Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATES, FLAT - STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of Heave Plate Topology on Reaction Forces

Multi-body wave energy converters often rely on "heave plates" to generate the reaction forces required for energy harvesting. However, the influence of threedimensional heave plate topology on these reaction forces is relatively unexplored in the literature. Using laboratory experiments, we investigate the reaction forces generated by three distinct heave plate topologies: A flat hexagonal plate, an open hexagonal-conic, and an enclosed hexagonalconic (i.e., interior cavity flooded with water). Though the flat plate is the least massive of the topologies, it generates the greatest total reaction force for nearly all experimental cases due to higher fluid force. Our results also demonstrate that the flat plate generally experiences the greatest force variability between the three topologies, especially during relatively large oscillations (KC greater than 2). Globally, force variability increases with the Keulegan Carpenter (KC) number. These results highlight the importance of heave plate topology on multi-body point wave energy converter performance.

heave plate↗

Wind heat transfer coefficient in solar collectors in outdoor conditions

Knowledge of wind heat transfer coefficient, h{sub w}, is required for estimation of upward losses from the outer surface of flat plate solar collectors/solar cookers. In present study, an attempt has been made to estimate the wind induced convective heat transfer coefficient by employing unglazed test plate (of size about 0.9 m square) in outdoor conditions. Experiments, for measurement of h{sub w}, have been conducted on rooftop of a building in the Institute campus in summer season for 2 years. The estimated wind heat transfer coefficient has been correlated against wind speed by linear regression and power regression. Experimental values of wind heat transfer coefficient estimated in present work have been compared with studies of other researchers after normalizing for plate length. (author)

14 SOLAR ENERGY↗

Heat Transfer Analysis of Solar Air Heating System for Different Tilt Angles

Solar Air Heater is a simple, cheap and most widely used for various applications such as textile industries, agricultural, desalination and space heating. Generally collectors are tilted so as to absorb maximum radiation, so it is necessary to calculate the optimum tilt angle to maximize the solar radiation falling on the collector area to gain maximum useful energy. The maximum solar radiation can be collected by using a tracking mechanism. Tracking systems are expensive and complicated in construction. The working operation of solar integrated tracking system is difficult. This paper presents the mechanism of evaluating the overall heat transfer coefficient of the solar air-heater at variable intensities and inlet velocities. The experimental setup is integrated with blower at inlet to the solar air heater in order to pump air at different velocities. The work focus on comparative study of solar air heating system for different tilt angles ranging from 250 to 600 and determines the overall heat transfer coefficient so as to find the optimum tilt angle of a solar flat plate collector.

14 SOLAR ENERGY↗

Three-flat test with plates in horizontal posture

Measuring flats in the horizontal posture with interferometers is analyzed in detail, taking into account the sag produced by gravity. A mathematical expression of the bending is provided for a plate supported at three unevenly spaced locations along the edge. It is shown that the azimuthal terms of the deformation can be recovered from a three-flat measuring procedure, while the pure radial terms can only be estimated. The effectiveness of the iterative algorithm for data processing is also demonstrated. Experimental comparison on a set of three flats in horizontal and upright posture is provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving Translation Models for Predicting the Energy Yield of Photovoltaic Power Systems. Cooperative Research and Development Final Report, CRADA Number CRD-13-526

The project under this CRADA will analyze field data of various flat-plate and concentrator module technologies and cell measurements at the laboratory level. The field data will consist of current versus voltage data collected over many years on a latitude tilt test bed for Si, CdTe, amorphous silicon, and CIGS technologies. The concentrator data will be for mirror- and lens-based module designs using multijunction cells. The laboratory data will come from new measurements of cell performance with systematic variation of irradiance, temperature and spectral composition. These measurements will be labor-intensive and the aim will be to cover the widest possible parameter space for as many different PV samples as possible. The data analysis will require software tools to be developed. These tools will be customized for use with the specific NREL datasets and will be unsuitable for commercial release. The tools will be used to evaluate different translation equations against NREL outdoor datasets.

