Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL EMISSION SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Emission Spectroscopy Characterization of Electrodes Species in the Freestream Flow at the NASA Ames Miniature Arc Jet II Facility

The second generation miniature Arc Jet (mARC II) is a subscale arc jet at NASA Ames Research Center that is undergoing initial characterization. During its operation, the electrodes used to produce continuous plasma flows deteriorate and the flow purity decreases. The present work reports the use of optical emission spectroscopy as a characterization tool for impurities in the plasma flow. The discussion is focused on the interpretation of spectroscopic measurements and their evolution under different testing conditions. Special emphasis is given to copper and silver, the main atomic elements of the electrodes. The highest rate of anode deterioration is found to occur during the arc jet ignition, while cathode deterioration is constant throughout the entire run. Based on the experimental spectra, a preliminary numerical characterization of the plasma temperature, enthalpy and number density is conducted.

facility↗

The interplay between laser focusing conditions, expansion dynamics, ablation mechanisms, and emission intensity in ultrafast laser-produced plasmas

The interplay between ultrafast laser focusing conditions, emission intensity, expansion dynamics, and ablation mechanisms is critical to the detection of light isotopes relevant to nuclear energy, forensics, and geochemistry applications. Here, we study deuterium (2Hα) emission in plasmas generated from femtosecond laser ablation of a Zircaloy-4 target with a deuterium concentration of ≈37 at. %. Changes in emission intensity, plume morphology, crater dimensions, and surface modifications were investigated for varying focusing lens positions, where the laser was focused behind, at, and in front of the target. Spatially resolved optical emission spectroscopy and spectrally integrated plasma imaging were performed to investigate emission spectral features and plume morphology. Laser ablation crater dimensions and morphology were analyzed via optical profilometry and scanning electron microscopy. The 2Hα emission intensity showed significant reduction at the geometrical focal point or when the focal point is in front of the target. For all laser spot sizes, a two-component plume was observed but with different temporal histories. At the best focal point, the plume was spherical. When the laser was focused behind the target, the plume was elongated and propagated to farther distances than for the best focal position. In contrast, when the laser was focused in front of the target, filaments were generated in the beam path, and filament-plasma coupling occurred. By focusing the laser behind the target, the amount of material removal in the laser ablation process can be significantly reduced while still generating a plasma with a sufficient 2Hα emission signal for analysis.

Kautz, Elizabeth J. (ORCID:0000000263389223)↗

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

ABSTRACT Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. Our results demonstrate a distinct correlation between fungal species and their elemental profile, regardless of the substrate media, as the same strains shared a similar uptake of carbon, zinc, phosphorus, manganese, and magnesium, which could play a vital role in their survival and propagation. Independently, each fungal species exhibited a unique elemental profile. This work demonstrates a unique and valuable approach to rapidly phenotype fungi through optical spectroscopy, and this approach can be critical in understanding these fungi's behavior and interactions with the environment. IMPORTANCE Historically, ionomics, the elemental profiling of an organism or materials, has been used to understand the elemental composition in waste materials to identify and recycle heavy metals or rare earth elements, identify the soil composition in space exploration on the moon or Mars, or understand human disorders or disease. To our knowledge, ionomic profiling of microbes, particularly fungi, has not been investigated to answer applied and fundamental biological questions. The reason is that current ionomic analytical techniques can be laborious in sample preparation, fail to measure all potential elements accurately, are cost-prohibitive, or provide inconsistent results across replications. In our previous efforts, we explored whether laser-induced breakdown spectroscopy (LIBS) could be used in determining the elemental profiles of poplar tissue, which was successful. In this proof-of-concept endeavor, we undertook a transdisciplinary effort between applied and fundamental mycology and elemental analytical techniques to address the biological question of how LIBS can used for fungi grown axenically in a nutrient-rich and nutrient-poor environment.

