Luminescence and Scintillation in the Niobium Doped Oxyfluoride Rb4Ge5O9F6:Nb

A new niobium-doped inorganic scintillating oxyfluoride, Rb4Ge5O9F6:Nb, was synthesized in single crystal form by high-temperature flux growth. The host structure, Rb4Ge5O9F6, crystallizes in the orthorhombic space group Pbcn with lattice parameters a = 6.98430(10) Å, b = 11.7265(2) Å, and c = 19.2732(3) Å, consisting of germanium oxyfluoride layers made up of Ge3O9 units connected by GeO3F3 octahedra. In its pure form, Rb4Ge5O9F6 shows neither luminescence nor scintillation but when doped with niobium, Rb4Ge5O9F6:Nb exhibits bright blue luminescence and scintillation. The isostructural doped structure, Rb4Ge5O9F6:Nb, crystallizes in the orthorhombic space group Pbcn with lattice parameters a = 6.9960(3) Å, b = 11.7464(6) Å, and c = 19.3341(9) Å. X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) measurements suggest that the niobium is located in an octahedral coordination environment. Optical measurements inform us that the niobium dopant acts as the activator. The synthesis, structure, and optical properties are reported, including radioluminescence (RL) measurements under X-ray irradiation.

Carone, Darren (ORCID:0000000164014098)↗

Retractable Sensor for Reactor Experiments

This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next-generation perovskite photovoltaics: improving, stabilizing, and lead-sealing of record-setting laboratory solar cells towards commercialization

Summary: In the proposed program we plan to improve perovskite photovoltaic performance by developing (1) orientational control of 3D/2D perovskite heterostructures to simplify device architectures, thus improving device efficiencies and stability; (2) high-throughput optical measurements and real-time device simulations for device optimization; (3) robust, dual-pronged lead-sealing and oxygen/moisture/UV barrier films for long-term stability. Specifically, we seek to develop an in-depth understanding of the perovskite film formation, interface passivation, device stability, and environmentally friendly encapsulation, which together will lead to perovskite devices with PCE of over 28%, stability of T80 at 85/85 (85% humidity at 85 degrees C) for 10,000, expected to be equivalent to T90 of 100 hours), and architectures that would satisfy the U.S. EPA and RoHS limits of lead-leaching. The knowledge generated with this project will be applicable to tandem devices with wider-bandgap perovskites.

14 SOLAR ENERGY↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Sensitivity study

Power towers, a type of concentrating power tower technology, use a large number of heliostats to concentrate sunlight and produce renewable energy. Optical errors of heliostats can cause drastic losses in the efficiency of power-tower plants. Accurately measuring optical errors is crucial to assessing and improving plant performance. This analysis discusses an innovate non-intrusive optical (NIO) approach to measure slope, canting, and tracking errors by detecting distortions in the reflected tower structure in heliostat images. Further in this work a sensitivity study is carefully conducted to determine the uncertainty requirements to allow the method to calculate slope errors with an accuracy of 0.25 mrad. Measurement uncertainty sources include camera resolution and position uncertainty, tower position uncertainty, and number of collected images. Each uncertainty source is investigated to determine its impact on the accuracy of the slope-error calculation. A combination of theoretical results and experimental results obtained from data collected on a heliostat at Sandia National Laboratories is used to determine and validate uncertainty requirements. The analysis shows that a measurement uncertainty of 0.25 mrad can be realized by realistically controlling uncertainty sources when implementing the NIO method. It demonstrates the superior performance of NIO in performing in-situ optical characterization.

14 SOLAR ENERGY↗

Impact of dopant-induced band tails on optical spectra, charge carrier transport, and dynamics in single-crystal CdTe

Abstract Cadmium telluride (CdTe) semiconductors are used in thin-film photovoltaics, detectors, and other optoelectronic applications. For all technologies, higher efficiency and sensitivity are achieved with reduced charge carrier recombination. In this study, we use state-of-the-art CdTe single crystals and electro-optical measurements to develop a detailed understanding of recombination rate dependence on excitation and temperature in CdTe. We study recombination and carrier dynamics in high-resistivity (undoped) and arsenic (As)-doped CdTe by employing absorption, the Hall effect, time-resolved photoluminescence, and pump-probe in the 80–600 K temperature range. We report extraordinarily long lifetimes (30 µs) at low temperatures in bulk undoped CdTe. Temperature dependencies of carrier density and mobility reveal ionization of the main acceptors and donors as well as dominant scattering by ionized impurities. We also distinguish different recombination defects. In particular, shallow As Te and deep V Cd −As Cd acceptors were responsible for p-type conductivity. AX donors were responsible for electron capture, while nonradiative recombination centers (V Cd −As Te , As 2 precipitates), and native defects (V Cd −Te Cd ) were found to be dominant in p-type and n-type CdTe, respectively. Bimolecular and surface recombination rate temperature dependencies were also revealed, with bimolecular coefficient T −3/2 temperature dependence and 170 meV effective surface barrier, leading to an increase in surface recombination velocity at high temperatures and excitations. The results of this study allowed us to conclude that enhanced crucible rotation growth of As-doped CdTe is advantageous to As activation, leading to longer lifetimes and larger mobilities and open-circuit voltages due to lower absorption and trapping.

