Search NASA⌕ Search

SEARCH · Search NASA

Results for “Office”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Current Status of Programs and Research within the NASA Orbital Debris Program Office

The NASA Orbital Debris Program Office (ODPO) is the world's longest-standing orbital debris research organization. It supports all aspects of international and US national policy-making related to the orbital environment and to spacecraft life cycle requirements. Representing more than just NASA projects, it is the United States' center of expertise in the field. The office continues to advance research in all aspects of orbital debris, including its measurement, modeling, and risk assessment for both orbital and ground safety concerns. This presentation will highlight current activities and recent progress in all aspects of the ODPO's mission.

Bacon, Jack↗

KSC Integration Office Documentation and Support

This report details the process of document management within the KSC Integration Office throughout my internship in the fall term of the year 2020. During this term, I was mentored by Felix A. Soto-Toro and my main objective was to support the Audit Liaison Representatives (ALR) in their documentation processes. I worked alongside the members of the KSC Integration Office to streamline the auditing process in order to facilitate the interchangement of documents and communication between auditors and our agency. My approach to this situation was to document the events of each audit in a report, which would be updated weekly every Monday following a specific format. As support I was required to gather, organize, and release data relevant to current audits in an online server for ALRs to use across the entire NASA Agency.

Ana C Arvelo Serrano↗

2023 Updates from the NASA Balloon Program Office

This presentation offers an overview of NASA's Balloon Program Office, which is responsible for the design, development, and execution of scientific balloon missions for a variety of scientific disciplines. The paper discusses the history of the program, its current capabilities, and future plans for expanding the scope of its scientific investigations. The paper also provides details on the various types of balloons used by the program, as well as the unique challenges involved in launching and recovering these balloons from remote locations around the world. In addition, the paper highlights some of the significant scientific achievements made possible by the program, including the study of cosmic rays, the search for dark matter, and the exploration of the Earth's atmosphere. Finally, the paper outlines the potential future directions of the program, including the development of larger, longer-duration balloons and the integration of new technologies such as optical communication and autonomous systems. Overall, this paper provides a comprehensive overview of NASA's Balloon Program Office and its ongoing efforts to advance scientific understanding of our world and the universe beyond.

Sarah A Roth↗

Assessing Crew Medical Officer Preparedness for International Space Station Missions

INTRODUCTION Astronaut crew medical officers (CMO) undergo additional, specialized training to provide medical support onboard the International Space Station (ISS). CMO training focuses on utilizing resources on-station and optimizing communication with ground-based expertise to manage both common minor conditions as well as emergency/trauma situations. As NASA moves towards future Artemis and exploration class missions, we sought CMO perspectives on past, present, and future CMO training and medical resourcing to help inform mission planners regarding medical risk mitigation considerations. We present an interview-based qualitative assessment of CMO preparedness for the International Space Station with the aim to help iterate future training flows for Low Earth Orbit, Artemis, and exploration-class missions. METHODS A semi-structured interview tool was developed to assess CMO experience and their recommendations for future mission training considerations. Participants were recruited from former or current US astronauts who were designated as CMO and subsequently flew to the International Space Station. 10 former CMOs took part in the study. Interview transcripts were deidentified and evaluated for qualitative thematic analysis by two independent coders with NVivo Software suite (Lumivero, Denver, CO), and emergent themes were compiled. RESULTS Former CMO crew expressed appropriate preparedness for current ISS medical capabilities and requirements. They identified the role of the CMO as serving as a healthcare extender to ground-based flight surgeons for ISS and other LEO missions. Individuals with prior medical experience were preferred though not felt to be necessary for LEO missions. For exploration class missions with limitations in ground communication, a physician-as-CMO and more rigorous training curricula for both the CMO and astronaut crew were desired. DISCUSSION Former NASA astronaut crew were interviewed to retrospectively assess their preparedness as ISS crew medical officers and hypothesize future medical knowledge, skill, and ability needs. Along with medical operations subject matter expert opinion and advanced probabilistic risk assessment modeling, past CMO experience can help inform future CMO training considerations and responsibilities for future Artemis and exploration class missions.

