the neutron converter and Y.sub.2SiO.sub.5:Ce as the scintillation phosphor, and the use of this material as a method for neutron detection. Other embodiments of the invention include various other Li compounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Detection Evaluation

These slides present a summary of previous work, conclusions, and anticipated schedule for the conclusion of our fast neutron detection evaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