Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Self-calibration performance in stereoscopic PIV acquired in a transonic wind tunnel

Three stereoscopic PIV experiments have been examined to test the effectiveness of self-calibration under varied circumstances. Furthermore, we our measurements taken in a streamwise plane yielded a robust self-calibration that returned common results regardless of the specific calibration procedure, but measurements in the crossplane exhibited substantial velocity bias errors whose nature was sensitive to the particulars of the self-calibration approach. Self-calibration is complicated by thick laser sheets and large stereoscopic camera angles and further exacerbated by small particle image diameters and high particle seeding density. In spite of the different answers obtained by varied self-calibrations, each implementation locked onto an apparently valid solution with small residual disparity and converged adjustment of the calibration plane. Thus, the convergence of self-calibration on a solution with small disparity is not sufficient to indicate negligible velocity error due to the stereo calibration.

47 OTHER INSTRUMENTATION↗

Pulse-Burst PIV of an Impulsively Started Cylinder in a Shock Tube for Re > 10 5

Here, the impulsive start of a circular cylinder in a shock tube was characterized with time-resolved particle image velocimetry measurements (TR-PIV) using a pulse-burst laser. Three Reynolds numbers Re of 1.07 × 10 5 , 1.63 × 10 5 and 2.46 × 10 5 were studied adding insight into the transient process in the vicinity of the drag crisis. One symmetric vortex pair was shed from the cylinder at the lower Reynolds number prior to the wake going asymmetric in a fashion analogous to studies at lower Re. At Re ≥ 1.63 × 10 5 , two or more symmetric vortex pairs occurred prior to asymmetry and the eventual transition to a von Kármán vortex street. The non-dimensional rise time for vortex shedding to begin, as quantified by wavelet analysis, was found to be lower at the two higher Re. Finally, the study indicates a transformation in the impulsive wake to occur at Re near the critical regime and may serve as a benchmark for high Re numerical solutions.

42 ENGINEERING↗

Unsteady velocity field measurements at the outlet of an automotive supercharger using particle image velocimetry (PIV)

Particle image velocimetry (PIV) was used to study air flow characteristics at the outlet of an automotive supercharger. Instantaneous velocity fields were analyzed to yield ensemble-averaged velocities and Reynolds stresses, and the ensemble-averages were used to determine maximum velocity and exit flow angle as a function of blade position for various speeds and pressure ratios. The results show that the flow exits the supercharger as a high-speed jet that not only varies in the parallel plane but also in the perpendicular plane, generating a complex three-dimensional flow. The flow varies in the magnitude and the angle at which it leaves the supercharger with the change in blade position and follows a periodic behavior. The maximum velocity at which the flow exits the supercharger also follows a periodic behavior with a variation of 25-30% observed for all the cases. In the parallel plane, the exit angles are periodic every 60 deg of blade rotation and vary by as much as 40 deg, whereas periodic behavior with every 120 deg of blade rotation and a variation of 60 deg is observed in the perpendicular plane. Variation in flow with blade position is also observed in the velocity and turbulence profiles, with periodic behavior with every 60 blade rotation. The velocity and velocity fluctuation profiles show that the unsteady nature of the flow is most significant close to the outlet, and these unsteady variations diminish 58 mm downstream of the outlet. An exit flow pattern of a figure 8 is generated as the flow leaves the blades with one complete blade rotation of 120 for all the cases, except 4000 rpm, pressure ratio 1.4, where the flow exits in a circular pattern. (author)

33 ADVANCED PROPULSION SYSTEMS↗

PIV, 2D-LIF and 1D-Raman measurements of flow field, composition and temperature in premixed gas turbine flames