36 MATERIALS SCIENCE↗

Minimization of Measurement Uncertainty in Optical Frequency Domain Reflectometry

Optical frequency domain reflectometry (OFDR) is a technique for interrogating optical fiber sensors to generate relative, quasi-distributed measurements. Although Optical frequency domain reflectometry (OFDR) is increasingly being adopted for aerospace, energy production, and structural monitoring applications, the quantification of uncertainty for OFDR measurements has not been developed beyond sparse empirical relationships. To address this knowledge gap, an uncertainty metric for OFDR measurements was developed. This uncertainty metric was applied to weight the edges between OFDR measurements on directed correlation graphs and analyzed to minimize the cumulative uncertainty. In conclusion, this work is the first to propose an uncertainty metric for OFDR and provides a generalized mathematical framework for optimizing OFDR hardware selection, optical fiber sensor selection, and postprocessing strategy.

42 ENGINEERING↗

Low-loss adiabatic fiber-optic coupler for cryogenic photonics

Recent developments in quantum light–matter coupled systems and quantum transducers have highlighted the need for cryogenic optical measurements. In this study, we present a packaged fiber-optic coupler with a coupling efficiency of over 50% for telecom wavelength light down to the mK temperature range. Besides the high coupling efficiency, our method enables sensitive photonic device measurements that are immune to mechanical vibrations present in cryogenic setups.

Optics↗

System and method for controlling metal oxide gel particle size

Metal oxide gel particles, may be prepared with a desired particle size, by preparing a low-temperature aqueous metal nitrate solution containing hexamethylene tetramine as a feed solution; and causing the feed solution to flow through a first tube and exit the first tube as a first stream at a first flow rate, so as to contact a high-temperature nonaqueous drive fluid. The drive fluid flows through a second tube at a second flow rate. Shear between the first stream and the drive fluid breaks the first stream into particles of the metal nitrate solution, and decomposition of hexamethylene tetramine converts metal nitrate solution particles into metal oxide gel particles. A metal oxide gel particle size is measured optically, using a sensor device directed at a flow of metal oxide gel particles within the stream of drive fluid. The sensor device measures transmission of light absorbed by either the metal oxide gel particles or the drive fluid, so that transmission of light through the drive fluid changes for a period of time as a metal oxide gel particle passes the optical sensor. If a measured particle size is not about equal to a desired particle size, the particle size may be corrected by adjusting a ratio of the first flow rate to a total flow rate, where the total flow rate is the sum of the first and second flow rates.

Linneen, Nicholas N.↗

System and method for controlling metal oxide gel particle size

Metal oxide gel particles, may be prepared with a desired particle size, by preparing a low-temperature aqueous metal nitrate solution containing hexamethylene tetramine as a feed solution; and causing the feed solution to flow through a first tube and exit the first tube as a first stream at a first flow rate, so as to contact a high-temperature nonaqueous drive fluid. The drive fluid flows through a second tube at a second flow rate. Shear between the first stream and the drive fluid breaks the first stream into particles of the metal nitrate solution, and decomposition of hexamethylene tetramine converts metal nitrate solution particles into metal oxide gel particles. A metal oxide gel particle size is measured optically, using a sensor device directed at a flow of metal oxide gel particles within the stream of drive fluid. The sensor device measures transmission of light absorbed by either the metal oxide gel particles or the drive fluid, so that transmission of light through the drive fluid changes for a period of time as a metal oxide gel particle passes the optical sensor. If a measured particle size is not about equal to a desired particle size, the particle size may be corrected by adjusting a ratio of the first flow rate to a total flow rate, where the total flow rate is the sum of the first and second flow rates.

