Search NASASearch

SEARCH · Search NASA

Results for “PERFORMANCE CHARACTERISTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

503 records · Page 5

Impact of the Annealing Temperature on the Local Se Distribution and Optical Properties in CdSexTe1-x Solar Cells by Multimodal X-ray Microscopy

The introduction of Se in CdTe solar-cell absorbers has led to multiple beneficial effects in the devices, including an increased short-circuit current and an extended charge-carrier lifetime. A critical manufacturing step of CdSexTe1-x solar cells is CdCl2 annealing at high temperatures, during which Se diffuses through the absorber layer. Understanding the local Se distribution in the absorber and its impact on optical properties of the material is key for the further development of this thin-film solar cell technology. In a multimodal x-ray scanning microscopy approach, we investigated the impact of the annealing temperature of CdSexTe1-x solar cells on the Se distribution and on optical characteristics of the material. For this purpose, we exploited an upgraded x-ray excited optical luminescence (XEOL) detection unit that enables simultaneous spectrally and temporally resolved XEOL mapping at synchrotron facilities that are ideal for studying thin-film solar-cell materials with hard x-rays featuring high penetration depth and lateral resolution.

14 SOLAR ENERGY

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)

Cooperative and bifunctional Ga-Ca-Cr 2 O 3 @CaO structured monoliths as versatile platform for reactive capture of CO 2 and its subsequent conversion to ethylene

Cooperative and bifunctional materials (BFMs) that integrate adsorbents and catalysts offer a promising strategy for the reactive capture of CO 2 to produce valuable fuels and chemicals. In this study, we developed structured BFMs via 3D printing that combine CaO as an adsorbent with Ga–Ca–Cr 2 O 3 metal oxides as the catalyst for the reactive capture of CO 2 and its subsequent conversion to C 2 H 4 via the oxidative dehydrogenation of C 2 H 6 (CO 2 -ODHE). Three different Ga–Ca compositions were used to modify the catalyst surface characteristics and enhance C 2 H 4 selectivity. In these formulations, Ga ions stabilize the oxygen lattice of the BFM, while Ca ions interact strongly with Cr to form CaCrO 4 , thereby altering the oxygen species and enhancing the material’s basic properties. Under adsorption–reaction conditions at 600–650 °C, the optimal BFM achieved an excellent C 2 H 4 selectivity of 96.4 %, attributed to a balanced redox process and improved basicity that facilitate efficient C 2 H 6 conversion and rapid desorption of C 2 H 4 without excessive oxidation. Overall, this work provides new insights into the formulation of BFMs monoliths and highlights the critical role of catalytic surface modification in enhancing C 2 H 4 selectivity in the CO 2 -ODHE reactive capture process.

C2H4 production

The effect of gamma ray irradiation on few layered MoSe2: A material for nuclear and space applications

In recent years, emerging two-dimensional (2D) materials, such as molybdenum diselenide (MoSe2), have been at the center of attention for many researchers. This is due to their unique and fascinating physicochemical properties that make them attractive in space and defense applications that include shielding harsh irradiation environments. In this study, we examined the effects of gamma (γ) rays at various doses on the structural, chemical, and optical properties of MoSe2 layers. After the samples were exposed to intense gamma radiation (from a 60Co source) with various exposure times to vary the total accumulated dosage (up to 100 kGy), Raman and photoluminescence spectroscopies were used to study and probe radiation-induced changes to the samples. When compared to pristine materials, very few changes in optical properties were typically observed, indicating good robustness with little sensitivity, even at relatively high doses of gamma radiation. The imaging using scanning electron microscopy revealed a number of nano-hillocks that were connected to substrate alterations. X-ray photoelectron spectroscopies revealed that Mo’s binding energies remained the same, but Se’s binding energies blueshifted. We associated this shift with the decrease in Se vacancies that occurred after irradiation as a result of Mo atoms creating adatoms next to Se atoms. When compared to pristine materials, very few changes in optical, chemical, and structural properties were typically observed. These findings highlight the inherent resilience of MoSe2 in hostile radioactive conditions, which spurs additional research into their optical, electrical, and structural characteristics as well as exploration for potential space, energy, and defense applications.

