Thermodynamic modeling of countercurrent chemical looping reverse water gas shift process for redox material screening

The reverse water gas shift (RWGS) reaction is a key pathway for CO 2 utilization, particularly within Power-to-X process chains aimed at sustainable fuel and chemical production. Countercurrent chemical looping (CL-RWGS) using non-stoichiometric oxides can overcome equilibrium limitations of conventional RWGS reactors, enabling significantly higher CO 2 conversions. However, modeling the limiting performance of such systems is challenging due to their multiphase nature and coupled spatial and temporal variation in chemical composition. In this work, we present a discretized batch equilibrium model that simulates CL-RWGS reactors as a series of localized equilibrium exchanges between gas and solid elements. The model is numerically stable, computationally efficient, and free of kinetic source terms, making it well-suited for parametric studies and system-level integration. It is validated against established convection–diffusion models and shown to predict reasonable upper bounds on experimental results. Application of the model to a range of oxygen carrier materials identifies cerium–zirconium solid solutions, particularly Ce 0.80 Zr 0.20 O 2 , as a promising class offering superior oxygen storage characteristics compared to state-of-the-art La 0.6 Sr 0.4 FeO 3 . This framework provides a robust platform for materials screening, reactor sizing, and performance optimization in chemical looping systems. The model implementation is available as open-source software to support further research and development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Considerations of open-loop, closed-loop, and adaptive multicyclic control systems

Four different types of self-tuning regulators were studied for multicyclic control of helicopter vibration. A numerical simulation of the helicopter is made, using a multivariable frequency-domain model, in terms of transfer function with six input control harmonics and six output harmonics. The model characteristics vary with flight speed. An off-line identification of model characteristics is made, using the least-squared-error method and using a succession of input and output measurements. The on-line identification of model characteristics is made using the Kalman filter solution. The optimal controls are calculated from the minimization of quadratic performance function based on response and multicyclic inputs. The performance of various regulators or controllers is judged from the stability, transient response, convergence time, and amplitude of the steady state.

Chopra, I.↗

A short cut integration scheme to determine the dynamic response of a launch vehicle with several payloads

The coupled base motion equations of a system composed of a launch vehicle and several payloads are derived. In previous work it was shown how the special form of these equations allow for a quick and accurate solution both for the response and the loads of the system. In this paper a short-cut version of this direct integration technique is presented and evaluated. The result is a method which, depending on the nature of the structure at hand, vasilates between a full-scale coupled base motion approach and an open loop base drive method. Although completely general, the presented technique is most effective when the number of interface degrees of freedom is relatively small compared to the overall number of degrees of freedom of the system. The S.T.S.-S.T.-O.M.S. Kit system is used as an illustrative example.

Engels, R. C.↗

Real Km-synthesis via generalized Popov multipliers

The authors refine their H-infinity control designs presented at the 1990 and 1991 American Control Conference by introducing a new real Km-synthesis technique involving the use of generalized Popov multipliers. This multiplier technique substantially reduces, and in some cases may even eliminate altogether, the conservativeness associated with traditional Km-synthesis solutions in which all uncertainties are treated as complex, even when they arise from real parameters such as the masses and spring constants in the benchmark problem. The design results demonstrate how this approach permits a very precise analysis of the intrinsic tradeoffs between robustness, performance, and control energy requirements. Also included is an open-loop H-infinity prefilter design that makes it possible to address the command response shaping issue. The design concept has been applied to the benchmark problem no. 4 and successfully removes the initial undesired transient and cuts down the percent overshoot.

Chiang, R. Y.↗

A Privacy Preserving Model-Free Optimization and Control Framework for Demand Response from Residential Thermal Loads

We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.

Sivaranjani, S.↗

The first DEP domain of the RhoGEF P-Rex1 autoinhibits activity and contributes to membrane binding

