Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Accelerated microwave-assisted synthesis and in situ X-ray scattering of tungsten-substituted vanadium dioxide (V 1-x W x O 2 )

Vanadium dioxide (VO 2 ) has been widely studied due to its metal-insulator phase transition at 68°C, below which it is a semiconducting monoclinic phase, P2 1 /c, and above it is a metallic tetragonal phase, P4 2 /mnm. Substituting vanadium with transition metals allows transition temperature tunability. An accelerated microwave-assisted synthesis for VO 2 and 5d tungsten substituted VO 2 presented herein decreased synthesis time by three orders of magnitude while maintaining phase purity, particle size, and transition character. Tungsten substitution amount was determined using inductively coupled plasma-optical emission spectroscopy. Differential scanning calorimetry, superconducting quantum interference device measurements, and in-situ heating and cooling experiments monitored through synchrotron x-ray diffraction (XRD) confirmed the transition temperature decreased with increased tungsten substitution. Scanning electron microscopy analyzed through the line-intercept method produced an average particle size of 3 – 5 μm. Average structure and local structure phase purity was determined through Rietveld analysis of synchrotron XRD and least-squares refinement of pair-distribution function data.

36 MATERIALS SCIENCE↗

Elemental Analysis of Bio-Oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Laboratory Analytical Procedure (LAP), Issue Date: May 13, 2022

Concentrations of inorganic elements is a key quality metric for bio-oils as certain elements impact upgrading processes and product quality. Unless reduced or removed during production and processing, alkali and alkaline metals native to lignocellulosic biomass can carry over into bio-oils contributing to ash content and degraded catalyst performance during upgrading to hydrocarbon fuels or chemical products. Non-metallic elements such as sulfur and phosphorus can also negatively impact upgrading catalysts and product quality. Inductively coupled plasma optical emission spectroscopy (ICP-OES) can be used to measure inorganic elements of interest in bio-oils. This procedure covers the preparation and analysis of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils. The concentrations of these elements can indicate potential bio-oil quality from the perspective of deoxygenation processes. The implications of elemental composition will depend on process parameters such as upgrading catalyst sensitivities. This Laboratory Analytical Procedure (LAP) covers two methods for quantification of inorganic elements by ICP-OES: Procedure A uses microwave assisted digestion with concentrated nitric acid, and Procedure B is an organic ICP-OES method utilizing a diglyme solvent.

09 BIOMASS FUELS↗

Chemical durability assessment of enhanced low-activity waste glasses through EPA method 1313

In this work, we report the progress of the Glass Leaching Assessment for Durability (GLAD) program on the implementation of the United States Environmental Protection Agency (EPA) Leaching Environmental Assessment Framework pH-dependent leach test (EPA Method 1313) to low-activity nuclear waste (LAW) glasses. The GLAD program seeks to develop new strategies to understand the chemical durability of nuclear waste glasses for the disposal in near-surface conditions. A series of 16 high-waste loading LAW glasses, currently under development, were selected using machine learning methods to study the corrosion behavior using EPA Method 1313. Reacted glass powders were examined using scanning electron microscopy and the eluate compositions were examined using inductively coupled plasma-optical emission spectroscopy. Compositional modeling was used to fit the measured elemental releases from EPA Method 1313. The compositional models demonstrated that elements such as Si reduce elemental release while B can increase elemental release (consistent with elemental modeling of the Product Consistency Test and Vapor Hydration Test) while other elements, such as Fe, exhibit pH-dependent behavior. The amount of acid added during the EPA testing was found to significantly impact the observed result, which was only apparent after preforming the present matrix study. The overall titration curves were able to be compositionally modeled for future process optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge

Toroidal current profile measurements in the tokamak plasma edge are critical for fusion plasma physics research and model validation. A three-wave Faraday-effect polarimeter-interferometer with a sub-centimeter spatial resolution is proposed on the DIII-D tokamak to determine the edge current profile via Abel inversion. By using probe beams with 316 µm wavelength, a low-field-side, vertical-view, single-pass optical layout covering the plasma edge region (R = 2.15–2.27 m) is assessed. Measurements with no greater than 0.1° polarimetric systematic uncertainty, no greater than 0.01° polarimetric root-mean-square noise (1 kHz bandwidth), and a 0.8 cm radial chord spacing are considered feasible based on the achieved performance of existing systems using similar wavelengths on fusion devices. Furthermore, synthetic diagnostic calculations taking various factors into account, such as diagnostic uncertainty and quality of magnetic flux surfaces, find that the edge current profile can be determined with up to 0.12 MA/m 2 uncertainty, or about 10% of the peak current density in the pedestal of an investigated high-confinement plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and reduction of Ar metastable densities by nitrogen admixing in electron beam-generated plasmas

