Search NASA⌕ Search

SEARCH · Search NASA

Results for “PATIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes, mediastinal lymph nodes, and unsuspected sites of distant metastasis. This information is important in the design of radiotherapy treatment fields and, therefore, we recommend that PET/CT be a component of initial staging for IBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity Modulated Radiation Therapy With Simultaneous Integrated Boost in Patients With Brain Oligometastases: A Phase 1 Study (ISIDE-BM-1)

Purpose: To investigate the maximum tolerated dose of intensity modulated radiation therapy simultaneous integrated boost whole-brain radiation therapy for palliative treatment of patients with <5 brain metastases using a standard linear accelerator. Materials and Methods: The whole brain plus 3-mm margin was defined as the planning target volume (PTV{sub wb}), whereas each brain metastasis, defined as the contrast-enhancing tumor on MRI T1 scans, plus a 3-mm isotropic margin, was defined as metastases PTV (PTV{sub m}). Radiation therapy was delivered in 10 daily fractions (2 weeks). Only the dose to PTV{sub m} was progressively increased in the patient cohorts (35 Gy, 40 Gy, 45 Gy, 50 Gy), whereas the PTV{sub wb} was always treated with 30 Gy (3 Gy per fraction) in all patients. The dose-limiting toxicity was evaluated providing that 3 months of follow-up had occurred after the treatment of a 6-patient cohort. Results: Thirty patients were enrolled in the study (dose PTV{sub m}: 35 Gy, 8 patients; 40 Gy, 6 patients; 45 Gy, 6 patients; 50 Gy, 10 patients). The number of treated brain metastases was 1 in 18 patients, 2 in 5 patients, 3 in 6 patients, and 4 in 1 patient. Three patients experienced dose-limiting toxicity: 1 patient at dose level 2 presented grade 3 (G3) skin toxicity; 1 patient at dose level 4 presented G3 neurologic toxicity; and 1 patient at the same level showed brain hemorrhage. Most patients showed G1 to 2 acute toxicity, in most cases skin (n=19) or neurologic (n=10). Twenty-seven were evaluable for response: 6 (22%) stable disease, 18 (67%) partial response, and 3 (11%) complete response. Median survival and 1-year overall survival were 12 months and 53%, respectively. No patient showed late toxicity. Conclusions: In this first prospective trial on the use of intensity modulated radiation therapy simultaneous integrated boost delivered with a standard linear accelerator in patients with brain oligometastases, a boost dose up to 50 Gy in 10 fractions was tolerable according to the study design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Guided Hypofractionated 3-Dimensional Radiation Therapy in Patients With Inoperable Advanced Stage Non-Small Cell Lung Cancer

Purpose: Hypofractionated radiation therapy (HypoRT) can potentially improve local control with a higher biological effect and shorter overall treatment time. Response, local control, toxicity rates, and survival rates were evaluated in patients affected by inoperable advanced stage non-small cell lung cancer (NSCLC) who received HypoRT. Methods and Materials: Thirty patients with advanced NSCLC were enrolled; 27% had stage IIIA, 50% had stage IIIB, and 23% had stage IV disease. All patients underwent HypoRT with a prescribed total dose of 60 Gy in 20 fractions of 3 Gy each. Radiation treatment was delivered using an image guided radiation therapy technique to verify correct position. Toxicities were graded according to Radiation Therapy Oncology Group morbidity score. Survival rates were estimated using the Kaplan-Meier method. Results: The median follow-up was 13 months (range, 4-56 months). All patients completed radiation therapy and received the total dose of 60 Gy to the primary tumor and positive lymph nodes. The overall response rate after radiation therapy was 83% (3 patients with complete response and 22 patients with partial response). The 2-year overall survival and progression-free survival rates were 38.1% and 36%, respectively. Locoregional recurrence/persistence occurred in 11 (37%) patients. Distant metastasis occurred in 17 (57%) patients. Acute toxicities occurred consisting of grade 1 to 2 hematological toxicity in 5 patients (17%) and grade 3 in 1 patient; grade 1 to 2 esophagitis in 12 patients (40%) and grade 3 in 1 patient; and grade 1 to 2 pneumonitis in 6 patients (20%) and grade 3 in 2 patients (7%). Thirty-three percent of patients developed grade 1 to 2 late toxicities. Only 3 patients developed grade 3 late adverse effects: esophagitis in 1 patient and pneumonitis in 2 patients. Conclusions: Hypofractionated curative radiation therapy is a feasible and well-tolerated treatment for patients with locally advanced NSCLC. Randomized studies are needed to compare HypoRT to conventional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The impact of anthropometric patient-phantom matching on organ dose: A hybrid phantom study for fluoroscopy guided interventions

