Search NASASearch

SEARCH · Search NASA

Results for “Optical emission spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

505 records · Page 5

The role of fast and slow dynamics in nonlinear resonant ultrasound spectroscopy of consolidated granular materials

Abstract Elastic nonlinearity observed in consolidated granular media can be attributed to the combination of slow and fast effects, which give rise to hysteresis and relaxation of both modulus and damping after the sample is perturbed. A consequence is a high level of complexity in the measurements of the sample linear and nonlinear elastic parameters. The results of experiments are dependent on the experimental protocol that is adopted to measure the relevant quantities and it is hard to quantify parameters with accuracy and repeatability. Here we focus on examining Nonlinear Resonant Ultrasound Spectroscopy, showing experimentally the role of slow dynamics in the process and quantifying/discussing its influence on the quantification of nonlinearity. We also propose a model to describe the process, which shows that different contributions to nonlinearity (e.g., classical and hysteretic) could be due to physical features (defects) relaxing with different relaxation times.

Science & Technology - Other Topics

Raman and Infrared Spectroscopy of Yttrium Aluminum Borate Glasses and Glass-ceramics

Raman spectra of glasses and glass-ceramics in the Y2O3-Al2O3-B2O3 system are reported. Glasses with B2O3 contents ranging from 40 to 60 mole percent were prepared by melting 20 g of the appropriate oxide or carbonate powders in alumina crucibles at 1400 C for 45 minutes. Subsequent heat treatments of the glasses at temperatures ranging from 600 to 800 C were performed in order to induce nucleation and crystallization. It was found that Na2CO3 added to the melt served as a nucleating agent and resulted in uniform bulk crystallization. The Raman spectra of the glasses are interpreted primarily in terms of vibrations of boron - oxygen structural groups. Comparison of the Raman spectra of the glass-ceramic samples with spectra of aluminate and borate crystalline materials reveal that these glasses crystallize primarily as yttrium aluminum borate, YAl3(BO3)4.

J Bradley

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

Evaluating Crystallinity in Thermoplastic composites

Polymer matrix composites (PMCs) offer many benefits for the aerospace industry due to their potential for weight reduction when compared to metal or ceramic based materials. Most PMCs currently in flight use thermoset matrices, however, thermoplastic resins are being explored as alternatives due to their ability to be remelted, which is of particular interest due to the potential for in-situ repair and manufacturing required in space. Most thermoplastic resins are semicrystalline polymers. The properties of semicrystalline thermoplastics are largely influenced by their crystallinity, which can vary due to many factors including thermal treatments, environmental conditions, and mechanical deformation. Monitoring the crystallinity of thermoplastic composites is key to ensuring these materials reliably meet the high demands required by space exploration. This talk discusses the use of multiple techniques such as Polarized Light Optical Microscopy and Fourier-Transform Infrared Spectroscopy to characterize the crystallinity in various thermoplastic composites, including carbon fiber reinforced PMCs and novel bio-based Martian and Lunar regolith composites designed for in-situ manufacturing. This work aims to provide the fundamental data necessary to understand the effects of crystallinity on thermoplastic PMCs, which is key to advancing their use in space applications.

Thermoplastics

Tetrel Bond-Mediated Photophysical Modulation and Fluoride Recognition in Carbazole-Organosilanes

Silicon-centered orbitals are typically regarded as electronically inert in donor–acceptor systems. Here, we show that silole-based carbazole–silane architectures can render these orbitals electronically relevant, enabling modulation of excited-state behavior and anion-responsive photophysics. Two carbazole–Dipp–silanes exhibit identical carbazole-localized LE singlet emission in solution yet diverge markedly in the solid state: one compound displays a broad long-wavelength emission band in the prompt spectrum and enhanced long-lived emission consistent with a triplet-derived excited state, likely arising from a combination of intramolecular structural locking and solid-state packing effects, whereas the more flexible analogue remains predominantly LE-emissive. Fluoride coordination further differentiates the two systems, producing ratiometric red-shifted emission in one case and fluorescence quenching in the other through a fully reversible coordination process. These results identify σ*(Si–Ar) orbitals as tunable contributors to excited-state landscapes in organosilane luminophores and suggest a broader design strategy for controlling excited-state behavior in tetrel-based photofunctional systems.