59 BASIC BIOLOGICAL SCIENCES↗

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. This data set contains the raw LIBS spectral data for the summarized results described inRush, et. al. 2024

elemental profiling↗

Molecular Iodine Interactions with Fe, Ni, Cr, and Stainless Steel Alloys

The adsorption behavior of molecular iodine is important for understanding the spread of radioiodine in a nuclear accident. Prior experiments indicate that, in addition to the interaction with Fe, molecular iodine [i.e., I 2(g) ] also interacts with the next most abundant components of austenitic stainless steel (i.e., Ni, and Cr) at room temperature. Here, we investigate iodine adsorption on Fe, Ni, and Cr while focusing on understanding the variables affecting adsorption as well as the iodine compounds that are formed during adsorption. Scanning electron microscopy and energy-dispersive X-ray spectroscopy were used to characterize the surfaces of exposed metal particles and aid in the understanding of the morphology and chemistry of iodine interactions with the substrates. Inductively coupled plasma optical emission spectroscopy was used to detect low levels of metal iodides and X-ray photoelectron spectroscopy was used to confirm the formation of the metal iodides. The role of environmental factors (e.g., humidity and oxygen content) for iodine adsorption on metal substrates is addressed. The individual metals demonstrated formation of metal iodides for Fe and Ni particles from interaction with I 2(g) . The formation of metal iodides may indicate the affinity of iodine for the respective metal. In this study, the iodine affinities ranked Fe > Ni > Cr as determined by the quantity of chemisorbed iodine. This trend is also supported by the distributions and proportions of metals in the corrosion product of the stainless steels. The exposures without oxygen and humidity indicate the potential of a multistep iodine adsorption process where iodine first attacks the oxide layer and then chemisorbs to the exposed metal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploration of ICP platforms for measuring elemental impurities in uranium ore concentrates

Presented here is a look at different inductively coupled plasma (ICP) platforms including sector field, triple quadrupole mass spectrometric configurations, and optical emission spectroscopy. The goal of this paper was to convey the feasibility of trace elemental analysis of a uranium ore concentrate with varying ICP-based platforms. It was predicted that low mass elements would be better determined through optical means, or the mass collision/reaction technology of the triple quadrupole mass spectrometer, in comparison to high resolution measurements of magnetic sector-based configurations. Ultimately, it is difficult to achieve an “optimal” analysis of 20+ elements, for numerous samples, on a single platform, especially when time, measurement reproducibility, sensitivity, and robustness should be considered. The work presented here highlights the advantages and disadvantages of the respective trace elemental analysis platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of ambient gas on self-reversal in Li transitions relevant to isotopic analysis

Laser induced breakdown spectroscopy is a promising, rapid analysis method for the detection and quantification of Li and its isotopes needed in geochemical, nuclear, and energy storage applications. However, spectral broadening in laser produced plasmas, presence of fine and hyperfine structures, and self-reversal effects make Li isotopic analysis via laser induced breakdown spectroscopy challenging. The present study explores the influence of Ar, N 2 , and He ambient gases over the pressure range of 0.05 - 100 Torr on line broadening and self-reversal of the Li I transition with the greatest isotopic shift in the VIS spectral region (i.e., ≈670.8 nm, ≈15.8 pm isotopic shift). We perform spatially and temporally resolved optical emission spectroscopy of plasmas produced via laser ablation of LiAlO 2 substrates. Our results show that the self-reversal and linewidth is reduced at lower pressures for all gases, and using optimized plasma conditions with chemometric methods, the 6 Li/ 7 Li isotopic ratios can be predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Age determination of a 75 Se gamma radiography source for nuclear forensics

Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Innovative recycling of high purity silver from silicon solar cells by acid leaching and ultrasonication

Precious and scarce silver (Ag) is used as a front electrical contact in silicon solar panels. With massive amounts of solar panel waste coming to end-of-life, it is imperative to recover all the Ag from these modules. In this paper, we propose a novel method to easily reclaim Ag from end-of-life silicon solar cells using low concentration sulfuric acid (H 2 SO 4 ) leaching followed by ultrasonication. Our process simplifies the Ag recycling procedure by directly recovering the Ag contacts from solar cells, eliminating the need for secondary precipitation/electrodeposition. First, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS) was used to study the leaching and ultrasonication process on rejected solar wafers. Next, a solar panel from landfill was heated in a furnace to burn off the polymer encapsulant. The silicon wafers were then collected from the burning process and leached in 2 M H 2 SO 4 at two different shaking speeds for 48 hours at room temperature. Finally, the end-of-life silicon wafer pieces were collected, sonicated in water, and then the sonication water was centrifuged to show a proof-of-concept to recover the Ag contacts. Inductively coupled plasma optical emission spectroscopy (ICPOES) is used to monitor dissolved elements in the leachate as a function of time and shaking speed. XPS is used to evaluate the composition of the silicon cell wafer surface before and after H 2 SO 4 leaching. SEM is used to image the recovered Ag contacts morphology and EDX confirms the recovered particles contain high amounts of Ag. Furthermore, a proposed schematic illustrates the authors’ hypothesis for the peeling mechanism.

