Search NASA⌕ Search

SEARCH · Search NASA

Results for “Non-Destructive Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microstructurally resolved electrochemical evolution of mechanical- and irradiation-induced damage in nuclear alloys

Abstract There is a need for high-throughput, scale-relevant, and direct electrochemical analysis to understand the corrosion behavior and sensitivity of nuclear materials that are exposed to extreme (high pressure, temperature, and radiation exposure) environments. We demonstrate the multi-scale, multi-modal application of scanning electrochemical cell microscopy (SECCM) to electrochemically profile corrosion alterations in nuclear alloys in a microstructurally resolved manner. Particularly, we identify that both mechanically deformed and irradiated microstructures show reduced charge-transfer resistance that leads to accelerated oxidation. We highlight that the effects of mechanical deformation and irradiation are synergistic, and may in fact, superimpose each other, with implications including general-, galvanic-, and/or irradiation-activated stress-corrosion cracking. Taken together, we highlight the ability of non-destructive, electrochemical interrogations to ascertain how microstructural alterations result in changes in the corrosion tendency of a nuclear alloy: knowledge which has implications to rank, qualify and examine alloys for use in nuclear construction applications.

Chen, Xin↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

FTIR imaging identifies alterations in lung tissue structure and biochemical composition in human idiopathic pulmonary fibrosis

Idiopathic Pulmonary Fibrosis (IPF) is a chronic, progressive, and fatal lung disease characterized by damage to the epithelial tissue and a reduced ability of the alveoli to repair themselves. This impaired repair process leads to abnormal accumulation of extracellular matrix (ECM), resulting in scarring and stiffening of lung tissue. Fourier transform infrared imaging (FTIRI) is a promising technique for imaging the biochemical changes related to fibrotic changes in a label-free and non-destructive manner, which can be analyzed to mark the progression of IPF. In this study, FTIRI was used to image human lung tissue biopsies with IPF and control biopsies without disease. In-depth spectral analyses were performed to observe the biochemical changes in the tissue composition using FTIRI. The parameters that were analyzed included collagen structure, total lipid content, lipid chain length, and phospholipids. Results showed a significant increase in lipid content in IPF compared to control, where long chain lipids dominated and phospholipids were reduced. Minor changes in collagen structure were also observed in IPF, likely attributed to the excess formation of extracellular matrix in the disease. These findings indicate that FTIRI has the potential to be a promising diagnostic technique to understand the molecular changes during IPF, as analysis of infrared data can reveal detailed biochemical information regarding disease progression and provide spatial insights on the molecular changes across the IPF lung tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Prospecting for Critical Minerals and Rare Earth Elements from Marcellus Shale in the Western Portion of the Appalachian Basin with Non-Destructive Core Characterization

Identification of sources for domestic critical minerals and rare earth elements (CM/REE) has been deemed essential for the energy transition by the United States Department of Energy (DOE). The U.S. DOE’s National Energy Technology Laboratory’s (NETL) Geomaterials Characterization Laboratory has performed non-destructive core characterizations on energy-relevant rock cores for the past decade. During this time, NETL has published over 36 technical reports and made the associated data publicly available. Much of this work focuses on unconventional shale gas, subsurface carbon storage systems, and carbon-ore. These efforts provide cm-scale petrophysical and elemental data, photographic documentation, detailed core descriptions, and computed tomography (CT) data for each well. This provides a first phase prospecting resource for CM/REE resources and can provide a map for pin-pointing intervals and lithologies for further development. Using historical core characterization data from 12 Marcellus wells from the western portion of the Appalachian Basin, this study builds an improved understanding of the chemostratigraphy of the basin. X-ray fluorescence (XRF) and CT images were used to determine lithologic intervals and potential ore bodies for further analysis, including benchtop digestion and inductively coupled plasma mass spectrometry (ICP-MS) to better understand the CM/REE enrichments.