Materials Science

Physics basis for the reference flat-top plasma scenario in the ST–E1 fusion power plant

As part of the U.S. Department of Energy’s Milestone-Based Fusion Energy Development Program, Tokamak Energy has completed the pre-concept design of the ST–E1 fusion power plant. ST–E1 is envisaged to operate in two phases: a pilot plant phase, targeting sustained net power production of 300 - 500 MWe for a duration >1 hr, followed by a commercial power plant phase targeting steady-state operations and a normalised overnight capital cost of ⩽12 000 $\$$/kWe. The design process adopted was highly iterative, integrating all major plant systems and progressing in a phased fidelity approach. At the pre-conceptual stage, the emphasis has been on exploring the design space, identifying the main system-level trade-offs, and making the key decisions that define the overall plant concept, rather than optimising a single operating point. This paper, part of a focused collection detailing the ST–E1 pre-concept design, addresses the development of a series of reference flat-top plasma operating points for the pilot plant phase. A modelling workflow was established to develop and assess candidate plasma design points and explore key dependencies. The workflow includes integrated core plasma modelling, magnetohydrodynamic (MHD) stability assessment, equilibrium generation, scrape-off-layer and exhaust modelling, heating & current drive design and optimisation, and turbulent transport modelling. Using this framework, the impact of several key parameters on the flat-top operating space was investigated, including the density limit, core radiation fraction and divertor power loading, level of external heating and curent drive power and assumed pedestal characteristics. The MHD stability, controllability and micro-stability characteristics of these plasmas were also analysed. These investigations informed the definition of a set of fully non-inductive, flat-top reference operating points that satisfy the high-level ST–E1 mission, including a low and high density case, a case that is stable to resistive wall modes and a case with reduced divertor power loading.

ST–E1

Direct Measurement of Cl − Activity in Metal Chloride Molten Salts using a Cl 2 /Cl − Electrode

Molten metal chloride salts are promising candidates for advanced heat transfer fluids in generation IV nuclear reactors and beyond. The activity of the chloride ion in the salt has a large influence on the redox characteristics of the corresponding molten salt. There exists a knowledge gap for the direct measurement of chlorobasicity (Lewis basicity) in molten-salt mixtures. Here, the focus of this work was to develop a Cl 2 /Cl − electrode for the direct measurement of chloride activity in molten metal-chloride salt mixtures. The LiCl–KCl eutectic system was utilized as the reference melt to determine the change in chloride ion activity as increasing concentrations of MgCl 2 are added to the LiCl–KCl eutectic working electrode. The results of the measurements indicated a reduction in chloride ion activity as the concentration of magnesium chloride increased, consistent with the complexation of free chlorides by Lewis acidic magnesium cationic species. The Temkin model was used to estimate the thermodynamic properties of MgCl 4 2− complex.

Chloride

Grain boundary segregation and chemical ordering in CoCrFeMnNi multi-principal element alloy

Owing to their far-from-dilute compositions, multi-principal element alloys (MPEAs) can exhibit unique combinations of engineering properties. As nearly all MPEAs are polycrystalline aggregates, it is necessary to understand the interactions of various elemental species with grain boundaries (GBs). This is of particular importance in extreme environments, such as radiation and elevated temperatures, where such interactions have implications on the properties of MPEAs. Herein, we employ atomistic simulations to generate a series of [001] asymmetric tilt GBs in a model CoCrFeMnNi MPEA and quantify solute interactions and segregation to these boundaries. We employ the Warren-Cowley order parameters to investigate the interplay between GB segregation and chemical short-range order (SRO). At temperatures above 800 K, simulation results reveal the segregation of Cr and Mn to CoCrFeMnNi GBs and show weak dependence of boundary solute excess on GB geometry, at least for the boundaries explored in this work. At temperatures in the range of 673–800 K, formation of domains rich in Cr is observed at GBs in agreement with experimental observations. Quantitative analysis shows that solute excess of various alloying elements decreases rapidly with the increase in temperature in the range of 1000–1200 K. Furthermore, we show that GB regions exhibit SRO characteristics that are distinct from the bulk crystals, leading to spatial variations in SRO. In broad terms, our study highlights the need to account for GB interactions with alloying elements when designing advanced MPEAs with novel chemistries.