Purpose: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions. Methods: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific and patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference. Results: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections. Conclusions: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences. For large patients, difference in soft tissue attenuation can be large. In these cases, patient-phantom matching proves most effective as differences in soft tissue attenuation are mitigated. With increasing obesity rates, overweight patients will continue to make up a growing fraction of all patients undergoing medical imaging. Thus, having phantoms that better represent this population represents a considerable improvement over previous methods. In response to this study, additional phantoms representing heavier weight percentiles will be added to the UFHADM and UFHADF patient-dependent series.

60 APPLIED LIFE SCIENCES↗

Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA

Purpose: The purpose of this work is to explore the usefulness of the gamma passing rate metric for per-patient, pretreatment dose QA and to validate a novel patient-dose/DVH-based method and its accuracy and correlation. Specifically, correlations between: (1) gamma passing rates for three 3D dosimeter detector geometries vs clinically relevant patient DVH-based metrics; (2) Gamma passing rates of whole patient dose grids vs DVH-based metrics, (3) gamma passing rates filtered by region of interest (ROI) vs DVH-based metrics, and (4) the capability of a novel software algorithm that estimates corrected patient Dose-DVH based on conventional phan-tom QA data are analyzed. Methods: Ninety six unique ''imperfect'' step-and-shoot IMRT plans were generated by applying four different types of errors on 24 clinical Head/Neck patients. The 3D patient doses as well as the dose to a cylindrical QA phantom were then recalculated using an error-free beam model to serve as a simulated measurement for comparison. Resulting deviations to the planned vs simulated measured DVH-based metrics were generated, as were gamma passing rates for a variety of difference/distance criteria covering: dose-in-phantom comparisons and dose-in-patient comparisons, with the in-patient results calculated both over the whole grid and per-ROI volume. Finally, patient dose and DVH were predicted using the conventional per-beam planar data as input into a commercial ''planned dose perturbation'' (PDP) algorithm, and the results of these predicted DVH-based metrics were compared to the known values. Results: A range of weak to moderate correlations were found between clinically relevant patient DVH metrics (CTV-D95, parotid D{sub mean}, spinal cord D1cc, and larynx D{sub mean}) and both 3D detector and 3D patient gamma passing rate (3%/3 mm, 2%/2 mm) for dose-in-phantom along with dose-in-patient for both whole patient volume and filtered per-ROI. There was considerable scatter in the gamma passing rate vs DVH-based metric curves. However, for the same input data, the PDP estimates were in agreement with actual patient DVH results. Conclusions: Gamma passing rate, even if calculated based on patient dose grids, has generally weak correlation to critical patient DVH errors. However, the PDP algorithm was shown to accurately predict the DVH impact using conventional planar QA results. Using patient-DVH-based metrics IMRT QA allows per-patient dose QA to be based on metrics that are both sensitive and specific. Further studies are now required to analyze new processes and action levels associated with DVH-based metrics to ensure effectiveness and practicality in the clinical setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase I Trial of Bortezomib and Concurrent External Beam Radiation in Patients With Advanced Solid Malignancies