Paronish, Thomas J.↗

A Scalable & Non-Destructive Characterization Strategy to Study Semiconductor/Dielectric Interfaces and Predict Wafer-Level Device Performance

The defect density present at the dielectric-semiconductor interface in an MOS structure directly influences the channel carrier characteristics in semiconductor devices, especially in wide bandgap material systems used in power devices. While these trap defects are typically quantified through electrical characterization of MOS-capacitor test structures, this treatment offers very little insight into the physical nature of interface defects. Such shortcomings demand a physical characterization strategy to guide fabrication optimization. X-ray photoelectron spectroscopy (XPS) is suggested as a viable technique to determine chemical data for dielectric interfaces formed using atomic layer deposition (ALD) on GaN substrates. Previously, 1-D XPS characterization has confirmed the presence of a Ga x O y interlayer between ALD dielectrics and the GaN substrate. In this work, XPS data is serially collected to form 2-D images of an ALD-Al 2 O 3 /GaN interface as a proof-of-concept experiment for in-situ XPS quality monitoring during ALD processing. The information provided by this work reveals some of the challenges for incorporating XPS characterization as an in-situ strategy during fabrication of GaN-based devices. Separately, electrical mapping of a 2-D array of ALD-Al 2 O 3 /GaN MOS-capacitor devices provide a means to quantify the spatial variations in interface quality across a single wafer. Physical characterization techniques, such as time-of-flight secondary ion mass spectroscopy, provide additional chemical information about the Al 2 O 3 /Ga x O y /GaN structure that complement the electrical mapping results. This analysis shows that a higher Ga x O y content correlates with higher interface state defects for trap energies deep in the band gap.

42 ENGINEERING↗

Temperature Dependence of FDR Response for Thermally Aged Low-Voltage Cables

Frequency Domain Reflectometry (FDR) has attracted significant attention for use in nuclear power plants (NPPs) for non-destructive cable health monitoring. However, cable aging detection using FDR faces challenges due to its high sensitivity to environmental factors such as temperature, vibrations, proximity to other cables, and so on. This work aims to evaluate the influence of measurement temperature on the FDR reflected signal in a low voltage cable undergoing accelerated thermal aging. A 100 ft long multi-core low-voltage unshielded power cable insulated with flame retardant ethylene propylene rubber (FR-EPR) and covered by a chloro-polyethylene (CPE) jacket was selected for this study. The cable was energized during aging by a 480 VAC 3-phase motor, and a 30 ft mid-section of this cable was routed through an air circulating oven held at 140 °C for up to an effective aging time of 62 days. FDR measurements were taken periodically with the oven on (at 140 °C) and with the oven off (at 22 °C). A comparative analysis of data collected at both temperatures showed that the FDR response was strongly dependent on measurement temperature. FDR measurements at ambient temperature showed large peaks corresponding to impedance changes in the aged section of the cable after 3 days of aging. These peaks continued to rise steadily with increasing aging time. However, for measurements taken at 140 °C, slowly rising peaks in the oven region (aged section) were observed only after a lead time of 23 days of aging. This work highlights the importance of measurement temperature on the performance of FDR as a condition monitoring tool for aging cables.

Sriraman, Aishwarya↗

PV backsheets survey protocol: A framework for geo-spatial field surveys for bulk material characterization and reliability analysis applied across 41 PV systems

