Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTON ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Dark field proton radiography

A pre- and post-collimation scheme has been applied to high energy proton radiography to establish a dark field condition, which defaults to a state of no transmission until a scatterer is placed at the object plane. This technique, dark field proton radiography, provides two additional capabilities to a standard proton radiography setup. First, protons with a high degree of angular dispersion are removed from the beam, reducing the effects of chromatic aberrations and decreasing noise. Second, protons below the same threshold are removed from the beam downstream of the objects, effectively making the transmission highly sensitive to small amounts of scatter at the object plane. Finally, initial results indicate that the system is highly sensitive to the presence of thinner materials and improves sensitivity to subtle areal density variations in thick objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Field Proton Radiography (Los Alamos LDRD Report)

Proton radiography at LANL (pRad) takes advantage of the high flux, high proton energy, and flexible timing structure of LANSCE's 800-MeV proton beam to visualize dense, dynamic systems under extreme strain. With recent needs identified for the development of the W93, the pRad team has been actively searching for ways to increase the facility's radiographic capabilities. Recently, we discovered that utilizing two magnetic lenses (one upstream and one downstream of the object), and specific combinations of collimator choices within the two lenses, that the signal-to-noise ratio was improved by more than a factor of two. However, we did not fully understand the mechanism, and found that results did not match forward modeling predictions. This work specifically sought to implement an engineering solution to solve this problem, through the development of an actuated collimator that reduced the time required to swap collimator settings from a typical 4-8 hours, to less than 30 seconds. This allowed, in combination with a unique multi-material, multi-resolution stepwedge, to acquire an unprecedently enormous dataset, with in total 24 collimation combinations, and multiple diffuser settings and pulse patterns, equivalent to almost a full run cycle's worth of data in a few days. This massive dataset is currently being harnessed to make a fully-predictive, ultra-fast Python-based model of the system, to dial in specific settings for any future experiments that fully optimize that radiographic sensitivity to the material of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Low-energy Ionization Signals in Silicon Detectors for the Nab Experiment

The Nab (Neutron a b) experiment is designed to measure the beta-antineutrino angular correlation in free neutron 𝛽 decay with an ultimate precision goal of 0.1%, providing input for tests of Cabibbo-Kobayashi-Maskawa matrix unitarity. This measurement is performed via detection of electrons and protons in delayed coincidence using custom large-area segmented silicon detectors. We present the characterization of one such detector system to establish the proton energy and timing response, using a dedicated proton accelerator. The detected proton peak was studied for 25, 30, and 35 keV incident protons on a set of detector segments and multiple cooling cycles over a one-year period. Ionization losses were consistent with models of the detector dead layer with thicknesses less than 100 nm. The detected proton peak was stable within the uncertainty from energy calibration (0.25 keV). The rise times of detector pulses from 109Cd and 113Sn conversion electron sources were used to extract the impurity density profile and establish a precise model for the detector timing response. The observed impurity density profile varied from (2±2)×109/cm3 at the center to (26±2)×109/cm3 at the edge. This impurity density profile was then used to characterize systematic effects in proton time-of-flight measurements due to detector pulse-shape effects; the resultant proton timing systematic uncertainties were below 0.3 ns, which is sufficient for the Nab experiment.

Taylor, RJ [North Carolina State University]↗

Initial Assessment of Availability and Reliability for the PIP-II Superconducting Radio Frequency Linear Accelerator Facility

The Proton Improvement Plan -II (PIP-II) is a high intensity and high energy proton accelerator which will be used to support the neutrino program at Fermilab. The accelerator will deliver a 2 mA average beam current at a kinetic energy of 800 MeV. Due to the requirements from experiments, this accelerator is designed to be a highly reliable and available system. A target availability of the complete accelerator facility was prescribed to be 90%. An availability and reliability assessment of the accelerator was carried out to ascertain that the design can meet the target availability specification. The results were estimated for the nominal operational mode, when an 800 MeV beam is delivered on the target and for the critical operational mode, when a 600 MeV output beam was incident on the target. The design of a complete accel-erator system is a complex arrangement of a large number of components. To simplify the analysis, a few components were shortlisted and based on their functions, an accelerator model was created. The model is represented in the form of reliability block diagrams. Availability and reliability were estimated for each operational mode. To increase the availa-bility and reliability of the overall accelerator, redundancy of one cavity per section in the superconducting portion of the Linac was introduced.