14 SOLAR ENERGY↗

Collection of solid and gaseous samples to diagnose inertial confinement fusion implosions

Collection of representative samples of debris following inertial confinement fusion implosions in order to diagnose implosion conditions and efficacy is a challenging endeavor because of the unique conditions within the target chamber such as unconverted laser light, intense pulse of x-rays, physical chunks of debris, and other ablative effects. We present collection of gas samples following an implosion for the first time. High collection fractions for noble gases were achieved. We also present collection of solid debris samples on flat plate collectors. Geometrical collection efficiencies for Au hohlraum material were achieved and collection of capsule debris (Be and Cu) was also observed. Asymmetric debris distributions were observed for Au and Be samples. Collection of Be capsule debris was higher for solid collectors viewing the capsule through the laser entrance hole in the hohlraum than for solid collectors viewing the capsule around the waist of the hohlraum. Collection of Au hohlraum material showed the opposite pattern: more Au debris was collected around the waist than through the laser entrance hole. The solid debris collectors were not optimized for minimal Cu backgrounds, which limited the conclusions about the symmetry of the Cu debris. The quality of the data limited conclusions on chemical fractionation effects within the burning, expanding, and then cooling plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance studies on solar collector with grooved absorber tube configuration using aqueous ZnO–ethylene glycol nanofluids

Solar flat plate collector (SFPC) is regarded as one of the best renewable energy devices to acquire hot water for domestic usage. Though its theoretical efficiency is projected at higher scale, its conversion efficiency is observed to be low due to various collector losses. Hence, to achieve improved performance of collector different techniques for heat transfer augmentation in circular pipes can be adopted. Among passive and active techniques available, passive is preferred over active due to economics and saving in exergy. Hence, in the present study absorber tube configuration is modified with internal grooves in the collector setup to enhance the rate of heat transfer. Also, fluids dispersed with metal oxide particles provide an increase in thermal conductivity such that ZnO-based aqueous EG mixture nanofluid is used as working medium to analyze the performance of collector setup. Also, the change in heat transfer rate and temperature profile of grooved tubes under forced laminar conditions for different working fluids are compared and reported.

14 SOLAR ENERGY↗

Heat transfer in porous medium embedded with vertical plate: Non-equilibrium approach - Part A

Heat transfer in a porous medium embedded with vertical flat plate is investigated by using thermal non-equilibrium model. Darcy model is employed to simulate the flow inside porous medium. It is assumed that the heat transfer takes place by natural convection and radiation. The vertical plate is maintained at isothermal temperature. The governing partial differential equations are converted into non-dimensional form and solved numerically using finite element method. Results are presented in terms of isotherms and streamlines for various parameters such as heat transfer coefficient parameter, thermal conductivity ratio, and radiation parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Thin Plate Hydrodynamic Stability through a Combined Numerical Modeling and Experimental Effort

An experimental and computational effort was undertaken in order to evaluate the capability of the fluid-structure interaction (FSI) simulation tools to describe the deflection of a Missouri University Research Reactor (MURR) fuel element plate redesigned for conversion to lowenriched uranium (LEU) fuel due to hydrodynamic forces. Experiments involving both flat plates and curved plates were conducted in a water flow test loop located at the University of Missouri (MU), at conditions and geometries that can be related to the MURR LEU fuel element. A wider channel gap on one side of the test plate, and a narrower on the other represent the differences that could be encountered in a MURR element due to allowed fabrication variability. The difference in the channel gaps leads to a pressure differential across the plate, leading to plate deflection. The induced plate deflection the pressure difference induces in the plate was measured at specified locations using a laser measurement technique. High fidelity 3-D simulations of the experiments were performed at MU using the computational fluid dynamics code STAR-CCM+ coupled with the structural mechanics code ABAQUS. Independent simulations of the experiments were performed at Argonne National Laboratory (ANL) using the STAR-CCM+ code and its built-in structural mechanics solver. The simulation results obtained at MU and ANL were compared with the corresponding measured plate deflections.

