Development and Amputee Validation of Pressure and Shear Sensing Liner for Prosthetic Sockets.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
No abstract prepared.
The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.
The presence of chaos in walking is considered to provide a stable, yet adaptable means for locomotion. This study examined whether lower limb amputation and subsequent prosthetic rehabilitation resulted in a loss of complexity in amputee gait. Twenty-eight individuals with transtibial amputation participated in a 6 week, randomized cross-over design study in which they underwent a 3 week adaptation period to two separate prostheses. One prosthesis was deemed “more appropriate” and the other “less appropriate” based on matching/mismatching activity levels of the person and the prosthesis. Subjects performed a treadmill walking trial at self-selected walking speed at multiple points of the adaptation period, while kinematics of the ankle were recorded. Bilateral sagittal plane ankle motion was analyzed for underlying complexity through the pseudoperiodic surrogation analysis technique. Results revealed the presence of underlying deterministic structure in both prostheses and both the prosthetic and sound leg ankle (discriminant measure largest Lyapunov exponent). Results also revealed that the prosthetic ankle may be more likely to suffer loss of complexity than the sound ankle, and a “more appropriate” prosthesis may be better suited to help restore a healthy complexity of movement within the prosthetic ankle motion compared to a “less appropriate” prosthesis (discriminant measure sample entropy). Results from sample entropy results are less likely to be affected by the intracycle periodic dynamics as compared to the largest Lyapunov exponent. Adaptation does not seem to influence complexity in the system for experienced prosthesis users.
Recently, significant advances in robotics have led to increased use in industrial and military applications. For example, the military has used explosive ordnance disposal (EOD) robots to enable responders to remotely investigate hazardous environments. While EOD robots have saved many lives, their utility is hampered by: 1) limited ability to manipulate complex objects and mechanisms (e.g. open a car door, operate power tools or turn valves), and 2) the requirement for significant operator training using joystick-type interfaces. Most robots today have simplistic manipulators and cannot easily operate in environments designed for humans as evidenced by the recent Amazon Picking Challenge and the DARPA Robotics Challenge. Simple tasks that humans perform easily, such as picking up objects or operating a cutting tool, require customized rigs that are expensive and time-consuming to use. The specialized nature of these robots limits their utility in highly unstructured environments, for example during emergency situations where a robot may need to be rapidly re-purposed for an unanticipated situation (i.e. the Fukushima nuclear disaster). Robots are needed that can perform complex human-like tasks and are easy to use for everyday and emergency tasks. In 2005 the Defense Advanced Research Projects Agency (DARPA) initiated the Revolutionizing Prosthetics (RP) Program with the goal of creating prosthetics as capable as the human arm and a human-machine interface enabling highly intuitive operation. The Johns Hopkins University Applied Physics Laboratory (JHU/APL) created the Modular Prosthetic Limb (MPL), originally developed for amputees and paralyzed individuals as part of the RP Program, to replicate the capability of the human hand and arm to the extent technologically possible. With 26 joints and over 180 sensors, it is one of the most sophisticated and fully integrated robotic arms in the world. We have also demonstrated human-machine interface techniques that are highly intuitive requiring minimal training. While the MPL was originally designed as a prosthetic, it has also been incorporated into mobile robotic systems to project human capability. Using tele-operation, we have demonstrated the ability to perform dual-arm remote operations in complex environments. For nuclear facilities, high dexterity robots combined with tele-operation offer the potential to enhance worker safety, productivity and quality. Safety enhancements include enabling remote operation in hazardous environments, remote handling of heavy or dangerous materials, and elimination of injury due to repetitive motions. Because the MPL is designed to function like a human limb, the robot can work in environments designed for humans with limited need for specialized tools. When used for routine operations, it can also maintain a level of familiarity and confidence that effectively accomplishes reinforcement training for use in emergency situations, unlike a specialized robot that might sit unused for months or years at a time. In August 2016 we demonstrated the use of the MPL at the Portsmouth Gaseous Diffusion Plant in Piketon, Ohio. Two robotic platform technologies were demonstrated to familiarize the DOE Emergency Management's (EM) workforce on the potential benefits of this technology. Here we present the results of those efforts, highlight the lessons learned during 'EM Week,' and outline potential future developments that could further advance application of these technologies to enhance worker safety. (authors)
Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.
