Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTOCOLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Assessing the Effect of a Contouring Protocol on Postprostatectomy Radiotherapy Clinical Target Volumes and Interphysician Variation

Purpose: To compare postprostatectomy clinical target volume (CTV) delineation before and after the introduction of a contouring protocol and to investigate its effect on interphysician variability Methods and Materials: Six site-specialized radiation oncologists independently delineated a CTV on the computed tomography (CT) scans of 3 patients who had received postprostatectomy radiotherapy. At least 3 weeks later this was repeated, but with the physicians adhering to the contouring protocol from the Medical Research Council's Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trial. The volumes obtained before and after the protocol were compared and the effect of the protocol on interphysician variability assessed. Results: An increase in mean CTV for all patients of 40.7 to 53.9cm{sup 3} was noted as a result of observing the protocol, with individual increases in the mean CTV of 65%, 15%, and 24% for Patients 1, 2, and 3 respectively. A reduction in interphysician variability was noted when the protocol was used. Conclusions: Substantial interphysician variation in target volume delineation for postprostatectomy radiotherapy exists, which can be reduced by the use of a contouring protocol. The RADICALS contouring protocol increases the target volumes when compared with those volumes typically applied at our center. The effect of treating larger volumes on the therapeutic ratio and resultant toxicity should be carefully monitored, particularly if the same dose-response as documented in radical prostate radiotherapy applies to the adjuvant and salvage setting. Prostate cancer, Postprostatectomy, Radiotherapy, Target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Learning protocols for the fast and efficient control of active matter

Exact analytic calculation shows that optimal control protocols for passive molecular systems often involve rapid variations and discontinuities. However, similar analytic baselines are not generally available for active-matter systems, because it is more difficult to treat active systems exactly. Here we use machine learning to derive efficient control protocols for active-matter systems, and find that they are characterized by sharp features similar to those seen in passive systems. We show that it is possible to learn protocols that effect fast and efficient state-to-state transformations in simulation models of active particles by encoding the protocol in the form of a neural network. We use evolutionary methods to identify protocols that take active particles from one steady state to another, as quickly as possible or with as little energy expended as possible. Our results show that protocols identified by a flexible neural-network ansatz, which allows the optimization of multiple control parameters and the emergence of sharp features, are more efficient than protocols derived recently by constrained analytical methods. Our learning scheme is straightforward to use in experiment, suggesting a way of designing protocols for the efficient manipulation of active matter in the laboratory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories

Purpose: This study aimed to provide a comprehensive patient-specific organ dose estimation across a multiplicity of computed tomography (CT) examination protocols. Methods: A validated Monte Carlo program was employed to model a common CT system (LightSpeed VCT, GE Healthcare). The organ and effective doses were estimated from 13 commonly used body and neurological CT examination. The dose estimation was performed on 58 adult computational extended cardiac-torso phantoms (35 male, 23 female, mean age 51.5 years, mean weight 80.2 kg). The organ dose normalized by CTDI{sub vol} (h factor) and effective dose normalized by the dose length product (DLP) (k factor) were calculated from the results. A mathematical model was derived for the correlation between the h and k factors with the patient size across the protocols. Based on this mathematical model, a dose estimation iPhone operating system application was designed and developed to be used as a tool to estimate dose to the patients for a variety of routinely used CT examinations. Results: The organ dose results across all the protocols showed an exponential decrease with patient body size. The correlation was generally strong for the organs which were fully or partially located inside the scan coverage (Pearson sample correlation coefficient (r) of 0.49). The correlation was weaker for organs outside the scan coverage for which distance between the organ and the irradiation area was a stronger predictor of dose to the organ. For body protocols, the effective dose before and after normalization by DLP decreased exponentially with increasing patient's body diameter (r > 0.85). The exponential relationship between effective dose and patient's body diameter was significantly weaker for neurological protocols (r < 0.41), where the trunk length was a slightly stronger predictor of effective dose (0.15 < r < 0.46). Conclusions: While the most accurate estimation of a patient dose requires specific modeling of the patient anatomy, a first order approximation of organ and effective doses from routine CT scan protocols can be reasonably estimated using size specific factors. Estimation accuracy is generally poor for organ outside the scan range and for neurological protocols. The dose calculator designed in this study can be used to conveniently estimate and report the dose values for a patient across a multiplicity of CT scan protocols.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-01: Minimum Detectability Analysis for Comprehensive Sized Based Optimization of Image Quality and Radiation Dose Across CT Protocols

