At least 91 records · Page 5

Approximation to the Probability Density at the Output of a Photmultiplier Tube

The probability density of the integrated output of a photomultiplier tube (PMT) is approximated by the Gaussian, Rayleigh, and Gamma probability densities. The accuracy of the approximations depends on the signal energy alpha: the Gamma distribution is accurate for all alpha, the Raleigh distribution is accurate for small alpha (approximate or less than 1 photon) and the Gaussian distribution is accurate for large alpha (approximate or greater than 10 photons).

Stokey, R. J.↗

A stochastic model for photon noise induced by charged particles in multiplier phototubes of the space telescope fine guidance sensors

The Space Telescope (ST) is subjected to charged particle strikes in its space environment. ST's onboard fine guidance sensors utilize multiplier phototubes (PMT) for attitude determination. These tubes, when subjected to charged particle strikes, generate spurious photons in the form of Cerenkov radiation and fluorescence which give rise to unwanted disturbances in the pointing of the telescope. A stochastic model for the number of these spurious photons which strike the photocathode of the multiplier phototube which in turn produce the unwanted photon noise are presented. The model is applicable to both galactic cosmic rays and charged particles trapped in the Earth's radiation belts. The model which was programmed allows for easy adaption to a wide range of particles and different parameters for the phototube of the multiplier. The probability density functions for photons noise caused by protons, alpha particles, and carbon nuclei were using thousands of simulated strikes. These distributions are used as part of an overall ST dynamics simulation. The sensitivity of the density function to changes in the window parameters was also investigated.

Howell, L. W.↗

Characteristics of the MSFC, PDS microdensitometer

The results of several parametric studies carried out on the Marshall Space Flight Center (MSFC) Photometric Data System PDS-10 microdensitometer are summarized for the purposes of documenting the operation and limitations of the system for inhouse research and to provide a bench mark for comparison with other microdensitometers. The results are grouped into four general areas. These are: (1) system overall stability to drift, (2) photometric linearity and noise, (3) reproducibility, and (4) scanning performance. Test data taken in order to evaluate the interdependency of scan speed, noise and position are included. Shown also are results of tests for system stability, reproducibility, stray light and PMT settling time.

Fountain, W. F.↗

A statistical model of the photomultiplier gain process with applications to optical pulse detection

A Markov diffusion model was used to determine an approximate probability density for the random gain. This approximate density preserves the correct second-order statistics and appears to be in reasonably good agreement with experimental data. The receiver operating curve for a pulse counter detector of PMT cathode emission events was analyzed using this density. The error performance of a simple binary direct detection optical communication system was also derived. Previously announced in STAR as N82-25100

Tan, H. H.↗

The solar vector magnetograph of the Okayama Astrophysical Observatory

The vector magnetograph of the Okayama Astrophysical Observatory is fed to the 65 cm solar coude telescope with a 10 m Littrow spectrograph. The polarimeter put at the telescope focus analyzes the incident polarization. Photomultipliers (PMT) at the exit of the spectrograph pick up the modulated light signals and send them to the electronic controller. The controller analyzes frequency and phase of the signal. The analyzer of the polarimeter is a combination of a single wave plate rotating at 40 Hz and a Wallaston prism. Incident linear and circular polarizations are modified at four times and twice the rotation frequency, respectively. Two compensators minimize the instrumental polarization, mainly caused by the two tilt mirrors in the optical path of the telescope. The four photomultipliers placed on the wings of the FeI 5250A line give maps of intensity, longitudinal field and transverse field. The main outputs, maps of intensity, and net linear and circular polarizations in the neighboring continuum are obtained by the other two monitor PMTs.

Makita, M.↗

Gating characteristics of photomultiplier tubes for Lidar applications

A detector test facility was developed and applied in the evaluation and characterization of lidar detectors in support of the multipurpose airborne differential absorption lidar (DIAL) system based at the Langley Research Center (LaRC). A performance data base of various detector configurations available to the DIAL system was obtained for optimum lidar detector selection. Photomultiplier tubes (PMT's) with multialkaline and bialkaline photocathodes were evaluated in voltage-divider networks (bases) by using either the focusing electrode or dynodes as a gating mechanism. Characteristics used for detector evaluation included gain stability, signal rise time, and the ability to block unwanted high light levels.

