Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

EUV Diagnostics of Optically Thick Plasmas Using the 304 Å Channel

A fundamental limitation of current EUV diagnostic techniques is the need to neglect the He II emission contribution in the 304Å channel. This limits our ability to use strong observations available to us and increases uncertainties in the measurements made. A new EUV diagnostic technique is introduced that accounts for absorption as well as emission contributions from emitting channels such as 304 Å. This new technique can be equally applied to emitting and non-emitting channels, paving the way for more realistic discussion of the heating and energetics of transient plasmas using a wider range of observations. The diagnostic technique is used to compute the dynamics and energetics of a filament eruption observed in the high-cadence SDO/AIA and the associated ICME is observed by ACE/SWICS. The analysis gives us robust measurements of filament dynamics, energetics and its ionization history in the low solar corona. A comparison of these results with results calculated with techniques where He II emission in 304 Å is not considered allowed us to quantify the contribution from emission and comment on the robustness of our method.

EUV↗

Shock-Wave/Boundary-Layer Interaction (SWBLI) Experiments in the Presence of Transition-to-Turbulence on a Flat Plate Model in the NASA LaRC 31-Inch Mach 10 Air Tunnel

Historically, there have been a limited number of studies involving Transitional Shock-Wave/Boundary-Layer Interactions (XSWBLI) in hypersonic flows, the majority of which have been performed at Mach Numbers of 7.5 and below. Additionally, there have been even fewer such experiments which incorporate non-intrusive and optical diagnostics. NASA Langley Research Center (NASA LaRC), in collaboration with The University of Texas at San Antonio (UTSA) and The University of Tennessee Space Institute (UTSI), is currently planning and preparing for a series of experimental aerodynamic tests using the NASA LaRC 31-inch Mach 10 Air Tunnel. The experiments will primarily focus on studying the dynamics of Shock-Wave/Boundary-Layer Interactions (SWBLI) in the presence of transition (XSWBLI) and turbulence (SWTBLI) on a large, flat plate model at a freestream Mach number of 10. Besides continued interest in understanding the flow at high Mach numbers, executing such tests at Mach 10 avoids some known concerns and will aid in solving new problems. XSWBLI are a highly unsteady phenomena and the generation of XSWBLI at lower Mach numbers can prove to be a significant challenge. This concern will be somewhat mitigated in the Mach 10 flow, as boundary layers become increasingly stabilized, but some difficulty in achieving transition is still expected. Modelling SWBLI in the presence of transitional and turbulent boundary layers has also proven to be difficult, so a high-Mach number experiment which applies non-intrusive and optical diagnostics will aid in solving a unique problem as well as advancing the understanding and characterization of an aerodynamic surface at Mach 10.The NASA LaRC 31-inch Wind Tunnel incorporates a test section having a cross-section of 31-inches × 31-inches and provides optical access to the test section via three (3) ultra-violet (UV) transmitting windows on the top, side, and bottom. The Mach 10 operating conditions will consist of pressures (P0) ranging from 2.4 to 10MPa (348 to 1,450 psi) at a temperature (T0) of 1,000 K (1,800 °R). The NASA LaRC 31-inch wind tunnel will deliver 1-minute blow-down runs, of which 30-45 seconds will be consumed to reach the aforementioned test conditions. The pump down time between runs will be approximately 45-60 minutes, which will provide for 6-10 test runs per day over the course of a weeklong entry. The proposed flat plate model will be constructed of stainless steel with geometry consisting of a10-inch × 30-inch upper surface and a 2-inch thickness. The model will be designed to support multiple leading-edge inserts in order to examine blunt, round, and sharp leading edges at Mach 10. Adjustments will be made to manage boundary layer thickness as well as the strength and size of the shock interaction region for each test. Measurements and diagnostics will be performed though high-speed Schlieren, on-body high-speed pressure transducers, IR thermography, and oil flow visualization. Hypersonic vehicle applications have and will continue to emerge at the forefront of aerospace. The NASA-UTSA-UTSI team realizes the value of characterizing SWBLI, XSWBLI, and SWTBLI behaviors well beyond single-digit hypersonic Mach numbers. As hypersonic vehicle speed capabilities continue to increase, measurement and diagnostic methods for Mach numbers of 10 and beyond will provide the foundation for a firm understanding of flow field behavior which will directly influence the advancement of technologies towards the design and manufacturing of high-speed aerodynamic surfaces, controls, thermal protection systems, acoustic treatments, and structural components. The use of non-intrusive and optical diagnostic methods in such experimentation is pivotal in developing the visualization and empirical data necessary to advance the aforementioned technology areas.

