Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Intelligent process development of foam molding for the Thermal Protection System (TPS) of the space shuttle external tank

A knowledge based system to assist process engineers in evaluating the processability and moldability of poly-isocyanurate (PIR) formulations for the thermal protection system of the Space Shuttle external tank (ET) is discussed. The Reaction Injection Molding- Process Development Advisor (RIM-PDA) is a coupled system which takes advantage of both symbolic and numeric processing techniques. This system will aid the process engineer in identifying a startup set of mold schedules and in refining the mold schedules to remedy specific process problems diagnosed by the system.

Bharwani, S. S.↗

Temperature sensitivity of Eppley broadband radiometers

Broadband radiometers manufactured by Eppley Laboratories Inc. are commonly used to measure irradiance from both ground-based and aircraft platforms. Namely, the pyranometer (Model PSP) measures irradiance in the .3 to 3.0 micron spectral region while the pyrgeometer (Model PIR) senses energy in the 4 to 50 micron region. The two instruments have a similar thermopile construction but different filters to achieve the appropriate spectral selection. During the fall of 1986, the First ISCCP (International Satellite Cloud Climatology Project) Regional Experiment (FIRE) commenced with the first cirrus Intensive Field Observation (IFO) conducted in Central Wisconsin. Due to the nature of this field project, pyranometers and pyrgeometers manufactured by Eppley were flown on NCAR's high altitude research aircraft, the Sabreliner. Inherent in the construction of these radiometers is temperature compensation circuitry designed to make the instrument sensitivity nominally constant over a temperature range from -20 to +40 C. Because the Sabreliner flew at high altitudes where temperatures were as cold as -70 C, it was necessary to determine the radiometers relative sensitivity to temperatures below -20 C and apply appropriate corrections to the FIRE radiation data set. A procedure to perform this calibration is outlined. It is meant to serve as a supplement to calibration procedures.

Smith, William L., Jr.↗

Simulation study of the ROMPS robot control system

This is a report presenting the progress of a research grant funded by NASA for work performed from June 1, 1993 to August 1, 1993. The report deals with the Robot Operated Material Processing System (ROMPS). It presents results of a computer simulation study conducted to investigate the performance of the control systems controlling the azimuth, elevation, and radial axes of the ROMPS and its gripper. Four study cases are conducted. The first case investigates the control of free motion of the three areas. In the second case, the compliant motion in the elevation axis with the wrist compliant device is studied in terms of position accuracy and impact forces. The third case focuses on the behavior of the control system in controlling the robot motion along the radial axis when pulling the pallet out of the rack. In the fourth case, the compliant motion of the gripper grasping a solid object under the effect of the gripper passive compliance is studied in terms of position accuracy and contact forces. For each of the above cases, a set of PIR gains will be selected to optimize the controller performance and computer simulation results will be presented and discussed.

Nguyen, Charles C.↗

California Space Grant Consortium

The organizational and administrative structure of the CaSGC has the Consortium Headquarters Office (Principal Investigator - Dr. John Kosmatka, California Statewide Director - Dr. Michael Wiskerchen) at UC San Diego. Each affiliate member institution has a campus director and an scholarship/fellowship selection committee. Each affiliate campus director also serves on the CaSGC Advisory Council and coordinates CMIS data collection and submission. The CaSGC strives to maintain a balance between expanded affiliate membership and continued high quality in targeted program areas of aerospace research, education, workforce development, and public outreach. Associate members are encouraged to participate on a project-by-project basis that meets the needs of California and the goals and objectives of the CaSGC. Associate members have responsibilities relating only to the CaSGC projects they are directly engaged in. Each year, as part of the CaSGC Improvement Plan, the CaSGC Advisory Council evaluates the performance of the affiliate and associate membership in terms of contributions to the CaSGC Strategic Plan, These CaSGC membership evaluations provide a constructive means for elevating productive members and removing non-performing members. This Program Improvement and Results (PIR) report will document CaSGC program improvement results and impacts that directly respond to the specific needs of California in the area of aerospace-related education and human capital development and the Congressional mandate to "increase the understanding, assessment, development and utilization of space resources by promoting a strong education base, responsive research and training activities, and broad and prompt dissemination of knowledge and technology".