14 SOLAR ENERGY↗

Quantification of Lanthanides in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy

To enable the deployment of molten salt reactor technology, the development of off-gas treatment systems and advanced monitoring tools capable of operating with high temperatures and radiation fields while delivering near real-time information is necessary. Here, we aim to fulfill this requirement and proposes laser-induced breakdown spectroscopy (LIBS) for monitoring molten salt aerosol streams. A sheath gas measuring method was developed to protect optical elements from aerosol particles and to ensure a relatively constant aerosol stream for measurement. An aqueous system was studied to demonstrate the utility of LIBS for monitoring possible fission products in an aerosol stream: Gd, Nd, and Sm up to 2000 parts per million (ppm). A calibration model was built using partial least squares (PLS) regression with five, six, and nine latent variables for Gd, Nd, and Sm, respectively. This calibration model successfully estimated the concentrations of three test samples, which were validated with inductively charged plasma optical emission spectroscopy measurements at a 99.9% confidence interval. To enhance these models, a genetic algorithm was used to filter the spectra before entering the PLS model, thereby limiting the spectral features being regressed to those with greater correlations to concentration. This allowed for the number of latent variables used in the PLS models to be reduced to four, three, and three for Gd, Nd, and Sm, respectively. Finally, the genetic algorithm-filtered PLS models were used to predict the concentrations of the aerosol stream on a real-time dataset and resulted in a 73%, 18%, and 25% improvement in root mean squared error of prediction compared to the original PLS models developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stochastic optimization of a uranium oxide reaction mechanism using plasma flow reactor measurements

Abstract In this work, a coupled Monte Carlo Genetic Algorithm (MCGA) approach is used to optimize a gas phase uranium oxide reaction mechanism based on plasma flow reactor (PFR) measurements. The PFR produces a steady Ar plasma containing U, O, H, and N species with high temperature regions (3000–5000 K) relevant to observing UO formation via optical emission spectroscopy. A global kinetic treatment is used to model the chemical evolution in the PFR and to produce synthetic emission signals for direct comparison with experiments. The parameter space of a uranium oxide reaction mechanism is then explored via Monte Carlo sampling using objective functions to quantify the model-experiment agreement. The Monte Carlo results are subsequently refined using a genetic algorithm to obtain an experimentally corroborated set of reaction pathways and rate coefficients. Out of 12 reaction channels targeted for optimization, four channels are found to be well constrained across all optimization runs while another three channels are constrained in select cases. The optimized channels highlight the importance of the OH radical in oxidizing uranium in the PFR. This study comprises a first step toward producing a comprehensive experimentally validated reaction mechanism for gas phase uranium molecular species formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Diagnostic Characterization of High-Power Hall Thruster Wear and Operation

Optical emission spectroscopy is employed to correlate BN insulator erosion with high-power Hall thruster operation. Specifically, actinometry leveraging excited xenon states is used to normalize the emission spectra of ground state boron as a function of thruster operating condition. Trends in the strength of the boron signal are correlated with thruster power, discharge voltage, and discharge current. In addition, the technique is demonstrated on metallic coupons embedded in the walls of the HiVHAc EM thruster. The OES technique captured the overall trend in the erosion of the coupons which boosts credibility in the method since there are no data to which to calibrate the erosion rates of high-power Hall thrusters. The boron signals are shown to trend linearly with discharge voltage for a fixed discharge current as expected. However, the boron signals of the higher-power NASA 300M and NASA 457Mv2 trend with discharge current and show an unexpectedly weak to inverse dependence on discharge voltage. Electron temperatures measured optically in the near-field plume of the thruster agree well with Langmuir probe data. However, the optical technique used to determine Te showed unacceptable sensitivity to the emission intensities. Near-field, single-frequency imaging of the xenon neutrals is also presented as a function of operating condition for the NASA 457 Mv2.