97 MATHEMATICS AND COMPUTING↗

Effect of shell drilling stiffness on response calculations of rectangular plates and tubes of rectangular cross-section under compression.

This report considers the calculation of the quasi-static nonlinear response of rectangular flat plates and tubes of rectangular cross-section subjected to compressive loads using quadrilateralshell finite element models. The principal objective is to assess the effect that the shell drilling stiffness parameter has on the calculated results. The calculated collapse load of elastic-plastic tubes of rectangular cross-section is of particular interest here. The drilling stiffness factor specifies the amount of artificial stiffness that is given to the shell element drilling Degree of freedom (rotation normal to the plane of the element). The element formulation has no stiffness for this degree of freedom, and this can lead to numerical difficulties. The results indicate that in the problems considered it is necessary to add a small amount of drilling tiffness to obtain converged results when using both implicit quasi-statics or explicit dynamics methods. The report concludes with a parametric study of the imperfection sensitivity of the calculated responses of the elastic-plastic tubes with rectangular cross-section.

36 MATERIALS SCIENCE↗

Computational model of miniature pulsating heat pipes

The modeling work described herein represents Sandia National Laboratories (SNL) portion of a collaborative three-year project with Northrop Grumman Electronic Systems (NGES) and the University of Missouri to develop an advanced, thermal ground-plane (TGP), which is a device, of planar configuration, that delivers heat from a source to an ambient environment with high efficiency. Work at all three institutions was funded by DARPA/MTO; Sandia was funded under DARPA/MTO project number 015070924. This is the final report on this project for SNL. This report presents a numerical model of a pulsating heat pipe, a device employing a two phase (liquid and its vapor) working fluid confined in a closed loop channel etched/milled into a serpentine configuration in a solid metal plate. The device delivers heat from an evaporator (hot zone) to a condenser (cold zone). This new model includes key physical processes important to the operation of flat plate pulsating heat pipes (e.g. dynamic bubble nucleation, evaporation and condensation), together with conjugate heat transfer with the solid portion of the device. The model qualitatively and quantitatively predicts performance characteristics and metrics, which was demonstrated by favorable comparisons with experimental results on similar configurations. Application of the model also corroborated many previous performance observations with respect to key parameters such as heat load, fill ratio and orientation.

97 MATHEMATICS AND COMPUTING↗

Large Eddy Simulation of Heat Transfer Over In-Line Flat-Tube Array in Laminar and Turbulent Flows

This study presents a transient three-dimensional numerical study on fluid flow and heat transfer of flat-tube array using large eddy simulation (LES) covering both laminar and turbulent flow regimes. The simulations were performed in a rectangular region containing only one tube with periodic conditions specified on all boundaries. A staggered flat-plate array was first studied, and an existing solution was used for validation purpose. The numerical models were then applied to an in-line array composed of flat tubes with an aspect ratio of 0.25 and fixed tube spacings. By varying the in-flow velocity, the tube array was studied over a wide range of Reynolds number (600–12000). Temperature, velocity, and turbulent kinetic energy distributions as well as the interactions between them are presented and analyzed. Furthermore, the local heat transfer rate was analyzed along the various parts of the tube (leading edge, flat-top and wake or trailing-edge regions). Heat transfer correlation for each region of the tube and the entire tube array is proposed..

