Stability of Solid Uranyl Peroxides under Irradiation

The effects of radiation on a variety of uranyl peroxide compounds were examined using γ-rays and 5 MeV He ions, the latter to simulate α-particles. The studied materials were studtite, [(UO 2 )(O 2 )(H 2 O)2](H 2 O) 2 , the salt of the U 60 uranyl peroxide cage cluster, Li 44 K 16 [(UO 2 )(O 2 )(OH)] 60 ·255H 2 O, the salt of U 60 Ox 30 uranyl peroxide oxalate cage cluster, Li 12 K 48 [{(UO 2 )(O 2 )} 60 (C 2 O 4 ) 30 ]·$n$H 2 O, and the salt of the U 24 Pp 12 (Pp = pyrophosphate) uranyl peroxide pyrophosphate cage cluster, Li 24 Na 24 [(UO 2 ) 24 (O 2 ) 24 (P2O7)12]·120H 2 O. Irradiated powders were characterized using powder X-ray diffraction, Raman spectroscopy, infrared spectroscopy, X-ray photoelectron spectroscopy, and UV–vis spectroscopy. A weakening of the uranyl bonds of U60 was found while studtite, U 60 Ox 30 , and U 24 Pp 12 were relatively stable to $γ$-irradiation. Studtite and U 60 are the most affected by α-irradiation forming an amorphous uranyl peroxide as characterized by Raman spectroscopy and powder X-ray diffraction while U 60 Ox 30 and U 24 Pp 12 show minor signs of the formation of an amorphous uranyl peroxide.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evidence for non-electrostatic interactions between a pyrophosphate-functionalized uranyl peroxide nanocluster and iron (hydr)oxide minerals

We report the terminal oxygen atoms of the pyrophosphate groups in the uranyl peroxide nanocluster U 24 Pp 12 ([(UO 2 ) 24 (O 2 ) 24 (P 2 O 7 ) 12 ] 48- ) are not fully satisfied by bond valence considerations and can become protonated. This functionality could allow for specific interactions with mineral surfaces, as opposed to the electrostatically-driven interactions observed between non-functionalized uranyl peroxide nanoclusters and mineral surfaces. The sorption of U 24 Pp 12 to goethite and hematite was studied using batch sorption experiments as a function of U 24 Pp 12 concentration, mineral concentration, and pH. A suite of spectroscopic techniques, scanning electron microscopy, and electrophoretic mobility measurements were used to examine the minerals before and after reaction with U 24 Pp 12 , leading to a proposed conceptual model for U 24 Pp 12 interactions with goethite. The governing rate laws were determined and compared to those previously determined for a non-functionalized uranyl peroxide nanocluster. The rate of uranyl peroxide nanocluster sorption depends on the charge density and functionalized component of the uranyl peroxide cage. Electrophoretic mobility and attenuated total reflectance Fourier transform infrared spectroscopy analyses show that an inner-sphere complex forms between the U 24 Pp 12 cluster and the goethite surface through the terminal pyrophosphate groups, leading to a proposed conceptual model in which U 24 Pp 12 interacts with the triply-coordinated reactive sites on the (110) plane of goethite. Finally, these results demonstrate that the behavior of U 24 Pp 12 at the iron (hydr)oxide-water interface is unique relative to interactions of the uranyl ion and non-functionalized uranyl peroxide nanoclusters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hazard Assessment of Personal Protective Clothing for Hydrogen Peroxide Service

Selection of personal protective equipment (PPE) for hydrogen peroxide service is an important part of the hazard assessment process. But because drip testing of chemical protective clothing for hydrogen peroxide service has not been reported for about 40 years, it is of great interest to test new protective clothing materials with new, high-concentration hydrogen peroxide following similar procedures. The suitability of PPE for hydrogen peroxide service is in part determined by observations made when hydrogen peroxide is dripped onto swatches of protective clothing material. Protective clothing material was tested as received, in soiled condition, and in grossly soiled condition. Materials were soiled by pretreating the material with potassium permanganate (KMnO4) solution then drying to promote a reaction. Materials were grossly soiled with solid KMnO4 to greatly promote reaction. Observations of results including visual changes to the hydrogen peroxide and materials, times to ignition, and self-extinguishing characteristics of the materials are reported.