As widespread adoption of photovoltaic (PV) technologies continues, understanding the lifetime of modules is paramount to the viability of the industry as an environmentally conscious alternative to traditional energy generation. Although power degradation can affect the total energy production of a module over its lifetime, module safety failures necessitate the removal of a module leading to a loss of not only the particular asset, but the earning potential of the device. Therefore, it is critical to ensure that the components that provide essential safety functions for PV module operate for their entire rated lifetime. PV backsheets provide necessary electrical insulation to the completed device and failure of this component is cause for a immediate removal of the module. Degradation of the PV module backsheet has led to module safety failures in large-scale installations, costing millions of dollars in damages and lost potential revenue. The spatio-temporal degradation of fielded PV modules is important to study in order to identify which modules within installations are experiencing the greatest exposure conditions and in turn have the highest chance of failure. This paper describes a comprehensive field survey protocol developed for monitoring PV module backsheet performance using solely non-destructive methods in commercial PV fields. The protocol establishes a field naming convention, sampling method, data handling requirements, and measurement procedures. By ensuring consistent data collection practices, the field survey protocol enables research groups to obtain data of uniform quality on backsheet performance over multiple years and locations. In this study, the developed protocol was implemented at forty-one PV sites. Eight different types of airside layer backsheet materials including poly(vinylidene fluoride) (PVDF), acrylic PVDF, poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), fluoroethylene vinyl ether (FEVE), polyethylene naphthalate (PEN), and glass were identified using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The field survey results show that the spatial distribution of degradation indicators are non-uniform within a particular module, individual site, and across site locations. The degradation of PV modules increased in severity for modules mounted at the edge of rows (across a field) and near the junction box (within a module). This study demonstrates the sensitivity of material performance to exposure length across different materials and climates.

14 SOLAR ENERGY↗

Enzymatically hydrolyzed fluorescence-based chemical probe enables in situ mapping of chitinase activity in the rhizosphere

Rhizosphere microbiomes and root exudates play a pivotal biochemical role in helping to catalyze chitin catabolism. Chitin is a recalcitrant and ubiquitous soil biopolymer, estimated to be the second most abundant organic soil biopolymer on Earth. Despite its abundance, role as a source of C and N in soil, and importance to ecosystem function, the biochemical mechanisms controlling chitin fate in the rhizosphere are elusive and poorly understood. To enable spatial mapping of chitinase activity in the rhizosphere, we designed and synthesized an enzymatically activated fluorogenic substrate, chitotriose-TokyoGreen (chitotriose-TG), by incorporating a fluorescein derivative (TG) onto the trimeric unit of chitin. This non-fluorescent substrate is selectively hydrolyzed by chitinase to release TG and yield a high fluorescence signal, which can be used to spatially image and measure chitinase activity in the rhizosphere. To demonstrate the application of this technique, we grew switchgrass (Panicum virgatum) in rhizoboxes amended with a horizontal layer of chitin. We extracted mobile proteins from the rhizobox using a nitrocellulose membrane blotting technique which offer non-destructive enzyme extraction while preserving the 2D spatial position of the enzymes. We then subjected these membranes to the synthesized chitotriose-TG stain to spatially visualize the distribution of chitinase activity within the rhizosphere. Furthermore, we observed increased chitinase activity near plant roots and higher activity within the soil zone enriched in chitin, showing an adaptive response of chitinase activity with spatial focusing in areas of higher chitin abundance. Thus, the enzyme extraction and visualization strategy we describe here can help enlighten efforts to better understand spatial controls on chitin breakdown in rhizosphere, further elucidating the role of chitin as a C and N source in these systems.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration of acoustic monitoring for structural health of microreactors: Through use of neural networks and resonant ultrasound spectroscopy

Nuclear microreactors prioritize modularity and portability and are intended to be a cost-effective technology for non-conventional nuclear markets. As such, the development of microreactors into a safe and feasible solution for energy security applications will necessitate the development of non-destructive technologies to monitor the integrity of inaccessible reactors components during operation. This demonstration applies linear and nonlinear acoustic techniques, in combination with machine learning, to detect and classify mechanical changes (stress and damage) in a test article which are broadly representative of potential operating challenges within a functioning microreactor. All necessary data has been collected for this demonstration, with minor experimental issues identified that can be addressed in follow-on work. Motivated by the expected conditions within a functioning microreactor, we have demonstrated our monitoring techniques on a core-block-like test article using an unstructured excitation source that approximates the noisy acoustic environment expected during reactor operation. At all stress states mechanically applied to the test article, a machine learning model using an artificial neural network was able to classify with 100% accuracy whether a 3D laser vibrometry point measurement was made on an intact or artificially defective test article. Further, model predictions about whether the defect interface was rough or smooth were 95% accurate, indicating the ability of acoustic techniques to recover defect characteristics. Resonant ultrasound spectroscopy (RUS) was also applied to the dataset to provide further quantitative insights about material properties. RUS analysis was ultimately hampered by several minor experimental and data issues, limiting results to certain cases for this demonstration. Last, analysis using nonlinear RUS exhibited sensitivity to changing levels of applied stresses for each intact and defective state. As presented in this demonstration, acoustic monitoring exhibits sensitivity to stress changes, which are of concern due to high thermal gradients expected during startup and operation. Further, our techniques distinguish between measurements made on intact and damaged test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Properties for Microsample Identification

