Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOELECTRON COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

Abstract The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $$\upbeta $$ β -decay endpoint region with a sensitivity on $$m_\nu $$ m ν of 0.2 $$\hbox {eV}/\hbox {c}^2$$ eV / c 2 (90% CL). For this purpose, the $$\upbeta $$ β -electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6 keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $$\upbeta $$ β -electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% $$\hbox {T}_2$$ T 2 gas mixture at 30 K, as used in the first KATRIN neutrino-mass analyses, as well as a $$\hbox {D}_2$$ D 2 gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $$\sigma (m_\nu ^2)< {{10}^{-2}}{\hbox {eV}^{2}}$$ σ ( m ν 2 ) < 10 - 2 eV 2 [1] in the KATRIN neutrino-mass measurement to a subdominant level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems for measuring response statistics of gigahertz bandwidth photomultipliers

New systems have been developed for measuring the average impulse response, the pulse-height spectrum, the transit-time statistics as a function of signal level, and the dark-count spectrum of gigahertz bandwidth photomultipliers. Measurements showed that the 0.53 microns pulse used as an optical test source had a 30 picoseconds and less than 70 ps pulse width. Calibration data showed the system resolution to be less than 20 ps for root mean square transit-time measurements. Test data for a static crossed-field photomultiplier showed 2-photoelectron resolution and less than 30-ps time jitter over the 1- to 100-photoelectron range.

Abshire, J. B.↗

Synthesis, structural characterization and properties of SrAl{sub 4−x}Ge{sub x}, BaAl{sub 4−x}Ge{sub x}, and EuAl{sub 4−x}Ge{sub x} (x≈0.3–0.4)—Rare examples of electron-rich phases with the BaAl{sub 4} structure type

Three solid solutions with the general formula AEAl{sub 4−x}Ge{sub x} (AE=Eu, Sr, Ba; 0.32(1)≤x≤0.41(1)) have been synthesized via the aluminum self-flux method, and their crystal structures have been established from powder and single-crystal X-ray diffraction. They are isotypic and crystallize with the well-known BaAl{sub 4} structure type, adopted by the three AEAl{sub 4} end members. In all structures, Ge substitutes Al only at the 4e Wyckoff site. Results from X-rays photoelectron spectroscopy on EuAl{sub 4−x}Ge{sub x} and EuAl{sub 4} indicate that the interactions between the Eu{sup 2+} cations and the polyanionic framework are enhanced in the Ge-doped structure, despite the slightly elevated Fermi level. Magnetic susceptibility measurements confirm the local moment magnetism, expected for the [Xe]4f{sup 7} electronic configuration of Eu{sup 2+} and suggest strong ferromagnetic interactions at cryogenic temperatures. Resistivity data from single-crystalline samples show differences between the title compounds, implying different bonding characteristics despite the close Debye temperatures. A brief discussion on the observed electron count and homogeneity ranges for AEAl{sub 4−x}Ge{sub x} (AE=Eu, Sr, Ba) is also presented. - Graphical abstract: AEAl{sub 4−x}Ge{sub x} (AE=Eu, Sr, Ba; 0.32(1)≤x≤0.41(1)), three “electron-rich” phases with BaAl{sub 4} structure type have been synthesized and characterized. Display Omitted - Highlights: • Three BaAl{sub 4}-type ternary aluminum germanides have been synthesized with Eu, Sr and Ba. • Eu, Sr and Ba cations have no apparent influence on the solubility of Ge. • The Ge atoms substitute Al on one of two framework sites, thereby strengthening the interactions between the cations and the polyanionic framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of temperature on capacity fade in silicon-rich anodes

Coin half-cells containing 80 wt% silicon electrodes are assembled and cycled at the similar to C/10 rate in the temperature range of 25-55 degrees C. To the best of our knowledge, this is the first time that the effect of temperature is reported for such high-silicon-containing cells. Two different electrolytes are used in this study, a baseline electrolyte and the baseline electrolyte +10 wt% fluoroethylene carbonate (FEC). Analysis of the capacity vs. cycle count data by curve fitting reveals that the addition of FEC markedly affects the capacity loss mechanism. Without FEC, the kinetic rate law for the capacity loss mechanism can be described as the sum of two logistic growth models. With the addition of FEC, the rate law depends on ln(t). Clearly, the addition of FEC has a profound effect on the mechanism of capacity loss. Interestingly, X-ray photoelectron spectroscopy (XPS) shows that the composition of the solid electrolyte interphase (SEI) layer changes markedly from mostly organic to mostly inorganic in the presence of FEC and how it varies at the different temperatures tested, especially in the absence of FEC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On a photon-counting array using the Fairchild CCD-201

