Integrated Liquid/Steam Multiphase Flow Sensors for Geothermal Applications
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Periodic optical structures can control the flow of light, which has facilitated applications in optical fibers, laser cavities, and biochemical sensors. The first Brillouin zone (BZ) in reciprocal space can describe all the electromagnetic fields localized inside a photonic lattice. However, photonic lattices also exhibit radiative losses from light scattering, but the radiated fields are not captured by the first BZ. In a two-dimensional lattice, the in-plane wavevectors of photonic modes are limited by the so-called light cone, which depicts free-photon dispersion relations in the surrounding medium. Here we show that projection of the light cone on extended BZs provides a geometric method to observe radiated electromagnetic fields of photonic lattice modes. We developed a coupled dipole radiation theory to reveal how lattice geometry and dipole orientation affect the angular distributions of the radiated fields. Using dye molecules as local dipole emitters to excite and probe the optical modes, we experimentally identified high-order BZ edges through directional, in-plane lasing emission.
The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.
Top-down measurements of catechol films show orthogonal energy flow via redox and optical modalities. These molecular electronic properties enable communication through both short-range redox modalities and long-range electromagnetic modalities.
Optical delay lines control the flow of light in time, introducing phase and group delays for engineering interferences and ultrashort pulses. Photonic integration of such optical delay lines is essential for chip-scale lightwave signal processing and pulse control. However, typical photonic delay lines based on long spiral waveguides require extensively large chip footprints, ranging from mm 2 to cm 2 scales. Here we present a scalable, high-density integrated delay line using a skin-depth engineered subwavelength grating waveguide, i.e., an extreme skin-depth (eskid) waveguide. The eskid waveguide suppresses the crosstalk between closely spaced waveguides, significantly saving the chip footprint area. Our eskid-based photonic delay line is easily scalable by increasing the number of turns and should improve the photonic chip integration density.
Structured lights, including beams carrying spin and orbital angular momenta, radially and azimuthally polarized vector beams, as well as spatiotemporal optical vortices, have attracted significant interest due to their unique amplitude, phase front, polarization, and temporal structures, enabling a variety of applications in optical and quantum communications, micromanipulation, and super-resolution imaging. In parallel, structured optical materials, metamaterials, and metasurfaces consisting of engineered unit cells—meta-atoms, opened new avenues for manipulating the flow of light and optical sensing. While several studies explored structured light effects on the individual meta-atoms, their shapes are largely limited to simple spherical geometries. However, the synergy of the structured light and complex-shaped meta-atoms has not been fully explored. Here, in this paper, the role of the helical wavefront of Laguerre–Gaussian beams in the excitation and suppression of higher-order resonant modes inside all-dielectric meta-atoms of various shapes, aspect ratios, and orientations, is demonstrated and the excitation of various multipolar moments that are not accessible via unstructured light illumination is predicted. The presented study elucidates the role of the complex phase distribution of the incident light in shape-dependent resonant scattering, which is of utmost importance in a wide spectrum of applications ranging from remote sensing to spectroscopy.
Detection methods that do not require nucleic acid amplification are advantageous for viral diagnostics due to their rapid results. These platforms could provide information for both accurate diagnoses and pandemic surveillance. Influenza virus is prone to pandemic-inducing genetic mutations, so there is a need to apply these detection platforms to influenza diagnostics. Here, we analyzed the Fast Evaluation of Viral Emerging Risks (FEVER) pipeline on ultrasensitive detection platforms, including a waveguide-based optical biosensor and a flow cytometry bead-based assay. The pipeline was also evaluated in silico for sequence coverage in comparison to the U.S. Centers for Disease Control and Prevention’s (CDC) influenza A and B diagnostic assays. The influenza FEVER probe design had a higher tolerance for mismatched bases than the CDC’s probes, and the FEVER probes altogether had a higher detection rate for influenza isolate sequences from GenBank. When formatted for use as molecular beacons, the FEVER probes detected influenza RNA as low as 50 nM on the waveguide-based optical biosensor and 1 nM on the flow cytometer. In addition to molecular beacons, which have an inherently high background signal we also developed an exonuclease selection method that could detect 500 pM of RNA. The combination of high-coverage probes developed using the FEVER pipeline coupled with ultrasensitive optical biosensors is a promising approach for future influenza diagnostic and biosurveillance applications.
