Idaho Explosive Detection System

Learn how INL researchers are making the world safer by developing an explosives detection system that can inspect cargo. For more information about INL security research, visit http://www.facebook.com/idahonationallaboratory

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

Active Interrogation for Spent Fuel

The DDA instrument for nuclear safeguards is a fast, non-destructive assay, active neutron interrogation technique using an external 14 MeV DT neutron generator for characterization and verification of spent nuclear fuel assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stilbene Scintillator Detector Array and Data-Acquisition System for Active Interrogation

A large area Stilbene crystal detector array has been assembled and calibrated for use in active interrogation measurements. The array consists of 10 high-efficiency 4”x2” stilbene cells. The cells were grown by Inrad Optics using LLNL developed technology. The array can be used to detect multiple signatures of SNM items, both actively and passively. Prompt and delayed gamma rays as well as prompt and delay neutrons can be detected and counted separately. The array is coupled to the Mesytec MDPP-16 VME-based digitizer module for data acquisition. This module performs on-board pulse-shape discrimination of signals from the Stilbene crystal detectors. This data-acquisition module allows separation of neutron and gamma-ray events with a low demand on data transfer rates. In addition, the high-resolution timing (<100 ps) is suitable for correlated gamma-ray and neutron multiplicity counting. This report describes the construction and calibration of the system. We also discuss applications of the system as well as how the system is currently being utilized by end users.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Multi-particle inspection using associated particle sources

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing combined neutron and gamma ray radiography. For example, one exemplary system comprises: a neutron source; a set of alpha particle detectors configured to detect alpha particles associated with neutrons generated by the neutron source; neutron detectors positioned to detect at least some of the neutrons generated by the neutron source; a gamma ray source; a set of verification gamma ray detectors configured to detect verification gamma rays associated with gamma rays generated by the gamma ray source; a set of gamma ray detectors configured to detect gamma rays generated by the gamma ray source; and an interrogation region located between the neutron source, the gamma ray source, the neutron detectors, and the gamma ray detectors.

42 ENGINEERING↗

Time-Spectral Analysis Methods for Spent Fuel Assay Using Lead Slowing-Down Spectroscopy of Spent Fuel

Nondestructive techniques for measuring the mass of fissile isotopes in spent nuclear fuel is a considerable challenge in the safeguarding of nuclear fuel cycles. A nondestructive assay technology that could provide direct measurement of fissile mass, particularly for the plutonium (Pu) isotopes, and improve upon the uncertainty of today’s confirmatory methods is needed. Lead slowing-down spectroscopy (LSDS) has been studied for the spent fuel application previously, but the nonlinear effects of assembly self shielding (of the interrogating neutron population) have led to discouraging assay accuracy for realistic pressurized water reactor fuels. In this paper, we describe the development of time-spectral analysis algorithms for LSDS intended to overcome these self-shielding effects. The algorithm incorporates the tabulated energy-dependent cross sections from key fissile and absorbing isotopes, but leaves their mass as free variables. Multi-parameter regression analysis is then used to directly calculate not only the mass of fissile isotopes in the fuel assembly (e.g., Pu-239, U-235, and Pu-241), but also the mass of key absorbing isotopes such as Pu-240 and U-238. Modeling-based assay results using a first-order self-shielding relationship indicate that LSDS has the potential to directly measure fissile isotopes with less than 5% average relative error, over a wide fuel burnup range. Shortcomings in the first-order self-shielding model and methods to improve the formulation are described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combined Assay Systems for the Characterisation of Historical ILW at of the Dounreay Shaft and Silo-18140

In 1955 the Dounreay nuclear power development establishment was created on the northern coast of Scotland primarily to pursue the UK Government policy of developing Fast Breeder Reactor (FBR) technology. The site operated then by the United Kingdom Atomic Energy Authority (UKAEA) saw the development, test and operation of 3 nuclear reactors, two of them FBRs, alongside fabrication and reprocessing facilities for the FBR fuel elements. From the late 1950's until 1977 Intermediate Level radioactive Waste (ILW) generated on site was disposed of into a 65 m deep, 4.6 m diameter shaft. In January 1977, an explosion thought to be caused by hydrogen generated from sodium and potassium wastes reacting with water occurred in the upper part of the shaft, thus stopping any further waste disposal. A second ILW storage facility, the ILW-Silo, started operation in 1971 to deal with the increasing volume of intermediate level waste generated on site in the mid-1960's and continued receiving waste until 1998. The decommissioning of the Shaft and Silo facilities is a challenging engineering task due to the complexity and potential hazards linked with the retrieval and handling of historical waste. Following recovery it is intended to shred the majority of the waste and load it into 200-l assay drums. Sludges would be separated and solidified within a special annulus drum to make them suitable for assay. To support the decommissioning strategies put forward by Dounreay Site Restoration Limited (DSRL), Mirion Technologies Canberra UK Ltd have designed and completed the manufacture of a pair of combined non-destructive waste assay (NDA) systems. The two identical automated ILW counters are intended to provide a means to characterise the waste materials by performing active and passive neutron measurement as well as segmented high resolution gamma spectrometry (HRGS) of 200-l sacrificial waste drums. The active neutron technique is based on the Differential Die Away (DDA) technique using a pulsed Deuterium-Tritium neutron generator to interrogate fissile material present in the waste. The active neutron measurements support, as well as the passive neutron coincidence measurements, a matrix correction capability by use of an Add-a-Source mechanism. The publication will describe in broad lines the approach proposed by DSRL in the processing of the waste retrieved from both the Shaft and Silo facilities. It will also present a description of the overall design of the NDA counters, illustrating how the measurements to be performed will allow DSRL to safely characterise the retrieved waste materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of combined delayed neutron and differential die-away prompt neutron signal detection for characterization of spent nuclear fuel assemblies

The Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy (DOE) has funded multiple laboratories and universities to develop a means to accurately quantify the Plutonium (Pu) mass in spent nuclear fuel assemblies and ways to also detect potential diversion of fuel pins. Delayed Neutron (DN) counting provides a signature somewhat more sensitive to {sup 235}U than Pu while Differential Die-Away (DDA) is complementary in that it has greater sensitivity to Pu. The two methods can, with care, be combined into a single instrument which also provides passive neutron information. Individually the techniques cannot robustly quantify the Pu content but coupled together the information content in the signatures enables Pu quantification separate to the total fissile content. The challenge of merging DN and DDA, prompt neutron (PN) signal, capabilities in the same design is the focus of this paper. Other possibilities also suggest themselves, such as a direct measurement of the reactivity (multiplication) by either the boost in signal obtained during the active interrogation itself or by the extension of the die-away profile. In an early study, conceptual designs have been modeled using a neutron detector comprising fission chambers or 3He proportional counters and a {approx}14 MeV neutron Deuterium-Tritium (DT) generator as the interrogation source. Modeling was performed using the radiation transport code Monte Carlo N-Particles eXtended (MCNPX). Building on this foundation, the present paper quantifies the capability of a new design using an array of {sup 3}He detectors together with fission chambers to optimize both DN and PN detections and active characterization, respectively. This new design was created in order to minimize fission in {sup 238}U (a nuisance DN emitter), to use a realistic neutron generator, to reduce the cost and to achieve near spatial interrogation and detection of the DN and PN, important for detection of diversion, all within the constraints of a single practical instrument. Both DN and PN detections are active techniques using the signal from the most prominent fissile isotopes of spent nuclear fuel that respond the best to a slow neutron interrogation, {sup 235}U, {sup 239}U and {sup 241}PU. The performance is characterized against a library of 64 assemblies and 40 diversion scenarios at different burnup (BU), cooling-time (CT) and initial enrichment (IE) in fresh water.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

Development of a Permanent-Magnet Microwave Ion Source for a Sealed-Tube Neutron Generator

A microwave ion source has been designed and constructed for use with a sealed-tube, high-yield neutron generator. When operated with a tritium-deuterium gas mixture the generator will be capable of producing 5*1011 n/s in non-proliferation applications. Microwave ion sources are well suited for such a device because they can produce high extracted beam currents with a high atomic fraction at low gas pressures of 0.2-0.3 Pa required for sealed tube operation. The magnetic field strength for achieving electron cyclotron resonance (ECR) condition, 87.5 mT at 2.45 GHz microwave frequency, was generated and shaped with permanent magnets surrounding the plasma chamber and a ferromagnetic plasma electrode. This approach resulted in a compact ion source that matches the neutron generator requirements. The needed proton-equivalent extracted beam current density of 40 mA/cm^2 was obtained at moderate microwave power levels of 400 W. Results on magnetic field design, pressure dependency and atomic fraction measured for different wall materials are presented.

43 PARTICLE ACCELERATORS↗

Determining plutonium mass in spent fuel with non-destructive assay techniques - NGSU research overview and update on 6 NDA techniques

This poster is one of two complementary posters. The Next Generation Safeguards Initiative (NGSI) of the U.S. DOE has initiated a multi-lab/university collaboration to quantify the plutonium (Pu) mass in, and detect the diversion of pins from, spent nuclear fuel assemblies with non-destructive assay (NDA). This research effort has the goal of quantifying the capability of 14 NDA techniques as well as training a future generation of safeguards practitioners. By November of 2010, we will be 1.5 years into the first phase (2.5 years) of work. This first phase involves primarily Monte Carlo modelling while the second phase (also 2.5 years) will focus on experimental work. The goal of phase one is to quantify the detection capability of the various techniques for the benefit of safeguard technology developers, regulators, and policy makers as well as to determine what integrated techniques merit experimental work, We are considering a wide range of possible technologies since our research horizon is longer term than the focus of most regulator bodies. The capability of all of the NDA techniques will be determined for a library of 64 17 x 17 PWR assemblies [burnups (15, 30, 45, 60 GWd/tU), initial enrichments (2, 3, 4, 5%) and cooling times (1, 5, 20, 80 years)]. The burnup and cooling time were simulated with each fuel pin being comprised of four radial regions. In this paper an overview of the purpose will be given as well as a technical update on the following 6 neutron techniques: {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Passive Neutron Albedo Reactivity, Self-Integration Neutron Resonance Densitometry. The technical update will quantify the anticipated performance of each technique for the 64 assemblies of the spent fuel library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Overview Of Activation Analysis Techniques And Applications