Barrick, J. D. W.↗

Stochastic model for photon noise induced by charged particles in multiplier phototubes of the Hubble Space Telescope fine guidance sensors

The Space Telescope (ST) is subjected to charged particle strikes in its space environment. ST's onboard fine guidance sensors utilize multiplier phototubes (PMT) for attitude determination. These tubes, when subjected to charged particle strikes, generate spurious photons in the form of Cerenkov radiation and fluorescence which give rise to unwanted disturbances in the pointing of the telescope. A stochastic model for the number of these spurious photons which strike the photocathodes of the multiplier phototube which in turn produce the unwanted photon noise are presented. The model is applicable to both galactic cosmic rays and charged particles trapped in the earth's radiation belts. The model which was programmed allows for easy adaption to a wide range of particles and different parameters for the phototube of the multiplier. The probability density functions for photons noise caused by protons, alpha particles, and carbon nuclei were using thousands of simulated strikes. These distributions are used as part of an overall ST dynamics simulation. The sensitivity of the density function to changes in the window parameters was also investigated.

Howell, L. W.↗

Vertical structure of Arctic haze observed by lidar

In the study of the Arctic Haze phenomenon, understanding the vertical structure of the haze aerosol is crucial in defining mechanisms of haze transport. Questions have also arisen concerning the representativeness of surface observations of Arctic Haze. Due to the strongly stratified nature of the Arctic troposphere, the mechanisms which transport aerosol to the surface from the transport altitudes of the lower troposphere are not obvious. In order to examine these questions, a Mie scattering lidar was installed at Alert, NWT, Canada. Lidar observes atmospheric aerosols and hydrymeteors as they appear in nature, unmodified by sampling effects. As such the results obtained are more realistic of the light scattering characteristics of the in situ aerosol than are those obtained by integrating nephelometers, for example, which heat the aerosol and dry it before measurement. With this lidar, a pulse was transmitted vetically through an evacuated tube in the roof of a building at Alert. The receiver consisted of a 20cm diameter Fresnel telescope, neutral density and polarizing filters, and RCA C31000A PMT, Analog Modules LA-90-P logarithmic amplifier and a Lecroy TR8827 32 MHz digitizer. The lidar equation was solved for the backscattering coefficient of the aerosol assuming no two way transmission losses in the signal. The lidar results have shown that intercomparison between lidar obtained visibilities and observer visibilities are in much better agreement than for other optical or aerosol monitors. Three new effects were identified in the lidar profiles which contribute to the vertical transport of haze. These effects are briefly discussed.

Hoff, R. M.↗

Pre-shuttle lidar system research

Included are the results of the initial phase of a simulation study in connection with photomultiplier tubes (PMT) and associated networks and an analytical study of atmospheric physics (including multiscattering) leading to modeling studies in connection with differential absorption lidar (DIAL) observations. This effort was in support of the ER-2 aircraft DIAL projects.

Lang, R. H.↗

Photon detection with cooled avalanche photodiodes

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5-3 times more sensitive than presently available photomultiplier tubes (PMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than twice that of a PMT were obtained with detector noise levels below 100 counts per second. Higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, D. L.↗

Cooled avalanche photodiode used for photon detection

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5 to 3 times more sensitive than presently-available photomultiplier tubes (PPMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than 25 percent were obtained with detector noise levels comparable to the noise of a PMT; higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, Deborah L.↗