Greene, Ben↗

APPARATUS AND METHOD FOR TREATING POLLUTANTS IN A GAS USING HYDROGEN PEROXIDE AND UV LIGHT

An apparatus for treating pollutants in a gas may include a source of hydrogen peroxide, and a treatment injector for creating and injecting dissociated hydrogen peroxide into the flow of gas. The treatment injector may further include an injector housing having an inlet, an outlet, and a hollow interior extending there between. The inlet may be connected in fluid communication with the source of hydrogen peroxide so that hydrogen peroxide flows through the hollow interior and toward the outlet. At least one ultraviolet (UV) lamp may be positioned within the hollow interior of the injector housing. The at least one UV lamp may dissociate the hydrogen peroxide flowing through the tube. The dissociated hydrogen peroxide may be injected into the flow of gas from the outlet for treating pollutants, such as nitrogen oxides.

Cooper, Charles David↗

Concentration of Hydrogen Peroxide

Methods for concentrating hydrogen peroxide solutions have been described. The methods utilize a polymeric membrane separating a hydrogen peroxide solution from a sweep gas or permeate. The membrane is selective to the permeability of water over the permeability of hydrogen peroxide, thereby facilitating the concentration of the hydrogen peroxide solution through the transport of water through the membrane to the permeate. By utilizing methods in accordance with the invention, hydrogen peroxide solutions of up to 85% by volume or higher may be generated at a point of use without storing substantial quantities of the highly concentrated solutions and without requiring temperatures that would produce explosive mixtures of hydrogen peroxide vapors.

Parrish, Clyde F.↗

Apparatus and method for treating pollutants in a gas using hydrogen peroxide and UV light

An apparatus for treating pollutants in a gas may include a source of hydrogen peroxide, and a treatment injector for creating and injecting dissociated hydrogen peroxide into the flow of gas. The treatment injector may further include an injector housing having an inlet, an outlet, and a hollow interior extending therebetween. The inlet may be connected in fluid communication with the source of hydrogen peroxide so that hydrogen peroxide flows through the hollow interior and toward the outlet. At least one ultraviolet (UV) lamp may be positioned within the hollow interior of the injector housing. The at least one UV lamp may dissociate the hydrogen peroxide flowing through the tube. The dissociated hydrogen peroxide may be injected into the flow of gas from the outlet for treating pollutants, such as nitrogen oxides.

Cooper, Charles David↗

Coating for components requiring hydrogen peroxide compatibility

The present invention provides a heretofore-unknown use for zirconium nitride as a hydrogen peroxide compatible protective coating that was discovered to be useful to protect components that catalyze the decomposition of hydrogen peroxide or corrode when exposed to hydrogen peroxide. A zirconium nitride coating of the invention may be applied to a variety of substrates (e.g., metals) using art-recognized techniques, such as plasma vapor deposition. The present invention further provides components and articles of manufacture having hydrogen peroxide compatibility, particularly components for use in aerospace and industrial manufacturing applications. The zirconium nitride barrier coating of the invention provides protection from corrosion by reaction with hydrogen peroxide, as well as prevention of hydrogen peroxide decomposition.

Yousefiani, Ali↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements.

