Search NASA⌕ Search

SEARCH · Search NASA

Results for “OXYGEN SENSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Linear Aerospike SR-71 Experiment (LASRE): Aerospace Propulsion Hazard Mitigation Systems

A major hazard posed by the propulsion system of hypersonic and space vehicles is the possibility of fire or explosion in the vehicle environment. The hazard is mitigated by minimizing or detecting, in the vehicle environment, the three ingredients essential to producing fire: fuel, oxidizer, and an ignition source. The Linear Aerospike SR-71 Experiment (LASRE) consisted of a linear aerospike rocket engine integrated into one-half of an X-33-like lifting body shape, carried on top of an SR-71 aircraft. Gaseous hydrogen and liquid oxygen were used as propellants. Although LASRE is a one-of-a-kind experimental system, it must be rated for piloted flight, so this test presented a unique challenge. To help meet safety requirements, the following propulsion hazard mitigation systems were incorporated into the experiment: pod inert purge, oxygen sensors, a hydrogen leak detection algorithm, hydrogen sensors, fire detection and pod temperature thermocouples, water misting, and control room displays. These systems are described, and their development discussed. Analyses, ground test, and flight test results are presented, as are findings and lessons learned.

Mizukami, Masashi↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

Measuring Absolute Oxygen Pressure

Sensor determines absolute pressure of oxygen without reference pressure source. Absolute oxygen pressure transducer with control circuit enables measurement without reference pressure. Transducer, two part device, combines solid electrolyte membranes sensor with diffusional orifice. Device adapted for direct control of oxygen pressure in combustion mixtures.

Richter, R.↗

Raman-based Oxygen and Nitrogen Sensor for Monitoring Empty Airplane Fuel Tanks

The purpose of this project was to develop a Raman-based method for detecting oxygen and nitrogen in empty fuel tanks. The need for such a method comes from the potential danger of allowing explosive oxygen-fuel mixtures to accumulate in empty airplane fuel tanks. An explosion resulting from such a mixture is believed to have caused the Flight TWA 800 disaster in 1996. Recently, (e.g., February 17,2004 press release) the FAA announced its intentions to make fuel tank inerting mandatory. One potential solution to this problem is to use an inert gas such as nitrogen to flood the empty fue1 tanks in order to reduce the concentration of oxygen.

Chen, Peter C.↗

Detecting oxygen in hydrogen or hydrogen in oxygen

Catalytic sensor operates in high-pressure, moisture-laden gases. It was developed for life support system in which water is decomposed by electrolysis to produce oxygen and hydrogen. Sensor has potential applications in gas-detection and measurement instruments, particularly for gases generated by electrolysis, because such gases may contain large amounts of moisture.

Erickson, A. C.↗

Pinhole cameras as sensors for atomic oxygen in orbit; application to attitude determination of the LDEF

Images produced by pinhole cameras using film sensitive to atomic oxygen provide information on the ratio of spacecraft orbital velocity to the most probable thermal speed of oxygen atoms, provided the spacecraft orientation is maintained stable relative to the orbital direction. Alternatively, as it is described, information on the spacecraft attitude relative to the orbital velocity can be obtained, provided that corrections are properly made for thermal spreading and a co-rotating atmosphere. The LDEF orientation, uncorrected for a co-rotating atmosphere, was determined to be yawed 8.0 minus/plus 0.4 deg from its nominal attitude, with an estimated minus/plus 0.35 deg oscillation in yaw. The integrated effect of inclined orbit and co-rotating atmosphere produces an apparent oscillation in the observed yaw direction, suggesting that the LDEF attitude measurement will indicate even better stability when corrected for a co-rotating atmosphere. The measured thermal spreading is consistent with major exposure occurring during high solar activity, which occurred late during the LDEF mission.

Peters, Palmer N.↗

Pinhole cameras as sensors for atomic oxygen in orbit: Application to attitude determination of the LDEF

Images produced by pinhole cameras using film sensitive to atomic oxygen provide information on the ratio of spacecraft orbital velocity to the most probable thermal speed of oxygen atoms, provided the spacecraft orientation is maintained stable relative to the orbital direction. Alternatively, information on the spacecraft attitude relative to the orbital velocity can be obtained, provided that corrections are properly made for thermal spreading and a corotating atmosphere. The Long Duration Exposure Facility (LDEF) orientation, uncorrected for a corotating atmosphere, was determined to be yawed 8.0 +/- 0.4 degrees from its nominal attitude, with an estimated +/- 0.35 degree oscillation in yaw. The integrated effect of inclined orbit and corotating atmosphere produces an apparent oscillation in the observed yaw direction, suggesting that the LDEF attitude measurement will indicate even better stability when corrected for a corotating atmosphere. The measured thermal spreading is consistent with major exposure occurring during high solar activity, which occurred late during the LDEF mission.