Shockwave/Boundary-Layer Interactions↗

Challenges to Laser-Based Imaging Techniques in Gas Turbine Combustor Systems for Aerospace Applications

Increasingly severe constraints on emissions, noise and fuel efficiency must be met by the next generation of commercial aircraft powerplants. At NASA Lewis Research Center (LeRC) a cooperative research effort with industry is underway to design and test combustors that will meet these requirements. To accomplish these tasks, it is necessary to gain both a detailed understanding of the combustion processes and a precise knowledge of combustor and combustor sub-component performance at close to actual conditions. To that end, researchers at LeRC are engaged in a comprehensive diagnostic investigation of high pressure reacting flowfields that duplicate conditions expected within the actual engine combustors. Unique, optically accessible flame-tubes and sector rig combustors, designed especially for these tests. afford the opportunity to probe these flowfields with the most advanced, laser-based optical diagnostic techniques. However, these same techniques, tested and proven on comparatively simple bench-top gaseous flame burners, encounter numerous restrictions and challenges when applied in these facilities. These include high pressures and temperatures, large flow rates, liquid fuels, remote testing, and carbon or other material deposits on combustor windows. Results are shown that document the success and versatility of these nonintrusive optical diagnostics despite the challenges to their implementation in realistic systems.

Locke, Randy J.↗

Optical emission diagnostics of electron cyclotron resonance and glow discharge plasmas for a-Si:H and a-SiC:H film depositions

It is demonstrated that the steady-state and kinetic characteristics of ECR (electron cyclotron resonance) and RF glow discharge plasmas can be readily monitored by OES (optical emission spectroscopy) in real time during a-Si:H and a-SiC:H film depositions using an OMA detection system. The ECR and RF glow discharge plasmas used for a-Si:H and a-SiC:H film depositions were studied by monitoring the emission of SiH(asterisk), H(asterisk), H(asterisk)2, and CH(asterisk) excited states. The OES of the ECR plasma shows a strong emission at 434 nm from H(asterisk), which is not detectable in the glow discharge plasma. Steady-state OES studies have established preliminary correlations between SiH(asterisk) and CH(asterisk) emission intensities and the film deposition rate. Transient OES spectra of SiH4 and CH4 plasmas have shown different kinetics in SiH(asterisk) and CH(asterisk) emission intensities. Transient studies of the SiH(asterisk) emission intensity have indicated that additional mechanisms for producing the SiH(asterisk) species become evident in hydrogen-diluted silane plasmas.

Yang, C. L.↗

Nonintrusive Diagnostic Strategies for Arcjet Stream Characterization

In the previous lecture, the issues related to arcjet flow modeling were introduced, and the limitations of conventional instrumentation in addressing these issues were discussed. The general level of understanding of the arcjet flows was seen to preclude the use of arcjets as aerothermodynamic test facilities beyond the current role in aerothermal material testing, despite their long test duration capability. In this section, the focus will be on new developments in spectroscopic instrumentation and techniques that can be brought to bear on the fundamental problem of arcjet stream characterization. Although a wide selection of arcjet facilities were introduced in the previous section, the discussion of nonintrusive diagnostic instrumentation will be restricted to the large-scale, segmented, constricted-arc heater facilities that are most widely used in thermal protection material testing for aerospace applications. After a brief review of the important features of arcjet flows, the topic of nonintrusive, optical diagnostics is introduced with a discussion of some of the basic aspects of radiative transitions. The lecture is then organized into two sections covering emission measurements and laser-induced fluorescence measurements. Emission measurements are presented next for different regions of arcjet flows, while the fluorescence measurements are presented for the free stream region only. Summaries are given for each of the two main sections, and observations on arcjet characterization by optical diagnostics in general are given at the end.

Fletcher, Douglas G.↗

Free Surface Phenomena Under Low- and Zero-Gravity Conditions

In a low- or zero-gravity environment the free surface of a liquid can behave in striking, unexpected ways. For example, in a partially filled container, a free surface that is well behaved under terrestrial conditions can rise to an arbitrarily large height or even fail to exist when gravity is absent. An answer is sought to the central mathematical questions: Under what conditions can free surfaces exist and what are their properties? -- and experimental questions of what means can be devised to observe and to measure the surfaces quantitatively. Current activity focuses on material selection and the design of optical diagnostic methods for in-space experiments. These experiments will test mathematical predictions of discontinuous transition from existence to nonexistence of capillary free surfaces in certain geometric configurations under zero gravity conditions. Liquids and container materials suitable for achieving the required contact-angle range and optical properties are being investigated, as well as the effects of contaminants and fluid motion on contact angle. The optical diagnostic technique investigation concerns laser-induced fluorescence, including emphasis on data on acquisition, sources and detectors, reliability, data management, and computer control.