Several laser diagnostic measurement techniques have been applied to study the lean premixed natural gas/air flames of an industrial swirl burner. This was made possible by equipping the burner with an optical combustion chamber that was installed in the high-pressure test rig facility at the DLR Institute of Combustion Technology in Stuttgart. The burner was operated with preheated air at various operating conditions with pressures up to p = 6 bar and a maximum thermal power of P = 1 MW. The instantaneous planar flow field inside the combustor was studied with particle image velocimetry (PIV). Planar laser induced fluorescence (PLIF) of OH radicals on a single-shot basis was used to determine the shape and the location of the flame front as well as the spatial distribution of reaction products. 1D laser Raman spectroscopy was successfully applied for the measurement of the temperature and the concentration of major species under realistic gas turbine conditions. Results of the flow field analysis show the shape and the size of the main flow regimes: the inflow region, the inner and the outer recirculation zone. The highly turbulent flow field of the inner shear layer is found to be dominated by small and medium sized vortices. High RMS fluctuations of the flow velocity in the exhaust gas indicate the existence of a rotating exhaust gas swirl. From the PLIF images it is seen that the primary reactions happened in the shear layers between inflow and the recirculation zones and that the appearance of the reaction zones changed with flame parameters. The results of the multiscalar Raman measurements show a strong variation of the local mixture fraction allowing conclusions to be drawn about the premix quality. Furthermore, mixing effects of unburnt fuel and air with fully reacted combustion products are studied giving insights into the processes of the turbulence-chemistry interaction. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the flow field inside flat-plate collector tube using PIV technique

The thermofluid process inside the tube of flat-plate collectors is complex because the non-uniform heating of the tube results in the formation of stably and unstably stratified layers of fluid that interact with each other. The measurement and investigation of the flow behaviour inside the collector tube is very challenging. We report on a novel application of the particle image velocimetry (PIV) technique to remotely measure the velocity field inside the collector tube. The two-dimensional velocity fields were measured in the midplane of a collector tube for the Reynolds number range of 150-900 at unheated and four different heating conditions. We have presented and discussed in detail the technique implementation and the associated challenges. The results have shown that the collector heating significantly alters the structure and magnitude of the mean velocity field and influences the heat transfer to the fluid. It is observed that the collector heating causes a significant asymmetry in the mean velocity profiles over the given range of Reynolds numbers and heating conditions. (author)

14 SOLAR ENERGY↗

Domain architecture and oligomerization properties of the paramyxovirus PIV 5 hemagglutinin-neuraminidase (HN) protein

The mechanism by which the paramyxovirus hemagglutinin-neuraminidase (HN) protein couples receptor binding to activation of virus entry remains to be fully understood, but the HN stalk is thought to play an important role in the process. We have characterized ectodomain constructs of the parainfluenza virus 5 HN to understand better the underlying architecture and oligomerization properties that may influence HN functions. The PIV 5 neuraminidase (NA) domain is monomeric whereas the ectodomain forms a well-defined tetramer. The HN stalk also forms tetramers and higher order oligomers with high {alpha}-helical content. Together, the data indicate that the globular NA domains form weak intersubunit interactions at the end of the HN stalk tetramer, while stabilizing the stalk and overall oligomeric state of the ectodomain. Electron microscopy of the HN ectodomain reveals flexible arrangements of the NA and stalk domains, which may be important for understanding how these two HN domains impact virus entry.

60 APPLIED LIFE SCIENCES↗

HIGH RESOLUTION EXPERIMENTAL MEASUREMENTS OF RICHTMYER-MESHKOV TURBULENCE IN FLUID LAYERS AFTER RESHOCK USING SIMULTANEOUS PIV-PLIF

True ensemble-averaged density self-correlation and Reynolds stress turbulence statistics in a Richtmyer-Meshkov unstable fluid layer after reshock are measured for the first time using simultaneous Particle-Image Velocimetry (PIV)-Planar Laser-Induced Fluorescence (PLIF) diagnostic. These high-quality experiments with advanced diagnostics provide important insights into the physics of RM turbulence that cannot be obtained using simple shadowgraphy or Schlieren diagnostics. The double peaked nature of the density self-correlation and the asymmetric character of the Reynolds stress distributions are discussed. Error estimates and convergence rates for several turbulence quantities are also provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temporal evolution of scalar modes in Richtmyer–Meshkov instability of inclined interface using high-speed PIV and PLIF measurements at 60 kHz