Phosphatidylinositol (3,4,5)-trisphosphate (PIP 3 )-dependent Rac exchanger 1 (P-Rex1) catalyzes the exchange of GDP for GTP on Rac GTPases, thereby triggering changes in the actin cytoskeleton and in transcription. Its overexpression is highly correlated with the metastasis of certain cancers. P-Rex1 recruitment to the plasma membrane and its activity are regulated via interactions with heterotrimeric Gβγ subunits, PIP 3 , and protein kinase A (PKA). Deletion analysis has further shown that domains C-terminal to its catalytic Dbl homology (DH) domain confer autoinhibition. Among these, the first dishevelled, Egl-10, and pleckstrin domain (DEP1) remains to be structurally characterized. DEP1 also harbors the primary PKA phosphorylation site, suggesting that an improved understanding of this region could substantially increase our knowledge of P-Rex1 signaling and open the door to new selective chemotherapeutics. Here we show that the DEP1 domain alone can autoinhibit activity in context of the DH/PH-DEP1 fragment of P-Rex1 and interacts with the DH/PH domains in solution. The 3.1 Å crystal structure of DEP1 features a domain swap, similar to that observed previously in the Dvl2 DEP domain, involving an exposed basic loop that contains the PKA site. Using purified proteins, we show that although DEP1 phosphorylation has no effect on the activity or solution conformation of the DH/PH-DEP1 fragment, it inhibits binding of the DEP1 domain to liposomes containing phosphatidic acid. Thus, we propose that PKA phosphorylation of the DEP1 domain hampers P-Rex1 binding to negatively charged membranes in cells, freeing the DEP1 domain to associate with and inhibit the DH/PH module.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of Robust Adaptive Unbalance Response Controllers for Rotors with Magnetic Bearings

Experimental results have recently demonstrated that an adaptive open loop control strategy can be highly effective in the suppression of unbalance induced vibration on rotors supported in active magnetic bearings. This algorithm, however, relies upon a predetermined gain matrix. Typically, this matrix is determined by an optimal control formulation resulting in the choice of the pseudo-inverse of the nominal influence coefficient matrix as the gain matrix. This solution may result in problems with stability and performance robustness since the estimated influence coefficient matrix is not equal to the actual influence coefficient matrix. Recently, analysis tools have been developed to examine the robustness of this control algorithm with respect to structured uncertainty. Herein, these tools are extended to produce a design procedure for determining the adaptive law's gain matrix. The resulting control algorithm has a guaranteed convergence rate and steady state performance in spite of the uncertainty in the rotor system. Several examples are presented which demonstrate the effectiveness of this approach and its advantages over the standard optimal control formulation.

Knospe, Carl R.↗

Parametric robust control and system identification: Unified approach

Despite significant advancement in the area of robust parametric control, the problem of synthesizing such a controller is still a wide open problem. Thus, we attempt to give a solution to this important problem. Our approach captures the parametric uncertainty as an H(sub infinity) unstructured uncertainty so that H(sub infinity) synthesis techniques are applicable. Although the techniques cannot cope with the exact parametric uncertainty, they give a reasonable guideline to model the unstructured uncertainty that contains the parametric uncertainty. An additional loop shaping technique is also introduced to relax its conservatism.

Keel, Leehyun↗

Error Sources and Mitigation Strategies for Thermocouples Integrated in Flexible Thermal Protection System Materials

