86 records · Page 5

Ionomer-free nanoporous iridium nanosheet electrodes with boosted performance and catalyst utilization for high-efficiency water electrolyzers

Increasing the catalyst utilization efficiency and simplifying electrode fabrication processes are crucial to accelerate development of low-cost proton exchange membrane electrolyzer cells (PEMECs). Here, we develop a facile route to fabricate ionomer-free iridium nanosheet integrated electrodes, in which nanoporous iridium nanosheets (IrNS) with abundant exposed edges and nanopores are deposited on thin titanium liquid/gas diffusion layers (TT-LGDLs) via a low-temperature chemical synthesis strategy. Further, benefiting from high catalytic activity, good electrode conductivity and excellent liquid/gas transport properties, such nanoporous IrNS electrodes with low catalyst loadings require low cell voltages of 1.65 V and 1.78 V at 3000 and 6000 mA/cm 2 , respectively. More impressively, a stable performance can be well maintained under extremely high current density tests of 5000 mA/cm 2 , demonstrating the potential of low-loading nanoporous IrNS electrodes in solid-electrolyte based electrochemical conversion cells that require high current density operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MW-Scale PEM-Based Electrolyzers for RES Applications (CRADA CRD-18-00742 Final Report)

Many nations are rapidly increasing electrical generation capacity from renewable energy sources (RES) such as wind and solar. The wide penetration of RES requires an energy storage solution which has come in the form of hydrogen generated via polymer exchange membrane (PEM) electrolysis. A study of the current state-of-the-art PEM electrolysis indicates that the largest PEM-based stacks range from 150 - 250kW and that a significant scale-up of the technology is required to accommodate multi-Megawatt (MW) energy storage solutions in large-scale RES applications.

08 HYDROGEN↗

HydroGEN and H2NEW Data Hub

HydroGEN is a multi-lab consortium focused on early-stage R&D in H2 production, supported by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Hydrogen and Fuel Cell Technologies Office (HFTO). The consortium advances research and development (R&D) of innovative materials for advanced water splitting (AWS) technologies to enable clean, sustainable and low-cost ($1/kg H2) hydrogen production and fosters cross-cutting innovation using theory-guided applied materials R&D to advance all emerging water-splitting pathways for hydrogen production. Hydrogen from Next-generation Electrolyzers of Water (H2NEW) is a consortium of nine U.S. Department of Energy (DOE) national laboratories focused on making large-scale electrolyzers, which produce hydrogen from electricity and water, more durable, efficient, and affordable. The presentation introduces the HydroGEN data hub to the H2NEW consortium and encourages H2NEW members to use it to store and share data with team members and eventually the public. The two consortia share this data hub.

advanced water splitting technologies↗

Renewable Electrolysis System Development (Final Report)

Renewable hydrogen is becoming globally recognized as a key component required for de-carbonization of our energy system, both as a medium for capture of excess renewable energy sources, vehicle refueling, and as an intermediate for multiple industrial processes. Hydrogen production, via low-temperature electrolysis, is a flexible grid-friendly, clean energy carrying intermediate that enables fast ramp and de-ramp rates as naturally varying solar, wind, and storage systems become a larger percentage of the electricity mix. Analysis shows that by 2050, employing renewable hydrogen at scale can decrease total U.S. CO 2 emissions by about half relative to business as usual, critical to achieving >80% greenhouse gas reduction targets. Energy storage systems help commercial customers reduce their electric bills by storing energy from the grid or from renewable electricity sources when energy is inexpensive, then using that stored energy when demand and prices are high. Proton exchange membrane (PEM) electrolysis is one of the few technologies that can produce hydrogen with zero carbon emissions at relevant scale (hundreds of MWs) in the near term. NREL's research has shown that electrolyzers are fast and flexible enough to participate in energy and ancillary service markets that can help stabilize the grid. In 2015, Proton OnSite (now NEL Hydrogen) introduced the M-series electrolyzer platform, the world's first megawatt PEM electrolyzer for the global energy storage market, offering a carbon-free source of hydrogen fuel or process gas. In addition, the ability to sell the hydrogen into a high value application like vehicle (e.g., light- and heavy-duty and material handling) fueling allows for a layering of revenue streams that creates better business cases for hydrogen energy storage systems (HES). The ability to provide multiple value streams from the fast-responding controllable electrolyzer will have a direct impact on the net cost of hydrogen.

