Thermal Gradient and Neutron Irradiation Experiment Design for Fusion Reactor Materials in the Advanced Test Reactor

This work outlines a hypothetical coupled thermal gradient and neutron irradiation experiment in the Advanced Test Reactor (ATR) at the Idaho National Laboratory. Although the ATR is a thermal spectrum test reactor and doesn’t inherently produce a flux spectrum dominated by the high-energy neutrons typical in a fusion reactor, it’s multitude of experiment positions and dynamic flux environment make it a suitable platform for investigating fusion related issues.

36 MATERIALS SCIENCE↗

Stoichiometric tuning of lattice flexibility and Na diffusion in NaAlSiO 4 : quasielastic neutron scattering experiment and ab initio molecular dynamics simulations

We have performed quasielastic neutron scattering (QENS) experiments up to 1243 K and ab initio molecular dynamics (AIMD) simulations to investigate the Na diffusion in various phases of NaAlSiO4 (NASO), namely, low-carnegieite (L-NASO; trigonal), high-carnegieite (H-NASO; cubic) and nepheline (N-NASO; hexagonal) phases. The QENS measurements reveal Na ions localized diffusion behavior in L-NASO and N-NASO, but long-range diffusion behavior in H-NASO. Furthermore, the AIMD simulation supplemented the QENS measurements and showed that excess Na ions in H-NASO enhance the host network flexibility and activate the AlO 4 /SiO 4 tetrahedra rotational modes. These framework modes enable the long-range diffusion of Na across a pathway of interstitial sites. The simulations also show Na diffusion in Na-deficient N-NASO through vacant Na sites along the hexagonal c-axis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complete Monte Carlo Simulation of Neutron Scattering Experiments

In the far past, it was not possible to accurately correct for the finite geometry and the finite sample size of a neutron scattering set-up. The limited calculation power of the ancient computers as well as the lack of powerful Monte Carlo codes and the limitation in the data base available then prevented a complete simulation of the actual experiment. Using e.g. the Monte Carlo neutron transport code MCNPX [1], neutron scattering experiments can be simulated almost completely with a high degree of precision using a modern PC, which has a computing power that is ten thousand times that of a super computer of the early 1970s. Thus, (better) corrections can also be obtained easily for previous published data provided that these experiments are sufficiently well documented. Better knowledge of reference data (e.g. atomic mass, relativistic correction, and monitor cross sections) further contributes to data improvement. Elastic neutron scattering experiments from liquid samples of the helium isotopes performed around 1970 at LANL happen to be very well documented. Considering that the cryogenic targets are expensive and complicated, it is certainly worthwhile to improve these data by correcting them using this comparatively straightforward method. As two thirds of all differential scattering cross section data of {sup 3}He(n,n){sup 3}He are connected to the LANL data, it became necessary to correct the dependent data measured in Karlsruhe, Germany, as well. A thorough simulation of both the LANL experiments and the Karlsruhe experiment is presented, starting from the neutron production, followed by the interaction in the air, the interaction with the cryostat structure, and finally the scattering medium itself. In addition, scattering from the hydrogen reference sample was simulated. For the LANL data, the multiple scattering corrections are smaller by a factor of five at least, making this work relevant. Even more important are the corrections to the Karlsruhe data due to the inclusion of the missing outgoing self-attenuation that amounts to up to 15%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron imaging experiments at E-12 beam-line of CIRUS

Neutron imaging beam-line at E-12 beam port of CIRUS reactor India has been developed to implement Neutron tomography, phase contrast imaging and dynamic imaging techniques for various applications. Several experiments on these techniques have been carried out successfully. Neutron radiography and tomography has been used to study blisters formation in pressure tube along with many other applications. Similarly phase contrast imaging has been used to study its feasibility for better contrast in radiographic images. Dynamic imaging has been applied to study the melting of pure and impure lead under heat. In this paper we report the details of various experiments performed at this beam-line.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lunar neutron probe experiment

Preliminary results of the Apollo 17 neutron probe are presented. The probe which was designed for measuring neutron capture rates to a depth of 2m in the lunar regolith is described, and the fission rates for U-235 are discussed. It is concluded that good agreement exists between the experimental results and theoretical calculations.