Taghizadeh, Salar↗

Scaling Analysis of Vortex Shedding Frequency between In line Plates

The Global Threat Reduction initiative (GTRI) was established by the National Nuclear Security Administration (NNSA) in 2004. One of the highlights of the program is to convert research and test reactors at home and abroad from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU) fuels. By switching directly from HEU to LEU, an LEU reactor produces fewer neutrons than an HEU reactor and in some cases; a direct switch from HEU to LEU results in the reactor being unable to achieve criticality. Under certain circumstances, criticality is achieved and the original neutron fluxes are restored with LEU fuel by adding more fuel elements to the core. Not all reactors, exemplified by the Advanced Test Reactor (ATR) at the Idaho National Lab (INL), have the luxury of simply adding more fuel to the core. In such cases, entirely new designs must be created and tested. The ATR utilizes plate type fuel. During the design and testing of the ATR fuel, vortex shedding was identified as potential source for experiment and fuel failure. For fuel conversion, elements must be tested in pile prior to the qualification of the new fuel design. For some test elements, the primary test plate is followed by a secondary handling plate. It is known that objects downstream influence the vortex shedding. While vortex shedding is an important and well-studied phenomenon, not only in the context of nuclear engineering, but in fields as diverse as aeronautical engineering and biology, there is a significant gap in the understanding of vortex shedding in regards to two bluff bodies in line direct line with one another. The study provides a scaling analysis of the frequency of vortex shedding for plates in line. The scaling analysis is then compared to numerical simulation of two in line plates. The study provided a scaling analysis and suggested parameter for determining the expected trends in the Strouhal number for a plate with some object downstream. The analysis made the consideration of differing length scales as the cause for a reduction in vortex shedding frequency as well as looked at the potential impact of boundary layer growth on vortex shedding for a flat plate. The comparison between the expected scaling and numerical data was less than ideal, but there are several potential causes. One of the biggest issues with the comparison is the uncertainty associated with the defect velocity. The frequency was well established in several cases, but the velocity was not always well established resulting in a larger uncertainty. In the cases where the velocity was near zero (i.e. b/d = 0.5), the uncertainty dominated since the corrected Strouhal number is divided by the defect velocity. The Reynolds numbers were not incredibly large, ranging from 350-1600. The low Reynolds numbers potentially undermine the principle assumption made in the scaling analysis, i.e. Reynolds number is negligibly small. Additionally, the exact definition of the 'reduced velocity' was never explicitly defined, merely inferred from the assumption that the x length scale and y length scale were in fact different. Another potential problem is the defect velocities in the lower Reynolds number cases were not much smaller than the free stream velocity. Further work needs to be done at higher Reynolds numbers and with more data points to ensure the assumptions made are valid as well as confirm the accuracy of the scaled relationship. (authors)

42 ENGINEERING↗

First Annual Report on Pulsed Thermal Tomography Nondestructive Evaluation of Additively Manufactured Reactor Materials and Components: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This report provides results of preliminary performance evaluation of PTT capability in detection of flaws in metallic structures, as well imaging complex geometry AM structures. Performance of PTT was investigated through modeling and experiments, Computer models of PTT were developed using COMSOL Heat Transfer module. Defects were modeled as cylindrical flat bottom holes (FBH), which is a common model of calibrated material flaws in thermal tomography experiments. Materials considered in this study include stainless steel 316 (SS316), stainless steel 304 (SS304), and Inconel 718. Theoretical analyses were conducted to validate inversion of simulated PTT data with COMSOL for a plate. Subsequently, 3D reconstructions were performed on COMSOL simulations for FBH, revealing a decrease in spatial resolution over depth due to thermal diffusion. The results of this study show that the performance of the inversion algorithm for detecting smaller defects depends strongly on the depth of the defect as well as the incident heat flux. The size of detectable defect was estimated by fitting a Gaussian function to surface temperature profile. The criteria for detectability was taken as 20mK noise equivalent temperature difference (NETD), which is currently the sensitivity limit of high-performance infrared cameras. It was determined through computer simulations that the smallest detectable FBH in SS316 has a 50µm diameter and is located 0.5mm below the plate surface. Preliminary experimental studies were performed to evaluate PTT performance in detecting calibrated flaws using metallic specimens with AM defects simulated as drilled-in FBH’s. High strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The diameters of FBH’s varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanical drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. Finally, PTT capability in imaging several AM structures fabricated from Inconel 718 (IN718) powder feedstock was investigated. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of AM IN718 nozzle plate and a particle filter plate. It was shown that PTT can scan through 2/3in-thick Inconel 718 plates in approximately 15s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages. The results demonstrate the capability of PTT in 3-D imaging of complex geometry AM structures. Intermediate results demonstrated in this report will be developed further to investigate detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Lateral Conduction in a Rectangular Fuel Plate and Optimum Stripe Widths for the OPAL Reactor