Concus, P.↗

Non-contact temperature measurements in support of microgravity combustion experiments

Recent conceptual advances in the understanding of combustion science fundamentals in the context of microgravity processes and phenomenology have resulted in an increased demand for diagnostic systems of greater sophistication. Owing primarily to the severe operational constraints that accompany the space flight environment, measurement systems to date remain fairly primative in nature. Qualitative pictures provided by photographic recording media comprise the majority of the existing data, the remainder consisting of the output of conventional transducers, such as thermocouples, hot wires, and pressure transducers. The absence of the rather strong influence of buoyant convection renders microgravity combustion phenomena more fragile than their 1-G counterparts. The emphasis was placed on nonperturbing optical diagnostics. Other factors such as limited supplies of expendable reactants, and periods of microgravity time of sufficient duration, coupled with more fundamental questions regarding inherent length and time scales and reproducibility have favored multipoint or multidimensional techniques. While the development of optical diagnostics for application to combustion science is an extremely active area at present, the peculiarities of space flight hardware severely restrict the feasibility of implementing the majority of techniques which are being utilized in terrestrial applications. The additional requirements for system reliability and operational simplicity have tended to promote somewhat less commonly emphasized techniques such as refractive index mapping and molecular Rayleigh scattering, which are briefly discussed.

Greenberg, Paul S.↗

Exploring Interferometry Diagnostics for Optical Stochastic Cooling at FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will precede the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling technique in accelerators. Along with the assembly and use of an interferometer to provide diagnostics and optimization to OSC systems. The interferometer can allow for the observation and analysis of fringe patterns from a recreated simpler version in the laser room. By leveraging interferometric techniques, OSC can achieve higher efficiency, verification, stability and performance.

Teriba, Folashade↗

Optical Flow Diagnostics of Counter Fluidization of Gravity-Driven Moving Packed Bed for a CSP Receiver Section Featuring Staggered Array of Cylindrical Pins

Particle fluidized beds have the potential to improve the efficiency of heat transfer in concentrated solar receiver furnace for use in next generation concentrated solar power (CSP) plants. This study presents an experimental investigation on the flow characterization of vertically downward moving packed bed with counter fluidization through an array of jets. To control the bubble size and its distribution in the bubbling fluidized bed, an array of cylindrical pin fins was arranged uniformly across the test article. The flow visualization was performed on the surface of transparent glass coated with electrically conductive materials for electrostatic dissipation purposes. The image acquisition was carried out via high-speed camera at a frequency of ~ 1kHz. The acquired images were analyzed in pairs with the help of a modern optical flow algorithm capable of calculating the movement of dense particle flow in the fluidized bed by tracking the light intensity of each predefined window of the frames. A comparison of fluidized beds with plane and pin-finned channels revealed distinct bubble behavior. Pin-finned channels were found to produce a larger number of small-sized bubbles, while plane channels generated fewer but larger bubbles at any given instant. The presence of pin fins was observed to reduce bubble size by preventing bubble merging and splitting larger bubbles when they encountered a pin.

concentrating solar power↗

Local Neutral Density and Plasma Parameter Measurements in a Hollow Cathode Plume

In order to understand the cathode and keeper wear observed during the Extended Life Test (ELT) of the DS1 flight spare NSTAR thruster and provide benchmarking data for a 2D cathode/cathode-plume model, a basic understanding of the plasma and neutral gas parameters in the cathode orifice and keeper region of the cathode plume must be obtained. The JPL cathode facility is instrumented with an array of Langmuir probe diagnostics along with an optical diagnostic to measure line intensity of xenon neutrals. In order to make direct comparisons with the present model, a flat plate anode arrangement was installed for these tests. Neutral density is deduced from the scanning probe data of the plasma parameters and the measured xenon line intensity in the optical regime. The Langmuir probes are scanned both axially, out to 7.0 cm downstream of the keeper, and radially to obtain 2D profile of the plasma parameters. The optical fiber is housed in a collimating stainless steel tube, and is scanned to view across the cathode plume along cuts in front of the keeper with a resolution of 1.5 mm. The radial intensities are unfolded using the Abel inversion technique that produces radial profiles of local neutral density. In this paper, detailed measurements of the plasma parameters and the local neutral densities will be presented in the cathode/keeper plume region for a 1.5 cm diameter NEXIS cathode at 25A of discharge current at several different strengths of applied magnetic field.

