Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical absorption spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of atomic oxygen and ultraviolet radiation on candidate elastomeric materials for long duration missions. Test series no.1

Research was conducted at MSFC on the behavior of elastomeric materials after exposure to simulated space environment. Silicone S383 and Viton V747 samples were exposed to thermal vacuum, ultraviolet radiation, and atomic oxygen and then evaluated for changes in material properties. Characterization of the elastomeric materials included weight, hardness, optical inspection under normal and black light, spectrofluorescence, solar absorptance and emittance, Fourier transform infrared spectroscopy, and permeability. These results indicate a degree of sensitivity to exposure and provided some evidence of UV and atomic oxygen synergism.

Linton, R. C.↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin C Tibere-Inglesse↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin Tibère-Inglesse↗

'Diamondlike' carbon films - Optical absorption, dielectric properties, and hardness dependence on deposition parameters

An RF plasma deposition system was used to prepare amorphous 'diamondlike' carbon films. The source gases for the RF system include methane, ethylene, propane, and propylene, and the parameters varied were power, dc substrate bias, and postdeposition anneal temperature. Films were deposited on various substrates. The main diagnostics were optical absorption in the visible and in the infrared, admittance as a function of frequency, hardness, and Auger and ESCA spectroscopy. Band gap is found to depend strongly on RF power level and band gaps up to 2.7 eV and hardness up to 7 Mohs were found. There appears to be an inverse relationship between hardness and optical band gap.

Natarajan, V.↗

High-Sensitivity Optical Techniques for Atmospheric Spectroscopy, Kinetics and Remote Sensing

A principal objective of the work supported by this Grant has been to use IntraCavity Laser Absorption Spectroscopy (ICLAS) to acquire data on weakly absorbing species of atmospheric interest that are not accessible, or cannot be determined with sufficient precision, using conventional spectroscopic instrumentation. The principal focus has been to adapt the existing instrument to carry out Kinetic studies using IntraCavity Absorption Spectroscopy (KICAS) in order to measure rate parameters for weakly absorbing, environmentally significant species. Additional related work has been carried out in collaboration with Prof. M.J. Molina's program on air pollution in the Mexico City Metropolitan Area on modeling the role of these species in atmospheric chemistry.

Source record↗

XMM-Newton Spectroscopy of the X-ray Detected Broad Absorption Line QSO CSO 755

We present the results from XMM-Newton observations of the highly optically polarized broad absorption line quasar (BALQSO) CSO 755. By analyzing its X-ray spectrum with a total of approximately 3000 photons we find that this source has an X-ray continuum of "typical" radio-quiet quasars, with a photon index of Gamma=1.83, and a rather flat (X-ray bright) intrinsic optical-to-X-ray spectral slope of alpha_ox=- 1.51. The source shows evidence for intrinsic absorption, and fitting the spectrum with a neutral-absorption model gives a column density of N_H approximately 1.2x10^22 cm^{-2}; this is among the lowest X-ray columns measured for BALQSOs. We do not detect, with high significance, any other absorption features in the X-ray spectrum. Upper limits we place on the rest-frame equivalent width of a neutral (ionized) Fe K-alpha line, less than =180 eV (less than =120 eV), and on the Compton-reflection component parameter, R less than =0.2, suggest that most of the X-rays from the source are directly observed rather than being scattered or reflected; this is also supported by the relatively flat intrinsic alpha ox we measure. The possibility that most of the X-ray flux is scattered due to the high level of UV-optical polarization is ruled out. Considering data for 46 BALQSOs from the literature, including CSO 755, we have found that the UV-optical continuum polarization level of BALQSOs is not correlated with any of their X-ray properties. A lack of significant short-term and long-term X-ray flux variations in the source may be attributed to a large black-hole mass in CSO 755. We note that another luminous BALQSO, PG 2112+059, has both similar shallow C IV BALs and moderate X-ray absorption.

