Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ARQUIN: Architectures for Multinode Superconducting Quantum Computers

Many proposals to scale quantum technology rely on modular or distributed designs wherein individual quantum processors, called nodes, are linked together to form one large multinode quantum computer (MNQC). One scalable method to construct an MNQC is using superconducting quantum systems with optical interconnects. However, internode gates in these systems may be two to three orders of magnitude noisier and slower than local operations. Surmounting the limitations of internode gates will require improvements in entanglement generation, use of entanglement distillation, and optimized software and compilers. Still, it remains unclear what performance is possible with current hardware and what performance algorithms require. In this article, we employ a systems analysis approach to quantify overall MNQC performance in terms of hardware models of internode links, entanglement distillation, and local architecture. We show how to navigate tradeoffs in entanglement generation and distillation in the context of algorithm performance, lay out how compilers and software should balance between local and internode gates, and discuss when noisy quantum internode links have an advantage over purely classical links. Here, we find that a factor of 10–100× better link performance is required and introduce a research roadmap for the co-design of hardware and software towards the realization of early MNQCs. While we focus on superconducting devices with optical interconnects, our approach is general across MNQC implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Systems and methods for optical measurement of cross-wind

Various technologies pertaining to optical measurement of cross-wind are described herein. A beam of light is emitted along a trajectory through a shooting space from a location of a shooter to a target using a laser. The beam is reflected by the target, and the beam is received at two optical detectors. Due to changes in the index of refraction of air along the path of the beam, an envelope signal atmospherically encoded on the beam is received at each of the two apertures at different times. A signal analyzer receives a signal from each of the detectors and outputs data indicative of an average speed of the cross-wind along the trajectory in the shooting space based upon a time delay between the signals.

Bagwell, Brett↗

The Radical Atom: Mechanosynthetic 3D Printing of an Atomically Precise SPM Tip

This research effort sought to overcome current limitations in scanning probe-based atomic manipulation to enable atomically precise manufacturing (APM). Previous theoretical and experimental works on atom by atom and molecule by molecule fabrication of precise structures are limited to essentially to two-dimensions. APM will enable a paradigm shift in 21st century manufacturing practices in which every single atom in a electronic chip, device or machine can be placed in an exact and predefined position in three-dimensions. By providing a general method for generating reproducible SPM tip structure, this project will drive forward the entire field of atomically precise scanning probe microscopy, opening the door to positional control of nearly arbitrary covalent chemistry. Such control could, for example, be used in applications such as novel 2.5 or 3D microchip fabrication. The creation of a unique manufacturing method through APM has the potential to impact technologies at the theoretical limits of performance, weight, and utility including: solid-state quantum and spintronic computing systems, high efficiency optical antenna, solar power systems, defect engineered materials and extremely efficient catalysts. Although this experiment focused on pick-and-place non-scalable APM, the better understanding of the chemistry is crucial to the eventual goal of scalable APM. To place individual atoms into a specified location is a seminal aspiration of researchers and engineers in the many fields and may have early premium applications in medical devices and microelectronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Proliferated Resilient Economical Half-Meter Aperture Space Telescopes (PREEMPT)

The PREEMPT LDRD was motivated by a major national need for better space-based imaging systems that are both high performing and affordable for the US Government. Current optical payloads for intelligence, surveillance and reconnaissance (ISR) and space domain awareness (SDA) missions can cost hundreds of millions of dollars and take years to develop, which makes it difficult to build the large constellations required for persistent, world-wide coverage. To address this, the team aimed to advance a different kind of large-aperture (>25 cm) telescope, called a monolithic telescope, in which key optical surfaces are built into a single piece of fused silica. This design greatly reduces payload and spacecraft complexity, the need for precision focus actuators, improves mechanical and thermal robustness, and lowers cost when compared with traditional Cassegrain telescopes that rely on many precisely aligned components. The project focused on five primary thrusts. The first thrust was to advance the concept of a V10, 25 cm, monolithic telescope forward from optical design to flight-ready stage. This was accomplished in partnership with Optimax, who delivered the first test unit in the early stages of the LDRD. The team developed several technologies necessary for this optic to be integrated into a flight demonstration. These include carbon fiber housings, highly detailed structural and thermal models and stress-reducing elastic averaging Hirth groove designs. These technologies resulted in a successful maturation of the optic, which is now slated to fly in late 2026/early 2027 for a demonstration mission. The second thrust was to advance the manufacturability of these optics. In collaboration with NIF’s optical manufacturing shop, we reduced polishing time from 480 hours to 65 hours through the implementation of optimized processes and new tools. The NIF team utilized a conceptual V8 (18 cm) optic to demonstrate this optimization, though it can be applied to the rest of the monolithic optic portfolio. Third, the team developed the first conceptual V20 (50 cm) payload, which is slated to be the next generation of LLNL optical payload systems. A set of structural, dynamic and thermal simulations were performed to identify potential challenges in the future development of this payload. Early-stage simulations suggest the payload is feasible, though thermal management will be the key focus area to maintain optimal performance. Fourth, a non-linear model of Viton was developed, to further enhance the reliability of our structural and dynamic models for future payloads. Viton acts as the primary interface material between the optic and its housing. Lastly, the team focused on successfully displaying the feasibility of using additively manufactured metal composites for optical space payloads. The team successfully demonstrated layer by layer deposition of Al-SiC composites, which have highly tunable structural and coefficient of thermal expansion (CTE) properties. These are crucial for optical payloads because CTE mismatch is one of the causes for degraded optical performance for telescopes in orbit. Overall, the work showed that monolithic telescopes could become a practical, lower-cost path to high-resolution space imaging for both national security and scientific missions.