The impetus for this work is the Proliferation Resistance Optimization (PRO-X) program, which was created by the National Nuclear Security Administration (NNSA) of the US Department of Energy (DOE) to provide a framework for developing reactor designs that minimize the production of special nuclear materials while maximizing performance for peaceful uses. The Argentine company INVAP and Argonne National Laboratory collaborated to share knowledge and expertise regarding the thermal analysis of research reactors. Working together, they designed a series of test problems based on the Open Pool Australian Light Water (OPAL) reactor, whose fuel is in the form of flat plates cooled by water flowing through narrow rectangular channels. ANL used their PLTEMP/ANL code. INVAP used their TERMIC code (and its new multi-plate version, TERMIC-MP). Then, INVAP and ANL compared the two sets of results. 1-D models were used during the collaboration since for research reactor analysis, largely 1-D thermal-hydraulics models are commonly used because they are simple to apply and technically defendable. The collaboration between the two organizations aims for improvements in thermal-hydraulic models. Improvements to methods and models can reduce modeling uncertainties and excessive conservatism, allowing greater reactor performance without reducing predicted safety margins. Therefore, these improvements potentially expand the design space, making additional designs feasible, which, in turn, may achieve better fuel utilization and proliferation resistance in the designs. This report provides justification for the lateral node size (stripe width) chosen for the 1-D computer models during the collaboration. The lateral heat conduction in OPAL fuel plates is evaluated using the two-dimensional conduction capability of PLTEMP/ANL to determine a representative hot-stripe width that can be conservatively used for one-dimensional steady-state thermal-hydraulic analysis. Basically, a representative hot-stripe width needs to be selected so that the actual heat flux averaged over this stripe width is greater than or equal to the maximum heat flux obtained by the two-dimensional analysis. Detailed results in this report show that a hot-stripe width of 8.125 mm can be conservatively used for the one-dimensional thermal-hydraulics analysis of all plates. Therefore, eight equal stripes (8.125 mm each) are recommended to be modeled in the MCNP and PLTEMP/ANL full core models of the OPAL reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observer POD for radiographic testing

The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Corrugated Membrane Fuel Cell Structures

One of the most challenging aspects of traditional PEM fuel cell stacks is the difficulty achieving the platinum catalyst utilization target of 0.2 gPt/kWe set forth by the DOE. Good catalyst utilization can be achieved with state-of-the-art catalyst coated membranes (CCM) when low catalyst loadings (<0.3 mg/cm 2 ) are used at a low current. However, when low platinum loadings are used, the peak power density is lower than conventional loadings, requiring a larger total active area and a larger bipolar plate. This results in a lower overall stack power density not meeting the DOE target. By corrugating the fuel cell membrane electrode structure, Ion Power’s goal is to realize both the Pt utilization targets as well as the power density targets of the DOE. This will be achieved by demonstrating a fuel cell single cell (50 cm 2 ) with a twofold increase in the membrane active area over the geometric area of the cell by corrugating the MEA structure. The corrugating structure must be able to demonstrate the target properties of < 10 mOhm-cm 2 electrical resistance at > 20 psi compressive strength over the active area, in combination with offering at least 80% of power density that can be achieved by using the same MEA in a flat plate structure. Corrugated membrane fuel cell structures also have the potential to meet DOE power density targets by essentially packaging more membrane area into the same fuel cell volume as compared to conventional stack constructions.

08 HYDROGEN↗