Brandt, Niel↗

Advanced smoke meter development survey and analysis

Ideal smoke meter characteristics are determined to provide a basis for evaluation of candidate systems. Five promising techniques are analyzed in detail to evaluate compilance with the practical smoke meter requirements. Four of the smoke measurement concepts are optical methods: Modulated Transmission (MODTRAN), Cross Beam Absorption Counter (CBAC), Laser Induced Incandescence (LIN), and Photoacoustic Spectroscopy (PAS). A rapid response filter instrument called a Taper Element Oscillating Microbalance (TEOM) is also evaluated. For each technique, the theoretical principles are described, the expected performance is determined, and the advantages and disadvantages are discussed The expected performance is evaluated against each of the smoke meter specifications, and the key questions for further study are given. The most promising smoke meter technique analyzed was MODTRAN, which is a variation on a direct transmission measurement. The soot-laden gas is passed through a transmission cell, and the gas pressure is modulated by a speaker.

Pitz, R. W.↗

Auger electron spectroscopy, secondary ion mass spectroscopy and optical characterization of a-C-H and BN films

The amorphous dielectrics a-C:H and BN were deposited on III-V semiconductors. Optical band gaps as high as 3 eV were measured for a-C:H generated by C4H10 plasmas; a comparison was made with bad gaps obtained from films prepared by CH4 glow discharges. The ion beam deposited BN films exhibited amorphous behavior with band gaps on the order of 5 eV. Film compositions were studied by Auger electron spectroscopy (AES), x-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS). The optical properties were characterized by ellipsometry, UV/VIS absorption, and IR reflection and transmission. Etching rates of a-C:H subjected to O2 dicharges were determined.

Pouch, J. J.↗

Radiation resistance studies of amorphous silicon films

A study of hydrogenated amorphous silicon thin films irradiated with 2.00 MeV helium ions using fluences ranging from 1E11 to 1E15/sq cm is presented. The films were characterized using photothermal deflection spectroscopy, transmission and reflection spectroscopy, and photoconductivity and annealing measurements. Large changes were observed in the subband-gap optical absorption for energies between 0.9 and 1.7 eV. The steady-state photoconductivity showed decreases of almost five orders of magnitude for a fluence of 1E15/sq cm, but the slope of the intensity dependence of the photoconductivity remained almost constant for all fluences. Substantial annealing occurs even at room temperature, and for temperatures greater than 448 K the damage is completely annealed. The data are analyzed to describe the defects and the density of states function.

Payson, J. Scott↗

A 21 Centimeter Absorber Identified with a Spiral Galaxy: Hubble Space Telescope Faint Object Spectrograph and Wide-Field Camera Observations of 3CR 196

We present imaging and spectroscopy of the quasar 3CR 196 (z(sub e) = 0.871), which has 21 cm and optical absorption at z(sub a) = 0.437. We observed the region of Ly alpha absorption in 3CR 196 at z(sub a) = 0.437 with the Faint Object Spectrograph on the Hubble Space Telescope. This region of the spectrum is complicated because of the presence of a Lyman limit and strong lines from a z(sub a) approx. z(sub e) system. We conclude that there is Ly alpha absorption with an H I column density greater than 2.7 x 10(exp 19) cm(exp -2) and most probably 1.5 x 10(exp 20) cm(exp -2). Based on the existence of the high H I column density along both the optical and radio lines of sight, separated by more than 15 kpc, we conclude that the Ly alpha absorption must arise in a system comparable in size to the gaseous disks of spiral galaxies. A barred spiral galaxy, previously reported as a diffuse object in the recent work of Boisse and Boulade, can be seen near the quasar in an image taken at 0.1 resolution with the Wide Field Planetary Camera 2 on the HST. If this galaxy is at the absorption redshift, the luminosity is approximately L(sub *) and any H I disk should extend in front of the optical quasar and radio lobes of 3CR 196, giving rise to both the Ly alpha and 21 cm absorption. In the z(sub a) approx. z(sub e) system we detect Lyman lines and the Lyman limit, as well as high ion absorption lines of C III, N V, S VI, and O VI. This absorption probably only partially covers the emission-line region. The ionization parameter is approximately 0.1. Conditions in this region may be similar to those in broad absorption line QSOs.

Cohen, Ross D.↗

Hollow waveguide cavity ringdown spectroscopy

Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.