Physical studies of small asteroids and cometary cores

The main goal of the research is to carry on an extensive study of physical properties (colors and variability) of asteroids in the 1 to 10 km diameter range and of cometary cores, with the use of a charge coupled device (CCD) camera, PMT photometer, or both. Particular attention is paid to asteroids being observed by radar because the greatest gain is found from the combination of radar results with the data obtained by optical techniques. To satisfy the goal, 100 nights/year have been scheduled on the 2.3 m and 1.5 m telescopes. During the past 2 years small asteroids were observed. Out of 22 asteroids for which periods of rotation could be precisely measured, 17 have periods of rotation less than 5 hours. This indicates that small objects rotate faster. By now researchers know 14 asteroids with rotation periods in the 2 hour range. At the same time they confirmed the existence of a number of exceptionally slow rotators e.g., 1367 Nongoma with P = 5.65 days. Taxonomic observations lead to a conclusion that Apollo, Amor, and Aten asteroids represent a variety of classes and are not predominantly of class S. Apollo asteroid 3361 Orpheus was found to belong to the rare class V. In collaboration with Dr A. Harris of JPL the opposition effect was studied for 30 Urania and 64 Angelina. Seven comets: P/Helin, P/Brooks 2, P/Klemola, P/Borrelly, Wilson (1986 1) and Shoemaker (1987 o) were monitored for variability. The results were negative with the exception of P/Brooks 2 for which 0.35 mag amplitude was detected.

Wisniewski, Wieslaw Z.↗

Computer-aided simulation study of photomultiplier tubes

A computer model that simulates the response of photomultiplier tubes (PMTs) and the associated voltage divider circuit is developed. An equivalent circuit that approximates the operation of the device is derived and then used to develop a computer simulation of the PMT. Simulation results are presented and discussed.

Zaghloul, Mona E.↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

One Year of Rayleigh Lidar Measurements at Toronto

The Rayleigh lidar technique is being used at York University to study middle atmospheric thermal structure with particular emphasis on the properties and influence of internal gravity waves. These measurements are now carried out on a routine basis (every clear night) in order to determine seasonal variability and, eventually, long term trends. The transmitter consists of a doubled Nd:YAG laser with an output of 0.4 Joules per pulse at 20Hz (8 Watts) which is expanded to obtain a divergence of 0.4 milliradians. Backscattered photons are collected by a half meter cassegrain telescope, filtered to a bandwidth of 1nm, detected by a PMT, and counted with a multi-channel scaling averager. Strong backscatter from lower altitudes is blocked using a rotating chopper (25000rpm) which triggers the laser. The range gate and hardware averaging interval are variable but typically 300m and 5 minutes. Relative density profiles are obtained by simply normalizing to a model (eg. CIRA) at some altitude. Absolute temperature is derived using the hydrostatic equation, ideal gas law, and a model pressure value at the altitude where the photocount statistical uncertainty is about 15 percent - typically 90km for the entire night's average. The lower limit is currently about 30-35km due the presence aerosol from the volcanic eruption of Mt. Pinatubo.

Whiteway, James A.↗

Reduced electrical bandwidth receivers for direct detection 4-ary PPM optical communication intersatellite links

One of the major sources of noise in a direct detection optical communication receiver is the shot noise due to the quantum nature of the photodetector. The shot noise is signal dependent and is neither Gaussian nor wide sense stationary. When a photomultiplier tube (PMT) or an avalanche photodiode (APD) is used, there is also a multiplicative excess noise due to the randomness of the internal photodetector gain. Generally speaking, the radio frequency (RF) communication theory cannot be applied to direct detection optical communication systems because noise in RF communication systems is usually additive and Gaussian. A receiver structure which is mathematically optimal for signal dependent shot noise is derived. Several suboptimal receiver structures are discussed and compared with the optimal receiver. The objective is to find a receiver structure which is easy to implement and gives close to optimal performance.

Davidson, Frederic M.↗

Geoscience Laser Ranging System design and performance predictions

The Geoscience Laser System (GLRS) will be a high-precision distance-measuring instrument planned for deployment on the EOS-B platform. Its primary objectives are to perform ranging measurements to ground targets to monitor crustal deformation and tectonic plate motions, and nadir-looking altimetry to determine ice sheet thicknesses, surface topography, and vertical profiles of clouds and aerosols. The system uses a mode-locked, 3-color Nd:YAG laser source, a Microchannel Plate-PMT for absolute time-of-flight (TOF) measurement (at 532 nm), a streak camera for TOF 2-color dispersion measurement (532 nm and 355 nm), and a Si avalanche photodiode for altimeter waveform detection (1064 nm). The performance goals are to make ranging measurements to ground targets with about 1 cm accuracy, and altimetry height measurements over ice with 10 cm accuracy. This paper presents an overview of the design concept developed during a phase B study. System engineering issues and trade studies are discussed, with particular attention to error budgets and performance predictions.