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Esculetin-induced protection of human hepatoma HepG2 cells against hydrogen peroxide is associated with the Nrf2-dependent induction of the NAD(P)H: Quinone oxidoreductase 1 gene

Esculetin (6,7-dihydroxy coumarin), is a potent antioxidant that is present in several plant species. The aim of this study was to investigate the mechanism of protection of esculetin in human hepatoma HepG2 cells against reactive oxygen species (ROS) induced by hydrogen peroxide. Cell viability, cell integrity, intracellular glutathione levels, generation of reactive oxygen species and expression of antioxidant enzymes were used as markers to measure cellular oxidative stress and response to ROS. The protective effect of esculetin was compared to a well-characterized chemoprotective compound quercetin. Pre-treatment of HepG2 cells with sub-lethal (10-25 {mu}M) esculetin for 8 h prevented cell death and maintained cell integrity following exposure to 0.9 mM hydrogen peroxide. An increase in the generation of ROS following hydrogen peroxide treatment was significantly attenuated by 8 h pre-treatment with esculetin. In addition, esculetin ameliorated the decrease in intracellular glutathione caused by hydrogen peroxide exposure. Moreover, treatment with 25 {mu}M esculetin for 8 h increased the expression of NAD(P)H: quinone oxidoreductase (NQO1) at both protein and mRNA levels significantly, by 12-fold and 15-fold, respectively. Esculetin treatment also increased nuclear accumulation of Nrf2 by 8-fold indicating that increased NQO1 expression is Nrf2-mediated. These results indicate that esculetin protects human hepatoma HepG2 cells from hydrogen peroxide induced oxidative injury and that this protection is provided through the induction of protective enzymes as part of an adaptive response mediated by Nrf2 nuclear accumulation.

60 APPLIED LIFE SCIENCES↗

Dissolution of poorly soluble uranyl phosphate phases in the Metaautunite Subgroup under uranyl peroxide cage cluster forming conditions

Uranyl phosphate minerals are widespread in uranium deposits and usually exhibit very low solubility in aqueous systems. Uranyl phosphates of the autunite group and metaautunite subgroup impact the mobility of uranium in the environment and have inspired groundwater remediation strategies that emphasize their low solubility. The importance of soluble uranium-bearing macro-anions, including nanoscale uranyl peroxide cage clusters, is largely unexplored relative to solubilization of normally low-solubility uranium minerals. Eight synthetic analogs of metaautunite subgroup minerals have been prepared and placed in various alkaline aqueous solutions containing hydrogen peroxide and tetraethylammonium hydroxide. Each uranyl phosphate studied has a topologically identical anionic sheet of uranyl square bipyramids and phosphate tetrahedra combined with various cations (Li + , Na + , K + , Rb + , Cs + , Mg 2+ , Ca 2+ , Ba 2+ ) and water in the interlayer. Uranyl peroxides formed under many of the experimental conditions examined, including solid studtite [(UO 2 )(O 2 )(H 2 O) 2 ](H 2 O) 2 and soluble uranyl peroxide cage clusters containing as many as 28 uranyl ions. Uranyl phosphate solids in contact with solutions in which uranyl peroxide cage clusters formed dissolved extensively or completely. The greatest dissolution of uranyl phosphates occurred in systems that contained cations with larger hydrated radii, Li + and Na + . The details of the uranium speciation in solution depended on the pH and counter cations provided from the interlayers of the uranyl phosphate solids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inactivation of possible micromycete food contaminants using the low-temperature plasma and hydrogen peroxide

The inhibition effect of hydrogen peroxide aerosol, low-temperature plasma and their combinations has been studied on several micromycetes spores. The low-temperature plasma was generated in corona discharges in the open air apparatus with hydrogen peroxide aerosol. Micromycete spores were inoculated on the surface of agar plates, exposed solely to the hydrogen peroxide aerosol, corona discharge or their combination. After incubation the diameter of inhibition zone was measured. The solely positive corona discharge exhibits no inactivation effect, the solely negative corona discharge and solely hydrogen peroxide aerosol exhibit the inactivation effect, however their combinations exhibit to be much more effective. Low-temperature plasma and hydrogen peroxide aerosol present a possible alternative method of microbial decontamination of food, food packages or other thermolabile materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scale-Up of Electrode Coating and Flow-Field for Commercial Hydrogen Peroxide Electrolyzer: Cooperative Research and Development Final Report, CRADA Number CRD-17-00687