Purpose: To determine the maximal tolerated dose of bortezomib with concurrent external beam radiation therapy in patients with incurable solid malignant tumors requiring palliative therapy. Methods and Materials: An open label, dose escalation, phase I clinical trial evaluated the safety of three dose levels of bortezomib administered intravenously (1.0 mg/m{sup 2}, 1.3 mg/m{sup 2}, and 1.6 mg/m{sup 2}/ dose) once weekly with concurrent radiation in patients with histologically confirmed solid tumors and a radiographically appreciable lesion suitable for palliative radiation therapy. All patients received 40 Gy in 16 fractions to the target lesion. Dose-limiting toxicity was the primary endpoint, defined as any grade 4 hematologic toxicity, any grade {>=}3 nonhematologic toxicity, or any toxicity requiring treatment to be delayed for {>=}2 weeks. Results: A total of 12 patients were enrolled. Primary sites included prostate (3 patients), head and neck (3 patients), uterus (1 patient), abdomen (1 patient), breast (1 patient), kidney (1 patient), lung (1 patient), and colon (1 patient). The maximum tolerated dose was not realized with a maximum dose of 1.6 mg/m{sup 2}. One case of dose-limiting toxicity was appreciated (grade 3 urosepsis) and felt to be unrelated to bortezomib. The most common grade 3 toxicity was lymphopenia (10 patients). Common grade 1 to 2 events included nausea (7 patients), infection without neutropenia (6 patients), diarrhea (5 patients), and fatigue (5 patients). Conclusions: The combination of palliative external beam radiation with concurrent weekly bortezomib therapy at a dose of 1.6 mg/m{sup 2} is well tolerated in patients with metastatic solid tumors. The maximum tolerated dose of once weekly bortezomib delivered concurrently with radiation therapy is greater than 1.6 mg/m{sup 2}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involved-Node Radiotherapy and Modern Radiation Treatment Techniques in Patients With Hodgkin Lymphoma

Purpose: To assess the clinical outcome of the involved-node radiotherapy (INRT) concept using modern radiation treatments (intensity-modulated radiotherapy [IMRT]or deep-inspiration breath-hold radiotherapy [DIBH) in patients with localized supradiaphragmatic Hodgkin lymphoma. Methods and Materials: All but 2 patients had early-stage Hodgkin lymphoma, and they were treated with chemotherapy prior to irradiation. Radiation treatments were delivered using the INRT concept according to European Organization for Research and Treatment of Cancer guidelines. IMRT was performed with the patient free-breathing. For the adapted breath-hold technique, a spirometer dedicated to DIBH radiotherapy was used. Three-dimensional conformal radiotherapy was performed with those patients. Results: Fifty patients with Hodgkin lymphoma (48 patients with primary Hodgkin lymphoma, 1 patient with recurrent disease, and 1 patient with refractory disease) entered the study from January 2003 to August 2008. Thirty-two patients were treated with IMRT, and 18 patients were treated with the DIBH technique. The median age was 28 years (range, 17-62 years). Thirty-four (68%) patients had stage I - (I-IIA) IIA disease, and 16 (32%) patients had stage I - (I-IIB) IIB disease. All but 3 patients received three to six cycles of adriamycin, bleomycin, vinblastine, and dacarbazine (ABVD). The median radiation doses to patients treated with IMRT and DIBH were, respectively, 40 Gy (range, 21.6-40 Gy) and 30.6 Gy (range, 19.8-40 Gy). Protection of various organs at risk was satisfactory. Median follow-up was 53.4 months (range, 19.1-93 months). The 5-year progression-free and overall survival rates for the whole population were 92% (95% confidence interval [CI], 80%-97%) and 94% (95% CI, 75%-98%), respectively. Recurrences occurred in 4 patients: 2 patients had in-field relapses, and 2 patients had visceral recurrences. Grade 3 acute lung toxicity (transient pneumonitis) occurred in 1 case. Conclusions: Our results suggest that patients with localized Hodgkin lymphoma can be safely and efficiently treated using the INRT concept and modern radiation treatment techniques such as IMRT and DIBH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes in patients ≥ 80 years with a diagnosis of a hepatopancreaticobiliary (HPB) malignancy