Brief Presenter Biography:Ruth Miller is an aer-ospace systems engineer in the Entry Systems and Ve-hicle Development Branch at NASA Ames Research Center.Introduction:The flexible thermal protection sys-tem (FTPS) on NASA’s Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle will be in-strumented with thermocouples (TCs) to measure the in-depth thermal response during entry into Earth’s atmos-phere[1, 2]. Accurate flight temperature measurements are critical for verifying vehicle performance during the flight test and reducing uncertainties in the thermal models.However,the deployable nature of inflatable decelerator technology presents challengesfor integrat-ing TCs, specifically the TCsneed to be compactableand cannot damage the FTPSnor the inflatable structure(IS).Unlike traditional rigid aeroshells, routing TCsthrough the thickness of the FTPS could cause signifi-cant damage during packing of the deployable aeroshellbecause the different layers may shift small amounts in relation to each other imparting strain on the TCsand FTPS materials. The LOFTID TCleads are routed from the measurement location back to the data acquisition system in the vehicle centerbody within the same FTPS layer that they are monitoring the temperature. This ap-proach eliminates the need to put holes in the FTPS lay-ers,butas a consequence,the insulated TCleads travel for an appreciable distance through a region that will expose them to high temperaturesand large thermal gra-dients.LOFTID’s TCswere baselined to be commercially available Type K TCswith a binder impregnated glass braid insulation. These TCswere chosen because they had been used successfully on IRVE-3 and in ground-based arc jet testing. Additionally, these TCsdid notdamage the FTPS nor IS during packing and deploy-ment testing. However, the glass braid insulation is only rated to a maximum continuous use temperature of 482ºC. For reference, the duration of the heat pulse on the LOFTID vehicle is on the order of minutes and themaximum predicted temperaturebeneaththe outermost FTPS layersis 1350ºC.Ground-based testing in a tube furnace at NASA Ames Research Centerwas conducted to determine if the baseline TCsrouted through FTPS samples would survive and provide accurate temperature measure-mentsat LOFTID flight-relevant temperatures[3].The test results showed large measurement errors occurred beginning at approximately 400°C due to conductive deposits on the TCinsulation electrically shorting the TCleads.The conductive deposits and thus electrical shorting weredetermined to be caused by twoerror sources:1.The organic binder on the TCinsulation carbon-izingin a high temperature, low oxygen envi-ronment2.Decomposition products from the FTPSperme-atingthe braided TC insulationFurther testing in the tube furnace demonstrated that heat cleaning the TCinsulation effectivelyremovedthe organic binder andeliminatedthe first error source.The second error sourcewas shown to be mitigated by the addition of amica wraparound each individual TCleadtoact as an impermeable barrier.To understand the applicability of theground-based tube furnace test results to flight,anarc jet testseriesat Boeing’s Large Core Arc Tunnel (LCAT) facilitywas conducted[4].The error sourcesand mitigation strate-giesidentified in the tube furnace testing were substan-tiatedin the arc jet testing.However, the arc jet testing also revealed three new error sources:1.Glass TCinsulation meltingwhich resultsin electrical shorting of the TCeither through di-rect contact between the two leads or through the electrically conductive FTPS materials2.TCwire meltingwhich results in a noisy and/or open-loop TCresponse3.Type K TCwire green-rotwhich results in large calibration errors Scope of the Presentation:This presentation will include a brief discussion onthe effect of electrical shorting on the output of a TC(i.e. how to identify elec-trical shorting in TCdataand what the associated erroris).The tube furnace and arc jet test resultswill be dis-cussedand the solutions LOFTID is implementing to mitigate the error sourcesidentified in the tube furnace and arc jet testingwill be presented.Additionally, futureresearch and development work to eliminateTCerror sourcesfor future missionswill be recommended.

R A Miller↗

Combined Thermal-Water Microgrid Model

SAND2022-3874 O The Combined Thermal-Water Microgrid Model is a set of three models combined with controls algorithms for a Water Thermal Storage (WTS), Ground Source Heat Pump (GSHP), and Thermal Bridge Loop (TBL) that serves a residential neighborhood. The model allows a parametric investigation of volume of water storage versus number of ground heat exchanger bore-holes versus seasonal energy efficiency measures. The code is being released as open source so that the entire study can be replicated per an open access journal publication. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Villa, Daniel↗

A technical analog of the cosmological constant problem and a solution thereof

The near vanishing of the cosmological constant is one of the most puzzling open problems in theoretical physics. We consider a system, the so-called framid, that features a technically similar problem. Its stress-energy tensor has a Lorentz-invariant expectation value on the ground state, yet there are no standard, symmetry-based selection rules enforcing this, since the ground state spontaneously breaks boosts. We verify the Lorentz invariance of the expectation value in question with explicit one-loop computations. These, however, yield the expected result only thanks to highly nontrivial cancellations, which are quite mysterious from the low-energy effective theory viewpoint.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Smart Composite Structures Including Debonding

Smart composite structures with distributed sensors and actuators have the capability to actively respond to a changing environment while offering significant weight savings and additional passive controllability through ply tailoring. Piezoelectric sensing and actuation of composite laminates is the most promising concept due to the static and dynamic control capabilities. Essential to the implementation of these smart composites are the development of accurate and efficient modeling techniques and experimental validation. This research addresses each of these important topics. A refined higher order theory is developed to model composite structures with surface bonded or embedded piezoelectric transducers. These transducers are used as both sensors and actuators for closed loop control. The theory accurately captures the transverse shear deformation through the thickness of the smart composite laminate while satisfying stress free boundary conditions on the free surfaces. The theory is extended to include the effect of debonding at the actuator-laminate interface. The developed analytical model is implemented using the finite element method utilizing an induced strain approach for computational efficiency. This allows general laminate geometries and boundary conditions to be analyzed. The state space control equations are developed to allow flexibility in the design of the control system. Circuit concepts are also discussed. Static and dynamic results of smart composite structures, obtained using the higher order theory, are correlated with available analytical data. Comparisons, including debonded laminates, are also made with a general purpose finite element code and available experimental data. Overall, very good agreement is observed. Convergence of the finite element implementation of the higher order theory is shown with exact solutions. Additional results demonstrate the utility of the developed theory to study piezoelectric actuation of composite laminates with pre-existing debonding. Significant changes in the modes shapes and reductions in the control authority result due to partially debonded actuators. An experimental investigation addresses practical issues, such as circuit design and implementation, associated with piezoelectric sensing and actuation of composite laminates. Composite specimens with piezoelectric transducers were designed, constructed and tested to validate the higher order theory. These specimens were tested with various stacking sequences, debonding lengths and gains for both open and closed loop cases. Frequency changes of 15% and damping on the order of more than 20% of critical damping, via closed loop control, was achieved. Correlation with the higher order theory is very good. Debonding is shown to adversely affect the open and closed loop frequencies, damping ratios, settling time and control authority.