Kosmatka, John↗

Improving the Optical Quality Factor of the WGM Resonator

Resonators usually are characterized with two partially dependent values: finesse (F) and quality factor (Q). The finesse of an empty Fabry-Perot (FP) resonator is defined solely by the quality of its mirrors and is calculated as F=piR(exp 1/2)/(1-R). The maximum up-to-date value of reflectivity R approximately equal to 1 - 1.6 x 10(exp -6) is achieved with dielectric mirrors. An FP resonator made with the mirrors has finesse F=1.9 x 10(exp 6). Further practical increase of the finesse of FP resonators is problematic because of the absorption and the scattering of light in the mirror material through fundamental limit on the reflection losses given by the internal material losses and by thermodynamic density fluctuations on the order of parts in 109. The quality factor of a resonator depends on both its finesse and its geometrical size. A one-dimensional FP resonator has Q=2 F L/lambda, where L is the distance between the mirrors and lambda is the wavelength. It is easy to see that the quality factor of the resonator is unlimited because L is unlimited. F and Q are equally important. In some cases, finesse is technically more valuable than the quality factor. For instance, buildup of the optical power inside the resonator, as well as the Purcell factor, is proportional to finesse. Sometimes, however, the quality factor is more valuable. For example, inverse threshold power of intracavity hyperparametric oscillation is proportional to Q(exp 2) and efficiency of parametric frequency mixing is proportional to Q(exp 3). Therefore, it is important to know both the maximally achievable finesse and quality factor values of a resonator. Whispering gallery mode (WGM) resonators are capable of achieving larger finesse compared to FP resonators. For instance, fused silica resonators with finesse 2.3 x 10(exp 6) and 2.8 x 10(exp 6) have been demonstrated. Crystalline WGM resonators reveal even larger finesse values, F=6.3 x 10(exp 6), because of low attenuation of light in the transparent optical crystals. The larger values of F and Q result in the enhancement of various nonlinear processes. Low-threshold Raman lasing, optomechanical oscillations, frequency doubling, and hyperparametric oscillations based on these resonators have been recently demonstrated. Theory predicts a possibility of nearly 10(exp 14) room-temperature optical Q-factors of optical crystalline WGM resonators, which correspond to finesse levels higher than 10(exp 9). Experiments have shown numbers a thousand times lower than that. The difference occurs due to media imperfections. To substantially reduce the optical losses caused by the imperfections, a specific, multi-step, asymptotic processing of the resonator is implemented. The technique has been initially developed to reduce microwave absorption in dielectric resonators. One step of the process consists of mechanical polishing performed after high temperature annealing. Several steps repeat one after another to lead to significant reduction in optical attenuation and, as a result, to the increase of Q-factor as well as finesse of the resonator which demonstrates a CaF2 WGM resonator with F greater than 10(exp 7) and Q greater than 10(exp 11).

Savchenkov, Anatoliy↗

Vehicle Technologies Program Results

The Vehicle Technologies Program's progress is closely monitored by both internal and external organizations. The Program's results are detailed in a wide range of documents and tools that can be accessed through the PIR website. Descriptions of these materials are provided on this program results page.

publications, progress reports, awards, retrospect↗

Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developed the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the World Infrared Standard Group Field Campaign Report

The standard to which broadband infrared irradiance radiometers (pyrgeometers) are compared is called the World Infrared Standard Group (WISG), maintained in Davos, Switzerland, at the World Radiation Center. WISG consists of four pyrgeometers that were calibrated using the absolute sky-scanning radiometer (ASR; Philipona 2001). The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility has recently adopted this as its standard and all Eppley precision infrared radiometer (PIR) pyrgeometers in ARM are currently being calibrated by transfer calibrations from WISG. Subsequently, the ASR has fallen out of operation, Julian Gröbner (2012) developed the infrared integrating sphere (IRIS) radiometer, and Ibrahim Reda (2012) developed the absolute cavity pyrgeometer (ACP). The IRIS and ACP make absolute measurements of broadband downwelling infrared irradiance using different approaches. These two instruments have been compared to each other and to the WISG (Gröbner et al. 2014). The two newer instruments agreed within about 1 Wm-2 with each other, but not with the WISG, which was 2-5 Wm-2 lower depending on the column water vapor loading. Consequently, a case for changing the current WISG has been made by Gröbner and Reda, basing their suggestion on a total of nine hours of simultaneous IRIS and ACP comparison data as well as data from 177 clear-sky nights between the IRIS and WISG radiometers from October 2009 to December 2013 (Gröbner et al. 2014). These findings were later confirmed during the second International Pyrgeometer Comparison (IPgC-II) held in September/October 2015 at Physikalisch-Meteorologisches Observatorium Davos (PMOD)/World Radiation Center (WRC), bringing the total to about 20 hours of simultaneous ACP and IRIS measurements spread across two years and five days, in the mountainous environment of Davos. For this campaign, the WISG evaluation team deployed several instruments for absolute infrared radiation measurements and pyrgeometers that have been tied to the original standard (ASR) to ARM’s Southern Great Plains (SGP) atmospheric observatory in the fall of 2017. The experiment was carried out in two phases in order to increase the probability of collecting measurements at a range of water vapor column values, to which the measurements have shown some dependence. Phase 1 of the deployment ran from October 15 to 28, and Phase 2 ran from November 26 to December 9. Four redundant IRIS and two redundant ACP made coincident measurements during this time (the ASR no longer being available for comparison). The link to the WISG was provided by two pyrgeometers calibrated relative to the WISG prior to the campaign at SGP and also measuring coincidently with the two absolute radiometers. In addition, three of the original pyrgeometers directly tied to the original ASR were deployed. (See Figure 1 for instrument setup.) The experiment took place in the fall when water vapor columns were expected to range below and above the 1-cm level that is crucial for ferreting out the water vapor dependence of these measurements that has been noted in Gröbner et al. 2014 and other measurements. An additional source of longwave radiation flux observations was provided by the atmospheric emitted radiance interferometer (AERI). The AERI measures downwelling spectral radiance from 3.3 to 19 μm with a calibration that is better than 1% of the ambient radiance (Knuteson et al. 2004), and so serves as a potential source of evaluation for the WISG. The AERI’s field of view is 2 degrees, and is directed towards zenith. Earlier ARM projects led by Tony Clough as part of the Broadband Heating Rate Profile (BBHRP) effort demonstrated how to derive longwave flux from these zenith radiance observations.