Haque, Md Hasanul

Kinetic control of phase evolution and defect-mediated recombination in AACVD-grown copper antimony sulphide thin films

Copper antimony sulphide (CAS) is a multinary chalcogenide semiconductor in which small deviations from stoichiometry can drive phase competition and strong defect-mediated modulation of optoelectronic properties. However, the systematic roles of copper precursor fraction and deposition time in governing phase evolution, off-stoichiometry, and recombination dynamics in aerosol-assisted chemical vapour deposition (AACVD)-grown undoped CAS thin films remain insufficiently understood. In this work, undoped CAS thin films were deposited by AACVD using Cu(dedtc)2 and Sb(dedtc)3 single-source precursors at 550 °C and a carrier gas flow rate of 150 sccm, while the Cu(dedtc)2 mole fraction (x = 0.15 – 0.55) and deposition time (1 – 2 hours) were systematically varied to probe how growth kinetics influence phase composition, microstructure, and defect-mediated optical properties without post-deposition annealing or extrinsic doping. Increasing copper precursor content drives phase evolution toward tetrahedrite-dominant CAS films at intermediate Cu(dedtc)2 mole fractions, with the film deposited at x = 0.35 exhibiting the strongest tetrahedrite character within the parameter space examined. The films are also copper-rich, antimony-poor, and sulphur-deficient, consistent with off-stoichiometric growth and intrinsic defect formation, plausibly including copper interstitials, Cu-on-Sb antisites, and sulphur vacancies. These growth-dependent compositional deviations are accompanied by tunable indirect optical bandgaps of approximately 1.60 – 2.18 eV and weak visible photoluminescence governed by defect-mediated recombination. Time-resolved photoluminescence reveals bi-exponential decay behaviour with lifetimes of approximately 0.1 – 3.6 ns, with emission dominated by slower donor–acceptor pair recombination and a smaller contribution from faster trap-assisted pathways. Collectively, these results establish an explicit kinetic process–structure–defect–property relationship for AACVD-grown CAS thin films and provide a growth–structure–property framework relevant to future optimization of CAS-based optoelectronic and energy materials.

36 MATERIALS SCIENCE

Gold Quantum Rods: Modulation of Singlet and Triplet Exciton Populations by the Rod Length

Abstract Gold quantum rods (QRs) of Au60, Au78, Au96, and Au114 (protected by thiolate ligands) exhibit exclusive fluorescence, which is different from the shorter Au42 QR with dual emission (fluorescence + phosphorescence). Herein, we report the excitation wavelength-dependent near-infrared-II photoluminescence (PL) and exciton dynamics of this series of QRs. Interestingly, the fluorescence quantum yield (QY) of the QRs is much higher (2–10×) when the lowest singlet excited state (S1) is excited compared to the excitation of high-lying states (Sn). A metastable intermediate singlet state (denoted S′) is identified by transient absorption spectroscopy when Sn is excited, and this S′ state leads to fast “skybridge” intersystem crossing (ISC), which contributes primarily (>60%) to the total triplet population. With increasing aspect ratio (AR) of QRs (from 6.3 to 18.7), nonradiative processes accelerate, leading to fast decay of the S1 state (hence, less QY) and of the T1 state (barely phosphorescent). A detailed energy flow mechanism is determined for the QRs after photoexcitation, which offers a design principle for manipulation of exciton dynamics toward potential utilization of higher excited states in applications.