Chattopadhyay, Aditi↗

Desensitized Aerocapture Guidance

Mission design flexibility can be increased using an aerocapture maneuver to capture into an orbit around a planet from a hyperbolic trajectory. In past work, bang-bang control has been shown as an optimal guidance solution that minimizes the $\Delta{V}$ required to get into a desired orbit using bank modulation. This work revisits aerocapture using a bank modulation problem to search for an optimal solution using a direct collocation method. Previous studies have shown that aerocapture performance is sensitive to atmospheric density. In the literature, several studies have used a desensitized control approach to make the optimal guidance more robust to uncertainties in the model. To this end, this work aims to develop a desensitized aerocapture guidance robust to uncertainty in atmospheric density. Furthermore, this work compares the robustness of the open-loop desensitized aerocapture guidance with optimal aerocapture guidance with an aerocapture application at Earth.

Pardha Sai Chadalavada↗

Desensitized Aerocapture Guidance

Mission design flexibility can be increased using an aerocapture maneuver to capture into an orbit around a planet from a hyperbolic trajectory. In past work, bang-bang control has been shown as an optimal guidance solution that minimizes the $\Delta{V}$ required to get into a desired orbit using bank modulation. This work revisits aerocapture using a bank modulation problem to search for an optimal solution using a direct collocation method. Previous studies have shown that aerocapture performance is sensitive to atmospheric density. In the literature, several studies have used a desensitized control approach to make the optimal guidance more robust to uncertainties in the model. To this end, this work aims to develop a desensitized aerocapture guidance robust to uncertainty in atmospheric density. Furthermore, this work compares the robustness of the open-loop desensitized aerocapture guidance with optimal aerocapture guidance with an aerocapture application at Earth.

Desensitized↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of linear quadratic regulators with eigenvalue placement in a specified region

Two linear quadratic regulators are developed for placing the closed-loop poles of linear multivariable continuous-time systems within the common region of an open sector, bounded by lines inclined at +/- pi/2k (for a specified integer k not less than 1) from the negative real axis, and the left-hand side of a line parallel to the imaginary axis in the complex s-plane, and simultaneously minimizing a quadratic performance index. The design procedure mainly involves the solution of either Liapunov equations or Riccati equations. The general expression for finding the lower bound of a constant gain gamma is also developed.

Shieh, Leang-San↗

Mapdfn.py

SAND2021-4824 O mapdfn.py takes the output of dfnWorks describing a discrete fracture network (DFN) and converts the DFN to an equivalent porous medium representation. This is done by looping through cells in a 3-D model domain, tagging those intersected by fractures, and calculating effective properties. Coordinate transformations are imported from an open source script (transformations.py) developed at the University of California. An associated driver script, mapdfn2pflotran.py, calls the functions in mapdfn.py and writes the mapdfn.py output to hdf5 files for use with PFLOTRAN. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-4824 O

Stein, Emily↗

Closed Form Solution for Minimum Norm Model-Validating Uncertainty

A methodology in which structured uncertainty models are directly constructed from measurement data for use in robust control design of multivariable systems is proposed. The formulation allows a general linear fractional transformation uncertainty structure connections with respect to a given nominal model. Existence conditions are given, and under mild assumptions, a closed-form expression for the smallest norm structured uncertainty that validates the model is given. The uncertainty bound computation is simple and is formulated for both open and closed loop systems.

Lim, Kyong Been↗