Wang, Yitao [Lehigh University, Bethlehem, PA (Uni

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

SOLPS-ITER modeling of a dedicated divertor for negative triangularity operation on DIII-D

The design of a new dedicated divertor for negative triangularity (NT) operation on DIII-D with neutral baffles and pumping is informed by SOLPS-ITER transport modeling. This dedicated NT divertor is the latest step in a progression of NT shapes with various divertor characteristics explored on DIII-D, including NT shapes at reduced triangularity and a campaign with stronger shaping that included new armored components on the outboard side. SOLPS simulations played a key role in these divertor designs. Interpretive simulations, using cross-field diffusivities constrained by experimental data in the NT Shelf shape were used to inform the design of the 2023 armor campaign components. A similar procedure used armor campaign data to predict conditions for the dedicated NT divertor. The predictive simulations were used to assess the divertor fluxes, detachment threshold, pumped flux, and neutral leakage. For the dedicated NT divertor, SOLPS simulations and two-point-modeling were used to show the relative impact of magnetic topology (mainly longer connection length) and divertor closure on the divertor conditions relative to the armor campaign. It is predicted that the dedicated NT divertor reaches detachment (measured by target ion flux rollover) at a lower upstream density (≈(1.75−−2.4)×1⁢019m−3) as compared to the armor campaign shape. For the preliminary design geometry, divertor closure reduces the neutral leakage by ≈10%. Parametric optimization indicating further ≈20%–60% improvement in the leakage flux and recycled flux crossing the pump entrance is possible for relatively minor changes to the divertor and baffle layout.

Lore, Jeremy [ORNL] (ORCID:000000029192465X)

Decoupling the capacity fade contributions in polymer electrolyte-based high-voltage solid-state batteries

Polymer electrolyte (PE)-based solid-state batteries (PE-SSBs) made with high-voltage cathodes are known to suffer from severe capacity fade, stemming primarily from the poor oxidative stability of most PEs under high-voltage cycling conditions. PEs also suffer from greater ion-transport limitations compared to liquid or solid electrolytes. However, often, these limitations are collectively stated to be responsible for the observed capacity fade, and it is challenging to decouple the contributions of different factors. Herein, a tunable cell fabrication platform was developed to systematically investigate and decouple the two primary capacity fade drivers (cell impedance growth and kinetic limitations), while keeping the other cell parameters constant. Three PE types with distinct transport characteristics were compared. By utilizing a voltage profile analysis method, the contribution of the cell's internal impedance growth was quantitatively decoupled from the kinetic limitations stemming from the high concentration gradient in the polymer catholyte and slow charge transfer reactions. We demonstrate that the high interfacial impedance did not necessarily correlate with the high capacity fade rate. Kinetic limitations that are not reflected by impedance measurements can play a dominant role in causing cumulative capacity decay.

Ock, Ji-young [Oak Ridge National Laboratory (ORNL

Plasma phosphorylated tau217 strongly associates with memory deficits in the Alzheimer’s disease spectrum