Activation analysis can be performed using three different techniques, namely: activation with neutrons, with high-energy photons, and with charged particles. The different features as well as the advantages and drawbacks of these separate techniques will be discussed in this paper. During exposure radionuclides are produced in the activated sample and, the turn, the radiation emitted during radioactive decay (photons in the most cases) is measured with appropriate spectrometers. By evaluating the produced spectra, the elemental components of the activated material can be quantitatively ascertained. Through means of activation analysis, basically any kind of material can be studied. And frequently the sample can be analysed as is(instrumentally without complicated radiochemical separation steps), and in favourable cases, the analysis may be conducted non-destructively, i.e. without removing pieces of the interrogated sample. Several common applications will be discussed in this paper.

07 ISOTOPE AND RADIATION SOURCES↗

Replacing a 252Cf source with a neutron generator in a shuffler - a conceptual design performed with MCNPX

The {sup 252}Cf shuffler has been widely used in nuclear safeguards and radioactive waste management to assay fissile isotopes, such as {sup 235}U or {sup 239}Pu, present in a variety of samples, ranging from small cans of uranium waste to metal samples weighing several kilograms. Like other non-destructive assay instruments, the shuffler uses an interrogating neutron source to induce fissions in the sample. Although shufflers with {sup 252}Cf sources have been reliably used for several decades, replacing this isotopic source with a neutron generator presents some distinct advantages. Neutron generators can be run in a continuous or pulsed mode, and may be turned off, eliminating the need for shielding and a shuffling mechanism in the shuffler. There is also essentially no dose to personnel during installation, and no reliance on the availability of {sup 252}Cf. Despite these advantages, the more energetic neutrons emitted from the neutron generator (141 MeV for D-T generators) present some challenges for certain material types. For example when the enrichment of a uranium sample is unknown, the fission of {sup 238}U is generally undesirable. Since measuring uranium is one of the main uses of a shuffler, reducing the delayed neutron contribution from {sup 238}U is desirable. Hence, the shuffler hardware must be modified to accommodate a moderator configuration near the source to tailor the interrogating spectrum in a manner which promotes sub-threshold fissions (below 1 MeV) but avoids the over-moderation of the interrogating neutrons so as to avoid self-shielding. In this study, where there are many material and geometry combinations, the Monte Carlo N-Particle eXtended (MCNPX) transport code was used to model, design, and optimize the moderator configuration within the shuffler geometry. The code is then used to evaluate and compare the assay performances of both the modified shuffler and the current {sup 252}Cf shuffler designs for different test samples. The matrix effect and the non-uniformity of the interrogating flux are investigated and quantified in each case. The modified geometry proposed by this study can serve s a guide in retrofitting shufflers that are already in use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

Spectrum tailoring of the neutron energy spectrum in the context of delayed neutron detection

For the purpose of measuring plutonium mass in spent fuel, a delayed neutron instrument is of particular interest since, if properly designed, the delayed neutron signal from {sup 235}U is significantly stronger than the signature from {sup 239}Pu or {sup 241}Pu. A key factor in properly designing a delayed neutron instrument is to minimize the fission of {sup 238}U. This minimization is achieved by keeping the interrogating neutron spectrum below {approx} 1 MeV. In the context of spent fuel measurements it is desirable to use a 14 MeV (deuterium and tritium) neutron generator for economic reasons. Spectrum tailoring is the term used to describe the inclusion of material between the 14 MeV neutrons and the interrogated object that lower the neutron energy through nuclear reactions and moderation. This report quantifies the utility of different material combination for spectrum tailoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeled Martian subsurface elemental composition measurements with the Probing In situ with Neutron and Gamma ray instrument: Gamma and Neutron Measurements on Mars

Here, the Probing In situ with Neutrons and Gamma rays (PING) instrument is an innovative application of active neutron-induced gamma-ray technology. The objective of PING is to measure the elemental composition of the Martian regolith. As part 2 of a two-part submission, this manuscript presents PING's sensitivities as a function of the Martian regolith depth and PING's uncertainties in the measurements as a function of observation time in passive and active mode. Part 1 of our submission models the associated regolith types. The modeled sensitivities show that in PING's active mode, where both a Pulsed Neutron Generator (PNG) and a Gamma-Ray Spectrometer (GRS) are used, PING can interrogate the material below the rover to about 20 cm due to the penetrating nature of the high-energy neutrons and the resulting secondary gamma rays observed with the GRS. PING is capable of identifying most major and minor rock-forming elements, including H, O, Na, Mn, Mg, Al, Si, P, S, Cl, Cr, K, Ca, Ti, Fe and Th. The modeled uncertainties show that PING's use of a PNG reduces the required observation times by an order of magnitude over a passive operating mode where the PNG is turned off. While the active mode allows for more complete elemental inventories with higher sensitivity, the gamma-ray signatures of some elements are strong enough to detect in passive mode. We show that PING can detect changes in key marker elements and make thermal neutron measurements in about 1 minute that are sensitive to H and Cl.