Hypersonic flows of magnetized plasmas naturally produce strong shocks when obstructions or self‐interactions (flow collisions) occur. Such complex flows occur in a wide variety of HEDP settings such as Z‐pinches and laser driven implosion experiments that include magnetic fields via explosive Helmholtz coils (MIFEDS) When thermal energy behind the shocks can be lost to optically thin radiation, the flow dynamics becomes even more complex, admitting a range of new instabilities such as the Nonlinear Thin Shell Instability (NTSI). Because of their inherent non‐ linearity, multi‐dimensionality and time‐dependence (i.e. turbulence), the ability to articulate the underlying physics of colliding hypersonic magnetized flows represents a significant frontier in HEDP studies. The addition of radiative cooling to these flows propels the study even further into the domain of extreme plasma physics. Exploration of these forms of HED plasmas is of interest to basic plasma physics as well as of interest for their application to Inertial Confinement Fusion.
A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.
Thermal barrier coatings (TBC) applied to pistons have been a recently renewed research topic in the field of internal combustion engines. Single cylinder testing of a conventional C15™ Tier 4 final pro-duction steel piston and a TBC coated piston showed that the Yttrium stabilized Zirconia (YSZ) TBC did not significantly alter engine performance, with the TBC piston having slower combustion rates and higher criteria emissions. For deeper understanding, research continued by studying 3D-piston sections optically in a constant pressure vessel using photodiodes, four high-speed cameras (natural luminosity, CH*, and OH*), and visualization of the flame from two orthogonal directions. Particle Im-aging Velocimetry (PIV) algorithms were adapted to perform Combustion Imaging Velocimetry (CIV) to aid in quantification of the observed visual combustion flow field differences. The optical work showed that the TBC piston flame development is slower, spatially different, with lower mixing energy for the TBC variant. Geometric profiles of engine pistons and optical vessel 3D-piston sections were measured using a Coordinate Measurement Machine (CMM), and surface roughness was measured with a stylus surface profilometer. CMM results showed that the TBC piston bowl had reasonable macroscopic accuracy, but the rim had a larger radius with less reentrancy. A discussion of the results and analyses in relation to future TBC effort and direction concludes the work.
Here, we present the first local, quantitative measurements of ion current filamentation and magnetic field amplification in interpenetrating plasmas, characterizing the dynamics of the ion Weibel instability. The interaction of a pair of laser-generated, counterpropagating, collisionless, supersonic plasma flows is probed using optical Thomson scattering (TS). Analysis of the TS ion-feature revealed anticorrelated modulations in the density of the two ion streams at the spatial scale of the ion skin depth c/ω pi = 120 μm, and a correlated modulation in the plasma current. The inferred current profile implies a magnetic field amplitude ~30 ± 6 T , corresponding to ~1% of the flow kinetic energy, indicating that magnetic trapping is the dominant saturation mechanism.
Accurate representation of atmospheric aerosol properties is a long-standing problem in atmospheric research. Modern pilotless aerial systems provide a new platform for atmospheric in situ measurement. However, small airborne platforms require miniaturized instrumentation due to apparent size, power, and weight limitations. A Portable Optical Particle Spectrometer (POPS) is an emerged instrument to measure ambient aerosol size distribution with high time and size resolution, designed for deployment on a small unmanned aerial system (UAS) or tethered balloon system (TBS) platforms. This study evaluates the performance of a POPS with an upgraded laser heater and additional temperature sensors in the aerosol pathway. POPS maintains its performance under different environmental conditions as long as the laser temperature remains above 25 °C and the aerosol flow temperature inside the optical chamber is 15 °C higher than the ambient temperature. The comparison between POPS and an Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) suggests that the coincidence error is less than 25% when the number concentration is less than 4000 cm –3 . The size distributions measured by both of them remained unaffected up to 15,000 cm –3 . While both instruments’ sizing accuracy is affected by the aerosol chemical composition and morphology, the influence is more profound on the POPS.
Flows and rotation, particularly E×B rotation, are critical to improving plasma performance, and waves are a primary tool of plasma control. Thus, it is paramount to understand under what conditions waves can drive E×B flows in plasmas. In this didactic review, an invited paper accompanying the 2023 Marshall N. Rosenbluth Doctoral Thesis Award, this question is answered in the context of momentum-conserving quasilinear theory. There are two primary frameworks for momentum-conserving quasilinear theories that can handle both resonant and nonresonant particles: Eulerian averaging theories and oscillation-center Hamiltonian theories. There are also two different paradigmatic wave problems: plane-wave initial value problems, and steady-state boundary value problems. Here, it is shown that each of these frameworks “naturally” works better with a different problem type. By using these theories, one finds a great difference in the behavior of time- vs space-dependent waves. A time-evolving plane wave can only drive flow if the electromagnetic momentum of the wave, given by the Poynting flux, changes. This result precludes flow drive by any planar electrostatic wave. In contrast, a steady-state spatially evolving wave can drive flow whenever there is divergence in the flux of Minkowski momentum, a completely different physical quantity. This review aims to provide a high-level, intuitive understanding of the very different behaviors observed for these two types of problem.