Abstract The current work presents simultaneous, high-speed measurements at 60,000 fields per second of velocity and mole fraction using particle image velocimetry (PIV) and planar laser induced acetone-fluorescence in a Richtmyer–Meshkov instability of an inclined interface (Atwood number, At = 0.22). Specifically, around 2 ms of temporal evolution of the vortex structures and their associated scalar modes immediately following the interface-reshock interaction is presented. Two initial interface conditions are discussed—(a) a sharp, inclined ‘single mode’ interface and (b) a ‘multi-mode’ interface where small perturbations are imposed on the single mode case. A 2D wavelet decomposition of the scalar flow field shows a highly intermittent distribution of small-scale variance throughout the interface even at late times. These are correlated strongly with the vortex structures and local turbulence intensity, where each small-scale scalar mode is sandwiched between two co-rotating vortex structures. This indicates that the interstitial regions between the vortices are significant hotspots of entrainment, which is then dispersed by the induced, counter-flow velocity fields. The multimode case demonstrates similar organization at large scales, while the scalar field is much more homogeneous at smaller scales. These observations highlight the importance of capturing the early time vortex evolution to accurately estimate any late time intermittency, especially where deposition of intense vorticity on sharp interfaces is present.

Engineering↗

Review of “Deepwater Horizon Release Estimate of Rate by PIV”

The Plume Calculation Team (PCT) conducted high quality work within a very short period of time, in spite of needing to use less than ideal quality videos provided by British Petroleum (BP), especially those made before the cutoff of the riser above the Blow Out Preventer (BOP) on June 3, 2010. There are at least two valid approaches for estimating the oil discharge coming out from the Deepwater Horizon broken pipeline and its riser, using BP videotapes. One method is to estimate the exit velocity directly with the use of the Particle Image Velocimetry (PIV). The second method is to use a buoyant plume analysis to determine the exit velocity. The PCT used both of these methods.

02 PETROLEUM↗

Particle displacement tracking for PIV

A new Particle Imaging Velocimetry (PIV) data acquisition and analysis system, which is an order of magnitude faster than any previously proposed system has been constructed and tested. The new Particle Displacement Tracing (PDT) system is an all electronic technique employing a video camera and a large memory buffer frame-grabber board. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine velocity vectors. Application of the PDT technique to a counter-rotating vortex flow produced over 1100 velocity vectors in 110 seconds when processed on an 80386 PC.

Wernet, Mark P.↗

Ground-based PIV and numerical flow visualization results from the surface tension driven convection experiment

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the United States Microgravity Laboratory-1 (USML-1) Spacelab mission planned for June, 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electric, two dimensional Particle Image Velocimetry (PIV) technique called Particle Displacement Tracking (PDT), which uses a simple space domain particle tracking algorithm. Results using the ground based STDCE hardware, with a radiant flux heating mode, and the PDT system are compared to numerical solutions obtained by solving the axisymmetric Navier Stokes equations with a deformable free surface. The PDT technique is successful in producing a velocity vector field and corresponding stream function from the raw video data which satisfactorily represents the physical flow. A numerical program is used to compute the velocity field and corresponding stream function under identical conditions. Both the PDT system and numerical results were compared to a streak photograph, used as a benchmark, with good correlation.

Pline, Alexander D.↗

Ground-based PIV and numerical flow visualization results from the Surface Tension Driven Convection Experiment

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the United States Microgravity Laboratory-1 (USML-1) Spacelab mission planned for June, 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electric, two dimensional Particle Image Velocimetry (PIV) technique called Particle Displacement Tracking (PDT), which uses a simple space domain particle tracking algorithm. Results using the ground based STDCE hardware, with a radiant flux heating mode, and the PDT system are compared to numerical solutions obtained by solving the axisymmetric Navier Stokes equations with a deformable free surface. The PDT technique is successful in producing a velocity vector field and corresponding stream function from the raw video data which satisfactorily represents the physical flow. A numerical program is used to compute the velocity field and corresponding stream function under identical conditions. Both the PDT system and numerical results were compared to a streak photograph, used as a benchmark, with good correlation.