Abstract Electron beam (e-beam) generated plasmas are useful for material processing applications such as deposition and etching because the plasmas deliver a large fluence of very low energy of ions to surfaces. Metastable species produced in the beam-region can also transport significant energy to the plasma periphery and surfaces. In this work, we have investigated the spatially resolved density of metastable Ar 1s 5 species produced in an Ar and Ar/N 2 e-beam generated plasma at pressures of 60–67 mTorr using laser-induced fluorescence (LIF). The experiments provide the first direct measure of absolute density and reduction of Ar 1s 5 in an e-beam generated plasma when argon is diluted with nitrogen. These results are consistent with previous predictions of numerical modeling and measurements using optical emission spectroscopy. The present spatially resolved LIF measurements directly quantify the reduction of Ar 1s 5 in the e-beam generated plasma by nitrogen admixing. This reduction was observed in the region of the electron beam and in the plasma periphery, where substrates are usually placed. For example, up to a threefold reduction of the density of Ar 1s 5 was measured when the argon background was diluted with 15.5% nitrogen at pressure of 60 mTorr. Ar 1s 5 reduction is attributed to excitation exchange with nitrogen molecules as well as the cooling of plasma electrons via inelastic collisions with nitrogen molecules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of machine learning for the estimation of electron energy distribution from optical emission spectra

Abstract This paper discusses the use of probabilistic deep neural networks for the prediction of the electron energy probability function in low-temperature non-thermal plasmas. The neural networks are trained using optical emission spectroscopy and Langmuir probe measurements, with the goal of providing a reliable estimate of the electron energy probability function solely from optical emission data. The performance of both non-Bayesian and Bayesian networks is evaluated. It is found that Bayesian models are preferable as they assign a higher level of uncertainty to their prediction especially when the dataset used to train them is small. This work describes one of the many potential applications of machine learning in plasma science and technology.

Physics↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial transient stage of pin-to-pin nanosecond repetitively pulsed discharges in air

In this work, evolution of parameters of nanosecond repetitively pulsed (NRP) discharges in pin-to-pin configuration in air was studied during the transient stage of initial 20 discharge pulses. Gas and plasma parameters in the discharge gap were measured using coherent microwave scattering, optical emission spectroscopy, and laser Rayleigh scattering for NRP discharges at repetition frequencies of 1, 10, and 100 kHz. Memory effects (when perturbations induced by the previous discharge pulse would not decay fully until the subsequent pulse) were detected for the repetition frequencies of 10 and 100 kHz. For 10 kHz NRP discharge, the discharge parameters experienced significant change after the first pulse and continued to substantially fluctuate between subsequent pulses due to rapid evolution of gas density and temperature during the 100 μs inter-pulse time caused by intense redistribution of the flow field in the gap on that time scale. For 100 kHz NRP discharge, the discharge pulse parameters reached a new steady-state at about five pulses after initiation. Further, this new steady-state was associated with well-reproducible parameters between the discharge pulses and substantial reduction in breakdown voltage, discharge pulse energy, and electron number density in comparison to the first discharge pulse. For repetition frequencies 1–100 kHz considered in this work, the memory effects can be likely attributed to the reduction in gas number density and increase in the gas temperature that cannot fully recover to ambient conditions before subsequent discharge pulses.

42 ENGINEERING↗

Hollow-cathode chemical vapor deposition of thick, low-stress diamond-like carbon films

A radio-frequency (RF), hollow-cathode plasma source with confining magnetic field is described for the chemical vapor deposition of thick ( > 10 µm), amorphous diamond-like carbon ablator films for inertial confinement fusion applications. Plasma is characterized by optical emission spectroscopy, while properties of the resultant films are measured by a combination of profilometry, Rutherford backscattering spectrometry, elastic recoil detection analysis, X-ray diffraction, Raman spectroscopy, and atomic force microscopy. The dependence of the deposition rate, film density, elemental composition, self-bias and residual stress is reported as a function of RF power. Higher density films were found when using Ar plasma, than N 2 or H 2 plasma. The coatings produced are x-ray amorphous, exhibit low compressive stress ( ~ 100 MPa), high density ( < 1.7 g/cm 3 ), hydrogen content of ~ 30 at.%, and a low average roughness of 0.75 nm. Finally, applications of these films as tunable-density ablators for inertial confinement fusion experiments are discussed.

36 MATERIALS SCIENCE↗

Spectro-temporal comparisons of optical emission, absorption, and laser-induced fluorescence for characterizing ns and fs laser-produced plasmas

We performed simultaneous measurement of absorption, emission, and laser-induced fluorescence spectroscopic signatures for determining nanosecond and femtosecond laser-produced plasma’s physical properties throughout its lifecycle. Plasmas are produced by focusing either ~6 ns, 1064 nm pulses from an Nd:YAG or ~35 fs, ~800 nm pulses from a Ti:Sapphire laser on an Inconel target that contains Al as a minor alloying addition. A continuous-wave narrowband tunable laser was used for performing absorption and fluorescence spectroscopy while a fast-gated detection system was used for emission spectroscopy. The temporal evolution of emission, fluorescence, and absorbance of Al transitions are compared for both ns and fs laser-produced plasms. Time-resolved absorbance was also used for evaluating linewidth, lineshape, temperature, and column-averaged atomic number density at late times of ns and fs plasma evolution. Our results demonstrate that lower and excited-state populations of fs laser produced plasmas are short-lived in comparison to those in ns plasmas. The lower state population is observed to reach a maximum value earlier in time for the fs plasma versus the ns plasma, while the kinetic temperature for the ns plasma was higher than for the fs plasma at most times of the plasma evolution.

