Plasma analyzer for the Pioneer Jupiter missions

A description is given of the NASA/Ames Research Center Plasma Probe on board the Jupiter Missions of the Pioneer 10 and 11 spacecraft. The instrument has two quadrispherical electrostatic analyzer units; one has high sensitivity and resolution and the other is capable of measuring large fluxes of solar wind particles. The two analyzer units measure particle energy-to-charge ratio, flux, and direction of flow for positive ions and electrons over the wide range of particle densities found in the solar wind during the Jupiter missions. Data formats in space and ground data processing, the NASA/Ames Research Center plasma probe calibration facility, and the instrument response functions are also described.

Mckibbin, D. D.↗

Femtosecond Probing of Plasma Wakefields and Observation of the Plasma Wake Reversal Using a Relativistic Electron Bunch

We show that a high-energy electron bunch can be used to capture the instantaneous longitudinal and transverse field structures of the highly transient, microscopic, laser-excited relativistic wake with femtosecond resolution. The spatiotemporal evolution of wakefields in a plasma density up ramp is measured and the reversal of the plasma wake, where the wake wavelength at a particular point in space increases until the wake disappears completely only to reappear at a later time but propagating in the opposite direction, is observed for the first time by using this new technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing Hohlraum Plasma Conditions by Neutronics From Fusion in the Hohlraum Volume

We propose a novel technique to measure the ion temperature in ignition scale hohlraums, namely by filling the hohlraum with DT gas. Quantifying the neutron production within the hohlraum volume (in space and time) will help measure the ion temperature. Varying the amount of cross beam energy transfer (CBET) is predicted to affect the ion temperature due to saturation effects. By varying CBET (via wavelength choices in the beams) we could monitor the DT production as a measure of this ion heating effect. Ion diffusion models in the simulations can also be tested in this manner.

Rosen, M. D.↗

A comparative study of electrical probe techniques for plasma diagnostics

Techniques for using electrical probes for plasma diagnostics are reviewed. Specific consideration is given to the simple Langmuir probe, the symmetric double probe of Johnson and Malter, the variable-area probe of Fetz and Oeschsner, and a floating probe technique. The advantages and disadvantages of each technique are discussed.

Szuszczewicz, E. P.↗

Final Report for completed IPP Project:"Development of Plasma Ablation for Soft Tissue and Bone Surgery"

ArthroCare is a medical device company that develops, manufactures, and markets an advanced surgical tool, a plasma electro-surgical system for cutting and removing tissue. The hand-held electrical discharge device produces plasma in a biocompatible conductive fluid and tissue to which it is applied during surgery. Its products allow surgeons to operate with increased precision and accuracy, limiting damage to surrounding tissue thereby reducing pain and speeding recovery for the patient. In the past, the design of ArthfoCare's plasma wands has been an empirical undertaking. One goal of this R&D program was to put the phenomena involved on a sound scientific footing, allowing optimization of existing plasma based electro-surgery system technology, and the design and manufacture of new and improved kinds of scalpels, in particular for the surgical cutting of bone. Another important related goal of the program was to develop, through an experimental approach, new plasma wand approaches to the cutting ('shaving') of hard bone tissue. The goals of the CRADA were accomplished - computer models were used to predict important parameters of the plasma discharge and the bone environment, and several different approaches to bone-shaving were developed and demonstrated. The primary goal of the project was to develop and demonstrate an atmospheric-pressure plasma tool that is suitable for surgical use for shaving bone in humans. This goal was accomplished, in fact with several different alternative plasma approaches. High bone ablation speeds were measured. The use of probes ('plasma wand' - the surgical tool) with moving active electrodes was also explored, and there are advantages to this method. Another important feature is that the newly-exposed bone surface have only a very thin necrosis layer; this feature was demonstrated. This CRADA has greatly advanced our understanding of bone removal by atmospheric pressure plasmas in liquid, and puts ArthroCare in a good position to develop the techniques for commercial (surgical) application.

43 PARTICLE ACCELERATORS↗

Space Experiments with Particle Accelerators (SEPAC)

Plans for SEPAC, an instrument array to be used on Spacelab 1 to study vehicle charging and neutralization, beam-plasma interaction in space, beam-atmospheric interaction exciting artificial aurora and airglow, and the electromagnetic-field configuration of the magnetosphere, are presented. The hardware, consisting of electron beam accelerator, magnetoplasma arcjet, neutral-gas plume generator, power supply, diagnostic package (photometer, plasma probes, particle analyzers, and plasma-wave package), TV monitor, and control and data-management unit, is described. The individual SEPAC experiments, the typical operational sequence, and the general outline of the SEPAC follow-on mission are discussed. Some of the experiments are to be joint ventures with AEPI (INS 003) and will be monitored by low-light-level TV.

