Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Dosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Characterization Summary: NETL Beam Port 1/5 Free-Field Environment at the 128-inch Core Centerline Adjacent (NETL-FF-BP1/5-128-cca)

This document presents the facility-recommended characterization of the neutron, prompt gamma ray, and delayed gamma ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port 1/5 free-field environment at the 128-inch location adjacent to the core centerline. The designation for this environment is NETL-FF-BP1/5-128-cca. The neutron, prompt gamma ray, and delayed gamma ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma ray fluence profiles within the experiment area of the cavity. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IDAC-Bio, A Software for Internal Dosimetry Based on the New ICRP Biokinetic Models and Specific Absorbed Fractions

Radiation dosimetry is central to virtually all radiation safety applications, optimization, and research. It relates to various individuals and population groups and to miscellaneous exposure situations—including planned, existing, and emergency situations. The International Commission on Radiological Protection (ICRP) has developed a new computational framework for internal dose estimations. Important components are more detailed and improved anatomical models and more realistic biokinetic models than before. The ICRP is currently producing new organ dose and effective dose coefficients for occupational intakes of radionuclides (OIR) and environmental intakes of radionuclides (EIR), which supersede the earlier dose coefficients in Publication 68 and the Publication 72 series, respectively. However, the ICRP only publishes dose coefficients for a single acute intake of a radionuclide and for an integration period of 50 years for intake by adults and to age 70 years for intakes by pre-adults. The new software, IDAC-Bio, performs committed absorbed dose and effective dose calculations for a selectable intake scenario, e.g., for a continuous intake or an intake during x hours per day and y days per week, and for any selected integration time. The software uses the primary data and models of the ICRP biokinetic models and numerically solves the biokinetic model and calculates the absorbed doses to organs and tissues in the ICRP reference human phantoms. The software calculates absorbed dose using the nuclear decay data in ICRP publication 107. IDAC-Bio is a further development and an important addition to the internal dosimetry program IDAC-Dose2.1. Here, the results generated by the software were validated against published ICRP dose coefficients. The potential of the software is illustrated by dose calculations for a nuclear power plant worker who had been exposed to varying levels of 60 Co and who had undergone repeated whole-body measurements, and for a hypothetical member of the public subject to future releases of 148 Gd from neutron spallation in tungsten at the European Spallation Source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Characterization Summary: Godiva IV Critical Assembly Environments at the In-Core, Top Hat, 1m, and 2m Irradiation Locations

This document presents the facility-recommended characterization of the neutron, prompt gamma ray, and delayed gamma ray radiation fields at the Godiva IV critical assembly at the National Criticality Experiments Research Center (NCERC). The environments assessed include the In-Core location, a location on the Top Hat, 1m away from the assembly, and 2m away from the assembly. The neutron, prompt gamma ray, and delayed gamma ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma ray fluence profiles on the Top Hat surrounding the critical assembly. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of As-read and As-run Dosimetry Data

The Nuclear Science Users Facilities (NSUF) is responsible for the coordination of experiments conducted in Advanced Test Reactor (ATR) by Universities and other outside organizations. Completion of the experiment and data reporting process is long and expensive. As such, it is expected that targets for temperature and neutron dosage are met. Simulations of expected reactor performance under specific conditions to meet these targets are critical for this process. However, it is not often that these reports are correlated with the data produced by monitors in ATR. This project aims to correlate simulation and read data from experiments in ATR to gauge uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Re-evaluating the prompt fission neutron spectrum of spontaneously fissioning 252 Cf

The prompt fission neutron spectrum (PFNS) of spontaneously fissioning 252 Cf is a Neutron Data Standards observable. Nearly all fission spectra of actinides were measured relative to it, using efficiencies derived from it, or analyzed with simulations validated by it. The current Standards evaluation was published by W. Mannhart in 1987. It could not be updated because the evaluation input, experimental mean values and covariances, were lost. First, we attempt to reproduce it. However, Mannhart’s evaluation can only be reproduced within its one-σ uncertainties as some of its aspects (e.g., experimental covariances, rejected data points) remain unknown. Therefore, a new evaluation is presented: We revisit all existing experimental 252 Cf(sf) PFNS data, including those published after the release of the current Standards evaluation, and re-estimate associated covariances. The newly evaluated 252 Cf(sf) PFNS differs distinctly from Mannhart’s below 300 keV and extends it to lower and higher outgoing neutron energies (500 eV–25 MeV). The new evaluated uncertainties are larger from 3–9 MeV and smaller otherwise. Spectrum averaged cross sections of importance to the International Reactor Dosimetry and Fusion File community calculated with the new spectrum are close to those calculated with Mannhart’s evaluation and agree with experimental values well within their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Characterization Summary: WSMR Fast Burst Reactor Environment at the 6-Inch and 24-Inch Irradiation Locations

This document presents the facility-recommended characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G), at the 6-inch and the 24-inch irradiation locations. The neutron, prompt gamma-ray, and delayed gamma-ray energy spectra, uncertainties, and covariance matrices are presented. Code dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Early-Stage Radiation Safety Analysis for the Spallation Neutron Source Second Target Station Bunker Operations