AERI, instrument calibration, Southern Great Plain↗

Understanding Occupancy Patterns in a Commercial Space

Heating, ventilation, and air conditioning (HVAC) is a prime source of energy consumption in the US. In 2006, approximately 35% of energy in the US was used for HVAC [1]. Usually building operators use a static schedule for controlling HVAC systems without having a deeper understanding of how many people use the building at different times of the day. In addition, HVAC systems operate by assuming maximum occupancy in each room, which leads to a significant energy waste, e.g., an HVAC system providing ventilation for 30 people when there are only 10 people in a room. Considering how many people use different rooms at different times of the day is very crucial for achieving building energy efficiency and providing occupant comfort. There have been several attempts to collect long term occupancy patterns from office buildings, e.g., Mitsubishi’s Electronic Research Lab (MERL) dataset [14] and Colorado School of Mines (CSMBB) dataset. However, PIR motion detectors are used in these projects for sensing occupancy and hence these datasets only reflect whether a room is occupied or not without revealing the actual person count. Similar datasets are also collected from households. Only a few datasets from commercial spaces capture actual person count, and even in these cases, the data collection period was very limited, e.g., in [3] only 5 days of occupancy data is collected as ground truth. We are the first to collect long term (9 months) occupancy data (people count) from an 11,000 square foot commercial office (second floor of Bosch Research and Technology Center Pittsburgh). In this paper, we outline some statistical results from our empirical study and explore their implications for saving energy.

42 ENGINEERING↗

Enhancing The Thermal Resistivity of Rigid Polyisocyanurate Foam Insulation

The development of rigid polyurethane foam insulation has garnered considerable attention because of its promising applications in the buildings and construction industry. Its low thermal conductivity makes it an attractive choice for improving energy performance in buildings. Current Rigid Polyurethane foams have thermal resistivity (R-value/in.) 5.5 to 6.5 h.ft2F/BTU/in.· that could be further improved by diminishing the heat transfer through the foam matrix. Nevertheless, minimizing both conduction (through gas and solid) and radiation simultaneously in porous solids is a significant challenge due to the trade-off between these two mechanisms. This study focuses on improving the R-value of the insulation foams via several strategies: such as type and the amount of the surfactants, blowing agent content and precooling and premixing polyol mixture. These methods optimized thermal properties of the PIR foams, achieving R/in. as high as 8.3. This excellent R/in. is anticipated to be a critical factor in significantly advancing the thermal insulation performance of rigid polyurethane cellular foams, thereby enhancing their efficacy in energy-efficient building applications.

Wanasinghe Mudiyanselage Pahala Gedara, Shiwanka V↗

Energy Retrofit Field Study and Best Practices in a Hot-Humid Climate

Energy efficiency improvement as a component of comprehensive renovation was investigated under U.S. Department of Energy (DOE) funding of the Building America Partnership for Improved Residential Construction (BA-PIRC). Researchers at the Florida Solar Energy Center (FSEC) worked with affordable housing partners renovating foreclosed homes built from the 1950's through the 2000's in the hot-humid climate (within the Southern census region), primarily in Florida. Researchers targeted a 30% improvement in whole-house energy efficiency along with the health and safety, durability, and comfort guidelines outlined in DOE's Builders Challenge Program (Version 1) Quality Criteria.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bioenergy Technologies Office Multi-Year Program Plan: July 2014

This is the May 2014 Update to the Bioenergy Technologies Office Multi-Year Program Plan, which sets forth the goals and structure of the Office. It identifies the research, development, demonstration, and deployment activities the Office will focus on over the next five years and outlines why these activities are important to meeting the energy and sustainability challenges facing the nation.

09 BIOMASS FUELS↗