A study was conducted to determine if individual particle characteristics could be used to identify particles of interest, sub-samples, from bulk post-detonation debris. Three archived post-detonation debris samples were used for this effort. Particles from these samples were identified as active (produced fission tracks), and inactive (did not produce fission tracks), as the first defining characteristic. Morphology was the secondary characteristic to select particles for further study, i.e. spherical/non-spherical. Once particles were identified and isolated, they were characterized by optical microscopy for size in µm, number of fission tracks, morphology, transmitted light color, and reflected light color. Particles were then analyzed by scanning electron microscopy for morphology, elemental content, and compound identification. Raman spectroscopy was attempted on five particles with indeterminate results due to environmental mixing (heterogeneity) during the events of particle formation. Once all non-destructive analyses were completed all particles were analyzed by thermal ionization mass spectrometry to determine isotopic atom percents of plutonium and uranium, and an estimate of atoms of plutonium and uranium in each particle. An estimate of the ratio of uranium to plutonium was also obtained (U/Pu). Data analytics of the data from the particles showed that combining characteristics of the particles have a high probability of identifying particles of interest from bulk post-detonation debris samples. Please note that this version of the report is an abridged version of the full report (Wagnon et al. 2025) that has been edited to be appropriate for public release.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The use of digital thread for reconstruction of local fiber orientation in a compression molded pin bracket via deep learning

A deep convolutional neural network (DCNN) was used for microstructure reconstruction using artificial intelligence (MR-AI) by predicting local average fiber orientation distributions (FOD) in a 3D prepreg platelet molded composite (PPMC) pin bracket. To train the MR-AI model, surface strain fields from residual stresses simulated in PPMC plates were used as the input to the DCNN. A training dataset included PPMC plates with various degrees of global fiber alignment, based on the information obtained from high-fidelity flow simulation of a pin bracket. Further, the MR-AI model was then deployed to analyze FOD in the 3D pin bracket by conducting thermo-elastic residual stress analysis. Initially, the MR-AI model was established entirely on the synthetic simulation data. Then, a μCT scan of a physically molded pin bracket was used to create a finite element model that provided data for additional validation of the DCNN model. For the μCT scan finite element pin bracket the MR-AI model predicted the distribution of fiber orientation tensor components with MAE of 0.10 indicating a global prediction error of 10%. For the flow simulated pin bracket, the MR-AI model predicted the distribution of fiber orientation tensor components with a global prediction error of 11%. The MR-AI model showed the ability to predict regions of varying alignment in the base and flange of the pin bracket. The proposed MR-AI methodology allows for rapid prediction of FOD in geometrically complex parts and offers a promising path to detecting unique fiber orientation states in molded components.

42 ENGINEERING↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive, whole-plant phenotyping reveals dynamic changes in water use efficiency, photosynthesis, and rhizosphere acidification of sorghum accessions under osmotic stress

Noninvasive phenotyping can quantify dynamic plant growth processes at higher temporal resolution than destructive phenotyping and can reveal phenomena that would be missed by end-point analysis alone. Additionally, whole-plant phenotyping can identify growth conditions that are optimal for both above- and below-ground tissues. However, noninvasive, whole-plant phenotyping approaches available today are generally expensive, complex, and non-modular. We developed a low-cost and versatile approach to noninvasively measure whole-plant physiology over time by growing plants in isolated hydroponic chambers. We demonstrate the versatility of our approach by measuring whole-plant biomass accumulation, water use, and water use efficiency every two days on unstressed and osmotically stressed sorghum accessions. We identified relationships between root zone acidification and photosynthesis on whole-plant water use efficiency over time. Our system can be implemented using cheap, basic components, requires no specific technical expertise, and should be suitable for any non-aquatic vascular plant species.

