Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLUTONIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

Electrothermal vaporization as a new method for pre-inspection check samples

The use of electrothermal vaporization (ETV) has not been readily applied to nuclear safeguards or pre inspection check (PIC) sample analysis, even though the technique is ideally suited for low level (pg) isotopic quantification due to its high analyte transport efficiency. Here demonstrate the ETV method for PIC safeguard analysis. The ETV system is an automated, commercial of the shelf (COTS) technology, with the capability to introduce solid samples to a mass spectrometer platform. The system has been shown to simultaneously determine uranium assay, and the major isotopic ratios for uranium and plutonium. The ETV unit has demonstrated analysis up to 50 samples a day autonomously. The utilization of this ETV methodology provide a secondary option to the current PIC analysis and offers high throughput, enhanced sensitivity, and broader isotopic detection platform.

Hexel, Cole↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Safeguards Technolgy Development Program FY2023 Mid-Year Report

We will develop specific aspects of ultra-high-resolution microcalorimetry that support IAEA NML needs in preparation for transfer of the technology. Two techniques will be considered: gamma spectroscopy for nondestructive isotopic analysis of milligram- to gram-scale uranium and plutonium samples, and decay energy spectroscopy (DES) for isotopic analysis of specially prepared nanogram- to microgram-scale samples of alpha decaying actinides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biofilm growth in water-cooling towers as collection platforms for airborne radionuclides

Given its history of nuclear material processing, the Savannah River Site (SRS) was used to evaluate whether biofilms growing in water-cooling towers (WCTs) are effective passive collection platforms for environmental radionuclide surveillance. Uranium and plutonium analyses suggest that WCT-sourced biofilms are efficient, indigenous, constantly running samplers that can be used for environmental monitoring, as their isotopic compositions are distinct from atmospheric fallout and representative of SRS historical activities. Further, the ubiquity of WCTs worldwide and demonstrated ability to detect nuclear material processing and constrain specific activities based on biofilm actinide isotopic compositions make WCT biofilms a promising means to improve monitoring.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Sub-Critical “Hands On” Demonstration [Slides]

Objectives: understand how the factors that affect criticality safety relate to working “hands on” with plutonium metal systems, including density, isotopic composition, moderating reflectors, absorbing reflectors. Understand the criticality safety implications for threshold fissioners.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

History of Pu-238 Production Restart Efforts at Idaho National Laboratory and Oak Ridge National Laboratory

In the early 2010s, efforts to restart production in the U.S. of plutonium-238 heat source (HSPu) material for NASA deep space missions were initiated. Processes, procedures, hardware, and chemical separations were developed and implemented to enable the production of heat source material at Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL). Here, this review provides an overview of the timeline and efforts associated with the restart of production, as well as upcoming efforts to increase production.

07 ISOTOPE AND RADIATION SOURCES↗

A new TEVA-DGA chromatography procedure to separate Pu, Am, and Np from bulk U materials

Trace actinides present within uranium (U) material are diagnostic signatures of U processing history. For example, the emplacement of U material within the high neutron-flux environment of a nuclear reactor can cause neutron capture of U to form 241-plutonium ( 241 Pu). Plutonium-241 then decays to progeny isotopes 241-americium ( 241 Am) and 237-neptunium ( 237 Np); therefore, the presence and relative abundances of these trace actinides is indicative of the material’s production history and intended employment (Mayer et al., 2013). During a pre-detonation nuclear forensics investigation, measurement of trace actinide 241 Pu, 241 Am, and 237 Np concentrations by an analytical laboratory may be requested. However, chemically purifying these elements from bulk U is a challenging and involved procedure requiring several sequential chromatography columns across 4+ days. To expedite Pu-Am-Np separation from bulk U material, and to improve the yield recovery of these elements, this DHS Postdoc Fellowship has worked to create a new chromatography separation chemistry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Isotopic Analysis using FRAM [Slides]