Hydrogen peroxide is currently produced at central chemical plants via the anthraquinone oxidation process. This process produces environmental pollutants that are costly to remediate, requires hazardous long distance shipping of highly concentrated peroxide (50% or 70%), and necessitates extra handling costs related to storage and dilution. Peroxygen Systems, Inc. (PSi) is developing breakthrough technology for on-site hydrogen peroxide production. PSi’s on-site on-demand electrolyzer can reduce the cost of producing hydrogen peroxide by 50%, while also completely eliminating the cost and safety issues associated with shipping and handling of high concentration hydrogen peroxide. The challenge for PSi is scaling. To support the next step toward commercialization (customer pilot tests), scaling the prototype into larger single cells and 20-40 cell stacks is required. In addition to internal hardware and flow-field design efforts at PSi, NREL will address three critical problems for this scale-up effort: (1) demonstrating a large scale roll-to-roll (R2R) process to coat uniform electrode materials for 100 cm2 and 500 cm2 stack testing, (2) demonstrating an in-line diagnostic to achieve better electrode quality control, and (3) performing in situ cell/stack testing to better understand and optimize the performance of the flow field design.

28 EE - Advanced Manufacturing Office (EE-5A)↗

In-Situ Electrochemical Generation and Utilization of Hydrogen Peroxide for Disinfection

Disinfection needs to meet personal hygiene requirements at the International Space Station (ISS) is currently accomplished through the use of pre-packaged, disposable, wetted wipes, which represent an appreciable carry-along mass and disposal burden. However, as human missions travel further into the solar system the availability of resources to resupply will be diminished. Therefore, next-generation system should use onboard utilities to create on demand disinfectants, thereby reducing the dependence on earth-based supplies and further eliminating storage and disposal problems. Accordingly, we are developing an in-situ approach to electrochemically generate hydrogen peroxide disinfecting solution utilizing onboard life support supplies (Air/Water) to neutralize surface microorganisms present in closed living systems. As discussed within our 2019 and 2021 ICES papers (ICES-2019-38 and ICES-2021-273), we have continued to improve our TRL by scaling the electrochemical generation production process and validating the system in a zero-gravity parabolic loop flight test. In this paper we will demonstrate a system that can achieve over 1 L of >2 w/w% peroxide per day with DI water and air feeds. The hydrogen peroxide solutions generated were sent to NASA for microbial control property characterization. Overall, the electrochemical peroxide generation system offers a more economical and practical alternative, with the disinfectant being generated on demand and in-situ (using available life support materials of Air/Water); and applied to reusable cloths. The specific application of interest to this program is crew contact surfaces in space vehicles, but this technology could be utilized for waste water disinfection, heat exchanger biofouling remediation, and laundry applications. The peroxide generation system will also be able to address Earth-based needs in various settings such as field hospitals, restaurants, military, warehouses, movie theatres, among many others.

hydrogen peroxide↗

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)↗

Peroxide Decomposer Module Catalyst Testing to Support Preparations for Increased Demand - 19052