Woolum, D. S.↗

EXCALIBUR-at-CALIBAN: a neutron transmission experiment for {sup 238}U(n,n'{sub continuum}γ) nuclear data validation

Two recent papers justified a new experimental program to give a new basis for the validation of {sup 238}U nuclear data, namely neutron induced inelastic scattering and transport codes at neutron fission energies. The general idea is to perform a neutron transmission experiment through natural uranium material. As shown by Hans Bethe, neutron transmissions measured by dosimetric responses are linked to inelastic cross sections. This paper describes the principle and the results of such an experience called EXCALIBUR performed recently (January and October 2014) at the CALIBAN reactor facility. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 65 Cu(η, γ) cross section using the Detector for Advanced Neutron Capture Experiments at LANL

Improving our understanding of the origin of the elements in the observable universe as well as the nature of the environments responsible for their production has been of paramount importance to the nuclear physics community. More than half of the isotopes of these elements are created via neutron-capture processes, and thus accurate measurements of the salient underlying nuclear physics, such as neutron-capture cross sections, masses, and β-decay half-lives are crucial. Of particular signifcance to the synthesis of isotopes in the mass range of A ≈ 60 to A ≈ 90, via the weak s process, are the neutron-capture cross sections of 63,65 Cu, where large discrepancies between measurements exist. Recent measurements have addressed these discrepancies for 63 Cu [Weigand et al., Phys. Rev. C 95, 015808 (2017)], but questions still remain for 65 Cu. Here, we report a new measurement of the 65Cu(n, γ ) cross section performed using the Detector for Advanced Neutron Capture Experiments located at the Los Alamos Neutron Science Center of Los Alamos National Laboratory. The Maxwellian-averaged cross section (MACS) for 65 Cu(η, γ) at $kT$ = 30 keV deduced from this work is (37.0 ± 0.3 stat. ± 3.3 sys. ) mb. The impact on weak s-process nucleosynthesis of new MACS values, calculated over the range of kT = 5 to 100 keV, for 65 Cu, combined with the updated MACS for 63 Cu [Weigand et al., Phys. Rev. C 95, 015808 (2017)] and 63 Ni [Weigand et al., Phys. Rev. C 92, 045810 (2015)], were investigated. Findings of this investigation show an increase of predicted nucleosynthesis yields of elements of Zn to Zr by as much as 20%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A scalable transformer model for real-time decision making in neutron scattering experiments

The U.S. Department of Energy's (DOE's) neutron research facilities at Oak Ridge National Laboratory (ORNL), including the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS), are a state-of-the-art neutron scattering facility that allows researchers to study the structure and dynamics of materials at the atomic scale. At the SNS, neutrons are measured using the time-of-flight (TOF) technique as they move through a neutron beamline to interact with a sample. Large volumes of neutron scattering data are collected and recorded in neutron event mode. Optimal productivity of the TOF instrument is limited due to the lack of real-time data analysis tools. The large amount of data generated by the experiments can be challenging to process and analyze in real time, particularly for experiments that require rapid feedback and adjustment of experimental parameters. The regular computer/workstation cannot keep up with the experiment speed to provide real-time feedback to adjust experimental parameters, so connecting the supercomputers available to the neutron facility is necessary to achieve real-time data analysis and experiment steering. To address this challenge, we exploit the Frontier supercomputer at Oak Ridge Leadership Computing Facility (OLCF) to train a scalable temporal fusion transformer model for real-time decision making of TOF neutron scattering experimentation. Here, in this paper, we present the results using Frontier to provide the processing power needed to rapidly process and analyze large volumes of single-crystal diffraction data collected at TOPAZ, a neutron time-of-flight Laue single-crystal diffractometer at the SNS.