Peters, Palmer N.↗

NASA Tech Briefs, September 2003

Topics include: Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask; Three-Dimensional Venturi Sensor for Measuring Extreme Winds; Swarms of Micron-Sized Sensors; Monitoring Volcanoes by Use of Air-Dropped Sensor Packages; Capacitive Sensors for Measuring Masses of Cryogenic Fluids; UHF Microstrip Antenna Array for Synthetic- Aperture Radar; Multimode Broad-Band Patch Antennas; 164-GHz MMIC HEMT Frequency Doubler; GPS Position and Heading Circuitry for Ships; Software for Managing Parametric Studies; Software Aids Visualization of Computed Unsteady Flow; Software for Testing Electroactive Structural Components; Advanced Software for Analysis of High-Speed Rolling-Element Bearings; Web Program for Development of GUIs for Cluster Computers; XML-Based Generator of C++ Code for Integration With GUIs; Oxide Protective Coats for Ir/Re Rocket Combustion Chambers; Simplified Waterproofing of Aerogels; Improved Thermal-Insulation Systems for Low Temperatures; Device for Automated Cutting and Transfer of Plant Shoots; Extension of Liouville Formalism to Postinstability Dynamics; Advances in Thrust-Based Emergency Control of an Airplane; Ultrasonic/Sonic Mechanisms for Drilling and Coring; Exercise Device Would Exert Selectable Constant Resistance; Improved Apparatus for Measuring Distance Between Axles; Six Classes of Diffraction-Based Optoelectronic Instruments; Modernizing Fortran 77 Legacy Codes; Active State Model for Autonomous Systems; Shields for Enhanced Protection Against High-Speed Debris; Scaling of Two-Phase Flows to Partial-Earth Gravity; Neutral-Axis Springs for Thin-Wall Integral Boom Hinges.

Source record↗

A review of zirconia oxygen, NO x , and mixed potential gas sensors – History and current trends

Zirconia-based electrochemical sensors have revolutionized oxygen monitoring and combustion control. Here, these robust, solid-state devices are found in virtually every internal combustion engine today providing feedback information for tight air to fuel ratio control thus minimizing unwanted emissions and improving engine efficiency. Variations on the sensor design and operational mode enable the measurement of nitrogen oxides to part per million levels, providing control information for exhaust after-treatment systems. Emerging designs include the development of "gas analyzers on a chip" capable of monitoring oxygen, carbon monoxide, nitrogen oxides, ammonia and hydrocarbons.

47 OTHER INSTRUMENTATION↗

Development of a Portable Oxygen Monitoring System for Operations in the International Space Station Airlock

NASA is currently engaged in an activity to facilitate effective operations on the International Space Station (ISS) after the Space Shuttle retires. Currently, the Space Shuttle delivers crew and cargo to and from ISS. The Space Shuttle provides the only large scale method of hardware return from ISS to the ground. Hardware that needs to be periodically repaired, refurbished, or recalibrated must come back from ISS on the Shuttle. One example of NASA flight hardware that is used on ISS and refurbished on the ground is the Compound Specific Analyzer for Oxygen (CSA-O2). The CSA-O2 is an electrochemical sensor that is used on orbit for about 12 months (depending on Shuttle launch schedules), then returned to the ground for sensor replacement. The shuttle is scheduled to retire in 2010, and the ISS is scheduled to operate until 2016. NASA needs a hand held sensor that measures oxygen in the ISS environment and has a 5-10 year service life. After conducting a survey of oxygen sensor systems, NASA selected a Tunable Diode Laser Absorption Spectrometer (TDLAS) as the method of measurement that best addresses the needs for ISS. These systems are compact, meet ISS accuracy requirements, and because they use spectroscopic techniques, the sensors are not consumed or altered after making a measurement. TDLAS systems have service life ratings of 5-10 years, based on the lifetime of the laser. NASA is engaged in modifying a commercially available sensor, the Vaisala OMT 355, for the ISS application. The Vaisala OMT 355 requires three significant modifications to meet ISS needs. The commercial sensor uses a wall mount power supply, and the ISS sensor needs to use a rechargeable battery as its source of power. The commercial sensor has a pressure correction setpoint: the sensor can be adjusted to operate at reduced pressure conditions, but the sensor does not self correct dynamically and automatically. The ISS sensor needs to operate in the airlock, and make accurate measurements in an environment that can change from 14.7 psia to 10.2 psia in 15 minutes. The commercial sensor needs to be repackaged into a configuration that is more compact, and better suited for ISS airlock operations. NASA has recently completed a prototype of the reconfigured system. The unit has been repackaged in a way that the optical path of the spectrometer is unchanged, but the electronics has been integrated into a case measuring 10.7 X 7.2 X 3.0 inches. Two flight qualified rechargeable batteries have been integrated into system. The batteries can power the sensor for 10 hours on a single charge. A pressure sensor has been added to the system. The modified unit automatically compensates for changes in pressure, and meets 0.2% accuracy requirements for oxygen measurements in an environment with 18 to 32% oxygen across a pressure range of 10.0 to 15.0 psia.