FRAM is an isotopic analysis code nominally designed for plutonium and uranium. It stands for Fixed-energy Response-function Analysis with Multiple efficiencies. It has self-calibration using several gamma-ray peaks and can analyze gamma ray data from 30keV to >1MeV of HPGe, CdTe, or LaBr3 detector. The key difference between the MGA family of codes (from LLNL) and FRAM is the use of user-editable analysis parameters in the latter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Risk Analysis of Radiological Release from Pu-238 Targets During Manual Handling

Pu-238 Isotope Production Targets are routinely installed in the Advanced Test Reactor (ATR) core, transferred, and stored in the spent fuel canal. These evolutions involve manual handling and manipulation of the targets underwater using long handled tools. The ATR Safety Analysis Report (SAR) postulates a design basis accident which results in damage from manual manipulation of targets, and radiological consequences must be determined for receptors inside the reactor facility, as well as public receptors. This presentation presents the analysis used to determine the radiological consequences due to potential target damage in the ATR canal. The analysis considered radionuclide release fractions, damage ratios for handling evolutions, and entrainment of radionuclides in the canal water.

Advanced Test Reactor↗

Protecting People and Planet

To produce energy, civilian nuclear power plants require fuel. The majority of existing plants rely on solid ceramic fuels that contain concentrations of about 3 to 5% of the element uranium-235. This specific isotope is well suited to sustaining the type of chain reaction required for a nuclear reactor to harness the heat produced by nuclear fission. Title I of the United States Atomic Energy Act of 1954 defines “special nuclear material” as plutonium, uranium-233, or uranium enriched in the isotopes uranium-233 or uranium-235. This label identifies materials that at high concentrations can be used to produce nuclear weapons. The United States and broader international community are fully committed to ensuring the peaceful use of nuclear energy by committing to practices known as safeguards.

99 GENERAL AND MISCELLANEOUS↗

Neptunium mononitride as a target material for Pu-238 production

Deep space exploration requires specialized sources for both thermal and power applications. Radioactive decay heat of plutonium-238 (238Pu) provides these sources in the form of radioisotope thermoelectric generators (RTGs). The 238 Pu is produced via neutron capture reaction involving neptunium-237 ( 237 Np) target material. Continual optimization of 237 Np target materials and evaluation of potential alternative targets for production of 238 Pu RTGs are advantageous for meeting ongoing space power system resource requirements. Current production of 238 Pu for RTGs for the United States space program utilizes neptunium dioxide ( 237 NpO 2 ) targets; however, the use of neptunium mononitride ( 237 NpN) presents an opportunity to increase the mass of 237 Np per target compared to the dioxide form, as well as increase the thermal conductivity of the target. To assess the viability of a 237 NpN target material, the material chemistry must be thoroughly evaluated, including synthesis methods and dissolution and reprocessing schemes. This review presents a summary of synthesis pathways for 237 NpN based on published literature on actinide mononitrides. Specific literature on 237 NpN is limited, necessitating evaluation of other actinide systems to gather parallels. This suggests a need for additional experimental studies on 237 NpN. A particular limitation in the existing literature is a lack of information on the differences in material characteristics, such as morphology, particle size, and trace chemical impurities, as a function of synthesis method. These parameters may affect subsequent reactor performance or dissolution of irradiated targets. The evaluation of existing literature is presented with a focus on the efficacy of 237 NpN targets for 238 Pu production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Combination of DGA and LN Columns: A Versatile Option for Isotope Production and Purification at Oak Ridge National Laboratory

The chromatographic resins DGA and LN have been used sequentially to separate curium, californium, plutonium, and various fission products (FPs) to obtain products with a pure radioisotope or a radioelement with high isotopic purity. This 2-step combination of resins has found applications in the 252 Cf and 238 Pu campaigns performed at Oak Ridge National Laboratory. Experiments have been carried out in glove boxes, shielded caves, and hot cells, demonstrating that these resins are adequate and maintain their performance in highly radiolytic environments. We find that using these resins has led to the recovery of curium highly enriched (>95%) in 248 Cm, the clean separation of 251 Cf for the superheavy element research, and the recovery of 147 Pm from the FP stream obtained during the 238 Pu production campaign while demonstrating that the raffinate post DGA is essentially free of transuranic elements.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating FRAM v.6.1 with LANL and Euratom data