Older patients are underrepresented in oncological clinical trials. The incidence of hepatopancreaticobiliary (HPB) malignancies is higher in older patients, but data on outcomes are lacking. This study assessed patient outcomes in those < 80 and ≥ 80 years with a HPB malignancy seen at a tertiary referral centre, The Christie NHS Foundation Trust. Data on patients with a HPB malignancy were collected retrospectively between 2012 and 2017 via on-line case-note review. Survival was calculated using the Kaplan–Meier method and prognostic factors using log-rank analysis. Of 1421 patients, 10% were ≥ 80 years. Of patients < 80 and ≥ 80 years, 56% and 57% had pancreas cancer, 39% and 36% biliary tract cancer, and 5% and 7% had hepatocellular carcinoma, respectively. Amongst patients ≥ 80 years, 75% had an Eastern Cooperative Oncology Group performance status (ECOG PS) 0–2. Patients ≥ 80 years had higher rates of comorbidity; 28% received systemic anti-cancer therapy (SACT), compared with 62% of patients < 80 years. Best supportive care (BSC) was instituted in 44% of older patients, compared with 13% in those < 80 years. Of patients ≥ 80 years who received SACT, 82% received monotherapy. Median overall survival (OS) for patients receiving palliative SACT was 10.07 months (95% CI 8.89–11.08) and 10.10 months (95% CI 6.30–12.30) in patients < 80 and ≥ 80 years, respectively, p 0.41; ECOG PS (p < 0.001) was prognostic for OS in older patients but Adult Comorbidity Evaluation-27 comorbidity score (p = 0.07, when comparing groups of ACE score ≤ 1 and > 1) was not. Baseline factors were similar in both age cohorts, but more comorbidities were present in older patients. Older patients were less likely to receive SACT, but when they did, they had an equivalent benefit in OS to younger patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Treatment of Primary Glioblastoma Multiforme With Radiation and Concomitant Temozolomide in Elderly Patients

Purpose: To evaluate efficacy and toxicity in elderly patients with glioblastoma multiforme (GBM) treated with postoperative radiochemotherapy with temozolomide (TMZ). Patients and Methods: Forty-three patients aged 65 years or older were treated with postoperative with radiochemotherapy using TMZ for primary GBM. Median age at primary diagnosis was 67 years; 14 patients were female, 29 were male. A complete surgical resection was performed in 12 patients, subtotal resection in 17 patients, and biopsy only in 14 patients. Radiotherapy was applied with a median dose of 60 Gy, in a median fractionation of 5 x 2 Gy/wk. Thirty-five patients received concomitant TMZ at 50 mg/m{sup 2}, and in 8 patients 75 mg/m{sup 2} of TMZ was applied. Adjuvant cycles of TMZ were prescribed in 5 patients only. Results: Median overall survival was 11 months in all patients; the actuarial overall survival rate was 48% at 1 year and 8% at 2 years. Median overall survival was 18 months after complete resection, 16 months after subtotal resection, and 6 months after biopsy only. Median progression-free survival was 4 months; the actuarial progression-free survival rate was 41% at 6 months and 18% at 12 months. Radiochemotherapy was well tolerated in most patients and could be completed without interruption in 38 of 43 patients. Four patients developed hematologic side effects greater than Common Terminology Criteria Grade 2, which led to early discontinuation of TMZ in 1 patient. Conclusions: Radiochemotherapy is safe and effective in a subgroup of elderly patients with GBM and should be considered in patients without major comorbidities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Androgen Deprivation Therapy Necessary in All Intermediate-Risk Prostate Cancer Patients Treated in the Dose Escalation Era?