77 NANOSCIENCE AND NANOTECHNOLOGY

Dust Composition of Comet 81P/Wild 2 From JWST Spectroscopy Compared to Stardust’s Fine-Grained Materials and Gems-Rich IDPS

The Stardust Mission returned samples from the coma of Jupiter Family comet 81P/Wild 2 for detailed laboratory analyses. Here we present and discuss the best-fit thermal dust model for the coma dust of comet 81P/Wild 2 as observed by JWST. Comet 81P was observed through JWST GO 018xx, using NIRSpec (2.9–5.3µm, λ/∆λ≈1000) and MRS IFU (4.9–28.1µm, λ/∆λ≈3000) on 2023-03-20 UT and 2023-03-24 UT, respectively, at a heliocentric distance of 1.85 au and JWST distance of 1.43 au (phase angle of 32 degrees). The dust coma of 81P as revealed by JWST offers a salient compliment to laboratory studies of Stardust samples that typically are bigger than 2 µm and up to 60 µm in size.

D H Wooden

Cyclic Peptides for Lanthanide Binding

Lanthanide ions are difficult to separate from one another due to their similar chemical properties. The discovery of lanthanide-binding peptides and proteins in nature has led to an increased interest in the possibility of utilizing the strong binding of peptides to lanthanide ions for their separations; as such, there has been an effort to identify or design peptides with improved lanthanide binding and selectivity toward particular lanthanide ions. Here, in this study, we designed and characterized lanthanide-binding cyclic peptides (LBCPs) with molecular dynamics simulations, electronic structure calculations, and emission spectroscopy. Luminescent decay measurements were done to determine the number of water molecules coordinated to the Eu 3+ ion in Eu-LBCP complexes and compare to the predicted number of water molecules by computation to assess the lanthanide-binding affinity of LBCPs. Measured stability constants show binding of the LBCPs to the Eu 3+ ion with stronger than micromolar affinity. We were able to identify multiple peptides that selectively bind to middle lanthanides. We describe the structural basis of the lanthanide-binding selectivity trend with strongest binding to the middle lanthanides, followed by the heavier lanthanides, and finally to the lighter ions.

ions

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Zero-field J-spectroscopy of quadrupolar nuclei

Abstract Zero- to ultralow-field nuclear magnetic resonance (ZULF NMR) allows molecular structure elucidation via measurement of electron-mediated spin-spinJ-couplings. This study examines zero-fieldJ-spectra from molecules with quadrupolar nuclei, exemplified by solutions of various isotopologues of ammonium cations. The spectra reveal differences between various isotopologues upon extracting preciseJ-coupling values from pulse-acquire measurements. A primary isotope effect,$$\triangle J=\left({\gamma }_{{}^{14}{{{{{\rm{N}}}}}}}/{\gamma }_{{}^{15}{{{{{\rm{N}}}}}}}\right){J}_{{}^{15}{{{{{\rm{N}}}}}}{{{{{\rm{H}}}}}}}-{J}_{{}^{14}{{{{{\rm{N}}}}}}{{{{{\rm{H}}}}}}}\approx -58$$ △ J = γ 14 N / γ 15 N J 15 N H − J 14 N H ≈ − 58 mHz, is deduced by analysis of the proton-nitrogenJ-coupling ratios. This study points toward further experiments with symmetric cations containing quadrupolar nuclei, promising applications in biomedicine, energy storage, and benchmarking quantum chemistry calculations.

Science & Technology - Other Topics

First in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF

This work details the construction and first in operando transient grating spectroscopy measurements conducted on PISCES-RF during plasma operation. A preliminary study on a tungsten sample with varied plasma species (Ar and D 2 ), ion flux (4 × 10 21 to 6 × 10 22 ion/m 2 /s), ion energy (5 to 80 eV), and surface temperature (20 to 200 °C) is presented. Prior to plasma exposure, the thermal diffusivity and surface acoustic wave (SAW) speed, (6.9 ± 0.2) × 10 −5 m 2 /s and (2.66 ± 0.02) km/s, were measured in situ with a thermal grating period of 12.5 μm. During Ar plasma exposure, these two quantities vary according to the sample surface temperature. At low flux and varied ion energy, D 2 plasma exposure also results in thermal diffusivity and SAW speed varying with surface temperature alone. At high flux, D 2 plasma exposure results in no convincing change to the thermal diffusivity, but the SAW speed is reduced. After returning to 20 °C, post plasma exposures, the thermal diffusivity and SAW speed almost recover to the initial value prior to exposure.