Implantable peripheral nerve cuffs have a large application in neuroprostheses as they can be used to restore sensation to those with upper limb amputations. Modern day prosthetics, while lessening the pain associated with phantom limb syndrome, have limited fine motor control and do not provide sensory feedback to patients. Sensory feedback with prosthetics requires communication between the nervous system and limbs, and is still a challenge to accomplish with amputees. Establishing this communication between the peripheral nerves in the arm and artificial limbs is vital as prosthetics research aims to provide sensory feedback to amputees. Peripheral nerve cuffs restore sensation by electrically stimulating certain parts of the nerve in order to create feeling in the hand. Cuff electrodes have an advantage over standard electrodes as they have high selective stimulation by bringing the electrical interface close to the neural tissue in order to selectively activate targeted regions of a peripheral nerve. In order to further improve the selective stimulation of these nerve cuffs, there is need for finer spatial resolution among electrodes. One method to achieve a higher spatial resolution is to increase the electrode density on the cuff itself. Microfabrication techniques can be used to achieve this higher electrode density. Using L-Edit, a layout editor, microfabricated peripheral nerve cuffs were designed with a higher electrode density than the current model. This increase in electrode density translates to an increase in spatial resolution by at least one order of magnitude. Microfabricated devices also have two separate components that are necessary to understand before implantation: lifetime of the device and assembly to prevent nerve damage. Silicone molding procedures were optimized so that devices do not damage nerves in vivo, and lifetime testing was performed on test microfabricated devices to determine their lifetime in vivo. Future work of this project would include fabricating some of the designed devices and seeing how they compare to the current cuffs in terms of their electrical performance, lifetime, shape, and mechanical properties.
The design criteria for an optimum prosthetic-aortic leaflet valve are a smooth washout in the valve cusps, minimal leaflet stress, minimal transmembrane pressure for the valve to open, an adequate lifetime (for a given blood-compatible leaflet material's fatigue data). A rigorous design analysis is presented to obtain the prosthetic tri-leaflet aortic valve leaflet's optimum design parameters. Four alternative optimum leaflet geometries are obtained to satisfy the criteria of a smooth washout and minimal leaflet stress. The leaflet thicknesses of these four optimum designs are determined by satisfying the two remaining design criteria for minimal transmembrane opening pressure and adequate fatigue lifetime, which are formulated in terms of the elastic and fatigue properties of the selected leaflet material - Avcothane-51 (of the Avco-Everett Co. of Massachusetts). Prosthetic valves are fabricated on the basis of the optimum analysis and the resulting detailed engineering drawings of the designs are also presented in the paper.
An approximation method and system are provided for more quickly controlling a prosthetic or other device by reducing computational processing time in a muscle model that can be used to control the prosthetic. For a given muscle, the approximation method can quickly compute polynomial structures for a muscle length and for each associated moment arms, which may be used to generate a torque for a joint position of a physics model. The physics model, in turn, produces a next joint position and velocity data for driving a prosthetic. The approximation method expands the polynomial structures as long as expansion is possible and sufficiently beneficial. The computations can be performed quickly by expanding the polynomial structures in a way that constrains the muscle length polynomial to the moment arm polynomial structures, and vice versa.
The purpose of this study was to share our initial experience with the AMPLATZER Vascular Plug (AVP) in occluding dialysis accesses. Between January 2007 and October 2008, five patients with autogenous and one patient with prosthetic accesses were referred for endovascular occlusion owing to central venous obstruction (n = 4) and dialysis-associated steal syndrome (n = 2) leading to disabling complications. We used a single AVP in two patients, double AVPs in two patients, and double AVPs and n-butyl 2-cyanoacrylate in one patient with an autogenous access. Two coils were deployed between two AVPs to occlude the prosthetic graft. Immediate success was achieved in all patients, with no complications. Mean follow-up time was 13 months (range, 1-21 months) and none of the patients had experienced symptom recurrence as of the time of writing. The AVP allows simple, precise, and reliable dialysis access occlusion without significant complications when surgical ligation is not preferred. It can be used with other embolizing agents to provide occlusion in the case of failure.