97 MATHEMATICS AND COMPUTING↗

Note: Versatile sample stick for neutron scattering experiments in high electric fields

We present a versatile high voltage sample stick that fits into all cryomagnets and standard cryostats at the Swiss Spallation Neutron Source, Paul Scherrer Institut, and which provides a low effort route to neutron scattering experiments that combine electric field with low temperature and magnetic field. The stick allows for voltages up to 5 kV and can be easily adapted for different scattering geometries. We discuss the design consideration and thermal behavior of the stick, and give one example to showcase the abilities of the device.

07 ISOTOPE AND RADIATION SOURCES↗

Preparation of a one-curie 171Tm target for the Detector for Advanced Neutron Capture Experiments (DANCE)

Roughly one curie of 171Tm (t1/2=1.92a) has been produced and purified for the purpose of making a nuclear target for the first measurements of its neutron capture cross section. Target preparation consisted of three key steps: (1) material production; (2) separation and purification; and (3) electrodeposition onto a suitable backing material. Approximately 1.5 mg of the target material (at the time of separation) was produced by irradiating roughly 250 mg of its stable enriched 170Er lanthanide neighbor with neutrons at the ILL reactor in France. This production method resulted in a “difficult-to-separate” 1:167 mixture of near-neighboring lanthanides, Tm and Er. Separation and purification was accomplished using high-performance liquid chromatorgraphy (HPLC), with a proprietary cation exchange column (Dionex, CS-3) and alpha-hydroxyisobutyric acid (a-HIB) eluent. This technique yielded a final product of ~95% purity with respect to Tm. A portion (20 ug) of the Tm was electrodeposited on thin Be foil and delivered to the Los Alamos Neutron Science CEnter (LANSCE) for preliminary analysis of its neutron capture cross section using the Detector for Advanced Neutron Capture Experiments (DANCE). This paper discusses the major hurdles associated with the separation and purification step including, scale-up issues related to the use of HPLC for material separation and purification of the target material from a-HIB and 4-(2-pyridylazo)resorcinol (PAR) colorant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Short-range order of undercooled melts of PdZr 2 intermetallic compound studied by X-ray and neutron scattering experiments

The short-range order in undercooled melts of the intermetallic Zr2Pd glass-forming alloy is investigated by combining electrostatic levitation (ESL) with high-energy X-ray diffraction and neutron diffraction. Experimentally determined structure factors are measured and analyzed with respect to various structures of short-range order. The comparative X-ray and neutron scattering experiments allow for investigations of topological and chemical short-range order. Based on these studies, no preference of a specific short-range order is found for the liquid Zr2Pd glass-forming alloy, even in the metastable state of the deeply undercooled melt. This is in agreement with an earlier report from X-ray diffraction and molecular-dynamics studies of a Zr75.5Pd24.5 liquid, which showed a broad distribution of cluster types. The results for the Zr2Pd liquid are discussed with respect to the glass-forming ability of this melt.

36 MATERIALS SCIENCE↗

Sensitivity Reach of the Neutron EDM Experiment: The Electric Field Strength

The search for an electric dipole moment of the neutron tests physics beyond the Standard Model such as new sources of CP-violation and Supersymmetry. The nEDM experiment aims to improve the sensitivity on the current limit of the electric dipole moment of the neutron to <10{sup -27} e{center_dot}cm. The experiment will use a flux of Ultra Cold Neutrons (UCNs) produced and stored in a bath of superfluid He-II. A change in precession frequency is expected for a non-zero EDM when an electric field is applied parallel and antiparallel to a magnetic field across the neutron storage cell. A dominant parameter in terms of reducing the statistical uncertainty of this measurement is the strength of the applied electric field. An experiment to measure if superfluid He-II can sustain up to 50 kV/cm for a volume and electrode spacings comparable to the nEDM experiment has been constructed at Los Alamos National Laboratory. It consists in a large-area parallel plate capacitor immersed in a 200 liter central volume inside a suitable cryostat that in turn is connected to a dilution refrigerator unit. A description of test runs and the status of the experiment is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ice I h revisited: No proton tunneling observed in a quasielastic neutron scattering experiment