M A Labarbera↗

The NASA Orbital Debris Program Office - In Service of Space Safety

Since the NASA Orbital Debris Program Office’s (ODPO) founding in 1979 at the Johnson Space Center in Houston, Texas, it has been at the forefront of orbital debris research, modeling, and policy development. The ODPO has worked in collaboration with NASA and other U.S. government missions since the 1980s to mitigate the growth of the orbital debris environment and protect the population of the Earth. Two main products from the ODPO, the Orbital Debris Engineering Model (ORDEM) and the Debris Assessment Software (DAS), are frequently among the top three most-downloaded software packages from the NASA Software Catalog. These products are provided free of charge to the public in furtherance of the goal to ensure that new space missions, in compliance with NASA’s orbital debris mitigation requirements, are developed, operated, and disposed of responsibly. In addition to these external-facing software tools, the ODPO maintains high-fidelity internal tools for reentry simulation (the Object Reentry Survival Analysis Tool, ORSAT), short-term risk assessment for robotic and human spaceflight missions (the Satellite Breakup Risk Assessment Module, SBRAM), among others. Using data from the ORDEM model, as well as using the Meteoroid Environment Model (MEM) developed by the Meteoroid Environment Office (MEO) at NASA’s Marshall Space Flight Center, the Hypervelocity Impact Technology (HVIT) team uses the BUMPER code to assess penetration risk to space vehicles in Earth orbit and beyond. This paper will discuss the services that the ODPO and HVIT provide, from mission concept development through end-of-mission, for NASA-related and commercial missions.

Chris Ostrom↗

Brochure for the DOE Office of Science Workshop on Envisioning Frontiers in AI and Computing for Biological Research

In February of 2025 a joint ASCR/BER workshop was held to identify key transformational research directions for understanding biology using artificial intelligence (AI), digital twins and high-performance (HPC) computational methods to facilitate scientific discovery and innovation in support of the Department of Energy mission. AI technologies offer exciting new groundbreaking methods to analyze large volumes of complex biological data, thereby greatly accelerating the ability to understand, predict, and design biological processes for beneficial purposes. In the laboratory, the bridging of AI-enabled automated experimental technologies, HPC and digital twins will provide potent tools for researchers to explore the fundamental nature of biology and harness its inherent metabolic potential for a variety of beneficial purposes. The focus of this workshop was on how high-performance computational methods can impact this objective by exploring digital twins, foundational models, and data-driven approaches with applications to advance automated laboratory experiments, modeling of complex living systems and engineering new functions into plants and microbial systems relevant to DOE mission. Workshop attendees with expertise in plant science, microbiology, mathematics, computer science, and AI assessed the current state of the science, trends, and AI challenges at the interface of plant and microbial systems biology and computational science to identify opportunities for high-impact research. This collaborative effort capitalized on ASCR's advancements in applied mathematics, computer science, and Exascale systems, and BER's expertise in basic genomics-enabled research on DOE relevant plant and microbial systems. The workshop culminated in four key priority research directions to guide future research and development within DOE Office of Science programs.

59 BASIC BIOLOGICAL SCIENCES↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Assessing modifications to the Abdul-Razzak and Ghan aerosol activation parameterization (version ARG2000) to improve simulated aerosol–cloud radiative effects in the UK Met Office Unified Model (UM version 13.0)

The representation of aerosol activation is a key source of uncertainty in global composition-climate model simulations of aerosol–cloud interactions. The Abdul-Razzak and Ghan (ARG) activation parameterization is used in several global and regional models that employ modal aerosol microphysics schemes. In this study, we investigate the ability of the ARG parameterization to reproduce simulations with a cloud parcel model and find its performance is sensitive to the geometric standard deviations (widths) of the lognormal aerosol modes. We recommend adjustments to three constant parameters in the ARG equations, which improve the performance of the parameterization for small mode widths and its ability to simulate activation in polluted conditions. For the accumulation mode width of 1.4 used in the Met Office Unified Model (UM), the modifications decrease the mean bias in the activated fraction of aerosols compared to a cloud parcel model from −6.6 % to +1.2 %. We implemented the improvements in the UM and compared simulated global cloud droplet concentrations with satellite observations. The simulated cloud radiative effect changes by −1.43 W m −2 (6 %) and aerosol indirect radiative forcing over the industrial period changes by −0.10 W m −2 (10 %).