Abstract Plasma phosphorylated tau (p-tau) biomarkers open unprecedented opportunities for identifying carriers of Alzheimer’s disease pathophysiology in early disease stages using minimally invasive techniques. Plasma p-tau biomarkers are believed to reflect tau phosphorylation and secretion. However, it remains unclear to what extent the magnitude of plasma p-tau abnormalities reflects neuronal network disturbance in the form of cognitive impairment. To address this question, we included 103 cognitively unimpaired elderly and 40 cognitively impaired, amyloid-β-positive individuals from the TRIAD cohort, in addition to 336 cognitively unimpaired and 216 cognitively impaired, amyloid-β-positive older adults from the BioFINDER-2 cohort. Participants had tau PET scans, amyloid PET scans or amyloid CSF, p-tau217, p-tau181 and p-tau231 blood measures, structural T1-MRI and cognitive assessments. In this cross-sectional study, we used regression models and correlation analyses to assess the relationship between plasma biomarkers and cognitive scores. Furthermore, we applied receiver operating characteristic curves to assess cognitive impairment across plasma biomarkers. Finally, we categorized participants into amyloid (A), p-tau (T1) and tau PET (T2) positive (+) or negative (−) profiles and ran non-parametric comparisons to assess differences across cognitive domains. We found that plasma p-tau217 was more associated with cognitive performance than p-tau181 and p-tau231 and that this relationship was particularly strong for memory scores (TRIAD: βp-tau217 = −0.53, βp-tau181 = −0.35 and βp-tau231 = −0.24; BioFINDER-2: βp-tau217 = −0.52, βp-tau181 = −0.24 and βp-tau231 = −0.29). Associations in amyloid-β-positive participants resembled these results, but other cognitive scores also showed strong associations in cognitively impaired individuals. Moreover, plasma p-tau217 outperformed plasma p-tau181 and plasma p-tau231 in identifying memory impairment (area under the curve values for TRIAD: p-tau217 = 0.86, p-tau181 = 0.77 and p-tau231 = 0.75; and for BioFINDER-2: p-tau217 = 0.86, p-tau181 = 0.76 and p-tau231 = 0.81) and in identifying executive function impairment only in the BioFINDER-2 cohort (p-tau217 = 0.82, p-tau181 = 0.76 and p-tau231 = 0.76). Lastly, we showed that subtle memory deficits were present in A+T1+T2− participants for plasma p-tau217 (P = 0.007) and plasma p-tau181 (P = 0.01) in the TRIAD cohort and for all biomarkers across cognitive domains in A+T1+T2− and A+T1+T2− individuals (P < 0.001 in all) in the BioFINDER-2 cohort. The A+T1+T2− individuals showed cognitive deficits in both cohorts (P < 0.001 in all). Together, our results suggest that plasma p-tau217 stands out as a biomarker capable of identifying memory deficits attributable to Alzheimer’s disease and that memory impairment certainly occurs in amyloid-β- and plasma p-tau-positive individuals who have no significant amounts of tau in the neocortex.

Neurosciences & Neurology

Cosmic neutrino decoupling and its observable imprints: insights from entropic-dual transport

Abstract Very different processes characterize the decoupling of neutrinos to form the cosmic neutrino background (CνB) and the much later decoupling of photons from thermal equilibrium to form the cosmic microwave background (CMB). The CνB emerges from the fuzzy, energy-dependent neutrinosphere and encodes the physics operating in the early universe in the temperature rangeT∼ 10 MeV toT∼ 10 keV. This is the epoch where beyond Standard Model (BSM) physics, especially in the neutrino sector, may be influential in setting the light element abundances, the necessarily distorted fossil neutrino energy spectra, and other light particle energy density contributions. Here we use techniques honed in extensive CMB studies to analyze the CνB as calculated in detailed neutrino energy transport and nuclear reaction simulations of the protracted weak decoupling and primordial nucleosynthesis epochs. Our moment method, relative entropy, and differential visibility approach can leverage future high precision CMB and light element primordial abundance measurements to provide new insights into the CνB and any BSM physics it encodes. We demonstrate that the evolution of the energy spectrum of the CνB throughout the weak decoupling epoch is accurately captured in the Standard Model by only three parameters per species, a non-trivial conclusion given the deviation from thermal equilibrium and the impact of the decrease of electron-positron pairs. Furthermore, we can interpret each of the three parameters as physical characteristics of a non-equilibrium system. Though the treatment presented here makes some simplifying assumptions including ignoring neutrino flavor oscillations, the success of our compact description within the Standard Model motivates its use also in BSM scenarios. We further demonstrate how observations of primordial light element abundances can be used to place constraints on the CνB energy spectrum, deriving response functions that can be applied for general deviations from a thermal spectrum. Combined with the description of those deviations that we develop here, our methods provide a convenient and powerful framework to constrain the impact of BSM physics on the CνB.