(280.4788) Optical Sensing, (300.2140) Emission Sp↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-shot local measurement of terahertz correlated second harmonic generation in laser air plasma filaments

We present a single-shot detection method of terahertz correlated second harmonic generation in plasma-based sources by directly mixing an optical probe into femtosecond laser-induced plasma filaments in air. Furthermore, the single-shot second harmonic trace is obtained by measuring a second harmonic generation on a conventional CCD with a spatiotemporally distorted probe beam. The system shows a spectrometer resolution of 22 fs/pixel on the CCD and a true resolution on the order of the probe pulse duration. With considerable THz peak electric field strength, this formalism can open the door to single-shot THz detection without bandwidth limitations.

47 OTHER INSTRUMENTATION↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Influence of liquid conductance on the temporal evolution of self-organization patterns in atmospheric pressure DC glow discharges

Abstract Self-Organized Patterns (SOPs) at plasma-liquid interface in atmospheric pressure plasma discharges refer to the formation of intricate and puzzling structures due to the interplay of electrodynamic and hydrodynamic processes. Studies conducted to date have shown that this phenomenon results in the formation of distinctive patterns such as circular ring, star, gear, dots, spikes, etc., and primarily depends on working gas, electrolyte type, gap distance, current, conductivity, etc. However, an adequate understanding of how these patterns change from one type to another is still not available. This study aims to elucidate the influence of initial liquid conductance ( σ i ) on the temporal evolution of SOPs in liquid-anode discharges. The discharge was generated in a pin-to-liquid anode configuration at a constant helium (He) flow rate of 500 sccm and DC applied voltage of 6 kV at a gap distance of 12 mm. Through the gradual increment of σ i from 1.8 μ S to 4820 μ S, we observe that the trend in the evolution of SOPS takes place as solid discs, spikes, dots, rings, double rings, and stars. The continuous formation of reactive species onto the liquid anode in all conductive solutions results in a decrease in pH, an increase in bulk liquid temperature, and an increase in total dissolved solutes, and these have been confirmed through experimental measurements. Observations using optical emission spectroscopy show that the electrons at the plasma-liquid interface participate in the reduction of cations followed by their excitation & ionization due to which electron density as well as emissions from excited species (mainly hydroxyl radicals & excited nitrogen) decrease with time. Our investigation provides experimental evidence on the presence of cations at the plasma-liquid interface required for SOP formation.

Physics↗

Rapid retrieval of first-order spatiotemporal distortions for ultrashort laser pulses

High-intensity, ultrashort laser sources are a foundational pillar for High-Energy-Density (HED) physics, and as the repetition-rates of these systems increase, diagnostics must be developed to match their data collection speed. Characterization of any spatiotemporal distortions in the laser pulse is necessary in order to standardize results across facilities. Here, we have previously developed a laser diagnostic called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, or STRIPED FISH, to measure the full spatiotemporal laser electric field on a single shot. In order to provide rapid feedback, we here adapt the STRIPED FISH retrieval algorithm, which typically has computation times of up to 30 minutes due to the high spatial resolution of the device and its retrieval of the complete four-dimensional pulse field, to distill the key electric field quantities into a handful of scalars for rapid assessment of the pulse's first order distortions. Here, our new, rapid non-iterative retrieval algorithm is validated with simulated and experimental data, and it provides, within seconds, the same first-order information as given by the full analysis. This algorithm is suitable for on-shot assessment of spatiotemporal distortions and can be adapted to assess high repetition-rate laser quality in HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A near X-point charge exchange neutral spectroscopy (CENS) system for DIII-D

A 16 channel spectroscopy system has been installed on DIII-D to provide information about the energy distribution of the atomic neutrals using the Doppler shift and broadening of passive Balmer-α emission. Here, the lines of sight are dominantly in the toroidal direction, with tangencies near the lowest point on closed magnetic flux surfaces moving from the lower divertor upward into the confined plasma. This allows the system to provide details of the neutrals as they undergo various atomic physics processes while traveling upward from the lower divertor. The spectrally resolved measurements provide several advantages that complement typical optical filter based measurements of hydrogenic spectral lines. These include more direct measurements of the neutrals that fuel deeper in the plasma and capturing neutral velocity distribution information via the Doppler broadened and shifted line. In addition, the spectral separation of higher energy “thermal” neutrals and bright cold emission from the scrape-off layer allows for a more straightforward calculation of the underlying neutral densities based on the emission because of the dependence of the thermal emission on confined plasma properties that are approximately flux functions and well measured.

Atomic and molecular physics↗