Graf, John↗

Flight Hydrogen Sensor for use in the ISS Oxygen Generation Assembly

This paper provides a description of the hydrogen sensor Orbital Replacement Unit (ORU) used on the Oxygen Generation Assembly (OGA), to be operated on the International Space Station (ISS). The hydrogen sensor ORU is being provided by Makel Engineering, Inc. (MEI) to monitor the oxygen outlet for the presence of hydrogen. The hydrogen sensor ORU is a triple redundant design where each sensor converts raw measurements to actual hydrogen partial pressure that is reported to the OGA system controller. The signal outputs are utilized for system shutdown in the event that the hydrogen concentration in the oxygen outlet line exceeds the specified shutdown limit. Improvements have been made to the Micro-Electro-Mechanical Systems (MEMS) based sensing element, screening, and calibration process to meet OGA operating requirements. Two flight hydrogen sensor ORUs have successfully completed the acceptance test phase. This paper also describes the sensor s performance during acceptance testing, additional tests planned to extend the operational performance calibration cycle, and integration with the OGA system.

MSadoques, George, Jr.↗

Lightweight Fiber Optic Gas Sensor for Monitoring Regenerative Food Production

In this final report, Physical Optics Corporation (POC) describes its development of sensors for oxygen, carbon dioxide, and relative humidity. POC has constructed a phase fluorometer that can detect oxygen over the full concentration range from 0 percent to 100 percent. Phase-based measurements offer distinct advantages, such as immunity to source fluctuation, photobleaching, and leaching. All optics, optoelectronics, power supply, and the printed circuit board are included in a single box; the only external connections to the fluorometer are the optical fiber sensor and a power cord. The indicator-based carbon dioxide sensor is also suitable for short-term and discrete measurements over the concentration range from 0 percent to 100 percent. The optical fiber-based humidity sensor contains a porous core for direct interaction of the light beam with water vapor within fiber pores; the detection range for the humidity sensor is 10 percent to 100 percent, and response time is under five minutes. POC is currently pursuing the commercialization of these oxygen and carbon dioxide sensors for environmental applications.

Schmidlin, Edward↗

Oxygen pressure control for electrolysis cells

Duty cycle of switched, constant current circuit controlled by pressure sensor provides oxygen at a constant pressure from a cell which electrolyzes water, eliminating possibility of cell damage by excessive oxygen demand.

Powell, J. D.↗

X-ray quantification of oxygen groups on diamond surfaces for quantum applications

Abstract Identifying the surface chemistry of diamond materials is increasingly important for device applications, especially quantum sensors. Oxygen-related termination species are widely used because they are naturally abundant, chemically stable, and compatible with stable nitrogen vacancy centres near the diamond surface. Diamond surfaces host a mixture of oxygen-related species, and the precise chemistry and relative coverage of different species can lead to dramatically different electronic properties, with direct consequences for near-surface quantum sensors. However, it is challenging to unambiguously identify the different groups or quantify the relative surface coverage. Here we show that a combination of x-ray absorption and photoelectron spectroscopies can be used to quantitatively identify the coverage of carbonyl functional groups on the { 100 } diamond surface. Using this method we reveal an unexpectedly high fraction of carbonyl groups ( > 9%) on a wide range of sample surfaces. Furthermore, through a combination of ab initio calculations and spectroscopic studies of engineered surfaces, we reveal unexpected complexities in the x-ray spectroscopy of oxygen terminated diamond surfaces. Of particular note, we find the binding energies of carbonyl-related groups on diamond differs significantly from other organic systems, likely resulting in previous misestimation of carbonyl fractions on diamond surfaces.

36 MATERIALS SCIENCE↗

Fluorescence Enhancement in the Solid State by Isolating Perylene Fluorophores in Metal–Organic Frameworks

Polycyclic aromatic hydrocarbons such as perylene, pyrene, and their derivatives are highly emissive fluorophores in solution. Furthermore, the practical applications of these materials in the field of molecular electronic and light emitting devices are often hindered by self-quenching effects due to the formation of non-fluorescent aggregates in concentrated solutions or in the solid state. Herein, we demonstrate that aggregation caused quenching of perylenes can be minimalized by molecular incorporation into metalorganic frameworks (MOFs). This study utilized a stable Zr 6 cluster-based MOF, UiO-67, as a matrix. Linear linkers containing the photo-responsive moieties were designed and incorporated into the parent UiO-67 scaffold through the partially replacement of the non-fluorescent linkers of a similar length, forming mixed-linker MOFs. Here, the average distance between perylene moieties was tuned by changing the linker ratios, thus controlling the fluorescence intensity, emission wavelength, and quantum yield. Molecular modeling was further adopted to correlate the number of isolated perylene linkers within the framework to the ratio between the two linkers, therefore rationalizing the change in the observed fluorescent properties. Taking advantage of the tunable fluorescence, inherent porosity, and high chemical stability of this MOF platform, it was applied as a fluorescent sensor for oxygen detection in the gas phase, a model reaction, showing fast response and good recyclability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