A large broadening (${\sim}0.4\mathrm{meV}$) of quasielastic neutron scattering (QENS) signal in ${\mathrm{H}}_{2}\mathrm{O}$ ice ${I}_{h}$ at $T=5\mathrm{K}$ was observed by Bove et al. [Phys. Rev. Lett. 103, 165901 (2009)] and explained by a model of concerted proton tunneling. This result was rather unexpected, as prior studies never showed significant mobility in water at low temperatures and ambient pressure. There were a few attempts of theoretical understanding of the effect. Recent path-integral simulations as well as quantum lattice-gauge theory supported the possibility of the collective tunneling of protons in ice ${I}_{h}$, however other studies stated that concerted tunneling in ice ${I}_{h}$ should have very low frequency. In this paper, we report on QENS measurements of ${\mathrm{H}}_{2}\mathrm{O}$ ice ${I}_{h}$ at 1.8 and 5 K by using neutron scattering spectrometers with the energy resolution similar to and four times better than the energy resolution in the original experiment of Bove and co-workers. We did not observe any QENS broadening, and the measured spectra for the ice ${I}_{h}$ and the reference vanadium sample were almost identical. Therefore, we conclude that there is no proton tunneling in ice ${I}_{h}$ at temperatures down to 1.8 K measurable on an energy scale of 3.5 ${\mu}\mathrm{eV}$ and above. Finally, the literature data on low-temperature heat capacity of ice ${I}_{h}$ support this conclusion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient data reduction for time-of-flight neutron scattering experiments on single crystals

Event-mode data collection presents remarkable new opportunities for time-of-flight neutron scattering studies of collective excitations, diffuse scattering from short-range atomic and magnetic structures, and neutron crystallography. In these experiments, large volumes of the reciprocal space are surveyed, often using different wavelengths and counting times. These data then have to be added together, with accurate propagation of the counting errors. This paper presents a statistically correct way of adding and histogramming the data for single-crystal time-of-flight neutron scattering measurements. In order to gain a broader community acceptance, particular attention is given to improving the efficiency of calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Skylab neutron environment experiment (Science Demonstration SD-34 (TV108)). Description and preliminary results

Neutron and proton induced radioactivity at various locations within Skylab were measured. Samples of five metals were formed into activation packets and deployed at the following locations on the Skylab 4 mission: orbital workshop film vault, water storage tank, and two opposing orbital workshop internal locations. Radioactive nuclides were produced in the packets by nuclear interactions of high-energy protons and secondary neutrons within Skylab. Low-level gamma ray spectroscopy measurements were made on the returned packets to determine the incident neutron and proton fluxes and spectra and their variations with mass distribution.

Fishman, G. J.↗

Six-axis multi-anvil press for high-pressure, high-temperature neutron diffraction experiments

We developed a six-axis multi-anvil press, ATSUHIME, for high-pressure and high-temperature in situ time-of-flight neutron powder diffraction experiments. The press has six orthogonally oriented hydraulic rams that operate individually to compress a cubic sample assembly. Experiments indicate that the press can generate pressures up to 9.3 GPa and temperatures up to 2000 K using a 6-6-type cell assembly, with available sample volume of about 50 mm{sup 3}. Using a 6-8-type cell assembly, the available conditions expand to 16 GPa and 1273 K. Because the six-axis press has no guide blocks, there is sufficient space around the sample to use the aperture for diffraction and place an incident slit, radial collimators, and a neutron imaging camera close to the sample. Combination of the six-axis press and the collimation devices realized high-quality diffraction pattern with no contamination from the heater or the sample container surrounding the sample. This press constitutes a new tool for using neutron diffraction to study the structures of crystals and liquids under high pressures and temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