08 HYDROGEN↗

Using X-ray radiography to study oxygen flow in a proton exchange membrane electrolyzer operating under balanced pressure conditions

Of the various water electrolyzer technologies, the proton exchange membrane electrolyzer (PEMWE) is one of the best solutions for producing clean hydrogen without releasing CO 2 . In order to allow for widespread use of clean hydrogen, it is necessary to decrease its cost, which is intrinsically related to system operation. Current PEMWE plants operate in differential mode, directly pressurizing hydrogen and benefiting from thermodynamic compression, which increases overall system efficiency. However, high differential pressure above 30 bar can cause membrane stress, resulting in membrane creeping and failure. Pressurizing the water and operating at balanced pressure allows hydrogen to be produced at higher pressures while preserving the integrity of the membrane and porous layers. Nevertheless, the impact of pressurizing water on PEMWE performance must be better understood to maximize performance under balanced pressure conditions. Here, this study examined the impact of water pressure on two-phase flow. A high-pressure electrolyzer setup was developed to perform operando X-ray radiography and examine oxygen transport with high temporal resolution. The imaging segmentation process, developed to capture bubble properties in the channel, was applied to a specific experiment. The results clearly showed that as pressure increased up to 30 bars, the initial bubbly flow transitioned to slug flow, which led to channel saturation with oxygen. This work demonstrates that two-phase flow in an electrolyzer can be studied using X-ray radiography, which has the advantages of fast measurements and the ability to probe dense materials, such as those required for pressurized electrolyzers.

Balanced high pressure operation↗

Design of non-fluorinated proton exchange membranes from Poly(Terphenyl fluorenyl isatin) with fluorene-linked sulfonate groups and microblock structures

Proton exchange membranes (PEMs) are essential components in energy storage and conversion devices, such as fuel cells and electrolyzers. Here, in this study, we developed a series of non-fluorinated PEMs from poly(terphenyl fluorenyl isatin) with fluorene-pendent disulfonate groups. These polymers feature a microblock structure composed of hydrophobic blocks, hydrophilic blocks, and alternating blocks, arising from the differences in reactivity, concentration, and solubility between the hydrophobic p-terphenyl and hydrophilic disulfonated fluorene monomers. As a result, the sulfonic acid groups are unevenly distributed along the polymer chains, forming densely charged regions (IEC = 3.52 meq/g) with large ion clusters and lightly charged regions (IEC = 2.16 meq/g) with small ion clusters. This microstructure, combined with the degree of sulfonation, significantly influences the overall properties of the membranes, including robust mechanical strength (47.1–63.2 MPa), high thermal stability (up to 270 °C), low swelling ratio (18–25% at 80 °C), and high proton conductivity (136–169 mS/cm in deionized water at 80 °C). The PFLSH60 membrane demonstrated comparable fuel cell performance to Nafion 212. Its hydrogen crossover current density was more than two times lower (0.86 mA/cm 2 for PFLSH60 compared to 1.83 mA/cm 2 for Nafion 212) under testing conditions of 80 °C and 100% RH. This significantly reduced crossover improves fuel utilization in fuel cell stacks. This work offers valuable insights into the design of robust, high-performance PEMs by systematically analyzing the relationships between membrane structure, properties, and performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical Prediction and Experimental Verification of IrO x Supported on Titanium Nitride for Acidic Oxygen Evolution Reaction

Reducing iridium (Ir) catalyst loading for acidic oxygen evolution reaction (OER) is a critical strategy for large-scale hydrogen production via proton exchange membrane (PEM) water electrolysis. However, simultaneously achieving high activity, long-term stability, and reduced material cost remains challenging. To address this challenge, we develop a frame-work by combining density functional theory (DFT) prediction using model surfaces and proof-of-concept experimental ver-ification using thin films and nanoparticles. DFT results predict that oxidized Ir monolayers over titanium nitride (IrO x /TiN) should display higher OER activity than IrO x while reducing Ir loading. Further, this prediction is verified by depositing Ir monolayers over TiN thin films via physical vapor deposition. The promising thin film results are then extended to commercially viable powder IrO x /TiN catalysts, which demonstrate a lower overpotential and higher mass activity than commercial IrO 2 , and a long-term stability of 250 hours to maintain a current density of 10 mA cm -2 . The superior OER performance of IrO x /TiN is further confirmed using proton exchange membrane water electrolyzer (PEMWE), which shows a lower cell voltage than commercial IrO 2 to achieve a current density of 1 A cm -2 . Both DFT and in situ X-ray absorption spectroscopy reveal that the high OER performance of IrO x /TiN strongly depends on the IrO x - TiN interaction via direct Ir-Ti bonding. This study highlights the importance of close interaction between theoretical prediction based on mechanistic understanding and experimental verification based on thin film model catalysts to facilitate the development of more practical powder IrO x /TiN catalysts with high activity and stability for acidic OER.

08 HYDROGEN↗

Updated Manufactured Cost Analysis for Proton Exchange Membrane Water Electrolyzers

Enabling rapid and extensive decarbonization within the electric power and industrial sectors is likely to require high levels of renewable energy deployment, supported by technologies that store and transform renewable electricity into other useful forms. Within hard to decarbonize sectors such as organic chemicals and heavy-duty transportation, the use of low-carbon intensity hydrogen as a fuel and chemical building block is emerging as a near-term alternative to reduce their fossil-fuel dependency. Water splitting electrolysis to produce hydrogen requires only water and electricity as inputs, eliminating the use of natural gas in steam methane reforming, which is the conventional hydrogen production pathway. When powered by low-carbon electricity, electrolysis represents an important pathway towards cross-sectoral decarbonization.

