Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical components”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Octave bandwidth photonic fishnet-achromatic-metalens

Planar structured interfaces, also known as metasurfaces, are continuously attracting interest owing to their ability to manipulate fundamental attributes of light, including angular momentum, phase, or polarization. However, chromatic aberration, limiting broadband operation, has remained a challenge for metasurfaces-based optical components and imagers. The limitation stems from the intrinsic dispersion of existing materials and design principles. Here we report and experimentally demonstrate polarization-independent fishnet-achromatic-metalenses with measured average efficiencies over 70% in the continuous band from the visible (640 nm) to the infrared (1200 nm). Results of the scalable platform are enabling for applications requiring broad bandwidth and high efficiency including energy harvesting, virtual reality and information processing devices, or medical imaging.

36 MATERIALS SCIENCE↗

On-Chip Single-Layer Integration of Diamond Spins with Microwave and Plasmonic Channels

On-chip scalable integration represents a major challenge for practical quantum devices. One particular challenge is to implement on-chip optical readout of spins in diamond. This readout requires simultaneous application of optical and microwave fields along with the efficient collection of fluorescence. These requirements are typically met using bulk optical components and dedicated microwave lines. Here, we experimentally demonstrate an on-chip integrated interface for diamond nitrogen vacancy (NV) spin-state preparation and readout, implemented in a planar single layer with only one patterning step. A nanodiamond with NV centers is positioned inside a v-groove waveguide milled in a thick gold film. The gold film carries the microwave control signal, while the v-groove acts as a fluorescence collector and, potentially, as an integrated pump filter. Hence, the device dimensions and fabrication complexity are substantially reduced. Our approach fosters further development of ultracompact nanoscale quantum sensors and quantum information processing devices on a monolithic platform.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Abbreviated report_23-ERD-006)

High peak and average power laser systems are typically limited by the handling fluence of the optical components. In particular, the multilayer dielectric coatings are known to be much lower operational fluence than the more ideal bulk materials. In this project we proposed and succeeded in probing different established classes of damage prone precursors at different wavelengths to understand their fundamental laser damage response as a function of wavelength. This study helped to shed light on the fundamental physics of the non-linear precursors that govern laser damage phenomena for ns-regime pulsed laser damage. In this study, we utilized the onsite coating capabilities (VPL, IBS coating lab) to purposefully generate laser damage-prone precursors in hafnia-based coatings (both single and multi-layer coatings). Specifically, we engineered coatings with craze lines initiated by nodules, generated coatings with our xenon-based coating process to suppress nanobubble formation and generated hafnia coatings under controlled oxygen flow conditions to study hafnia sub-oxides and oxygen flow dependance. In these studies we found that craze lines are rife with precursors that are sensitive to ultra-violet light but not to infrared light; we found that the removal of nanobubbles helps with all wavelengths tested, but is most impactful for ultra-violet light; we also found that ultra-violet laser damage performance of hafnia is closely matched to oxygen flow rate, while the infrared performance may be slightly better at lower flow rates. During this LDRD we also successfully stood up a new laser damage testing capability, namely a wavelength agile damage test station to study the spectral response of known laser-induced damage precursors. This is a unique and important capability for Lawrence Livermore National Lab, allowing us to understand the spectral response of materials under high intensity irradiation and damage. This is a vital tool to understand non-linear optical response at wavelengths that we have previously been unable to test at.

36 MATERIALS SCIENCE↗

Roadmap for Optical Metasurfaces

Metasurfaces have recently risen to prominence in optical research, providing unique functionalities that can be used for imaging, beam forming, holography, polarimetry, and many more, while keeping device dimensions small. Despite the fact that a vast range of basic metasurface designs has already been thoroughly studied in the literature, the number of metasurface-related papers is still growing at a rapid pace, as metasurface research is now spreading to adjacent fields, including computational imaging, augmented and virtual reality, automotive, display, biosensing, nonlinear, quantum and topological optics, optical computing, and more. At the same time, the ability of metasurfaces to perform optical functions in much more compact optical systems has triggered strong and constantly growing interest from various industries that greatly benefit from the availability of miniaturized, highly functional, and efficient optical components that can be integrated in optoelectronic systems at low cost. This creates a truly unique opportunity for the field of metasurfaces to make both a scientific and an industrial impact. Furthermore, the goal of this Roadmap is to mark this “golden age” of metasurface research and define future directions to encourage scientists and engineers to drive research and development in the field of metasurfaces toward both scientific excellence and broad industrial adoption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near-Field Nanoimaging of Colloidal Transition Metal Dichalcogenide Waveguides

Bulk transition metal dichalcogenide (TMDC) nanostructures are regarded as promising material candidates for integrated photonics due to their high refractive index at the near-infrared wavelengths. Here in this work, colloidal TMDC waveguides with tailorable dimensions are prepared by a scalable synthetic approach. The optical waveguiding properties of colloidal nanowires are studied by the near-field nanoimaging technique. In addition to dependence on thickness and wavelength, the excitonic responses and resultant waveguide modes in TMDC nanowires can be modulated by the environmental temperature. With the high-throughput production and tunable optical properties, colloidal TMDC nanowires highlight the potential for active optical components and integrated photonic devices.