The Hanford Site Effluent Treatment Facility's (ETF) mission is to receive, treat, and dispose of liquid effluents from on-site programs and projects. Its roles in the management and mitigation of tank waste volume is integral to the overall Hanford tank farms mission, as tank space is limited. ETF's role will become even more essential as the Direct-Feed Low Activity Waste process comes online at the Waste Treatment and Immobilization Plant (WTP). In order to accommodate the additional liquid effluent streams, the ETF will undergo a number of facility and equipment upgrades. Included in this is the reinstatement of the Peroxide Decomposer Module (PDM) into the ETF's main treatment train. The PDM is used to remove any residual hydrogen peroxide not fully consumed in the preceding ultraviolet/oxidation (UV/OX) treatment stage for organic destruction. Future waste stream estimates have been shown to contain organic content requiring excess hydrogen peroxide addition. Restoration of the PDM will ensure the ETF can accommodate the higher anticipated levels of organic content in these new influent streams. Due to low organic content levels in the current influents and some operability issues with the PDM, it has not been in operation since 1998. One aspect of the repair and upgrade of the PDM is the usability of manganese dioxide on alumina catalyst, Sud-Chemie T-2525, which was purchased in 2008 but has remained in storage since. The manufacturer of the catalyst states there is no known shelf life for the product and no current data to indicate the catalyst's performance after long-term storage. To determine the usability of the stored catalyst, a laboratory test was developed. The testing of this stored catalyst was based on testing methods and information collected from initial catalyst product testing performed in 2008. This test involved spiking the catalyst with 200 ppm hydrogen peroxide and then testing the resulting solution to determine the extent of peroxide destruction. Initial testing results of the Sud-Chemie T-2525 catalyst indicated reduced performance, so additional catalyst materials were selected for inclusion in the testing. These materials included Carulite{sup R} 200 catalyst, LayneOx{sup R}, natural manganese ore - pyrolusite (Pro-Ox{sup R}), and EnviCat{sup R} 2531 SPH 4-6. With the expansion of the test scope, fines generation testing was added to provide additional data for product selection, as excessive fines cause plugging in the PDM. The resulting test data are compared to the 2008 catalyst product testing data in order to evaluate performance of each product to determine whether the Sud-Chemie T-2525 is still viable and to determine the best candidate for its replacement. This testing provides essential information to the engineering and operations organizations managing the facility and equipment upgrades for the ETF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pyrophosphate and Methylenediphosphonate Incorporated Uranyl Peroxide Cage Clusters

Six uranyl peroxide cage clusters containing 18–54 uranyl ions, as well as 6–27 pyrophosphate or methylenediphosphonate ligands, have been synthesized and characterized. These uranyl peroxide clusters self-assemble and crystallize from aqueous solutions containing uranyl nitrate, hydrogen peroxide, and pyrophosphate or methylenediphosphonate over a pH range from 5.3 to 8.1. In their structures, uranyl hexagonal bipyramids are linked by bridging peroxide, hydroxide, and pyrophosphate or methylenedisphosphonate ligands. The incorporation of pyrophosphate or methylenedisphosphonate results in several interesting features in the coordination of uranyl ions and the topology of the uranyl peroxide clusters.

nuclear (including radiation effects), materials a↗

Radiation-Induced Solid-State Transformations of Uranyl Peroxides

Single-crystal X-ray diffraction studies of pristine and γ-irradiated Ca 2 [UO 2 (O 2 ) 3 ]·9H 2 O reveal site-specific atomic-scale changes during the solid-state progression from a crystalline to X-ray amorphous state with increasing dose. Following γ-irradiation to 1, 1.5, and 2 MGy, the peroxide group not bonded to Ca 2+ is progressively replaced by two hydroxyl groups separated by 2.7 Å (with minor changes in the unit cell), whereas the peroxide groups bonded to Ca 2+ cations are largely unaffected by irradiation prior to amorphization, which occurs by a dose of 3 MGy. The conversion of peroxide to hydroxyl occurs through interaction of neighboring lattice H 2 O molecules and ionization of the peroxide O–O bond, which produces two hydroxyls, and allows isolation of the important monomer building block, UO 2 (O 2 ) 2 (OH) 2 4– , that is ubiquitous in uranyl capsule polyoxometalates. Steric crowding in the equatorial plane of the uranyl ion develops and promotes transformation to an amorphous phase. In contrast, γ-irradiation of solid Li 4 [(UO 2 )(O 2 ) 3 ]·10H 2 O results in a solid-state transformation to a well-crystallized peroxide-free uranyl oxyhydrate containing sheets of equatorial edge and vertex-sharing uranyl pentagonal bipyramids with likely Li and H 2 O in interlayer positions. The irradiation products of these two uranyl triperoxide monomers are compared via X-ray diffraction (single-crystal and powder) and Raman spectroscopy, with a focus on the influence of the Li + and Ca 2+ countercations. Highly hydratable and mobile Li+ yields to uranyl hydrolysis reactions, while Ca 2+ provides lattice rigidity, allowing observation of the first steps of radiation-promoted transformation of uranyl triperoxide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