Plasma-based ambient desorption/ionization (ADI) sources for mass spectrometry (MS) often use helium as the primary discharge gas due to the large reaction cross section of excited helium species with atmospheric gases, which ultimately leads to efficient reagent-ion formation. However, some studies have shown that mixed-gas plasmas provide unique advantages. For instance, our group showed that a helium-oxygen flowing atmospheric-pressure afterglow (He:O 2 -FAPA) source yielded enhanced ion signals for small polar analytes, but compounds with aromatic rings underwent chemical modification to produce pyrylium species. Here, it is shown that the addition of H 2 to the helium FAPA gas significantly decreased the reagent-ion signals, but analyte-ion signal was not affected to the same degree. In addition, mass spectra obtained with He:H 2 -FAPA were chemically cleaner with fewer ions stemming from analyte species and produced less oxidation of analytes. Addition of nitrogen increased the abundance of negative reagent ions (e.g., NO 2 - and NO 3 - ) which led to enhanced ion signal for RDX. To better understand these unique advantages of a mixed-gas FAPA, the impact of molecular-gas (O 2 , N 2 , or H 2 ) addition on the optical-emission spectra from the discharge was also measured. Spatially resolved emission was obtained from the anode- and negative-glow regions. In general, addition of small fractions (~0.1%) of molecular gases decreased helium and OH emission intensities. Atomic oxygen and hydrogen emission increased with the addition of O 2 and H 2 , respectively. Furthermore, emission characteristics of N 2 , N 2 + , and NO with respect to molecular gas composition on He-FAPA were measured. Finally, fundamental plasma parameters, such as OH rotational temperature (T rot ), were also calculated for these mixed-gas systems.
Observables from nuclear and high-energy experiments can be degraded by detector performance and/or methodology in extracting the observables, such as of the final-state characteristics of heavy-ion collisions in relation to a coarsely estimated reaction-plane direction. We propose the use of deblurring methods, such as in optics, to correct for observable degradation. Our main focus is the restoration of triple-differential particle distributions in heavy-ion collisions. We demonstrate that these could be extracted from collision measurements following the Richardson-Lucy deblurring method from optics. We illustrate basic features of the restoration methodology in a schematic model assuming either ideal or more realistic particle detection. Here, the inferred three-dimensional (3D) distributions for collisions may be easier to interpret in terms of collision dynamics and sought properties of bulk matter than the currently employed Fourier coefficients, that combine information from different azimuthal angles relative to the reaction plane.
This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.
Metastable He$_{2}^{*}$ excimer molecules have been utilized as tracer particles of the normal component in superfluid $^4$He (He II) which can be imaged via laser-induced fluorescence. These excimer molecules form tiny bubbles in He II and can bind to quantized vortices at sufficiently low temperatures, thereby allowing for direct visualization of vortex dynamics in an inviscid superfluid. However, the $a^{3}\Sigma^+_{u}$${\rightarrow}$$c^{3}\Sigma^+_{g}$ optical absorption line, which is responsible for the fluorescence imaging of the He$_{2}^{*}$ molecules, is controlled by fluctuations on the bubble shape, and its exact line profile is not known at low temperatures. In this paper, we present a bubble model for evaluating the surface fluctuation eigenmodes of the excimers in He II. The line profile of the $a^{3}\Sigma^+_{u}{\rightarrow}c^{3}\Sigma^+_{g}$ transition is calculated at different temperatures by considering both the zero-point and thermal fluctuations on the bubble shape. We show that, as the temperature drops from 2~K to 20 mK, the peak absorption strength is enhanced by a factor of about five, accompanying a blueshift of the peak location by about 2 nm. A double-peak line profile due to the rotational levels of the molecular core can be resolved. This bubble model also allows us to evaluate the stiffness of the He$_{2}^{*}$ bubbles and hence their diffusion constant in He II due to scattering off thermal phonons. Our results will aid the design of future experiments on imaging quantized vortices in He II using He$_{2}^{*}$ tracers.
SAND2022-3463 O This code is intended to accompany the journal manuscript, “Sub-resolution modeling of the apparent mass loss in quantitative broadband X-ray radiography." The manuscript covers in detail how to improve the quantitative mass distribution measurements made for optical diagnostics of multiphase flows. The code contains four separate script files in MATLAB format to support the objective of improving mass measurements. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.