36 MATERIALS SCIENCE↗

Giant Nonlinear Optical Response via Coherent Stacking of In-Plane Ferroelectric Layers

Thin ferroelectric materials hold great promise for compact nonvolatile memory and nonlinear optical and optoelectronic devices. Herein, an ultrathin in-plane ferroelectric material that exhibits a giant nonlinear optical effect, group-IV monochalcogenide SnSe, is reported. Nanometer-scale ferroelectric domains with ≈90°/270° twin boundaries or ≈180° domain walls are revealed in physical-vapor-deposited SnSe by lateral piezoresponse force microscopy. Atomic structure characterization reveals both parallel and antiparallel stacking of neighboring van der Waals ferroelectric layers, leading to ferroelectric or antiferroelectric ordering. Ferroelectric domains exhibit giant nonlinear optical activity due to coherent enhancement of second-harmonic fields and the as-resulted second-harmonic generation was observed to be 100 times more intense than monolayer WS 2 . This work demonstrates in-plane ferroelectric ordering and giant nonlinear optical activity in SnSe, which paves the way for applications in on-chip nonlinear optical components and nonvolatile memory devices.

36 MATERIALS SCIENCE↗

TiN‐Au/HfO 2 ‐Au Multilayer Thin Films with Tunable Hyperbolic Optical Response

Abstract Hyperbolic metamaterials (HMM) possess significant anisotropic physical properties and tunability and thus find many applications in integrated photonic devices. HMMs consisting of metal and dielectric phases in either multilayer or vertically aligned nanocomposites (VAN) form are demonstrated with different hyperbolic properties. Herein, self‐assembled HfO 2 ‐Au/TiN‐Au multilayer thin films, combining both the multilayer and VAN designs, are demonstrated. Specifically, Au nanopillars embedded in HfO 2 and TiN layers forming the alternative layers of HfO 2 ‐Au VAN and TiN‐Au VAN. The HfO 2 and TiN layer thickness is carefully controlled by varying laser pulses during pulsed laser deposition (PLD). Interestingly, tunable anisotropic physical properties can be achieved by adjusting the bi‐layer thickness and the number of the bi‐layers. Type II optical hyperbolic dispersion can be obtained from high layer thickness structure (e.g., 20 nm), while it can be transformed into Type I optical hyperbolic dispersion by reducing the thickness to a proper value (e.g., 4 nm). This new nanoscale hybrid metamaterial structure with the three‐phase VAN design shows great potential for tailorable optical components in future integrated devices.

Chemistry↗

Performance evaluation of the SPES FEBIAD ion source

SPES (Selective Production of Exotic Species) is the Radioactive Ion Beam (RIB) facility that is currently in the installation phase at the Istituto Nazionale di Fisica Nucleare in the Laboratori Nazionali di Legnaro (LNL-INFN). The main purpose of the facility is to deliver neutron-rich radioactive beams with a range of mass between 60 and 160 amu produced as fission products originated within a Uranium Carbide (UC x ) target impinged by high energy protons (40–70 MeV). In the last few years, the SPES group and their collaborators have focused on multiple aspects: development of various ISOL targets, ion sources, a high-power beam dump, versatile Front-End designs, primary proton beam and RIB diagnostics, design of beam optic components, and remote target handling. The development and optimization of ionization sources represents one of the most important R&D activities. The collaboration between SPES and ISOLDE (CERN) groups has enabled the evaluation of the performances of a novel FEBIAD ion source taking advantage of the ISOLDE off-line Front-End. In this paper, the results of efficiency and transversal emittance measurements of the new SPES FEBIAD ion source are presented and discussed. Particular attention is dedicated to the description of the experimental setup and to the comparison of experimental data with simulation to promote the reproducibility of the experimental tests with other types of sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of 2D density profiles using a second-harmonic, dispersion interferometer

A second-harmonic, dispersion interferometer is used to image large-area (≃5 cm 2 ) plasma-jet and gas-jet density profiles. Achromatic telescopes magnify the diameters of the primary-laser beam (1064 nm) and its second-harmonic (532 nm) before probing the sample and de-magnify the beam diameters after the sample, where the primary beam transfers its phase change to a second, second-harmonic beam, allowing the sample’s dispersive-phase change to be measured between two, orthogonally polarized second harmonic beams. The telescopes produce an azimuthally symmetric, dispersive-phase shift in the sample + background phase-change image and in the background phase-change image, which is removed by digital subtraction. The interferometer’s performance was verified using standard-optical components as dispersive elements (BK7 lenses and wedge plates), resolving a minimum, phase-change sensitivity of ΔΦ min ≳ 15 mrad and spatial resolution of Δx res ≃ 100 μm. The phase change produced by unknown-density objects (a pulsed-plasma-jet and a pulsed-gas-jet) was measured, and their data were used to recover the original, 2D density profiles using an inverse Abel transform: peak-number density, N gas ≃ 6 × 10 20 cm –3 and N e ≃ 5 × 10 16 cm –3 ; line-integrated density, ∫N gas dl ~ 2 × 10 19 cm –2 and ∫N e dl ~ 1 × 10 16 cm –2 . The techniques and methods developed here are scalable to even larger probe-beam diameters and frame-capture rates, leading to a diagnostic capability that is well-suited for applications involving the real-time measurement of density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗

Optical design for the single crystal neutron diffractometer Pioneer

Pioneer is a single-crystal neutron diffractometer optimized for small-volume samples and weak signals at the Second Target Station at Oak Ridge National Laboratory. This paper presents the preliminary optical design progress, focusing on the rationale behind key design choices. It covers the T 0 and bandwidth disk choppers, guide and beam control system, incident-beam polarizer, scattering beam collimators, and additional strategies. The chopper locations are selected to maximize neutron transport while taking advantage of standardized shielding structures. To accommodate the maintenance shield, operational shutter, and polarizing V-cavity, the guide design includes significant gaps. When these optical components are moved out of the beam path, oversized collimators, rather than guides, will be translated in. Pioneer will utilize slit packages to control beam size and divergence and a translatable polarizing V-cavity. Absorbing panels are strategically placed near the end station to minimize background. An oscillating radial collimator, operating in a shift mode, will be used with the vertical cylindrical detector, while a fixed multi-cone collimator will be used with the bottom flat detector. In conclusion, these collimators will enable the detection of weak signals when complex sample environments are used.

47 OTHER INSTRUMENTATION↗

Design of a double-sided laser heating compatible piezoelectrically driven dynamic diamond anvil cell

Piezoelectrically driven dynamic diamond anvil cells are generally limited to use at room temperature due to spatial conflicts with the optical components necessary for double-sided laser heating. Here, this work describes the design of a double-sided laser-heating-compatible, piezoelectrically driven dynamic diamond anvil cell (LH-dDAC) that expands the range of experimentally accessible compression rate/temperature space. By developing a spatially in-parallel design, in which the diamond anvils and the piezo actuators lie alongside each other, the total length of the apparatus is reduced to 66.5 mm. The new LH-dDAC is capable of probing both overpressure and compression-rate effects on the kinetics of phase transitions. We illustrate the capability of the new LH-dDAC using the following cases: (1) a simultaneous pressure and temperature jump from 19.5 GPa and room temperature to 40 GPa and ≈1550 K and (2) a controlled compression ramp at ≈1850 K and ≈100 GPa/s. By pairing rapid compression with laser heating, the new LH-dDAC opens the door to studies of diffusionally controlled transformations at high pressures and temperatures.

Copley, J. A. [Princeton Univ., NJ (United States)↗

Guest Editorial

The design of X-ray optical systems is very different from that of conventional optical systems, whether it be for the peculiarities of synchrotron radiation or the grazing incidence operation of most X-ray optical components. Further, specific simulation tools are thus required to ensure that designs work as expected, and there is now a vibrant landscape of open-source, freely available software that can be used to that end, and explore new design concepts.

47 OTHER INSTRUMENTATION↗

Polarization-agnostic continuous-variable quantum key distribution

Here, we introduce a polarization-agnostic method for Gaussian-modulated coherent-state (GCMS) continuous-variable quantum key distribution (CVQKD). Due to the random and continuous nature of the GCMS protocol, Alice, the transmitter, can encode two distinct quadratures in each of two orthogonal polarization modes, such that Bob, the receiver, measures valid GCMS quadratures in a single polarization mode even when polarization changes occur during transmission. This method does not require polarization correction in the optical domain, does not require monitoring both polarization modes, reduces loss by eliminating optical components, and avoids the noise injected by polarization correction algorithms.

Williams, Brian P. [Oak Ridge National Laboratory ↗

Generation of Neutron Airy Beams

The Airy wave packet is a solution to the potential-free Schrödinger equation that exhibits remarkable properties such as self-acceleration, nondiffraction, and self-healing. Although Airy beams are now routinely realized with electromagnetic waves and electrons, the implementation with neutrons has remained elusive due to small transverse coherence lengths, low fluence rates, and the absence of neutron lenses. In this Letter, we overcome these challenges through a holographic approach and present the first experimental demonstration of neutron Airy beams. The presented techniques pave the way for fundamental physics studies with Airy beams of nonelementary particles, the development of novel neutron optics components, and the realization of neutron Airy-vortex beams. Published by the American Physical Society 2025

Sarenac, Dusan (ORCID:0000000185753367)↗

Speckle correlation as a monitor of X-ray free-electron laser induced crystal lattice deformation

X-ray free-electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, X-FEL beam-induced lattice alterations are investigated by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. It is shown that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Additionally, abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