Purpose: This work involved a comprehensive modeling of task-based performance of CT across a wide range of protocols. The approach was used for optimization and consistency of dose and image quality within a large multi-vendor clinical facility. Methods: 150 adult protocols from the Duke University Medical Center were grouped into sub-protocols with similar acquisition characteristics. A size based image quality phantom (Duke Mercury Phantom) was imaged using these sub-protocols for a range of clinically relevant doses on two CT manufacturer platforms (Siemens, GE). The images were analyzed to extract task-based image quality metrics such as the Task Transfer Function (TTF), Noise Power Spectrum, and Az based on designer nodule task functions. The data were analyzed in terms of the detectability of a lesion size/contrast as a function of dose, patient size, and protocol. A graphical user interface (GUI) was developed to predict image quality and dose to achieve a minimum level of detectability. Results: Image quality trends with variations in dose, patient size, and lesion contrast/size were evaluated and calculated data behaved as predicted. The GUI proved effective to predict the Az values representing radiologist confidence for a targeted lesion, patient size, and dose. As an example, an abdomen pelvis exam for the GE scanner, with a task size/contrast of 5-mm/50-HU, and an Az of 0.9 requires a dose of 4.0, 8.9, and 16.9 mGy for patient diameters of 25, 30, and 35 cm, respectively. For a constant patient diameter of 30 cm, the minimum detected lesion size at those dose levels would be 8.4, 5, and 3.9 mm, respectively. Conclusion: The designed CT protocol optimization platform can be used to evaluate minimum detectability across dose levels and patient diameters. The method can be used to improve individual protocols as well as to improve protocol consistency across CT scanners.

60 APPLIED LIFE SCIENCES↗

Tradeoffs in implementing primary-backup protocols

One way to implement a fault-tolerant service is by using multiple servers that fail independently. The state of the service is replicated and distributed among these servers, and updates are coordinated so that even when a subset of the servers fail, the service remains available. A common approach to structuring such replicated services is to designate one server as the primary and all the others as backups. Clients make requests by sending messages only to the primary. If the primary fails, then a failover occurs and one of the backups takes over. This service architecture is commonly called the primary-backup or the primary-copy approach. In most such primary-backup protocols, when the primary receives a client request, it informs the backups about the request, and then responds to the client. Informally, this primary-backup protocol is non-blocking if the primary does not wait for an acknowledgement from the backups before it sends the response; otherwise, it is blocking. Most of the existing protocols are blocking as non-blocking protocols cannot be constructed for some kinds of failures. However, it is shown that non-blocking protocols can be constructed for most of the process and communication failures that are expected to occur in the primary-backup systems of the future. Since non-blocking protocols can theoretically achieve the smallest possible response time, this paper analyzes these protocols under various system parameters. Two kinds of non-blocking protocols are analyzed: one in which the processes use point-to-point communication to exchange messages, and the other in which processes use hardware broadcasts.

Budhiraja, Navin↗

Study and Simulation of Enhancements for TCP (Transmission Control Protocol) Performance Over Noisy, High-Latency Links

The designers of the TCP/IP protocol suite explicitly included support of satellites in their design goals. The goal of the Internet Project was to design a protocol which could be layered over different networking technologies to allow them to be concatenated into an internet. The results of this project included two protocols, IP and TCP. IP is the protocol used by all elements in the network and it defines the standard packet format for IP datagrams. TCP is the end-to-end transport protocol commonly used between end systems on the Internet to derive a reliable bi-directional byte-pipe service from the underlying unreliable IP datagram service. Satellite links are explicitly mentioned in Vint Cerf's 2-page article which appeared in 1980 in CCR [2] to introduce the specifications for IP and TCP. In the past fifteen years, TCP has been demonstrated to work over many differing networking technologies, including over paths including satellites links. So if satellite links were in the minds of the designers from the beginning, what is the problem? The problem is that the performance of TCP has in some cases been disappointing. A goal of the authors of the original specification of TCP was to specify only enough behavior to ensure interoperability. The specification left a number of important decisions, in particular how much data is to be sent when, to the implementor. This was deliberately' done. By leaving performance-related decisions to the implementor, this would allow the protocol TCP to be tuned and adapted to different networks and situations in the future without the need to revise the specification of the protocol, or break interoperability. Interoperability would continue while future implementations would be allowed flexibility to adapt to needs which could not be anticipated at the time of the original protocol design.

Shepard, Timothy J.↗

Satellite Communications Using Commercial Protocols

NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.