Ghosh, Pratapaditya [Carnegie Mellon University, P↗

The JPL Resource Allocation Planning and Scheduling Office (RAPSO) process

The Jet Propulsion Laboratory's Resource Allocation Planning and Scheduling Office is chartered to divide the limited amount of tracking hours of the Deep Space Network amongst the various missions in as equitable allotment as can be achieved. To best deal with this division of assets and time, an interactive process has evolved that promotes discussion with agreement by consensus between all of the customers that use the Deep Space Network (DSN). Aided by a suite of tools, the task of division of asset time is then performed in three stages of granularity. Using this approach, DSN loads are either forecasted or scheduled throughout a moving 10-year window.

RAPSO Resource Allocation Planning and Scheduling ↗

Experimentally-Derived Bidirectional Reflectance Distribution Function Data in Support of the Orbital Debris Program Office

The NASA Orbital Debris Program Office (ODPO) has used various optical assets to acquire photometric data of Earth-orbiting objects to define the orbital debris environment. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA Johnson Space Center emulates illumination conditions seen in space by using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. One of the OMC goals is to improve the size calculation used for optical data by developing an optical-based Size Estimation Model. The current size estimation requires applying a Lambertian phase function, a set albedo value, and range to the observed magnitude. The first step to improving the sampled brightness of laboratory targets is to remove aspect-angle dependencies. Then, the volume of possible object viewing angles is sampled at 21 combinations of azimuth and zenith angles for each solar phase angle. Finally, the acquired images are input into an image processing program that generates approximations for the object’s Bidirectional Reflectance Distribution Function (BRDF) and phase function. The BRDF is a radiometric concept that identifies an object’s material composition by matching a BRDF approximated with photometric data collected by ground-based telescopes with a BRDF generated experimentally from a known object in the laboratory. This paper discusses the validation of experimental BRDF and phase function approximations produced in the OMC and how the findings will be incorporated into ODPO models. A Lambertian sphere is imaged and the subsequent experimental functions are scrutinized to confirm that they correspond to an object that has an isotropic luminance. With the image processing algorithm validated, test objects with varying optical properties are then imaged to confirm that the produced photometric functions are both unique and repeatable. Once the validation is complete, the OMC will be used to evaluate a subset of fragments from a hypervelocity impact test of a mock-up satellite and assess the appropriate phase function and size estimates using BRDF measurements for a large volume of targets composed of various shapes, sizes, and materials.

Orbital Debris Program Office (ODPO)↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons Learned From the Planning of Recent Wind Energy Technologies Office Field Campaigns

The U.S. Department of Energy (DOE) Wind Energy Technology Office (WETO) has funded several wind-energy-focused field campaigns in recent years. While essential to advance our understanding of the interactions between atmosphere and wind turbines, the planning of such campaigns has presented several challenges to the institutions involved in these efforts. In this document, we focus on the planning phase of the field campaigns and summarize the lessons learned from the recent AWAKEN, RAAW, and WFIP-3 field projects. We cover a variety of aspects to offer a proposed methodological pipeline that we recommend is followed when future similar endeavors are planned.

17 WIND ENERGY↗

Countering Weapons of Mass Destruction Office (CWMD) Data Categorization Study: Chemical, Biological, Radiological, and Nuclear (CBRN) Detection Device Data

Pacific Northwest National Laboratory (PNNL) seeks to address critical questions related to chemical, biological, radiological, and nuclear (CBRN) detection devices. This research aims to enhance the security and understanding of these devices by investigating various aspects of their identification, communication, and functionality. The primary focus is on network security, malware detection, device identification, and intelligence gathering. CBRN data can be categorized in various ways depending on the purpose of CBRN detection devices and the specific context of the applications for analysis. Criteria that can be used to assist in this effort include but are not limited to data type, data protocol, source/destination, application, time, security, and content. This study will inform additional paths for data classification, data profiling, data mapping, and data modeling. This will help the Countering Weapons of Mass Destruction Office (CWMD) better understand their data and make informed decisions based on the insights gained from this study and their application. The CBRN Data Categorization study will include the identification of 5–10 different CBRN detection devices with unique characteristics for assessing and analyzing the data that is being produced by and transmitted from these devices.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