Astronomy & Astrophysics

Advancing technologies for lignin-based jet fuel production in aqueous phase

Integrating lignin into a cellulosic ethanol plant for the co-production of lignin-based jet fuel (LJF) in aqueous phase offers a significant opportunity to boost operational efficiency, economic viability, carbon conversion, and the overall sustainability of biofuel and chemical production. LJF is lignin-structure-based jet fuel blendstocks primarily composed of alkyl-substituted mono-, bi-, and tri-cyclohexanes. It exhibits high energy density, potential for low emissions, and favourable blend characteristics that comply with drop-in specifications. An overview of lignin feedstock, catalytic processes, LJF chemical compositions, fuel properties tests, and techno-economic analysis (TEA) and life cycle assessment (LCA) indicate that (1) the reactivity of lignin plays a crucial role in its structure transformation to LJF molecules; (2) catalytic processing of lignin to LJF can occur through a simultaneous depolymerization and hydrodeoxygenation process, bypassing the intermediate step of producing and upgrading lignin-derived oil; (3) LJF's uniqueness molecules making it more promising for high energy content and low emission jet fuel properties for next generation sustainable aviation fuel (SAF); and (4) TEA and LCA demonstrate that LJF is not only potentially cost-effective but also offers favourable carbon footprint compared to other SAFs. In conclusion, this review highlights the most recent advancements in LJF technology, along with the challenges and opportunities that lie ahead in fulfilling its potential.

09 BIOMASS FUELS

Effects of Composition and Oxidation States on the Structures of Chromium-Containing Sodium Silicate Glasses: Molecular Dynamics Simulations using Machine Learning Interatomic Potentials

Chromium represents a significant challenge for the vitrification of high-level nuclear waste into silicate and borosilicate glasses due to its low solubility and variable oxidation states, which can limit the waste loading due to promotion of crystallization or phase separation during processing. In this study, we modeled chromium containing silicate glasses using molecular dynamics simulations with three machine learning interatomic potentials (MLIPs), MACE, CHGNet, and PFP were employed, to gain insights on glass composition and oxidation states on the structures of these glasses. One of the goals is to evaluate their ability of these MLIPs to accurately represent the general structure of silicate glasses and chromium local environments as a function of chromium oxidation states. Density Functional Theory (DFT) based calculations and experimental data such as neutron structure factors were used to validate the structural models. It was found that the foundation models of all three MLIPs are able to reproduce general structural features of the sodium silicate glass structure consistent with experimental and DFT data, but only CHGNet and PFP can accurately capture the oxidation states and local environment of chromium: tetrahedral for Cr6+ and octahedral for Cr3+. Furthermore, we studied the effect of varying Cr3+/ Cr6+ (Cr3+/Crtotal) ratio and total chromium content using PFP. Our results show that Cr6+ enhances network polymerization by reducing non-bridging oxygens through Na? charge compensation required due to the formation of chromate (CrO42-) species, while Cr³? acts as a network modifier that disrupts connectivity. System size effects on the structural characteristics and chromium environments were also tested using the PFP potential. This work highlights the importance of careful validation on the precision, transferability, and potential of MLIPs for modeling glasses containing transition metal elements that can exist in multiple oxidation states. It is also encouraging to see the foundational models are all three MLFFs are able to reproduce the basic sodium silicate glass structures, while suggesting additional training or refining is needed to improve the description of more complex systems containing transition metals.

Puga, Christina L.