Dreyer, Chris↗

On the evaluation of air mass factors for atmospheric near-ultraviolet and visible absorption spectroscopy

The interpretation of UV-visible twilight absorption measurements of atmospheric chemical constituents is dependent on how well the optical path, or air mass factor, of light collected by the spectrometer is understood. A simple single scattering model and a Monte Carlo radiative transfer scheme have been developed to study the effects of multiple scattering, aerosol scattering, surface albedo and refraction on air mass factors for scattered light observations. At fairly short visible wavelengths (less than about 450 nm), stratospheric air mass factors are found to be relatively insensitive to multiple scattering, surface albedo and refraction, as well as aerosol scattering by background aerosols. Longer wavelengths display greater sensitivity to refraction and aerosol scattering. Tropospheric air mass factors are found to be highly dependent on aerosol scattering, surface albedo and, at long visible wavelengths (about 650 nm), refraction. Absorption measurements of NO2 and O4 are shown to support these conclusions.

Perliski, Lori M.↗

Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport

The objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the crystals grown by vapor transport as results of buoyance-driven convection and growth interface fluctuations caused by irregular fluid-flows. ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, were grown by vapor transport technique with real time in-situ non-invasive monitoring techniques. The grown crystals were characterized extensively to correlate the grown crystal properties with the growth conditions. The following are the research progress in the past two years. In-situ monitoring of partial pressure by optical absorption technique and visual observation of the growing crystal were performed during vapor growth of ZnSe. Low-temperature photoluminescence (PL) spectra and glow discharge mass spectroscopy (GDMS) were measured on ZnSe starting materials provided by various vendors and on bulk crystals grown from these starting materials by physical vapor transport (PVT) to study the effects of purification and contamination during crystal growth process. Optical characterization was performed on wafers sliced from the grown crystals of ZnSe, ZnTe and ZnSe(1-x),Te(x), (0<x<0.4). Energy band gaps at room temperature were determined from optical transmission measurements and a best fit curve to the band gap vs. composition, x, data gives a bowing parameter of 1.45. Low-temperature photoluminescence (PL) spectra of ZnSe and ZnTe were dominated by near band edge emissions and no deep donor-acceptor pairs were observed. The PL spectrum exhibited a broad emission for the ZnSe(1-x),Te(x), samples, 0.09<x<0.39. The single broad PL emission spectra and the spectra measured as a function of temperature were interpreted as being associated with the exciton bound to Te clusters because of the high Te content in these samples. To validate numerical codes, in-situ monitoring during the PVT of HgI2 was designed. Optical absorption spectra of the vapor phase over HgI2 were measured for wavelengths between 200 and 600nm at sample temperatures between 349 and 610K. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were determined. From these constants the vapor pressure of HgI2 was established as a function of temperature for the liquid and the solid Beta-phases To characterize the growth conditions during the PVT growth of In-doped ZnSe the optical absorbance of the vapor phase over the In-Se system were measured and were used to obtain the partial pressures of Se2(g) and In2Se(g).

Su, Ching-Hua↗

Optical Breath Gas Extravehicular Activity Sensor for the Advanced Portable Life Support System

The function of the infrared gas transducer used during extravehicular activity (EVA) in the current space suit is to measure and report the concentration of carbon dioxide (CO2) in the ventilation loop. The next generation portable life support system (PLSS) requires highly accurate CO2 sensing technology with performance beyond that presently in use on the International Space Station extravehicular mobility unit (EMU). Further, that accuracy needs to be provided over the full operating pressure range of the suit (3 to 25 psia). Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. A laser diode (LD) sensor based on infrared absorption spectroscopy is being developed for this purpose by Vista Photonics, Inc. Version 1.0 prototype devices were delivered to NASA Johnson Space Center (JSC) in September 2011. The prototypes were upgraded with more sophisticated communications and faster response times to version 2.0 and delivered to JSC in July 2012. The sensors incorporate a laser diode based CO2 channel that also includes an incidental water vapor (humidity) measurement. The prototypes are controlled digitally with an field-programmable gate array microcontroller architecture. Based on the results of the iterative instrument development, further prototype development and testing of instruments were performed leveraging the lessons learned where feasible. The present development extends and upgrades the earlier hardware for the advanced PLSS 2.5 prototypes for testing at JSC. The prototypes provide significantly enhanced accuracy for water vapor measurement and eliminate wavelength drift affecting the earlier versions. Various improvements to the electronics and gas sampling are currently being advanced including the companion development of engineering development units that will ultimately be capable of radiation tolerance. The combination of low power electronics with the performance of a long wavelength laser spectrometer enables multi-gas sensors with significantly increased performance over that presently offered in the EMU.