43 PARTICLE ACCELERATORS↗

Protonic ceramic materials for clean and sustainable energy: advantages and challenges

In recent years, the hydrogen economy has been strongly favoured by governmental and industrial bodies worldwide. A tremendous number of papers are published every year on different aspects of protonic ceramic electrochemical cells (PCECs) due to their lower operation temperature, easier reversible operation, and brighter prospects for further development. While new progress is being made continuously, many critical challenges remain. The effort on PCEC investigation could be more aligned for greater collective impact, e.g. the academic community could devote more effort to overdue critical problems but less to incremental improvements. This review aims to provide some insightful perspectives on critical challenges facing the development of PCECs, to sort out priorities in future effort, and to suggest promising directions to pursue. In this way, it is hoped that the technical readiness level of PCECs might advance more quickly, toward field demonstrations and commercialization for a clean and sustainable energy era.

36 MATERIALS SCIENCE↗

Reorganization Energies for Interfacial Proton-Coupled Electron Transfer to a Water Oxidation Catalyst

The reorganization energy (λ) for interfacial electron transfer (ET) and proton-coupled electron transfer (PCET) from a conductive metal oxide (In 2 O 3 :Sn, ITO) to a surface-bound water oxidation catalyst were extracted from kinetic data measured as a function of the thermodynamic driving force. Visible light excitation resulted in rapid excited-state injection (k inj > 10 8 s -1 ) to the ITO, which photo-initiated the two interfacial reactions of interest. The rate constants for both reactions increased with the driving force, −ΔG°, to a saturating limit, k max , with rate constants consistently larger for ET than for PCET. Marcus-Gerischer analysis of the kinetic data provided the reorganization energy for interfacial PCET (0.90 ± 0.02 eV) and ET (0.40 ± 0.02 eV), respectively. The magnitude of k max for PCET was found to decrease with pH, behavior that was absent for ET. Both the decrease in k max and the larger reorganization energy for an unwanted competing PCET reaction from the ITO to the oxidized catalyst showcases a significant kinetic advantage for driving solar water oxidation at high pH. Computational analysis revealed a larger inner-sphere reorganization energy contribution for PCET than for ET arising from a more significant change in the Ru–O bond length for PCET. Extending Marcus-Gerischer theory to PCET by including the excited electron-proton vibronic states and the proton donor-acceptor motion provided an apparent reorganization energy of 1.01 eV. Furthermore, this study demonstrates that the Marcus-Gerischer theory initially developed for ET can be reliably extended to PCET for quantifying and interpreting reorganization energies observed experimentally.

Catalysts Kinetic parameters↗

Characterizing hole trap production due to proton irradiation in germanium cross-strip detectors

We present an investigation into the effects of high-energy proton damage on charge trapping in germanium cross-strip detectors with the goal of accomplishing three important measurements. First, we calibrated and characterized the spectral resolution of a spare COSI-balloon detector in order to determine the effects of intrinsic trapping, finding that electron trapping due to impurities dominates over hole trapping in the undamaged detector. Second, we performed two rounds of proton irradiation of the detector in order to quantify, for the first time, the rate at which charge traps are produced by proton irradiation. We find that the product of the hole trap density and cross-sectional area, [nσ] h , follows a linear relationship with the proton fluence, F p , with a slope of (5.4 ± 0.4) x 10 -11 cm/p + . Third, by utilizing our measurements of physical trapping parameters, we performed calibrations which corrected for the effects of trapping and mitigated degradation to the spectral resolution of the detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstrating imaging plate detector stacks for proton radiography using exploding pusher capsules

A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Illustration of bunch merge simulation in RHIC