08 HYDROGEN↗

Life-cycle analysis of hydrogen production from water electrolyzers

The United States' focus on decarbonization has spawned interest among policymakers in deploying water electrolysis technology for clean hydrogen production. However, water electrolyzers also raise concerns regarding their substantial use of carbon-intensive materials. Here, we conduct a comprehensive life-cycle analysis (LCA) of three prominent water electrolyzer technologies to investigate the environmental implications of their manufacturing and life cycles under different energy sources. All electrolyzer technologies employing low-carbon energy (nuclear, solar, or wind) exhibit life-cycle greenhouse gas (GHG) emissions of 0.3-2.4 kg-CO 2-eq /kg-H 2 . This is significantly lower than the corresponding GHG emissions for hydrogen production via both conventional steam methane reforming and alternative autothermal reforming with carbon capture and storage (by > 50%). The well-to-gate GHG emissions of low-carbon electrolyzers (0-0.36 kg-CO 2-eq / kg-H 2 ) qualify for Tier I of the production tax credit in the U.S.' Inflation Reduction Act of 2022, indicating their suitability for producing decarbonized hydrogen under this program.

08 HYDROGEN↗

Integrating Solar Energy, Desalination, and Electrolysis

Solar electricity enables the advancement and deployment of technologies that are strongly influenced by clean energy availability and cost. The economics of both desalination and hydrogen production from water electrolysis are dominated by the cost of energy, and the availability of inexpensive solar energy creates markets and offers incentives to the desalination and electrolyzer industries. In this report the production of high-purity water and hydrogen from seawater is focused on. Current electrolyzers require deionized water so they need to be coupled with desalination units. It is shown that such coupling is cost effective in hydrogen generation, and it also offers benefits to thermal desalination, which can utilize waste heat from electrolysis. Furthermore, such coupling can be optimized when electrolyzers operate at high current density, using low-cost solar and/or wind electricity, as such operation increases both hydrogen production and heat generation. Results of technoeconomic modeling of polymer electrolyte membrane electrolyzers define thresholds of electricity pricing, current density, and operating temperature that make clean electrolytic hydrogen cost competitive with hydrogen from steam methane reforming (SMR). By using 2020 hourly electricity pricing in California and Texas, it is estimated that hydrogen can be produced from seawater in coupled desalination-electrolyzer systems at prices near $2 kg -1 H 2 , reaching cost parity with hydrogen produced from SMR.

14 SOLAR ENERGY↗

Performance improvement of proton exchange membrane water electrolysis by surface modification of porous transport layers

Proton exchange membrane water electrolysis (PEMWE) is a promising option for hydrogen production from a variety of energy sources. Cost-effective production of hydrogen with PEMWE requires reduction of costly precious metals as well as optimization of the components and interfaces in the cell. The interface between the platinum-coated titanium porous transport layer (PTL) and catalyst layer (CL) significantly impacts the performance of the electrolyzer cell. Here, we report on two PTL modification methods, mechanical abrasion and chemical etching, which we find improve PEMWE performance by lowering the resistance of the PTL/CL interface. The PTL surface modifications enabled performance improvements up to 77 mV at 4 A cm −2 and reduction of the high frequency resistance, demonstrating that the resistance of the PTL/CL interface is a significant factor in the cell performance. The PTL surface roughness was varied using abrasive materials ranging from 0.1 to 140 μm in grain sizes and chemical etching was found to also increase the surface roughness. The surface roughness was quantified using confocal laser microscopy and the surface oxidation was measured using X-ray photoemission spectroscopy. These results demonstrate that both increasing surface roughness and oxide removal contribute to lowering the PTL/CL interfacial resistance and increasing cell performance.

08 HYDROGEN↗

Quantifying Sources of Voltage Decay in Long-Term Durability Testing for PEM Water Electrolysis

Meeting a competitive 1$/kg hydrogen cost target for polymer electrolyte membrane water electrolysis (PEMWE) will require advances to significantly reduce capital costs and precious metal catalyst usage, while simultaneously enabling 40,000–80,000 h stack lifetimes under dynamic use conditions. Minimizing cell voltage decay rates is therefore a key goal for PEMWE, although the fundamental processes governing voltage decay are not yet well understood. Here we present a quantitative approach to analyze the contributions to voltage decay in long-term PEMWE testing using polarization curves, impedance spectroscopy, and post-mortem electron microscopy. We apply this approach to analyze a 28 μV h −1 decay rate observed in a 4000 h durability test of a cell using 0.5 mg cm −2 total PGM catalyst loading (0.4 mg Ir cm −2 anode, 0.1 mg Pt cm −2 cathode) and 3 A cm −2 current density. We also analyze a comparative series of 1000 h tests under different conditions. These results provide valuable insights into anode catalyst degradation processes, as well as transferrable methodology for PEMWE durability research.

08 HYDROGEN↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