The evaluation of certain performance parameters of the Fairchild CCD 201 and the proposed method of operation of an electron bombarded charge coupled device are described. Work in progress on the evaluation of the parameters relevant to remote, low noise operation is reported. These tests have been conducted using light input. The video data from the CCD are amplified, digitized, stored in a minicomputer memory, and then recorded on magnetic tape for analyzing. The device will be used in an array of sensors in the aperture plane of a telescope to discriminate between photoelectron events, and in the focal plane operating at single photoelectron sensitivity at a minimum of blooming and lag.

Currie, D. G.↗

Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources

ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric and magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

Influence of counterion substitution on the properties of imidazolium-based ionic liquid clusters

Due to their unique physiochemical properties that may be tailored for specific purposes, ionic liquids (ILs) have been investigated for various applications, including chemical separations, catalysis, energy storage, and space propulsion. The different cations and anions comprising ILs may be selected to optimize a range of desired properties, such as thermal stability, ionic conductivity, and volatility, leading to the designation of certain ILs as designer “green” solvents. The effect of counterions on the properties of ILs is of both fundamental scientific interest and technological importance. Herein, we report a systematic experimental and theoretical investigation of the size, charge, stability toward dissociation, and geometric/electronic structure of 1-ethyl-3-methyl imidazolium (EMIM)-based IL clusters containing two different atomic counterions (i.e., bromide [Br − ] and iodide [I − ]). This work extends our studies of EMIM + cations with atomic chloride (Cl − ) and molecular tetrafluoroborate (BF 4 − ) anions reported previously by Baxter et al. [Chem. Mater. 34, 2612 (2022)] and Zhang et al . [J. Phys. Chem. Lett. 11, 6844 (2020)], respectively. Distributions of anionic IL clusters were generated in the gas phase using electrospray ionization and characterized by high mass resolution mass spectrometry, energy-resolved collision-induced dissociation, and negative ion photoelectron spectroscopy experiments. The experimental results reveal anion-dependent trends in the size distribution, relative abundance, ionic charge state, stability toward dissociation, and electron binding energies of the IL clusters. Complementary global optimization theory provides molecular-level insights into the bonding and electronic structure of a selected subset of clusters, including their low energy structures and electrostatic potential maps, and how these fundamental characteristics are influenced by anion substitution. Collectively, our findings demonstrate how the fundamental properties of ILs, which determine their suitability for many applications, may be tuned by substituting counterions. These observations are critical in the sub-nanometer cluster size regime where phenomena do not scale predictably to the bulk phase, and each atom counts toward determining behavior.

cluster↗

Analysis strategy for ultrafast X-ray photon correlation spectroscopy

We explain an analysis strategy for ultrafast X-ray photon correlation spectroscopy, a technique enabled by X-ray free electron lasers to probe nano- and atomic-scale dynamics in complex systems on nanosecond timescales or faster. Central to the technique is the methodology for extracting contrast in coherent X-ray diffraction patterns, known as speckle patterns. Guided by simulations, we analyze common challenges and examine errors encountered in contrast extraction. A method for accurately determining contrast amid shot noise across a wide range of count rates is presented.

36 MATERIALS SCIENCE↗

Exploring the Electrochemical Stability Window of an All-Solid-State Composite Cathode via a Novel Operando Tender XPS Setup