Ivancic, William D.↗

Operational Implementation of a 2-Hour Prebreathe Protocol for International Space Station

Procedures, equipment, and analytical techniques were developed to implement the ground tested 2-hour protocol in-flight operations. The methods are: 1) The flight protocol incorporates additional safety margin over the ground tested protocol. This includes up to 20 min of additional time on enriched O2 during suit purge and pressure check, increased duration of extravehicular activity (EVA) preparation exercise during O2 prebreathing (up to 90 min vs; the tested 24 min), and reduced rates of depressurization. The ground test observations were combined with model projections of the conservative measures (using statistical models from Duke University and NASA JSQ to bound the risk of Type I and Type II decompression sickness (DCS). 2) An inflight exercise device using the in-flight ergometer and elastic tubes for upper body exercise was developed to replicate the dual cycle exercise in the ground trials. 3) A new in-flight breathing system was developed and man-tested. 4) A process to monitor inflight experience with the protocol, including the use of an in-suit Doppler bubble monitor when available, was developed. The results are: 1) The model projections of the conservative factors of the operational protocol were shown to reduce the risk of DCS to levels consistent with the observations of no DCS to date in the shuttle program. 2) Cross over trials of the dual cycle ergometer used in ground tests and the in-flight exercise system verified that02consumption and the % division of work between upper and lower body was not significantly different at the p= 0.05 level. 3) The in-flight breathing system was demonstrated to support work rates generating 75% O2(max) in 95 percentile subjects. 4) An in-flight monitoring plan with acceptance criteria was put in place for the 2-hour prebreathe protocol. And the conclusions are: The 2-hour protocol has been approved for flight, and all implementation efforts are in place to allow use of the protocol as early as flight ISS 7A, now scheduled in November of 2000.

Waligora, James M.↗

Verification of a Byzantine-Fault-Tolerant Self-stabilizing Protocol for Clock Synchronization

This paper presents the mechanical verification of a simplified model of a rapid Byzantine-fault-tolerant self-stabilizing protocol for distributed clock synchronization systems. This protocol does not rely on any assumptions about the initial state of the system except for the presence of sufficient good nodes, thus making the weakest possible assumptions and producing the strongest results. This protocol tolerates bursts of transient failures, and deterministically converges within a time bound that is a linear function of the self-stabilization period. A simplified model of the protocol is verified using the Symbolic Model Verifier (SMV). The system under study consists of 4 nodes, where at most one of the nodes is assumed to be Byzantine faulty. The model checking effort is focused on verifying correctness of the simplified model of the protocol in the presence of a permanent Byzantine fault as well as confirmation of claims of determinism and linear convergence with respect to the self-stabilization period. Although model checking results of the simplified model of the protocol confirm the theoretical predictions, these results do not necessarily confirm that the protocol solves the general case of this problem. Modeling challenges of the protocol and the system are addressed. A number of abstractions are utilized in order to reduce the state space.

Malekpour, Mahyar R.↗

Nasa Exploration Atmosphere Tests 3 & 4: Development and Validation of Planetary Extravehicular Activity Prebreathe Protocols for Alternate Atmospheres and Suit Pressures

INTRODUCTION: Space suits operate at low pressures to optimize astronauts’ performance. The drop in pressure from the habitat environment to the suit carries a risk of decompression sickness (DCS), which is mitigated by a 95% O2 prebreathe protocol. Prebreathe protocols for the lunar surface have a significantly higher risk compared to International Space Station microgravity Extravehicular Activities (EVA). In previous studies, we validated a prebreathe protocol from a 56.5 kPa 34% O2 cabin to a 29.6 kPa EVA pressure; however, the enriched oxygen cabin environment poses a flammability risk that requires significant changes to material design and selections. Here, we report outcomes for prebreathe protocols from a sub-30% O2 cabin and associated changes necessary to control DCS risk critical to upcoming lunar missions. METHODS: Fourteen volunteers completed 11-day hypobaric chamber studies with an “alternate exploration atmosphere” of 66.2kPa, 28.5% O2. Subjects acclimated for 48 hrs and then participated in five 6-hour simulated EVAs at 29.6 or 35.6kPa, 95% O2. Prior to EVA, subjects underwent a 20, 90, or 150-minute prebreathe. The EVA simulation was designed to be representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was monitored by real-time doppler and echocardiograph alternating every 15 min, as well as clinical monitoring for DCS signs/symptoms. Venous gas emboli (VGE) and DCS outcomes were verified against NASA-STD-3001 acceptance criteria. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were identified during all EVAs. A neurological DCS case was identified in the 90-min/29.6kPa prebreathe, terminating further testing of this protocol. No DCS cases were identified in the 150 min/29.6kPa protocol. The 20 min/36.5kPa protocol was rejected due to a Type II DCS case. All DCS symptoms resolved with treatment, with no sequelae post initial treatment of DCS. These various test points highlighted to the significant benefit of elevated suit pressure to shorten prebreathe protocols, but also the difficulty in assessing and managing DCS during sustained EVA operations in remote planetary surfaces.