Obayashi, T.↗

Cleaning of diamond nanoindentation probes with oxygen plasma and carbon dioxide snow

Diamond nanoindentation probes may perform thousands of indentations over years of service life. There is a broad agreement that the probes need frequent cleaning, but techniques for doing so are mostly anecdotes shared between experimentalists. In preparation for the measurement of the shape of a nanoindentation probe by a scanning probe microscope, cleaning by carbon dioxide snow jets and oxygen plasma was investigated. Repeated indentation on a thumbprint-contaminated surface formed a compound that was very resistant to removal by solvents, CO{sub 2} snow, and plasma. CO{sub 2} snow cleaning is found to be a generally effective cleaning procedure.

36 MATERIALS SCIENCE↗

Direct Vlasov simulations of electron-attracting cylindrical Langmuir probes in flowing plasmas

Current collection by positively polarized cylindrical Langmuir probes immersed in flowing plasmas is analyzed using a non-stationary direct Vlasov-Poisson code. A detailed description of plasma density spatial structure as a function of the probe-to-plasma relative velocity U is presented. Within the considered parametric domain, the well-known electron density maximum close to the probe is weakly affected by U. However, in the probe wake side, the electron density minimum becomes deeper as U increases and a rarified plasma region appears. Sheath radius is larger at the wake than at the front side. Electron and ion distribution functions show specific features that are the signature of probe motion. In particular, the ion distribution function at the probe front side exhibits a filament with positive radial velocity. It corresponds to a population of rammed ions that were reflected by the electric field close to the positively biased probe. Numerical simulations reveal that two populations of trapped electrons exist: one orbiting around the probe and the other with trajectories confined at the probe front side. The latter helps to neutralize the reflected ions, thus explaining a paradox in past probe theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical solutions for reliable triple probe measurements in magnetized plasmas

The triple probe method to obtain local, time-resolved measurements of density, electron temperature and plasma potential is investigated in detail. The difficulties in obtaining reliable measurements with this technique are discussed and overcome. These include phase delay errors, ion sheath expansion and limited bandwidth due to stray capacitance to ground. In particular, a relatively simple electronic circuit is described to strongly reduce stray capacitance. Measurements with the triple probe are presented in a plasma characterized by interchange-driven turbulence in the TORPEX device. The measured time-averaged and time-dependent, conditionally averaged parameters are cross-checked with other Langmuir probe based techniques, and show good agreement. Triple probe measurements show that electron temperature fluctuations are sufficiently large, such that the identification of plasma potential fluctuations with fluctuations of the floating potential is not a good approximation. Over a large radial region, the time-averaged fluctuation-induced particle flux can, however, be deduced from floating potential only. This is because the phase shift between density and electron temperature is close to zero there and temperature fluctuations do not give rise to a net radial particle transport.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metastable helium density probe for remote plasmas

Helium metastable atom density was spatially determined by a modified electrostatic probe in a remote plasma. The probe structure was similar to that of a guard ring probe. Opposite polarity voltages were applied to the inner probe and the guard ring to shield both electrons and ions from the vicinity of the inner probe. Therefore, the inner probe current is due to secondary electrons generated by the de-exciting helium metastable atom flux. The photoelectron current was removed by shielding and orienting the probe 90 deg. to the direction of the plasma-generated photon flux. Helium metastable atom density on the order of 10{sup 7} cm{sup -3} was measured. Limitations on the use of this technique are revealed by comparisons with simulated metastable distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation and implementation of an ion sensitive probe as a plasma potential diagnostic

An ion sensitive probe (ISP) is developed as a robust diagnostic for measuring plasma potentials ({Phi}{sub P}) in magnetized plasmas. The ISP relies on the large difference between the ion and electron gyroradii ({rho}{sub i}/{rho}{sub e}{approx}60) to reduce the electron collection at a collector recessed behind a separately biased wall distance {approx}{rho}{sub i}. We develop a new ISP method to measure the plasma potential that is independent of the precise position and shape of the collector. {Phi}{sub P} is found as the wall potential when charged current to the probe collector vanishes during the voltage sweep. The plasma potentials obtained from the ISP match {Phi}{sub P} measured with an emissive probe over a wide range of plasma conditions in a small magnetized plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