Pline, Alexander D.↗

Probabilistic Extraction Of Vectors In PIV

Probabilistic technique for extraction of velocity vectors in particle-image velocimetry (PIV) implemented with much less computation. Double-exposure photograph of particles in flow illuminated by sheet of light provides data on velocity field of flow. Photograph converted into video image then digitized and processed by computer into velocity-field data. Velocity vectors in interrogation region chosen from magnitude and angle histograms constructed from centroid map of region.

Humphreys, William M., Jr.↗

Application of PIV to the Measurement of High Speed Jet Flows

The Particle Image Velocimetry, PIV, has been implemented for the investigation of high-speed jet flows at the NASA Langley Research Center. In this approach the velocity (displacement) is found as the location of a peak in the correlation map of particle images acquired in quick succession. In the study, the technique for the correct seeding of the flow field were developed and implemented and the operational parameters influencing the accuracy of the measurement have been optimized.

Lourenco, L.↗

Using 3-D PIV in Laboratory Impact Experiments

Three Dimensional Particle Imaging Velocimetry (3D PIV) tested at the NASA AVGR provides a revolutionary new strategy for exploring impact phenomena in laboratory experiments.

Schultz, P. H.↗

Application of Three-Component PIV to a Hovering Rotor Wake

The key to accurate predictions of rotorcraft aerodynamics, acoustics, and dynamics lies in the accurate representation of the rotor wake. The vortical wake computed by rotorcraft CFD analyses typically suffer from numerical dissipation before the first blade passage. With some a priori knowledge of the wake trajectory, grid points can be concentrated along the trajectory to minimize the dissipation. Comprehensive rotorcraft analyses based on lifting-line theory rely on classical vortex models and/or semi-empirical information about the tip vortex structure. Until the location, size, and strength of the trailed tip vortex can be measured over a range of wake ages, the analyses will continue to be adjusted on a trial and error basis in order to correctly predict blade airloads, acoustics, dynamics, and performance. Using the laser light sheet technique, tip vortex location can be acquired in a straightforward manner. Measuring wake velocities and vortex core size, however, has been difficult and tedious using point-measurement techniques such as laser velocimetry. Recently, the Particle Image Velocimetry (PIV) technique has proven to be an efficient method for acquiring velocity measurements over relatively large areas and volumes of a rotor wake. The work reported to date, however, has been restricted to 2-component velocity measurements of the rotor wake. Three-component velocity measurements of a hovering rotor wake were acquired at NASA Ames Research Center in May 1999. This experiment represents a major step toward understanding the detailed structure of a rotor wake. This paper will focus primarily on the experimental technique used in acquiring this data. The accuracy and limitations of the current technique will also be discussed. Representative velocity field measurements will be included.

Yamauchi, Gloria K.↗

PIV Measurements in the 14 x 22 Low Speed Tunnel: Recommendations for Future Testing

During the period from February 4 to March 21, 2003 stereo digital particle imaging velocimetry measurements were made on a generic high lift model, the Trap Wing, as part of the High Lift Flow Physics Experiment. These measurements were the first PIV measurements made in the NASA, Langley Research Center 14 x 22 Foot Low Speed Tunnel, and several problems were encountered and solved in the acquisition of the data. It is the purpose of this paper to document the solutions to these problems and to make recommendations for further improvements to the tunnel/setup in order to facilitate future measurements of this type.

Watson, Ralph D.↗

Development of PIV for Microgravity Diffusion Flames

Results are presented from the application of Particle Image Velocimetry(PIV) to the overfire region of a laminar gas jet diffusion flame in normal gravity. A methane flame burning in air at 0.98 bar was considered. The apparatus demonstrated here is packaged in a drop rig designed for use in the 2.2 second drop tower.

Greenberg, Paul S.↗