Wood, William R.↗

Analyses of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4) Contamination Samples

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of environmental effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center developed a series of experiments that were flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). Recently, four Glenn experiments with 365 flight samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Each of these experiments included passive contamination witness samples in each flight direction for post-flight molecular contamination analyses. A total of 13 contamination flight samples were flown. The post-flight analyses of the PCE 1-4 contamination samples include X-ray Photoelectron Spectroscopy (XPS) analyses (surface and ion sputter depth analyses) and optical properties (total reflectance, total transmittance and solar absorptance). This paper provides results of post-flight analyses of the PCE 1-4 contamination samples and their corresponding control samples. Knowledge of on-orbit contamination is important for the PCE 1-4 flight data interpretation.

Atomic Oxygen↗

Real-time measurements of endogenous CO production from vascular cells using an ultrasensitive laser sensor

Carbon monoxide (CO) has been implicated as a biological messenger molecule analogous to nitric oxide. A compact gas sensor based on a midinfrared laser absorption spectroscopy was developed for direct and real-time measurement of trace levels (in approximate pmol) of CO release by vascular cells. The midinfrared light is generated by difference frequency mixing of two nearinfrared lasers in a nonlinear optical crystal. A strong infrared absorption line of CO (4.61 microm) is chosen for convenient CO detection without interference from other gas species. The generation of CO from cultured vascular smooth muscle cells was detected every 20 s without any chemical modification to the CO. The sensitivity of the sensor reached 6.9 pmol CO. CO synthesis was measured from untreated control cells (0.25 nmol per 10(7) cells/h), sodium nitroprusside-treated cells (0.29 nmol per 10(7) cells/h), and hemin-treated cells (0.49 nmol per 10(7) cells/h). The sensor also detected decreases in CO production after the addition of the heme oxygenase (HO) inhibitor tin protoporphyrin-IX (from 0.49 to 0.02 nmol per 10(7) cells/h) and increases after the administration of the HO substrate hemin (from 0.27 to 0.64 nmol per 10(7) cells/h). These results demonstrate that midinfrared laser absorption spectroscopy is a useful technique for the noninvasive and real-time detection of trace levels of CO from biological tissues.

Non-NASA Center↗

Two X-ray-selected BL Lacertae objects observed with the HEAO 1 scanning modulation collimator

Two 16th magnitude BL Lac objects, H1101 - 232 and H1426 + 428, have been discovered. Each is a persistent and relatively bright X-ray source. A 2.7 percent linear polarization is measured in the optical emission or H101 - 232. The X-ray identification of H1426 + 428 is confirmed in an Exosat observation. The X-ray spectrum is well-modeled by a power law with an energy index of 1.19. Both BL Lac objects exhibit high f(x)/f(opt) ratios and they show a distinct resemblance to other X-ray selected BL Lac objects. The host galaxies are about 18th mag with angular diameters of about 20 arcsec and each may be the dominant member of a cluster of galaxies. Additional wide-slit spectroscopy reveals faint absorption features with redshifts of 0.129 for H1426 + 428 and 0.186 for H1101 - 232. The implied X-ray and optical luminosities exceed 10 to the 45th ergs/s for both BL Lac nuclei, assuming isotropic emission.

Remillard, R. A.↗

Theoretical models of interstellar shocks. I - Radiative transfer and UV precursors

Theoretical models of interstellar radiative shocks are constructed, with special attention to the transfer of ionizing radiation. These models are 'self-consistent' in the sense that the emergent ionizing radiation (the UV precursor) is coupled with the ionization state of H, He, and the metals in the preshock gas. For shock velocities of at least 110 km/s the shocks generate sufficient UV radiation for complete preionization of H and He, the latter to He(+). At lower velocities the preionization can be much smaller, with important consequences for the cooling function, the shock structure, and the emission. For models with shock velocities of 40 to 130 km/s the intensities of the strongest emission lines in the UV, optical, and infrared are tabulated, as well as postshock column densities of metal ions potentially observable by UV absorption spectroscopy. Possible applications to supernova remnants and high-velocity interstellar gas are assessed.

Shull, J. M.↗