Background: The current diagnosis of infective endocarditis (IE) is based on the modified Duke criteria, which has approximately 80% sensitivity for the diagnosis of native valve endocarditis (NVE), with lower sensitivity for the diagnosis of prosthetic valve endocarditis (PVE) and culture-negative endocarditis. There is preliminary evidence that {sup 18}F-FDG PET/CT is an adjunctive diagnostic test with high accuracy reported in small studies to date. We therefore performed a meta-analysis of studies evaluating the use of PET/CT in the diagnosis of IE to establish a more precise estimate of accuracy. Methods: PubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov were searched from January 1990 to April 2017 for studies evaluating the accuracy of PET/CT for the evaluation of possible IE. Results: We identified 13 studies involving 537 patients that were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of IE was 76.8% (95% CI 71.8–81.4%; Q = 39.9, P < 0.01; I{sup 2} = 69.9%) and the pooled specificity was 77.9% (95% CI 71.9–83.2%; Q = 44.42, P < 0.01; I{sup 2} = 73.0%). Diagnostic accuracy was improved for PVE with sensitivity of 80.5% (95% CI 74.1–86.0%; Q = 25.5, P < 0.01; I{sup 2} = 72.5%) and specificity of 73.1% (95% CI 63.8–81.2%; Q = 32.1, P < 0.01; I{sup 2} = 78.2%). Additional extracardiac foci of infection were found on 17% of patients on whole body PET/CT. Conclusion: PET/CT is a useful adjunctive diagnostic tool in the evaluation of diagnostically challenging cases of IE, particularly in prosthetic valve endocarditis. It also has the potential to detect clinically relevant extracardiac foci of infection, malignancy, and other sources of inflammation leading to more appropriate treatment regimens and surgical intervention.
Highlights: • Gö6983 rescued Ti particle-induced osteolysis in a murine calvarial model. • Gö6983 inhibits osteoclast formation. • Gö 6983 suppresses osteoclast hydroxyapatite resorption and osteoclastic gene expression. • Gö 6983 blocks NF-κB/JNK/P38 signaling pathways of osteoclast. • Gö6983 does not affect osteoblast differentiation and osteoblast-associated gene expression in vitro. Osteoclast activation by wear particles has caused major difficulties for surgeons. Wear particles are the main causes of aseptic prosthetic loosening. Gö6983, a protein kinase C inhibitor, inhibits five subtypes of protein kinase C family members. Here, we found that Gö6983 had an obviously inhibitory effect on wear-particles-induced osteolysis in vivo. In vitro, Gö6983 inhibited RANKL-stimulated osteoclast formation and function by inhibiting the RANKL-stimulated nuclear factor-κB/JNK/p38 signaling pathway. We also observed that Go6983 had no effect on the differentiation of osteoblasts and osteoblast-associated genes expression. According to our data, Gö6983 has potential therapeutic effects for aseptic prosthetic loosening caused by osteoclast activation.
Essential to cells and their organelles, water is both shuttled to where it is needed and trapped within cellular compartments and structures. Moreover, ordered waters within protein structures often colocalize with strategically placed polar or charged groups critical for protein function, yet it is unclear if these ordered water molecules provide structural stabilization, mediate conformational changes in signaling, neutralize charged residues, or carry out a combination of all these functions. Structures of many integral membrane proteins, including G protein-coupled receptors (GPCRs), reveal the presence of ordered water molecules that may act like prosthetic groups in a manner quite unlike bulk water. Identification of 'ordered' waters within a crystalline protein structure requires sufficient occupancy of water to enable its detection in the protein's X-ray diffraction pattern, and thus, the observed waters likely represent a subset of tightly bound functional waters. In this review, we highlight recent studies that suggest the structures of ordered waters within GPCRs are as conserved (and thus as important) as conserved side chains. In addition, methods of radiolysis, coupled to structural mass spectrometry (protein footprinting), reveal dynamic changes in water structure that mediate transmembrane signaling. The idea of water as a prosthetic group mediating chemical reaction dynamics is not new in fields such as catalysis. However, the concept of water as a mediator of conformational dynamics in signaling is just emerging, because of advances in both crystallographic structure determination and new methods of protein footprinting. Although oil and water do not mix, understanding the roles of water is essential to understanding the function of membrane proteins.
The synthesis, recrystallization, and X-ray deterimination of N , N , N -trimethyl-5-[(2,3,5,6-tetrafluorophenoxy)carbonyl]pyridin-2-aminium trifluoromethanesulfonate (PyTFP-precursor), C 15 H 13 F 4 N 2 O 2 + ·CF 3 SO 3 - , is described. This triflate salt precursor is required for the synthesis of 2,3,5,6-tetrafluorophenyl 6-[ 18 F]-fluoronicotinate ([ 18 F]FPyTFP), a prosthetic group used to radiolabel peptides for positron emission tomography (PET), as peptides are increasingly being used as PET-imaging probes in nuclear medicine. Radiolabeling of peptides is typically done using a `prosthetic group', a small synthon to which the radioisotope is attached in the first step, followed by attachment to the peptide in the second step. During the synthesis of the PyTFP-precursor, displacement of a Cl atom with trimethylamine gas and anion replacement with a triflate counter-ion is critical, as incomplete replacement would hinder radioisotopic incorporation of nucleophilic fluorine-18 and result in diminished radiochemical yields. The structural determination of the PyTFP-precursor by X-ray crystallography helped confirm the anion exchange of chloride with triflate.