Phonon-mediated ultrafast dynamics in self-assembled monolayers of 4-mercaptobenzoic acid on gold

Non-equilibrium interactions between plasmonic metals and adsorbed molecules lie at the heart of emerging applications such as plasmonic photocatalysis and sensing, though the ultrafast charge and energy transfer mechanisms arising from these interactions are not well understood. Herein, we investigate the ultrafast dynamics of Au nano-islands tethered with a self-assembled monolayer (SAM) of electron-withdrawing 4-mercaptobenzoic acid (4MBA) molecules. Ultrafast UV-visible transient absorption spectroscopy following excitation of the interband transition in Au reveals three well-known, characteristic time constants that quantify electron–electron (el–el), electron–phonon (el–ph) and phonon–phonon (ph–ph) scattering lifetimes. When comparing the dynamics of bare Au and 4MBA-Au, we find that the el–ph and ph–ph scattering lifetimes are notably longer in 4MBA-Au. Density functional perturbation theory calculations ascribe the elongation in el–ph lifetimes in 4MBA-Au to the significant coupling of acoustic phonon modes of Au with certain molecular vibrations of 4MBA, leading to decreased spatial overlap between carrier electronic states and the acoustic modes. We speculate that the elongation of ph–ph scattering lifetimes in 4MBA-Au arises due to poor thermal conductivity of the SAM which disrupts efficient energy dissipation from Au to the environment, thus slowing down the thermalization of phonons. This work provides a glimpse into how molecular adsorbates modify the charge carrier and phonon dynamics of Au and sets the stage for further systematic exploration of plasmonic metal–molecule interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Distributed Mafic Rock Resources for Carbon Mineralization in Arizona

Ex-situ carbon mineralization is a process by which CO2 is reacted with alkaline silicate minerals and rocks to produce stable carbonate materials, which can be used for other industrial processes. Arizona, U.S.A., hosts abundant surficial mafic rocks in three young volcanic fields, Geronimo-San Bernardino, San Francisco, and Springerville, and other distributed locations throughout the state. We created a Mafic Rock Resource Inventory (MRRI) that categorizes geochemical, physical, and textural characteristics of a diverse suite of surficial mafic rock samples and provide a benchmark reaction dataset parameterizing the temperature, pressure, and pH conditions best suited ex-situ mineralization in different rock types. MRRI data is publicly available online via a map-viewer. We establish two reaction condition sets, varied in temperature, pressure, and pH, where crystal-rich and glassy rocks reach maximum reaction extent and different carbonate phases are formed. Systematic ex-situ mineralization experiments on 21 diverse rock types show trends in geochemical, mineralogical, and reactivity behavior and establish maximum effective capture capacity. From this, scoria cones in three Arizona volcanic fields have a ~62 Gt effective CO₂ storage capacity with one of the fields having a ~42 Gt storage capacity in lava flows. Reactivity results have applications to alkaline mafic rock resources exposed globally, including producing additional effective storage capacity estimates and scaled commercialization of mafic rock ex-situ mineralization, should reaction extents be improved through advances in mineralization techniques. MRRI data were used to create a Direct Air Capture to Mineralization (DACM) systems model, technoeconomic analysis, and life-cycle assessment. These documents are presented as three appendices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

Realignment and suppression of charge density waves in the rare-earth tritellurides 𝑅⁢Te 3 (𝑅 = La, Gd, Er)

The rare-earth tritellurides have a rich phase diagram that includes charge density waves (CDWs), superconductivity, and magnetic order, offering a platform to study the interplay between these phases on a square-net system. Prior studies have shown that defects can affect the CDW characteristics in these materials, yet coupling between the CDW order and the underlying microstructure has not been studied at the nanoscale. Here we use scanning transmission electron microscopy at cryogenic temperatures to directly visualize the effects of defects on the CDW order and provide a spatially resolved microscopic correlation between the CDW transition and structural defects. Here, we show that in the presence of extended defects, such as dislocations and stacking faults, the weak orthorhombicity of the rare-earth tritellurides is lost and the material becomes pseudotetragonal. Since the orthorhombicity acts as a symmetry breaking field for the CDW transitions in rare-earth tritellurides, the presence of these extended defects modulates the energetics of the CDWs and suppresses the ground-state CDW phase at low temperature.

Charge density waves