59 BASIC BIOLOGICAL SCIENCES↗

Finding a needle in a haystack: quantitative HERFD-XRF imaging and HERFD-XANES characterization of trace platinum in gold solidi from the Late Roman and Byzantine Empires

High-Energy Resolution Fluorescence Detection X-Ray Fluorescence (HERFD-XRF) imaging and HERFD X-ray Absorption Near Edge Structure (XANES) spectroscopy are used to quantify and characterize trace platinum (Pt) in gold solidi from the Late Roman and Byzantine Empires. Historically, the elemental analysis of coins has been pivotal in distinguishing authentic artifacts from forgeries, elucidating minting practices, and understanding economic shifts. Notably, a new gold source with high platinum content appeared in the fourth century CE, transforming the Roman economy. Traditional methods struggled to detect platinum due to the overwhelming gold matrix. Here, this study demonstrates the effectiveness of HERFD techniques in resolving this challenge. Three gold solidi, minted between 654 and 659 CE, were analyzed alongside reference gold materials with known Pt concentrations. The HERFD-XRF imaging revealed spatial distributions of platinum, highlighting non-uniformities within the coins. Additionally, HERFD-XANES spectroscopy identified the oxidation states and chemical speciation of platinum. Results demonstrate that platinum in the solidi primarily exists as metallic Pt, with some surface oxidation. The findings align with previous measurements but reveal higher Pt concentrations and significant inhomogeneities. This research confirms the reliability of HERFD methods for quantifying trace elements and provides new insights into the raw material sources and minting techniques of ancient gold coins. The non-destructive nature of this approach allows for extensive analyses, offering valuable data for historical, economic, and archaeological studies. This innovative application of HERFD-XRF imaging and XANES in cultural heritage research underscores the potential for detailed material characterization and conservation, enhancing our understanding of ancient economies and trade patterns.

Van Loon, Lisa L.↗

Quantifying Moss Response to Metal Contaminant Exposure Using Laser-Induced Fluorescence

Tracing sources of contamination, including potentially toxic elements (PTEs), has historically been achieved through sampling and analysis of soil or biota, which are labor-intensive, costly, and destructive methods. Thus, availability of a non-destructive in situ remote sensing method for monitoring metals deposited in biota is of great interest. Laser-induced fluorescence (LIF) is an emerging spectroscopic and imaging technique that documents changes in molecular energy level in plants as a biological response to metal contamination. For a proof-of-concept study and preliminary experiment, moss was selected for experimentation due to its long history of use in tracing atmospheric deposition of PTEs. Consecutive treatments of copper chloride (CuCl2) were administered to three moss samples, simulating wet deposition every 48 h over 10 days until reaching cumulative Cu concentrations of 2.690 to 8.075 μmol/cm2. While these Cu amounts are above environmentally relevant concentrations, they allowed the best conditions for testing and fine tuning of the imaging and data processing protocols presented in this paper. Moss fluorescence was induced using both 532 nm green and 355 nm UV lasers. A CMOS camera captured images of the LIF response, and red–green–blue (RGB) decimal code values were extracted for each pixel in the images, and pixel densities of color channels from treated and untreated moss samples were compared. Results show a shift towards lower color decimal codes corresponding to increased Cu concentration. We developed and contrasted multiple quantitative analyses of color distributions and demonstrated that LIF shows great promise for remote sensing of Cu accumulation in moss at μmol/cm2 levels. Though currently, the method would be limited to highly toxic sites, it illustrates the possibility and provides a framework for development of higher-sensitivity methods to detect nmol/cm2 that are viable for urban contamination level monitoring.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