Williams, George J., Jr.↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

Understanding the Benefit of Hybrid Electrolytes towards Vanadium Dissolution Suppression and Improved Capacity Retention in Zinc‐Aqueous Batteries Using NaV 3 O 8 Cathodes

Vanadate cathodes used in aqueous Zn-ion batteries with ZnSO 4 are hindered by capacity loss from V dissolution into the electrolyte. However, studies pinpointing the onset of dissolution as a function of electrochemical redox state and quantifying the amount of associated active material are lacking. To prevent dissolution of the NaV 3 O 8 active material, Na + ions are introduced into the electrolyte. Specifically, a hybrid ZnSO 4 + Na 2 SO 4 electrolyte is investigated in concert with NaV 3 O 8 (NVO) cathodes of varied crystallinity to determine the resulting impacts on cathode dissolution and functional electrochemistry. The use of Na + -containing hybrid electrolyte shows no significant change in Zn 2+ diffusion coefficients yet improved capacity retention. Time-resolved quantitative optical emission spectroscopy demonstrates the suppression of V dissolution with the hybrid electrolyte in both pristine and cycled electrodes. Operando synchrotron X-ray diffraction and absorption provide mechanistic insights. Hydrated NVO with wider interplanar spacing exhibits much higher H + /Zn 2+ capacity, while the Na 2 SO 4 mitigates the formation of irreversible side products. Furthermore, this study demonstrates that the use of hybrid electrolytes and control of crystallite size in the parent material can significantly improve electrochemical behavior of layered V-based cathodes in Zn-ion batteries, providing a general strategy toward safe and resilient aqueous battery systems.

36 MATERIALS SCIENCE↗

Identifying Regimes During Plasma Catalytic Ammonia Synthesis

Herein, we demonstrate that the performance of mesoporous silica SBA-15 and SBA-15-Ag during plasma ammonia synthesis depends on the plasma conditions. At high power, the mesoporous silica SBA-15 without Ag produces the largest amount of ammonia, but the addition of Ag provides a minor benefit at lower powers. Plasma conditions were analyzed through optical emission spectroscopy using N 2 , N 2 + , and NH molecular bands and H α line. Stark broadening of H α line was used to find electron density, and N 2 molecular bands were used to assess N 2 vibrational excitation, important for plasma nitrogen decomposition. At similar input conditions, reactors with SBA-15 have higher electron density and higher N 2 vibrational temperature. Consistent with higher electron density, SBA-15 reactors have stronger N 2 + emission intensity relative to the neutral N 2 . The addition of Ag results in higher N 2 rotational temperature, possibly due to localized heating. From the materials point of view, SBA-15 is a more robust catalyst with good surface area retention after plasma exposure due to the lack of local heating generated when a metal is in the structure. Furthermore, we identify two possible regimes during ammonia synthesis, a metal and a surface-plasma driven. At lower plasma densities, the addition of metal is beneficial, while at higher power and plasma density, the best performance is achieved without the aid of a metal catalyst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metal concentration and leaf spatial distribution assessed by synchrotron µXRF in Brazilian nickel hyperaccumulators

Background and Aims: The limited number of known hyperaccumulator species in tropical regions, including Brazil, has hampered the development of nickel (Ni) agromining. In addition, the mechanisms underlying metal accumulation and distribution in these species remain poorly understood, despite their pivotal role in identifying species with economic potential. Furthermore, this study assessed the accumulation potential and foliar spatial distribution of metals in three Brazilian hyperaccumulator species (Pfaffia sarcophylla, Justicia lanstyakii, and Lippia lupulina) growing in one of the world’s largest mafic–ultramafic complexes. Methods Concentrations of Ni and other metals in leaves were determined using portable X-ray fluorescence (pXRF) and inductively coupled plasma optical emission spectroscopy (ICP-OES). Synchrotron-based X-ray microfluorescence (SR-µXRF) was employed to map the spatial distribution of metals across intact leaves. Results: The results revealed leaf Ni concentrations ranging from 320 to 1,950 mg kg⁻ 1 in P. sarcophylla, 1,640 to 6,810 mg kg⁻ 1 in L. lupulina, and 1,990 to 4,900 mg kg⁻ 1 in J. lanstyakii. Nickel, Mn, and Co exhibited similar distribution patterns, concentrating mainly in the leaf margins and veins across all species, while Ca, K, and Mg co-localization suggests regulatory mechanisms for adaptation. Conclusion: Although these plants exhibited Ni hyperaccumulation, our findings suggest limited commercial potential for agromining. Further research on genetic variability and nutrient assimilation, particularly in P. sarcophylla, is recommended to elucidate the mechanisms underlying Ni accumulation and intraspecific variability.

36 MATERIALS SCIENCE↗