The Second Target Station project at Oak Ridge National Laboratory will develop a cold neutron source to meet growing experimental needs. This paper describes calculations of the residual dose rates associated with the monolith shield plug and the beamline bunker, two key conventional operations and radiation safety features. While neutron production is active, the instrument hall outside the bunker must be generally accessible with dose rates of less than 0.25 mrem/h. When neutron production is halted, the bunker must be accessible for hands-on maintenance operations. Further, these two requirements form the cause for the assessments reported herein of residual dose rates caused by the monolith shield plug and residual dose rates in the bunker. The monolith shield plug was shown to not produce significant dose rates inside the bunker after a 20-year lifetime, and the residual dose rates inside the bunker for the case of an operating beamline were shown to reasonably allow for hands-on maintenance. These calculations are based on preliminary design models of the relevant systems. Additionally, an example showing the significance of considering neutron supermirror physics in transport calculations that track nuclide production and destruction rates to produce gamma sources for residual dose rate calculations is included. The example shows that if neutron supermirror physics is not considered, dose rate fields may be significantly underpredicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

NCERC-CL TREAT Free Field Characterization Foil Reaction Rate Results

This report summarizes the analysis and preliminary MCNP reaction rate modeling of free field characterization measurements performed in the Transient Reaction Test Facility (TREAT) at Idaho National Laboratory (INL) between 12/18/2023 and 2/22/2024. A series of seven irradiations were performed using the Big-BUSTER (Broad Use Specimen Transient Experiment Rig) core configuration. Foil sets including 19.5% LEU-Zr alloy wire, S, Au, Fe, Ni, Co, Ti, and Zr were deployed in each irradiation. Identical foil sets were supplied to Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and INL. All foils were supplied by INL. Additional details on the experiment can be found in [2]. The foil sets were shipped to the National Criticality Experiments Research Center Counting Laboratory (NCERC-CL) branch at LANL (NCERC-CL NISC) and were received on 3/25/2024. Additional details on receipt and counting are reported in [3]. All reactor dosimetry measurements were performed in adherence to the ASTM standards applicable to reactor dosimetry. Measured reaction rates from Au, Co, Fe, Ni, and Ti are reported. Select reaction rate ratios and simulated reaction rates and ratios are discussed. Reaction rates for all measured reaction products were modeled with MCNP 6.3.1 and a TREAT input deck supplied by Edward Lum. Neutron emission estimates calculated using the measured and simulated reaction rates show excellent agreement between the three fast-threshold n-p reactions with the percent differences being < 9% between the three reactions. The capture reactions had poorer, but still reasonable, agreement with < 20% percent differences between the neutron emission estimates of the three capture reactions. The percent difference between the fast-threshold and capture reactions is ∼ 100% for each reaction. This supports the TREAT model is not accurately modeling the neutron spectrum and additional measurements are required to characterize TREAT and match measurements to simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-484 CED3b Report: AFRRI ER1 Dosimetry Characterization

This report presents the preliminary work for IER 484, the characterization of the leakage radia tion field from the TRIGA reactor at the Armed Forces Radiobiology Research Institute (AFRRI). The purpose of the dose characterization is to establish the reference dose needed to execute a NAD inter-comparison exercise. During the week of August 20th, a team from Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratory (SNL), and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed various measurements in AFRRI’s TRIGA ER1 (Exposure Room 1) with Passive Neutron Spectrometer (PNS) spheres and nuclear accident dosimeters (NADs) mounted on Bottle Manikin Absorption (BOMAB) phantoms (to simulate doses received by people) and additional NADs mounted on aluminum plates (to simulate doses in free air). Without Atomic Weapons Establishment (AWE), LLNL became responsible for measuring the neutron spectrum using PNS spheres. SNL is responsible for providing photon dose data. LLNL, SNL, and IRSN each deployed their own NADs, which will be compared to the reference dose measured. Final characterization of the dose field based on analyzed data will be presented in the CED4a report.

42 ENGINEERING↗

SPND Sensitivity Calculations Using MCNP and Experimental Data from ACRR

The use of the Monte Carlo N-Particle Transport Code (MCNP) to calculate detector sensitivity for Self-Powered Neutron Detectors (SPNDs) in the Annular Core Research Reactor (ACRR) could be a vital tool in the effort to optimize the design of next-generation SPNDs. Next-generation SPND designs, which consider specific materials and geometry, may provide experimenters with capabilities for advanced mixed field dosimetry. These detectors will need to be optimized for configuration, materials, and geometries and the ability to model and iterate must be available in order to decide on the ideal. SPND design. SPNDs were modeled in MCNP which closely resembled the dimensions and location of actual detectors used in the ACRR. Tallies were used to calculate detector sensitivity. Using metrics from a previous report, oscilloscope data from pulses were manipulated in a Matrix Laboratory computing environment (MATLAB) script to calculate experimental detector sensitivity. This report outlines the process in which experimental data from ACRR pulses verified results from tallies in an MCNP ACRR model. The sensitivity values from experiments and MCNP calculations agreed within one standard deviation. Parametric studies were also performed with MCNP to investigate the effects of materials and dimensions of different SPNDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Basic Radiation Theory and Protection [Slides]

Topics for this presentation include isotopes, alpha and beta radiation, x-rays and gamma-rays, neutrons, ionizing radiation, occupational exposure to radiation (CFR limit), radiation exposure amounts, the half-life, radiation protection, inverse square law (1/r 2 ), fission, fusion, and criticality.

61 RADIATION PROTECTION AND DOSIMETRY↗