decompression sickness↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Its subsequent use in the field and review by the protocol working group and most importantly the users’ subgroup and the thermal subgroup has led to the fundamental modifications reflected in this update of the 2012 Protocol. As an update of the 2012 Protocol, this document (the June 2014 Protocol) is intended to supersede its predecessor and be used as the basis for measuring and expressing ESS performance. The foreword provides general and specific details about what additions, revisions, and enhancements have been made to the 2012 Protocol and the rationale for them in arriving at the June 2014 Protocol.

energy storage system↗

Elucidating the Effect of Ion Exchange Protocol on the Copper Exchange Efficacy, Copper Siting, and SCR activity in Cu-SSZ-13

The influence of the copper ion exchange protocol on SCR activity of SSZ-13 is quantified. Using the same parent SSZ-13 zeolite, four exchange protocols are used to assess how exchange protocol impacts metal uptake and SCR activity. Large differences in the SCR activity, nearly 30 percentage points at 160 °C at constant copper content, are observed for different exchange protocols implying that different exchange protocols lead to different copper species. Hydrogen temperature programmed reduction on selected samples and infrared spectroscopy of CO binding corroborates this conclusion as the reactivity at 160 °C correlates with the intensity of the IR band at 2162 cm -1 . DFT-based calculations show that such an IR assignment is consistent with CO adsorbed on a Cu(I) cation within an eight-membered ring. This work shows that SCR activity can be influenced by the ion exchange process even when different protocols lead to the same metal loading. Perhaps most interesting, a protocol used to generate Cu-MOR for methane to methanol studies led to the most active catalyst both on a unit mass or unit mole copper basis. This points to a yet not recognized means to tailor catalyst activity as the open literature is silent on this issue.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the efficiency of single and multiple teleportation protocols based on the direct use of partially entangled states

We push the limits of the direct use of partially pure entangled states to perform quantum teleportation by presenting several protocols in many different scenarios that achieve the optimal efficiency possible. We review and put in a single formalism the three major strategies known to date that allow one to use partially entangled states for direct quantum teleportation (no distillation strategies permitted) and compare their efficiencies in real world implementations. We show how one can improve the efficiency of many direct teleportation protocols by combining these techniques. We then develop new teleportation protocols employing multipartite partially entangled states. The three techniques are also used here in order to achieve the highest efficiency possible. Finally, we prove the upper bound for the optimal success rate for protocols based on partially entangled Bell states and show that some of the protocols here developed achieve such a bound. -- Highlights: •Optimal direct teleportation protocols using directly partially entangled states. •We put in a single formalism all strategies of direct teleportation. •We extend these techniques for multipartite partially entangle states. •We give upper bounds for the optimal efficiency of these protocols.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of flexible and rigid (class solution) radiation therapy conformal prostate planning protocols

Protocols commonly implemented in radiotherapy work areas may be classified as being either rigid (class solution) or flexible. Because formal evaluation of these protocol types has not occurred within the literature, we evaluated the efficiency of a rigid compared with flexible prostate planning protocol by assessing a series of completed 3D conformal prostate plans. Twenty prostate cancer patients with an average age of 70 years (range, 52-77) and sizes comprising 8 small, 10 medium, and 2 large were planned on the Phillips Pinnacle treatment planning system 6 times by radiation therapists with <2 years, 2-5 years, and >5 years of experience using a rigid and flexible protocol. Plans were critiqued using critical organ doses, confirmation numbers, and conformity index. Plans were then classified as being acceptable or not. Plans produced with the flexible protocol were 53% less likely to require modification (OR 0.47, 95% CI: 0.26, 0.84, p = 0.01). Planners with >5 years of experience were 78% more likely to produce plans requiring modification (OR 1.78, 95% CI: 1.12, 2.83, P = 0.02). Plans according to the flexible protocol took longer (112 min) compared with the time taken using a rigid protocol (68 min) (p < 0.001). The results suggest that further studies are needed; however, we propose that all radiation therapy planners should start with the same limitations, and if an acceptable plan is not reached, then flexibility should be given to improve the plan to meet the desired results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Asymptotic optimality of twist-untwist protocols for Heisenberg scaling in atom-based sensing