All-solid-state batteries (ASSBs) have the potential to provide greater energy density than conventional batteries based on liquid electrolytes. Here, an operando ASSB cell setup for tender X-ray photoelectron spectroscopy (XPS) was developed, and the interface of a Ni-rich layered transition metal oxide cathode active material (CAM) and an Li 6 PS 5 Cl (LPSCl) solid electrolyte (SE) was evaluated during initial charge/discharge cycles. After validating the cell performance against a conventional pouch cell operated at high compression, intermittent galvanostatic cycling was performed, and XPS data were recorded as a function of state of charge (SOC). Upon the initial charge of the cell to ≈3.3 V Li , the LPSCl appears to decompose into LiCl, Li 3 PS 4 , and polysulfides, whose amount gradually increases with potential. Upon further charge, at a potential higher than ≈3.8 V Li , initially, present sulfate and sulfite impurities decompose, and at ≈74% SOC (corresponding to a cathode potential of ≈4.10 V Li ), surface reconstruction of the CAM particles due to lattice oxygen release is detected. In addition, at potentials beyond ≈4.6 V Li , a decrease of the S 1s counts of the sum of the LPSCl, the thiophosphate, and polysulfide species suggests the formation of elemental sulfur that is lost via sublimation into the vacuum chamber.

25 ENERGY STORAGE↗

Practical guide to understanding goodness-of-fit metrics used in chemical state modeling of x-ray photoelectron spectroscopy data by synthetic line shapes using nylon as an example

Chemical state analysis of a sample surface through fitting bell-shaped curves to x-ray photoelectron spectroscopic polymer data is reviewed using nylon to introduce and discuss aspects of data analysis. Different strategies for modeling chemistry in nylon spectra are presented and in so doing, a case is made to include in published science the design logic and implementation in terms of line shapes and optimization parameter constraints between components in a peak model. Imperfections in line shape relative to the true shape for photoemission lines, when compensated for using constraints to optimization parameters, are shown to provide chemical state information about a sample that justify, for peak models constructed with these limitations, metrics for goodness-of-fit different from those expected for pulse-counted data.

Materials Science↗

Microspheres

Vital information on a person's physical condition can be obtained by identifying and counting the population of T-cells and B-cells, lymphocytes of the same shape and size that help the immune system protect the body from the invasion of disease. The late Dr. Alan Rembaum developed a method for identifying the cells. The method involved tagging the T-cells and B-cells with microspheres of different fluorescent color. Microspheres, which have fluorescent dye embedded in them, are chemically treated so that they can link with antibodies. With the help of a complex antibody/antigen reaction, the microspheres bind themselves to specific 'targets,' in this case the T-cells or B-cells. Each group of cells can then be analyzed by a photoelectronic instrument at different wavelengths emitted by the fluorescent dyes. Same concept was applied to the separation of cancer cells from normal cells. Microspheres were also used to conduct many other research projects. Under a patent license Magsphere, Inc. is producing a wide spectrum of microspheres on a large scale and selling them worldwide for various applications.

Source record↗

Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors

Optical ranging is a problem of estimating the round-trip flight time of a phase- or amplitude-modulated optical beam that reflects off of a target. Frequency- modulated, continuous-wave (FMCW) ranging systems obtain this estimate by performing an interferometric measurement between a local frequency- modulated laser beam and a delayed copy returning from the target. The range estimate is formed by mixing the target-return field with the local reference field on a beamsplitter and detecting the resultant beat modulation. In conventional FMCW ranging, the source modulation is linear in instantaneous frequency, the reference-arm field has many more photons than the target-return field, and the time-of-flight estimate is generated by balanced difference- detection of the beamsplitter output, followed by a frequency-domain peak search. This work focused on determining the maximum-likelihood (ML) estimation algorithm when continuous-time photoncounting detectors are used. It is founded on a rigorous statistical characterization of the (random) photoelectron emission times as a function of the incident optical field, including the deleterious effects caused by dark current and dead time. These statistics enable derivation of the Cramér-Rao lower bound (CRB) on the accuracy of FMCW ranging, and derivation of the ML estimator, whose performance approaches this bound at high photon flux. The estimation algorithm was developed, and its optimality properties were shown in simulation. Experimental data show that it performs better than the conventional estimation algorithms used. The demonstrated improvement is a factor of 1.414 over frequency-domainbased estimation. If the target interrogating photons and the local reference field photons are costed equally, the optimal allocation of photons between these two arms is to have them equally distributed. This is different than the state of the art, in which the local field is stronger than the target return. The optimal processing of the photocurrent processes at the outputs of the two detectors is to perform log-matched filtering followed by a summation and peak detection. This implies that neither difference detection, nor Fourier-domain peak detection, which are the staples of the state-of-the-art systems, is optimal when a weak local oscillator is employed.

Erkmen, Baris I.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

Towards a reliable assessment of charging effects during surface analysis: Accurate spectral shapes of ZrO 2 and Pd/ZrO 2 via X-ray Photoelectron Spectroscopy

X-ray Photoelectron Spectroscopy of large bandgap or insulating material surfaces relies on an effective mechanism that compensates for the emission (loss) of electrons by maintaining the material surface at a steady-state uniform potential. While a steady-state may be attained by utilizing an active compensation, such as low power electron emitting filament, there is the possibility that the surface potential is not uniform over the area analyzed, leading to peak shifts and incorrect spectral interpretation. Here, in this work, a spectral data processing method based on mapping the ZrO 2 and Pd/ZrO 2 surfaces utilizing photoemission peak binding energy is proposed, which provides information about the response of specific material surfaces to charge compensation. Spectromicroscopy of ZrO 2 and Pd/ZrO 2 surfaces without spatial information is used to monitor the efficacy of charge compensation. Exploiting counts distributed over many bins require the use of procedures and algorithms essential to practical mapping peak positions. Iterative singular value decomposition is therefore introduced and utilized as a means of efficiently delivering spatially resolved spectra from which binding energy for peaks is computed. The concepts developed in this work result in robust and accurate peak models of ZrO 2 and Pd/ZrO 2 that can be applied in XPS analysis of not only ZrO 2 but other large bandgap or insulating material surfaces. Supporting arguments for a peak model representing signal from Zr 3p and Pd 3d are developed within this work are presented.

36 MATERIALS SCIENCE↗

Photoluminescence characterization of polythiophene films incorporated with highly functional molecules such as metallophthalocyanine

The photoluminescence (PL) of conducting polymer polythiophene (PT) films incorporated with metallophthalocyanines (PcMs) such as CuPc, MgPc, FePc, Li{sub 2}Pc, and CoPc was studied by PL and time-correlated single photon counting (TCSPC) measurements. Polymer films were prepared by electrochemical polymerization and PcMs migrated into the polymer films by a diffusion method using acetonitrile or toluene as a solvent to dissolve the PcMs. The wavelength of PL emission peaks changed significantly depending on the solvent used in the doping process. Using acetonitrile, the observed PL emission peaks originated from the Q band, whereas they were assigned to the Soret band in the case of toluene. TCSPC measurements showed that PL emission took place through a ligand-ligand transition process when using acetonitrile because the average lifetimes were comparable and independent of the central metal ions for CoPc-, Li{sub 2}Pc-, and MgPc-doped polymer films. Conversely, using toluene, it was found that ligand-ligand emission occurred for Li{sub 2}Pc-, MgPc-, and FePc-doped films. To identify the cause of the drastic change in PL emission pattern, x-ray photoelectron spectroscopy measurements were obtained. A lower binding energy component appeared in the C 1s core-level spectra of acetonitrile-processed PcM-doped PT films, whereas this component shifted to higher energy and overlapped with the main peak for toluene-processed PcM-doped PT films. The lower binding energy component corresponded to photoelectrons due to the C atoms in the benzene rings of the ligand. Lower binding energy components also appeared in the N 1s core-level spectra of acetonitrile-processed PcM-doped PT films, and this component shifted to higher energy for toluene-processed PcM-doped PT films. These lower energy components were assigned to the core-level peaks due to the N atoms at the meso position bridging between pyrrole rings. This suggests that the electron charge at the N sites of the meso positions in toluene-processed films was smaller than in acetonitrile-processed ones. The changes in energy at benzene C sites and meso N sites suggest that the electronic states of the phthalocyanine in the toluene-processed films were porphyrin-like, so the Soret band became dominant in the PL emission spectrum.

36 MATERIALS SCIENCE↗

Energy Correlation among Three Photoelectrons Emitted in Core-Valence-Valence Triple Photoionization of Ne

The direct observation of triple photoionization involving one inner shell and two valence electrons is reported. The energy distribution of the three photoelectrons emitted from Ne is obtained using a very efficient multielectron coincidence method using the magnetic bottle electron spectroscopic technique. A predominance of the direct path to triple photoionization for the formation of Ne{sup 3+} in the 1s2s{sup 2}2p{sup 4} configuration is observed. It is demonstrated that the energy distribution evolves with photon energy and indicates a significant difference with triple photoionization involving only valence electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