Plasma density↗

Comparing Global Spray Combustion Characteristics and Local Shot-to-Shot Variations in a Reacting n -Heptane Spray

In support of efforts to develop improved models of turbulent spray behavior and combustion in diesel engines, experimental data and analysis must be obtained for guidance and validation. For Reynolds-averaged Navier–Stokes (RANS)-based Computational fluid dynamics (CFD) modeling approaches, representative ensemble average experimental results are important. For high-fidelity models such as large eddy simulations (LES)-based CFD, precise individual experimental results are desirable. However, making comparisons between a given experiment and LES is a challenge since local parameters cannot be directly compared. In this work, an optically accessible constant pressure flow rig (CPFR) is utilized to acquire diesel-like fuel injection and reaction behavior simultaneously with three optical diagnostic techniques: rainbow Schlieren deflectometry (RSD), OH* chemiluminescence (OH*), and two-color pyrometry (2CP). The CPFR allows a large number of repeated injection experiments to be performed for statistical analysis and convergence using ensemble-averaging techniques, while maintaining highly repeatable test conditions. Even for stable test conditions, variations in local turbulent fuel–air mixing introduce variability, which manifests as significant differences in OH* and 2CP results. Experimental measurements of characteristic parameters including liquid and vapor jet penetration, liftoff length, soot temperature and concentration, and turbulent flame speed, along with the shot-to-shot variability of each dataset, are presented and discussed. Finally, a statistical method is utilized to analyze the extent of this variability, and to identify superlative injections within the dataset for discussion and analysis of shot-to-shot variations.

42 ENGINEERING↗

Proposed Longitudinal Profile Diagnostics for Optical Stochastic Cooling of Stored Electrons in the IOTA Ring

One of the predicted signatures of successful optical stochastic cooling (OSC) in the Fermilab Integrable Optics Test Accelerator (IOTA) ring is reduction of the bunch length. The IOTA OSC experiment is designed for a low nominal beam current (~0.1 microAmps of 100-MeV electrons) to reduce intrabeam scattering (IBS), and during cooling, OSC is expected to reduce the bunch length from ~200 ps to ~130 ps*. These equilibrium bunch lengths can be measured using a streak camera and the optical synchrotron radiation (OSR) generated in a ring dipole by the circulating beam. A similar measurement was previously performed at the Advanced Photon Source with a Hamamatsu C5680 synchroscan streak camera operating at 117.3 MHz**. In this case, synchronous summing of OSR resulted in a bunch length measurement of 276 ± 30 ps using only 57 electrons circulating at 425 MeV. At IOTA, an existing streak camera has been modified to operate at the 11th harmonic of the ring’s revolution frequency of 7.50 MHz and has been installed on an OSR port in support of the OSC experiments. The integrated system will have sufficient sensitivity and resolution for measuring the evolution and equilibrium values of the bunch length during OSC experiments.

Lumpkin, Alex H.↗

EXPLORING INTERFEROMETRY DIAGNOSTICS FOR OPTICAL STOCHASTIC COOLING AT FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will advance the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling techniques in accelerators. The goal was to build and characterize a Mach-Zehnder Interferometer (MZI) in the FAST laser lab using known glass plates thickness which will allow future measurements of unknown phase change due to nonlinear amplification processes.

Teriba, Folashade↗

A Compact, Tunable Near-UV Source for Quantitative Microgravity Combustion Diagnostics

There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.

Peterson, K. A.↗

Optical Investigation of a Partial Fuel Stratification Strategy to Stabilize Overall Lean Operation of a DISI Engine Fueled with Gasoline and E30

This paper offers new insights into a partial fuel stratification (PFS) combustion strategy that has proven to be effective at stabilizing overall lean combustion in direct injection spark ignition engines. To this aim, high spatial and temporal resolution optical diagnostics were applied in an optically accessible engine working in PFS mode for two fuels and two different durations of pilot injection at the time of spark: 210 µs and 330 µs for E30 (gasoline blended with ethanol by 30% volume fraction) and gasoline, respectively. In both conditions, early injections during the intake stroke were used to generate a well-mixed lean background. The results were compared to rich, stoichiometric and lean well-mixed combustion with different spark timings. In the PFS combustion process, it was possible to detect a non-spherical and highly wrinkled blue flame, coupled with yellow diffusive flames due to the combustion of rich zones near the spark plug. The initial flame spread for both PFS cases was faster compared to any of the well-mixed cases (lean, stoichiometric and rich), suggesting that the flame propagation for PFS is enhanced by both enrichment and enhanced local turbulence caused by the pilot injection. Different spray evolutions for the two pilot injection durations were found to strongly influence the flame kernel inception and propagation. PFS with pilot durations of 210 µs and 330 µs showed some differences in terms of shapes of the flame front and in terms of extension of diffusive flames. Yet, both cases were highly repeatable.

33 ADVANCED PROPULSION SYSTEMS↗