Purpose: The benefit of adding androgen deprivation therapy (ADT) to dose-escalated radiation therapy (RT) for men with intermediate-risk prostate cancer is unclear; therefore, we assessed the impact of adding ADT to dose-escalated RT on freedom from failure (FFF). Methods: Three groups of men treated with intensity modulated RT or 3-dimensional conformal RT (75.6-78 Gy) from 1993-2008 for prostate cancer were categorized as (1) 326 intermediate-risk patients treated with RT alone, (2) 218 intermediate-risk patients treated with RT and ≤6 months of ADT, and (3) 274 low-risk patients treated with definitive RT. Median follow-up was 58 months. Recursive partitioning analysis based on FFF using Gleason score (GS), T stage, and pretreatment PSA concentration was applied to the intermediate-risk patients treated with RT alone. The Kaplan-Meier method was used to estimate 5-year FFF. Results: Based on recursive partitioning analysis, intermediate-risk patients treated with RT alone were divided into 3 prognostic groups: (1) 188 favorable patients: GS 6, ≤T2b or GS 3+4, ≤T1c; (2) 71 marginal patients: GS 3+4, T2a-b; and (3) 68 unfavorable patients: GS 4+3 or T2c disease. Hazard ratios (HR) for recurrence in each group were 1.0, 2.1, and 4.6, respectively. When intermediate-risk patients treated with RT alone were compared to intermediate-risk patients treated with RT and ADT, the greatest benefit from ADT was seen for the unfavorable intermediate-risk patients (FFF, 74% vs 94%, respectively; P=.005). Favorable intermediate-risk patients had no significant benefit from the addition of ADT to RT (FFF, 94% vs 95%, respectively; P=.85), and FFF for favorable intermediate-risk patients treated with RT alone approached that of low-risk patients treated with RT alone (98%). Conclusions: Patients with favorable intermediate-risk prostate cancer did not benefit from the addition of ADT to dose-escalated RT, and their FFF was nearly as good as patients with low-risk disease. In patients with GS 4+3 or T2c disease, the addition of ADT to dose-escalated RT did improve FFF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 2 Trial of Induction Gemcitabine, Oxaliplatin, and Cetuximab Followed by Selective Capecitabine-Based Chemoradiation in Patients With Borderline Resectable or Unresectable Locally Advanced Pancreatic Cancer

Purpose: To evaluate, in a phase 2 study, the safety and efficacy of induction gemcitabine, oxaliplatin, and cetuximab followed by selective capecitabine-based chemoradiation in patients with borderline resectable or unresectable locally advanced pancreatic cancer (BRPC or LAPC, respectively). Methods and Materials: Patients received gemcitabine and oxaliplatin chemotherapy repeated every 14 days for 6 cycles, combined with weekly cetuximab. Patients were then restaged; “downstaged” patients with resectable disease underwent attempted resection. Remaining patients were treated with chemoradiation consisting of intensity modulated radiation therapy (54 Gy) and concurrent capecitabine; patients with borderline resectable disease or better at restaging underwent attempted resection. Results: A total of 39 patients were enrolled, of whom 37 were evaluable. Protocol treatment was generally well tolerated. Median follow-up for all patients was 11.9 months. Overall, 29.7% of patients underwent R0 surgical resection (69.2% of patients with BRPC; 8.3% of patients with LAPC). Overall 6-month progression-free survival (PFS) was 62%, and median PFS was 10.4 months. Median overall survival (OS) was 11.8 months. In patients with LAPC, median OS was 9.3 months; in patients with BRPC, median OS was 24.1 months. In the group of patients who underwent R0 resection (all of which were R0 resections), median survival had not yet been reached at the time of analysis. Conclusions: This regimen was well tolerated in patients with BRPC or LAPC, and almost one-third of patients underwent R0 resection. Although OS for the entire cohort was comparable to that in historical controls, PFS and OS in patients with BRPC and/or who underwent R0 resection was markedly improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