Surface acoustic wave SAW

Galileo Optical Experiment (GOPEX) Optical Train: Design and Validation at the Table Mountain Facility

The Galileo Optical Experiment (GOPEX) has demonstrated the first laser communications uplink to a deep space vehicle. This article describes the optical design and validation tests performed at the Table Mountain Facility (TMF) transmitter site. The system used a 0.6-m telescope and an optical system at coude focus to produce the uplink beam. The optical system used a pulsed neodymium:yttrium-aluminum-garnet (Nd:Yag) laser and beam diverger optics to produce the required optical output. In order to validate the optical design, a number of uplinks were performed on Earth-orbiting satellites (e.g., Lageos 1 and 2).

J Yu

Reduced fast-ion transport calculations of m = n = 1 fishbone-like instabilities in MAST-U

Fast-ion transport associated with an m = n = 1 fishbone-like burst in MAST-U discharge 47128 is investigated using a reduced guiding-center-based transport model (ORBIT-Kick) constrained by multi-diagnostic measurements. The two-dimensional beam-emission spectroscopy system provides measurements of the core poloidal mode structure and fluctuation amplitude, while EFIT++ reconstructions constrained by the motional Stark effect diagnostic indicate a flat q-profile with q 0 > 1⁠, indicating the absence of a resonant q = 1 surface and supporting a pressure-driven infernal-mode interpretation. Analytic m = n = 1 displacement profiles consistent with the measured core mode structure and equilibrium constraints are used as the mode structure inputs to ORBIT-Kick. The calculations show that the dominant resonances occur between the mode and co-passing fast ions, producing redistribution localized near the magnetic axis. Synthetic neutron camera signals from TRANSP-Kick recover up to 90% of the experimentally observed neutron deficit at the time of peak mode amplitude, indicating that the measured m = n = 1 mode is a dominant contributor to core fast-ion transport. However, the synthetic neutron signals recover rapidly, whereas the measured neutron emission continues to decrease after the peak amplitude. In conclusion, the remaining discrepancy may arise from contributions not included in the present single-harmonic model, including higher-m and higher-n harmonics, multi-harmonic interactions, and additional transport mechanisms, motivating future diagnostic development and modeling efforts to resolve and incorporate these additional contributions.

Wong, Henry H. [University of California, Los Ange

Optical Telescope Technology

Design optics and technology for large spaceborne astronomical telescopes

Office of Space Science and Applications

Application of Nuclear Technology to Art Identification Problems: First Annual Report

Throughout the centuries, as man has become increasingly affluent, his interest in antiquities and objects of art, and the price he has been willing to pay for them, has increased. Inevitably, one result has been to attract the unscrupulous to the production and sale of counterfeit paintings, sculptures, and other works of art. The skill of forgers varies but often is highly sophisticated. However, dealers, museum curators, and other experts have also become more skillful in the detection of forgeries. Scientific tools of increasing sensitivity and sophistication have gradually been applied to the examination of the materials of art and archaeology. Such tools frequently support and render more reliable the judgment of the experts. The quality of forgeries may improve further as their makers become acquainted with the new methods of detection and in turn learn to circumvent or confound the methods. Therefore, the development of still more advanced methods of examination has great utility in the art world. This is particularly true if the ultimate effect is to make circumvention of the methods of examination so costly that the economic incentives for producing forgeries may be substantially reduced, if not eliminated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH