Search NASA⌕ Search

SEARCH · Search NASA

Results for “PI control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

System Identification of a DC-DC Buck Converter Based on Two-Channel Relay Method

This work presents a system identification approach based on a two-channel relay applied to a DC-DC buck converter operating in closed-loop with a PI controller to regulate its output voltage. The implemented two-relay method allows system identification while the system is running online. Moreover, the algorithm works in a closed-loop configuration while introducing a minimal perturbation in the converter's operation. The presented algorithm was used to identify the frequency response of the converter with no-prior knowledge about the system structure. Furthermore, the identified transfer function parameters has a good agreement with the mathematical model of the converter. Simulation results of the comparison between the switching model, mathematical model and the identified model are provided to validate the theoretical analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Phase-Angle Detection for Three-Phase Inverters in Asymmetrical Power Grids

This paper introduces a signal reformation based direct phase-angle detection (DPD-SR) technique for three-phase inverters supporting asymmetrical grids. Asymmetries in three-phase systems may happen because of unbalanced three-phase loads, which can lead to the voltage asymmetry at the terminals of grid-tied inverters. The proposed DPD-SR technique can detect the voltage phase-angle under asymmetrical conditions. The DPD-SR technique also offers precise and rapid phase-angle detection via signal reformation and trigonometric functions. In essence, the phase-angle detection is directly derived from the trigonometric properties of the line-line voltages, while signal reformation is implemented to handle asymmetrical voltages. The proposed method measures two line-line voltages and detects the phase-angle of a three-phase system under both symmetrical and asymmetrical conditions. Unlike classical phase-locked loop (PLL) techniques, DPD-SR does not need any closed-loop PI controller, which significantly reduces the complexity and the delay in detecting the phase-angle. In this paper, the efficacy of the proposed technique is examined in comparison with the state-of-the-art PLLs under asymmetrical conditions via a set of laboratory experiments. Here, the performance of the phase-angle detection is also tested as part of an inverter feeding an asymmetrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hadron Monitor Calibration System for NuMI

NuMI (Neutrinos at Main Injector) beamline at Fermi National Accelerator Laboratory provides neutrinos to various neutrino experiments. The hadron monitor consisting of a 5 by 5 array of ionization chambers is part of the diagnostics for the beamline. In order to calibrate the hadron monitor, a gamma source is needed. We present the status and progress of the development of the calibration system for the hadron monitor. The system based on Raspberry Pi controlled CNC system, motors, and position sensors would allow us to place the gamma source precisely to calibrate the signal gain of individual pixels. The ultimate outcome of the study is a prototype of the calibration system.

43 PARTICLE ACCELERATORS↗

Correction of Rolling Mill Mechatronic System to Limit Dynamic Loads

Regulation in the mechatronic system of a DUO-300 rolling mill is investigated. The dynamics of an electric drive with a predictive PI controller in the current loop is analyzed. Methods are proposed for damping of self-oscillation and decrease in dynamic loads within the mechatronic system.

42 ENGINEERING↗

Thermal Radiator Pointing for International Space Station

In order to provide thermal radiation environments that result in adequate beat rejection, the single-phase, liquid ammonia (NH3) heat rejection system on the International Space Station (ISS) requires that its two thermal radiator wings be dynamically rotated as the ISS travels through its orbit. This paper discusses the closed-loop, thermal radiator pointing system that is used on ISS to ensure adequate heat rejection by the radiators, while preventing freezing of the ammonia under low heat loads and cold-environmental conditions. Although initial designs used an open-loop approach for radiator pointing, concerns about performance robustness, algorithm complexity, memory requirements, and sustaining support drove the development of a more robust, simpler, closed-loop system. Hence, the challenge of the closed-loop system was to utilize existing sensors, actuators and computers to fit into the existing hardware and software architecture of the ISS. Using a proportional-integral (PI) control architecture with limited output and an anti-windup integrator, the temperature of the ammonia coming out of the radiator is measured and controlled by adjusting the radiator wing orientation. The radiator wing orientation for the local minimum environment is fed forward to the control system, and the closed-loop controller is used to generate a bias off of that local minimum environment in order to heat up the ammonia when necessary to avoid freezing. In the earth's shadow, the controller is suspended and the radiator wing is oriented to face the earth, the local maximum thermal environment which further prevents freezing of the ammonia. This control architecture is shown to provide adequate heat rejection and avoid freezing of the ammonia, even though the physical system consists of large transport delays and time-varying dynamics which change dramatically due to orbit motion and variable heat loads.

Green, Scott↗

LQG and Feedforward Controllers for the Deep Space Network Antennas

The controller development and the tracking performance evaluation for NASA's Deep Space Network antenna are presented. A trajectory preprocessor, LQG (Linear Quadratic Gaussian) controller, feedforward controller, and their combination are designed, built, analyzed, and tested.

Deep Space Network (DSN)antennas feedforward contr↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High-Speed Z-Axis MEMS STM Nanopositioner

Scanning tunneling microscope (STM) is a powerful and versatile tool, not only capable of obtaining topographic information at atomic levels from a conductive surface, but also suited for patterning, manipulation and other applications, all with unprecedented precision. A typical STM’s operation relies on the quantum tunneling phenomenon. Providing a few angstroms of tip-sample separation, and a bias voltage between the two, a tunneling current (TC) is established. The tunneling current is logarithmically proportional to the tip sample separation . During imaging, a three degree of freedom (DOF) piezotube is employed to scan the tip over the surface, while a PI controller drives the Z axis in order to maintain the tunneling current at the set value. Therefore, an image of the sample surface can be constructed using the Z axis controller output, along with the corresponding X, and Y coordinates from the piezotube. Despite its well-established use in high precision applications, the achievable scan speed of the conventional STM has remained limited since its advent. One of the main reasons limiting the achievable scan speed is the relatively low operation bandwidth of the bulky piezotube Z-axis positioner, which is typically less than 1 kHz in conventional systems . This limitation correspondingly hinders the ability of the Z-axis controller to rapidly respond to the changes in the topography during the scan. To address this limitation, we design, build and characterize a high-bandwidth, 1-DOF nanopositioner with an electrostatic parallel plate actuation mechanism and a conductive tip, to replace the Z axis of the currently available STM piezotubes (Figure 1). The device is microfabricated using an SOI wafer with two device layers, where the top-most layer is designated for the tunneling current sensing, and contains the conductive tip realized by FIB induced deposition. The bottom device layer, on the other hand, comprises the actuation mechanism along with the shuttle and mechanical flexures, that provides 2-µm displacement range in one direction, comparable to a typical STM piezoelectric tube scanner. Importantly, the nanopositioner is structurally designed to have a -3dB bandwidth of 15.6 kHz, increasing the STM positioners’ Z axis bandwidth more than an order of magnitude as experimentally shown in Figure 2. Using this system we were able to demonstrate that tunneling current can be successfully established on an HOPG sample in air and successfully maintained for over two minutes (Figures 3-4).

FIB↗

PI Loop Resonance Control for Dark Photon Experiment at 2 K Using a 2.6 GHz SRF Cavity

Two 2.6 GHz SRF cavities are being used for a dark photon search at the vertical test stand (VTS) in FNAL, for the second phase of the Dark SRF experiment. During testing at 2 K the cavities experience frequency detuning caused by microphonics and slow frequency drifts. The experiment requires that the two cavities have the same frequency within the cavity's bandwidth. These two cavities are equipped with frequency tuners consisting of three piezo actuators. The piezo actuators are used for fine-fast frequency tuning. A proportional-integral (PI) loop utilizing the three piezos on the emitter was used to stabilize the cavity frequency and match the receiver cavity frequency. The results from this implementation will be discussed. The integration time was also calculated via simulation.

43 PARTICLE ACCELERATORS↗

Implementing a Hardware Testbed Using 3-Level ANPC Software Defined Inverters for Fault Analysis of a Transmission Network

In this paper, we propose the implementation of a hardware testbed using 3-level active neutral point clamped (ANPC) software-defined inverters for fault analysis. A test case transmission network equipped with two grid forming (GFM) inverters and four resistive loads is considered in this research. Firstly, grid forming control laws including PI feedback control and droop control are implemented to operate the inverters in parallel. Then, we implement a fault ride-through (FRT) logic and perform a simulation of the test system by applying a three-phase fault. Simulation results show the effectiveness of the fault recovery algorithm upon clearance of the fault. Finally, a 3-level ANPC software-defined inverter is programmed with required control laws and characterized through various lab experiments.

3-level ANPC inverter↗

A Discrete-Time Average Model Based Predictive Control for Quasi-Z-Source Inverter

A discrete-time average model-based predictive control (DTA-MPC) is proposed for a quasi-Z-source inverter (qZSI). As a single-stage inverter topology, the qZSI regulates the dc-link voltage and the ac output voltage through the shoot-through (ST) duty cycle and the modulation index. Several feedback strategies have been dedicated to produce these two control variables, among which the most popular are the proportional–integral (PI)-based control and the conventional model-predictive control (MPC). However, in the former, there are tradeoffs between fast response and stability; the latter is robust, but at the cost of high calculation burden and variable switching frequency. Moreover, they require an elaborated design or fine tuning of controller parameters. The proposed DTA-MPC predicts future behaviors of the ST duty cycle and modulation signals, based on the established discrete-time average model of the quasi-Z-source (qZS) inductor current, the qZS capacitor voltage, and load currents. The prediction actions are applied to the qZSI modulator in the next sampling instant, without the need of other controller parameters’ design. A constant switching frequency and significantly reduced computations are achieved with high performance. Transient responses and steady-state accuracy of the qZSI system under the proposed DTA-MPC are investigated and compared with the PI-based control and the conventional MPC. Simulation and experimental results verify the effectiveness of the proposed approach for the qZSI.

42 ENGINEERING↗

Model Predictive Control-Based Dual-Mode Operation of an Energy-Stored Quasi-Z-Source Photovoltaic Power System

The energy-stored quasi-Z-source inverter (ES-qZSI) has attracted much attention for photovoltaic (PV) power generations, due to its capability to stabilize the PV power fluctuations with simple structure and other advantages of Z-source inverter. The improved dual-mode (DM) ES-qZSI is able to support all-weather operation even at night or cloudy days when PV power is extremely low. However, the traditional proportional–integral (PI) based control suffers from complicated controller design and poor dynamic response during mode transition, due to two sets of PI control required for the daytime and night operation modes. In order to overcome that, here in this article, we propose a model predictive control strategy for the DM-ES-qZSI PV power system. The system predictive models in both day and night operating modes are derived. The control strategy is disclosed to ensure high performance of the system, through calling the predictive models and defined cost functions of the two modes within a single control loop. Simulation and experiment are carried out to verify the effectiveness of the proposed control strategy.

14 SOLAR ENERGY↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

PTEN and PI-3 kinase inhibitors control LPS signaling and the lymphoproliferative response in the CD19+ B cell compartment

Pattern recognition receptors (PRRs), e.g. toll receptors (TLRs) that bind ligands within the microbiome have been implicated in the pathogenesis of cancer. LPS is a ligand for two TLR family members, TLR4 and RP105 which mediate LPS signaling in B cell proliferation and migration. Although LPS/TLR/RP105 signaling is well-studied; our understanding of the underlying molecular mechanisms controlling these PRR signaling pathways remains incomplete. Previous studies have demonstrated a role for PTEN/PI-3K signaling in B cell selection and survival, however a role for PTEN/PI-3K in TLR4/RP105/LPS signaling in the B cell compartment has not been reported. Herein, we crossed a CD19cre and PTEN{sup fl/fl} mouse to generate a conditional PTEN knockout mouse in the CD19+ B cell compartment. These mice were further crossed with an IL-14α transgenic mouse to study the combined effect of PTEN deletion, PI-3K inhibition and expression of IL-14α (a cytokine originally identified as a B cell growth factor) in CD19+ B cell lymphoproliferation and response to LPS stimulation. Targeted deletion of PTEN and directed expression of IL-14α in the CD19+ B cell compartment (IL-14+PTEN-/-) lead to marked splenomegaly and altered spleen morphology at baseline due to expansion of marginal zone B cells, a phenotype that was exaggerated by treatment with the B cell mitogen and TLR4/RP105 ligand, LPS. Moreover, LPS stimulation of CD19+ cells isolated from these mice display increased proliferation, augmented AKT and NFκB activation as well as increased expression of c-myc and cyclinD1. Interestingly, treatment of LPS treated IL-14+PTEN-/- mice with a pan PI-3K inhibitor, SF1126, reduced splenomegaly, cell proliferation, c-myc and cyclin D1 expression in the CD19+ B cell compartment and normalized the splenic histopathologic architecture. These findings provide the direct evidence that PTEN and PI-3K inhibitors control TLR4/RP105/LPS signaling in the CD19+ B cell compartment and that pan PI-3 kinase inhibitors reverse the lymphoproliferative phenotype in vivo. - Highlights: • First genetic evidence that PTEN controls LPS/TLR4 signaling in B lymphocytes. • Evidence that PTEN regulates LPS induced lymphoproliferation in vivo. • PI-3 kinase inhibitors block LPS induced lymphoproliferation in vivo.

60 APPLIED LIFE SCIENCES↗

A comparison between IMSC, PI and MIMSC methods in controlling the vibration of flexible systems

A comparative study is presented between three active control algorithms which have proven to be successful in controlling the vibrations of large flexible systems. These algorithms are: the Independent Modal Space Control (IMSC), the Pseudo-inverse (PI), and the Modified Independent Modal Space Control (MIMSC). Emphasis is placed on demonstrating the effectiveness of the MIMSC method in controlling the vibration of large systems with small number of actuators by using an efficient time sharing strategy. Such a strategy favors the MIMSC over the IMSC method, which requires a large number of actuators to control equal number of modes, and also over the PI method which attempts to control large number of modes with smaller number of actuators through the use of an in-exact statistical realization of a modal controller. Numerical examples are presented to illustrate the main features of the three algorithms and the merits of the MIMSC method.

Baz, A.↗

Concept Study of Robotic Camera-Based Foreign Object Detection for EV Wireless Charging

Wireless charging of an electric vehicle (EV) is an emerging charging technology promising convenient, autonomous, and highly efficient EV charging without requiring heavy gauge cables. However, due to the strong electromagnetic field created by this process that surrounds the wireless charger, the presence of foreign objects can detrimentally interact with it, thus affecting wireless power transfer (WPT) performance or leading to harmful and unwanted safety risks. This paper presents the results for a concept study on a robotic camera-based foreign object detection (FOD) system, as a supplement to the industry-existing overlapped FOD coil array method, for EV wireless charging. A Raspberry PI 4 control board and compatible Raspberry PI Camera Module 2 are used to implement camera-based object detection. The FOD program was developed using a state-of-the-art deep learning object detection model with the OpenCV and Pytorch library and is compatible with camera module hardware. A dry-run test with Raspberry PI and a camera module was conducted and the preliminary FOD function was verified. The feasibility assessment is also validated by comparing the performance of five existing state-of-the-art deep learning object detection models for vehicles, animals, persons, and metals subsets, respectively. Satisfactory performance on the benchmark datasets is observed by the tests, but further improvements are needed in future work when detecting small-sized metallic objects. A programable robotic car is also under development as ongoing work for carrying the Raspberry PI and camera module while moving for the maintenance process.

24 POWER TRANSMISSION AND DISTRIBUTION↗