Linneen, Nicholas↗

CO 2 laser heating system for in situ radial x-ray absorption at 16-BM-D at the Advanced Photon Source

Here we present a portable CO 2 laser heating system for in situ x-ray absorption spectroscopy (XAS) studies at 16-BM-D (High Pressure Collaborative Access Team, Advanced Photon Source, Argonne National Laboratory). Back scattering optical measurements are made possible by the implementation of a Ge beamsplitter. Optical pyrometry is conducted in the near-infrared, and our temperature measurements are free of chromatic aberration due to the implementation of the peak-scaling method and mode scrambling of the input signal. Laser power stabilization is established using electronic feedback, providing a steady power over second timescales - crucial for longer XAS collections. Examples of in situ high pressure–temperature extended x-ray absorption fine structure measurements of ZrO 2 are presented to demonstrate this new capability.

36 MATERIALS SCIENCE↗

Picosecond Ultrasonics in Magnetic Topological Insulator MnBi 2 Te 4

MnBi 2 Te 4 is a magnetic topological insulator with layered A-type antiferromagnetic order. It exhibits a rich layer- and magnetic-state dependent topological phase diagram; however, much about the coupling between spin, charge, and lattice remains to be explored. Here, in this work, we report that MnBi 2 Te 4 is an excellent acoustic phonon cavity by realizing phonon frequency combs using picosecond ultrasonics. With the generated acoustic phonon wavepackets, we demonstrate that the timing and phase of acoustic echoes can be used to detect the presence of stacking faults between van der Waals layers buried deep within the crystal. Furthermore, by implementing this nondestructive ultrafast optical measurement in conjunction with time-resolved magneto-optical Kerr effect experiments, we uncover that out-of-plane vibrations in MnBi 2 Te 4 do not couple to the magnetic order, i.e. there is no appreciable magnetostriction. Our work points out how a well-developed technique can probe the structural defects and phonon pulse engineering in layered topological insulators.

36 MATERIALS SCIENCE↗

CAPS PMssa Aerosol Extinction and SSA Data

We collected rapid (1 second time response) measurements of aerosol extinction and scattering (Mm-1) using an Aerodyne CAPS PMssa deployed during LASIC (as part of the LASIC SSA-constraint study) to measure ambient SSA at 530 nm wavelength to compare with other optical measurement methods. Measured from August 4 to September 22, 2017. Sampled from both PM1 and PM10 inlets. CAPS PMssa monitors have been tested extensively for PM2.5 and smaller particle sizes, but not for particles greater than 2,500 nm in diameter (i.e., PM10). The data were collected in order to provide an independent measurement of aerosol single scattering albedo at 530 nm wavelength to compare with ARM standard methods.

54 ENVIRONMENTAL SCIENCES↗

Corroborating Channel Gap Probe Measurements with an Optical Profiler

As nuclear fuel plates get irradiated, the fuel plate thickness changes. How the fuel plate changes with irradiation is a significant parameter that is important to predict fuel performance in new fuel systems. The channel gap probe is used to indirectly infer changes in fuel plate thicknesses by measuring the gaps between the fuel plates contained within capsules after each irradiation cycle. Independent measures should be used to corroborate salient measurements such as changes in fuel thickness which help ascertain fuel performance. The use of traditional metrological tools to validate channel gap probe measurements are not practical due to the capsule geometry. The accuracy of the channel gap probe inserted within a capsule has not been verified. Since there is no “gold” standard measurement to verify CGP measurements, an optical profilometer has been used to corroborate the CGP measurements. The optical profilometer has been able to corroborate the capsules channel gaps to within 0.04 mm for both ends of the capsule. The optical profiler is also able to measure plate thickness that matched micrometer measurements to within 0.025 mm. In conclusion, the profilometer corroborated the CGP measurements but a discrepancy was found at one end of the capsule for the Inside Capsule Width from the profilometer when compared to a caliper measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chirality and dislocation effects in single nanostructures probed by whispering gallery modes

Nanostructures such as nanoribbons and -wires are of interest as components for building integrated photonic systems, especially if their basic functionality as dielectric waveguides can be extended by chiroptical phenomena or modifications of their optoelectronic properties by extended defects, such as dislocations. However, conventional optical measurements typically require monodisperse (and chiral) ensembles, and identifying emerging chiral optical activity or dislocation effects in single nanostructures has remained an unmet challenge. Here we show that whispering gallery modes can probe chirality and dislocation effects in single nanowires. Wires of the van der Waals semiconductor germanium(II) sulfide (GeS), obtained by vapor–liquid–solid growth, invariably form as growth spirals around a single screw dislocation that gives rise to a chiral structure and can modify the electronic properties. Cathodoluminescence spectroscopy on single tapered GeS nanowires containing joined dislocated and defect-free segments, augmented by numerical simulations and ab-initio calculations, identifies chiral whispering gallery modes as well as a pronounced modulation of the electronic structure attributed to the screw dislocation. Further, our results establish chiral light-matter interactions and dislocation-induced electronic modifications in single nanostructures, paving the way for their application in multifunctional photonic architectures.