42 ENGINEERING↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Coherent Control over Nuclear Hyperpolarization Using an Optically Initializable Chromophore-Radical System

Chromophore radicals (CR) are emerging as important components for molecular quantum information science (QIS), especially in the context of quantum sensing. Here, we demonstrate that the optically hyperpolarized electrons in a 1,6,7,12-tetrakis(4-tert-butylphenoxy)-perylene-3,4,9,10-bis(dicarboximide) (tpPDI) covalently linked to a partially deuterated 1,3-bis(diphenylene)-d 16 -2-phenylallyl radical (BDPA-d 16 ) can be coherently manipulated via pulsed dynamic nuclear polarization (DNP) methods to transfer polarization to nuclear spins and back. Under light illumination at 85 K, electron hyperpolarization in BDPA is enhanced 2.1- to 2.4-fold over thermal polarization and lasts for more than 100 ms. By applying nuclear orientation via electron spin-locking (NOVEL) DNP, this optically amplified electron hyperpolarization was successfully transferred to a 1 H nuclear spin within the CR system and efficiently returned to the electron spin for readout via reverse-NOVEL. The NOVEL transfer efficiency of 65% amounts to a 688-fold nuclear spin hyperpolarization of the target nuclear spin, considering the 2.1-fold electron spin hyperpolarization. This reversible coherent manipulation of hyperpolarization transfer highlights the utility of CR systems to initialize and read out nuclear spin states in a disordered matrix at moderate cryogenic temperatures. Coupled with CRs’ environmental compatibility, tunability, and precise state initialization, these results highlight the promising role of nuclear spins in CRs for QIS applications, including quantum sensing and memory.

charge transfer↗

Investigation of a gallium alloy liquid metal mirror for application in inertial fusion energy systems

The final optic in future inertial fusion energy plants must maintain high performance and survivability under gigashot laser irradiation while exposed to fusion byproducts. Although no practical solution has been demonstrated, a self-healing final turning mirror based on a grazing-incidence liquid metal mirror has been theoretically explored. This work investigates the suitability of a gallium alloy. The experimental system simulates key conditions, including vacuum exposure and 10-Hz, 355-nm, and 6-ns laser pulses. Experiments address reflectivity, damage, and response as a function of pressure. Results highlight the potential of liquid metal gallium alloys for robust final optics in laser-based fusion power plants and inform non-traditional optics for intense laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Development of a scintillator based fast-ion loss detector for the Wendelstein 7-X stellarator

A new scintillator based fast-ion loss detector (FILD) system has been designed for the Wendelstein 7-X (W7-X) stellarator. The mechanical design of the system is presented here along with engineering analyses of the system. This includes an assessment of the structural loads which also considers electromagnetic forces calculated for possible disruption scenarios as well as a mode frequency analysis of the system. Furthermore, an analysis of the thermal characteristics of the actively cooled probe head under prescribed steady state and transient heat loads is presented. Finally, the optical relay system is described and its properties used to forward model synthetic camera signals using the FILDSIM code and based on theoretical fast-ion losses incident on the probe head calculated using the ASCOT5 code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting critical heat flux using localized sensing at invisible vapor-liquid interfaces

Predicting critical heat flux (CHF) in two-phase electronics cooling systems remains a significant challenge due to the sudden onset of boiling crisis and the difficulty in directly visualizing vapor-liquid interfaces. Existing sensing methods rely on lagging temperature measurements, optically accessible systems, or spatially averaged signals that cannot pinpoint CHF initiation at localized high-heat-flux regions. Here, we report a planar capacitive sensing approach that enables real-time, localized detection of vapor-liquid interface dynamics for CHF prediction in boiling heat transfer. The capacitive sensor exploits the dielectric constant difference between liquid and vapor phases to capture bubble nucleation, growth, and departure dynamics with a temporal resolution down to 2 ms. The capacitive sensing reveals distinct signals across boiling regimes: from high-frequency fluctuations during strong nucleate boiling to low-frequency fluctuations with increased amplitudes when approaching CHF. The multi-sensor array experiments demonstrate real-time localized sensing, where each sensor responds exclusively to boiling in its immediate vicinity without crosstalk from neighboring regions. This non-intrusive sensing approach provides predictive rather than lagging sensing signals of CHF occurrence, offering predictive diagnosis of two-phase liquid cooling for the thermal management of high-power-density electronics.

CHF↗

Single-photon detection using large-scale high-temperature MgB2 sensors at 20 K

Abstract Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB 2 ) thin-film superconducting microwires capable of single-photon detection at 1.55 μ m optical wavelength. We used helium ions to alter the properties of MgB 2 , resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 μ m wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 μ m 2 , the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