The United States Department of Energy and the European Atomic Energy Community (EURATOM) collaborate to test, evaluate, and improve the performance of the FRAM 6.1 code with various nuclear materials, especially mixed oxide (MOX) containing an isotopic blend of uranium and very high burnup plutonium. This joint effort is intended to promote effective implementation of the FRAM 6.1 code into nuclear material verification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diversion Path Analysis: A Proposed Methodology to Develop an MC&A Approach for Liquid-Fueled Molten Salt Reactors

Nuclear material control and accounting (MC&A) is a critical element of both the US Nuclear Regulatory Commission (NRC) and US Department of Energy (DOE)’s domestic safeguards and security requirements. NRC licensees are required, under Title 10 of the Code of Federal Regulations (10 CFR) Part 74 to establish and maintain an MC&A program that captures and records the quantities and locations of special nuclear material (SNM) at the facility. Along with physical protection, MC&A is a key element of domestic nuclear material safeguards that enables the NRC to ensure that SNM is controlled and accounted for. SNM, per 10 CFR Part 74, refers to plutonium, 233 U, and uranium enriched in the isotope 233 U or 235 U, but does not include source material. Periodic physical inventories, coupled with material balance evaluations, are effective and demonstrated tools to account for and detect theft or diversion of SNM in facilities containing SNM in bulk material form (i.e., not in discrete, countable items). Historically in the United States, these types of facilities have included fuel fabrication, conversion, and enrichment facilities. In comparison, reactors have relied on item counting of assemblies and control of SNM while in containment (e.g., a sealed reactor pressure vessel) because, to date, reactor fuel has been in item form. In liquid-fueled molten salt reactors (MSRs), unlike traditional light water reactors (LWRs) or bulk facilities, bulk SNM quantities can change significantly during operation as a result of depletion and transmutation. This introduces challenges to the use of traditional periodic physical inventories and material balance evaluations to detect theft or diversion of SNM in reactors that use SNM in bulk material form. Liquid-fueled (i.e., salt-fueled) MSR facilities are MSRs that use SNM within a salt eutectic as the fuel. The SNM is in a bulk material form any time it is outside of fresh or spent fuel storage containers. Some examples of when SNM will be in bulk form in the facility are during addition of fuel to the reactor system, while fuel is circulating in operation, and while fuel is in a drain tank. Periodic physical inventories and material balance evaluations can likely be effectively applied to many portions of an MSR facility, including all areas where depletion and transmutation are not significantly changing the quantities of SNM within the control area. Within an MSR facility, this would include fresh fuel receipt and loading, waste streams that may contain SNM, irradiated fuel storage outside of the reactor core, and any irradiated fuel processing that may happen after SNM has been removed from the reactor. All of these process steps could rely on measurements of SNM quantities compared with documented inventories. Any discrepancies from predicted (i.e., book) inventories and measured inventories could be quantified as inventory differences, consistent with traditional MC&A guidance from the NRC (e.g., in NUREG-1065 Revision 2, NUREG-2159 Revision 1, and RG 5.29 Revision 2). Within the reactor system, additions and removals to the book inventory include depletion of the SNM (e.g., fission of 235 U), which complicates the use of physical inventories. SNM control, however, can also likely be effectively applied to detect theft of SNM throughout a liquid-fueled MSR facility. To complement these approaches, prior technical reports have identified that a diversion path analysis may be a useful, risk-informed, and performance-based tool to determine suitable elements of an MC&A approach for the reactor system within a liquid-fueled MSR facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Isotope Production for UK PhD Student Visit [Slides]

Overview of INL isotope production work, including organizational structures, the current work and future plans of plutonium fuel supplies, cobalt-60 production, and BRR cask shipping.

07 ISOTOPE AND RADIATION SOURCES↗