36 MATERIALS SCIENCE↗

Classical vs. quantum plasmon-induced molecular transformations at metallic nanojunctions

Chemical transformations near plasmonic metals have attracted increasing attention in the past few years. Specifically, reactions occurring within plasmonic nanojunctions that can be detected via surface and tip-enhanced Raman (SER and TER) scattering were the focus of numerous reports. In this context, even though the transition between localized and nonlocal (quantum) plasmons at nanojunctions is documented, its implications on plasmonic chemistry remain poorly understood. We explore the latter through AFM-TER-current measurements. We use two molecules: i) 4-mercaptobenzonitrile (MBN) that reports on the (non)local fields and ii) 4-nitrothiophenol (NTP) that features defined signatures of its neutral/anionic forms and dimer product, 4,4′-dimercaptoazobenzene (DMAB). The transition from classical to quantum plasmons is established through our optical measurements: It is marked by molecular charging and optical rectification. Simultaneously recorded force and current measurements support our assignments. In the case of NTP, we observe the parent and DMAB product beneath the probe in the classical regime. Further reducing the gap leads to the collapse of DMAB to form NTP anions. The process is reversible: Anions subsequently recombine into DMAB. Our results have significant implications for AFM-based TER measurements and their analysis, beyond the scope of this work. In effect, when precise control over the junction is not possible (e.g., in SER and ambient TER), both classical and quantum plasmons need to be considered in the analysis of plasmonic reactions

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable multiphoton quantum metrology with neither pre- nor post-selected measurements

The quantum statistical fluctuations of electromagnetic fields establish a limit, known as the shot-noise limit, on the sensitivity of optical measurements performed with classical technologies. However, quantum technologies are not constrained by this shot-noise limit. In this regard, the possibility of using every photon produced by quantum sources of light to estimate small physical parameters, beyond the shot-noise limit, constitutes one of the main goals of quantum optics. Here, we experimentally demonstrate a scalable protocol for quantum-enhanced optical phase estimation across a broad range of phases, with neither pre- nor post-selected measurements. This is achieved through the efficient design of a source of spontaneous parametric downconversion in combination with photon-number-resolving detection. The robustness of two-mode squeezed vacuum states against loss allows us to outperform schemes based on N00N states, in which the loss of a single photon is enough to remove all phase information from a quantum state. In contrast to other schemes that rely on N00N states or conditional measurements, the sensitivity of our technique could be improved through the generation and detection of high-order photon pairs. This unique feature of our protocol makes it scalable. Furthermore, our work is important for quantum technologies that rely on multiphoton interference such as quantum imaging, boson sampling, and quantum networks.

36 MATERIALS SCIENCE↗

The Effect of Monomer Size on Fusion and Coupling in Colloidal Quantum Dot Molecules

The fusion step in the formation of colloidal quantum dot molecules, constructed from two core/shell quantum dots, dictates the coupling strength and hence their properties and enriched functionalities compared to monomers. Herein, studying the monomer size effect on fusion and coupling, we observe a linear relation of the fusion temperature with the inverse nanocrystal radius. This trend, similar to that in nanocrystal melting, emphasizes the role of the surface energy. The suggested fusion mechanism involves intraparticle ripening where atoms diffuse to the reactive connecting neck region. Moreover, the effect of monomer size and neck filling on the degree of electronic coupling is studied by combined atomistic-pseudopotential calculations and optical measurements, uncovering strong coupling effects in small QD dimers, leading to significant optical changes. Understanding and controlling the fusion and hence coupling effect allows tailoring the optical properties of these nanoscale structures, with potential applications in photonic and quantum technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of terahertz fields in LiTaO 3 waveguides using a conical pulse front

The development of methods for the generation of strong ultrafast electromagnetic pulses in the terahertz (THz) spectral range has led to a surge of progress in nonlinear THz spectroscopy and THz control of molecular and collective responses. For spectroscopy in the 1-THz range, the submillimeter wavelengths and associated large spot sizes, large optical elements, and short distances between final focusing elements and samples can lead to cumbersome experimental setups that are incompatible with some sample environments. Here, we introduce a novel terahertz ring excitation (TREx) optical pumping geometry to generate superposing, focusing fields in planar THz waveguides made out of the electro-optic material lithium tantalate. High THz fields, >175 kV/cm, are generated and measured optically with no free-space THz propagation. The field level achieved by pumping with a sequence of concentric rings of excitation light exceeds by about 20× the result of a single cylindrically focused line of pump light that has been used routinely in previous work. The technique opens new prospects for compact waveguide-based linear and nonlinear THz spectroscopy and signal processing.