Twist-untwist protocols for quantum metrology consist of a serial application of (1) unitary nonlinear dynamics (e.g., spin squeezing or Kerr nonlinearity), (2) parameterized dynamics U ( φ ) (e.g., a collective rotation or phase space displacement), and (3) time reversed application of step 1. Such protocols are known to produce states that allow Heisenberg scaling for experimentally accessible estimators of φ even when the nonlinearities are applied for times much shorter than required to produce Schrödinger cat states. In this work, we prove that, asymptotically in the number of particles, twist-untwist protocols provide the lowest estimation error among quantum metrology protocols that utilize two calls to a weakly nonlinear evolution and a readout involving only first and second moments of a total spin operator n → · J → . We consider the following physical settings: all-to-all interactions generated by one-axis twisting J z 2 (e.g., interacting Bose gases), constant finite range spin-spin interactions of distinguishable or bosonic atoms (e.g., trapped ions or Rydberg atoms, or lattice bosons). In these settings, we further show that the optimal twist-untwist protocols asymptotically achieve 85% and 92% of the respective quantum Cramér-Rao bounds. We show that the error of a twist-untwist protocol can be decreased by a factor of L without an increase in the noise of the spin measurement if the twist-untwist protocol can be noiselessly iterated as an L layer quantum alternating operator ansatz.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-F-207-16: CT Protocols Optimization Using Model Observer

Purpose: To quantitatively evaluate the performance of different CT protocols using task-based measures of image quality. This work studies the task of size and the contrast estimation of different iodine concentration rods inserted in head- and body-sized phantoms using different imaging protocols. These protocols are designed to have the same dose level (CTDIvol) but using different X-ray tube voltage settings (kVp). Methods: Different concentrations of iodine objects inserted in a head size phantom and a body size phantom are imaged on a 64-slice commercial CT scanner. Scanning protocols with various tube voltages (80, 100, and 120 kVp) and current settings are selected, which output the same absorbed dose level (CTDIvol). Because the phantom design (size of the iodine objects, the air gap between the inserted objects and the phantom) is not ideal for a model observer study, the acquired CT images are used to generate simulation images with four different sizes and five different contracts iodine objects. For each type of the objects, 500 images (100 x 100 pixels) are generated for the observer study. The observer selected in this study is the channelized scanning linear observer which could be applied to estimate the size and the contrast. The figure of merit used is the correct estimation ratio. The mean and the variance are estimated by the shuffle method. Results: The results indicate that the protocols with 100 kVp tube voltage setting provides the best performance for iodine insert size and contrast estimation for both head and body phantom cases. Conclusion: This work presents a practical and robust quantitative approach using channelized scanning linear observer to study contrast and size estimation performance from different CT protocols. Different protocols at same CTDIvol setting could Result in different image quality performance. The relationship between the absorbed dose and the diagnostic image quality is not linear.

60 APPLIED LIFE SCIENCES↗

SU-F-R-06: Traumatic Brachial Plexus Injury Imaging, Developing a Coherent Clinical Protocol From Literature Review Through Practice

Purpose: Medical Physics teams can now play a critical role to help plan and provide studied approaches for traumatic brachial plexus MR imaging (tbpMRI). This is especially important for coordination with uncommon applications, since it is challenging to select the right modality, parameters, and train technologists on the essential components. For this work, we started with a review of the medical literature, performed crossover/volunteer studies to bring tbpMRI to practice with greater image QC and protocol management. Methods: To the best of our knowledge, we reviewed the known searchable domain for tbpMRI. We found 69 total articles since 2000. Articles were evaluated with our published protocol for literature management (LIMES3). Two physicists and two radiologists condensed the information from all articles into a knowledgebase. Results: The initial literature demonstrated great heterogeneity, which was a sign that this area needed greater consistency. Despite inconsistency and imprecision, we extracted the most relevant targets using our long-term experience with protocol development in MSK. We ran volunteers on six different magnets of various field strengths with multiple receiver coils, and rebuilt a coherent protocol for tbpMRI. Our radiologists rated LIMES3 work as superior. We have received referrals from the ER and have conducted four patient evaluations. Conclusion: Traumatic brachial plexus MRI has great possible benefits for patients. This work supports the complexity of tbpMRI scanning. As this is rarely performed, it requires a more diligent protocol workflow, coordination of caregivers, and education within multiple clinical departments. Choosing the correct imaging exam can be critical, as patients can have significant neuropathy and/or paralysis. The LIMES3 protocol is well liked at our institution, and forms the cornerstone of understanding for our work. Our literature management led to a better clinical protocol creation despite the diffuse and inconclusive information presented in the existing medical literature.

60 APPLIED LIFE SCIENCES↗

SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

60 APPLIED LIFE SCIENCES↗