Following are examples of a 4 to 2 to 1 merge of proton bunches in RHIC obtained by running the simulation code rhic2mrg23. As the code runs, the user is prompted to enter several numbers. For these examples, RF harmonic number 1440.0 is entered. An RF frequency of 112.597 696 626 MHz at this harmonic is entered. This gives a proton energy of 100 GeV. The merge simulation starts with a uniform distribution of unbunched protons. 2.0 eV-s is entered for the longitudinal emittance of the distribution. The code will recommend a voltage to capture the unbunched protons into 4 harmonic 1440 buckets. A capture voltage of 142.390 kV is recommended. 144.0 kV is entered. It is desirable to capture the protons as “adiabatically” as possible. A capture time of 3318 ms is recommended by the code. 3320.0 ms is entered. A 4 to 2 merge time of 1659 ms is recommended by the code. 1660.0 ms is entered. A 2 to 1 merge time twice that of the 4 to 2 merge is recommended by the code. 3320.0 ms is entered. The code requests a “time fraction” FQMRG to be entered. This is a number (from 0.1 to 1.0) that determines the time at which data are recorded during the 4 to 2 merge. The number 0.5 is entered. This encodes the recording of data halfway through the 4 to 2 merge.

43 PARTICLE ACCELERATORS↗

Influence of electrical field on the susceptibility of gallium nitride transistors to proton irradiation

Radiation susceptibility of electronic devices is commonly studied as a function of radiation energetics and device physics. Often overlooked is the presence or magnitude of the electrical field, which we hypothesize to play an influential role in low energy radiation. Accordingly, we present a comprehensive study of low-energy proton irradiation on gallium nitride high electron mobility transistors (HEMTs), turning the transistor ON or OFF during irradiation. Commercially available GaN HEMTs were exposed to 300 keV proton irradiation at fluences varying from 3.76 × 10 12 to 3.76 × 10 14 cm 2 , and the electrical performance was evaluated in terms of forward saturation current, transconductance, and threshold voltage. The results demonstrate that the presence of an electrical field makes it more susceptible to proton irradiation. The decrease of 12.4% in forward saturation and 19% in transconductance at the lowest fluence in ON mode suggests that both carrier density and mobility are reduced after irradiation. Additionally, a positive shift in threshold voltage (0.32 V and 0.09 V in ON and OFF mode, respectively) indicates the generation of acceptor-like traps due to proton bombardment. high-resolution transmission electron microscopy and energy dispersive x-ray spectroscopy analysis reveal significant defects introduction and atom intermixing near AlGaN/GaN interfaces and within the GaN layer after the highest irradiation dose employed in this study. According to in-situ Raman spectroscopy, defects caused by irradiation can lead to a rise in self-heating and a considerable increase in (∼750 times) thermoelastic stress in the GaN layer during device operation. The findings indicate device engineering or electrical biasing protocol must be employed to compensate for radiation-induced defects formed during proton irradiation to improve device durability and reliability.

gallium nitride↗

Proton Radiation Tolerance of Wide and Narrow Band Gap Perovskite Solar Cells

Two different single junction mixed organic-inorganic halide perovskite solar cells (PSCs) were assessed for their tolerance to high energy proton radiation. Both the narrow band gap mixed tin-lead iodide and wide band gap lead iodide-bromide show remarkable tolerance for fluences up to 1x10 11 p/cm 2 . Both materials show a retention of open circuit voltage and decrease in dark current densities indicating minimal effect on SRH recombination that typically plagues traditional III-V based solar cells. Additionally, a control device that was processed without the perovskite absorber layer showed better diode characteristics and lower dark current densities after proton irradiation. The tolerance of these perovskite as a class of materials is promising for multijunction tandem flexible photovoltaic devices.

perovskite↗

A Broadband Mechanically Tuned Superconducting Cavity Design Suitable for the Fermilab Main Injector

Radio Frequency superconductivity has been a mainstay of accelerator science for decades. However, its benefits have yet to be applied to proton synchrotrons with demanding tuning requirements. For example, the Main Injector (MI), Fermilab's high-energy proton synchrotron, currently utilizes 20+ ferrite-loaded cavities for a targeted 1.2 s acceleration cycle. Harnessing the extremely high gradients associated with superconductivity, the required number of cavities could be reduced by an order of magnitude, dramatically lowering operational power requirements even with cryogenic considerations. Additionally, the current plans for the Fermilab accelerator complex evolution initiative involve almost doubling the number of cavities in MI if the same designs are to be used, further highlighting the potential benefits of superconductivity. These advantages are attractive, but to date, no tunable superconducting cavity suitable for MI has been proposed due to the incompatibility of conventional broadband tuning methods with superconductivity. Here, we present a tunable superconducting cavity concept capable of record-breaking performance. Tuning will be accomplished by using high-speed linear actuators to vary the insertion depth of metallic plungers into the cavity volume. This tuning concept is theoretically viable with currently available technology and will be fully compatible with a superconducting cavity.

43 PARTICLE ACCELERATORS↗

A Mechanically Tuned Superconducting Main Injector Cavity

Radio Frequency (RF) superconductivity has been a mainstay of accelerator science for decades. However, its benefits have yet to be applied to proton synchrotrons with demanding tuning requirements. For example, the Main Injector (MI), Fermilab's high-energy proton synchrotron, currently utilizes 20+ ferrite-loaded cavities for a targeted 1.2 s acceleration cycle. Harnessing the extremely high gradients associated with superconductivity, the required number of cavities could be reduced by an order of magnitude, dramatically lowering operational power requirements even with cryogenic considerations. Additionally, the current plans for the Fermilab Accelerator Complex Evolution (ACE) initiative involve almost doubling the number of cavities in MI if the same designs are to be used, further highlighting the potential benefits of superconductivity. These advantages are attractive, but to date, no tunable superconducting cavity suitable for MI has been proposed due to the incompatibility of conventional broadband tuning methods with superconductivity. Here, we present a tunable superconducting cavity concept capable of record-breaking performance. Tuning will be accomplished by using high-speed linear actuators to vary the insertion depth of metallic plungers into the cavity volume. This tuning concept is theoretically viable with currently available technology and will be fully compatible with a superconducting cavity.

43 PARTICLE ACCELERATORS↗

Study of a Fixed Field Accelerator as a Driver for Proton Driven Plasma Wakefield Acceleration

A fixed field accelerator (FFA) scheme is studied that is aimed to provide a continuous stream of high-energy proton bunches at a rate of up to 20 kHz. The bunches can be used to drive plasma wakefields capable of acceleration of leptons in a single stage for a lepton collider at the Higgs and the top-mass scales. The proposed FFA is assumed to have a circumference of 6900 m and is designed to accelerate proton bunches from 150 GeV to 500 GeV .

43 PARTICLE ACCELERATORS↗

High Quality Doping of GaN Through Transmutation Processing

This project led to several outstanding achievements: - Computational modeling of nuclear reactions, including estimates of the production ratio and doping concentration using TALYS 1.96 based on nuclear reactions in GaN induced by gamma-ray and protons. For photonuclear transmutation doping, simulations proved that Zn/Ge ratio with 40 MeV is higher than the other energies. - Proton transmutation doping was shown to be a potential nuclear source to fabricate p-type gallium-based semiconductor materials, examined during new irradiations with Oak Ridge National Laboratory and Brookhaven National Laboratory (in 200 MeV H - –Linac). - Patent disclosure to the University of Missouri-Columbia about healing effects in GaN by radiations. - Zn-doped p-type GaN through photonuclear transmutation doping process. - The PIs made an oral presentation on the p-type characteristics of Zn-doped GaN at the Materials Research Society Fall meeting in Boston. - The last irradiation process was in progress in collaboration with Argonne National Laboratory.

36 MATERIALS SCIENCE↗

The Role of Magnetic Reconnection in Energizing Protons and Heavier Ions at the Heliospheric Current Sheet

During near-Sun crossings of the heliospheric current sheet (HCS), Parker Solar Probe (PSP) observed populations of high-energy protons and heavier ions, indicating possible energization by magnetic reconnection up to 10 s–100 s keV nucleon −1 . Here we study ion acceleration by magnetic reconnection at the HCS. To estimate ion energization, we solve the Parker transport equation coupled to a large-scale 2D MHD reconnection simulation. We find that multiple ion species develop power-law distributions with both spectral index and high-energy cutoff E max consistent with in situ data. By accounting for the injection physics determined by kinetic simulations, we confirm that the charge-to-mass ratio scales as E max ∝ (Q/M) α with α ∼ 0.8–1.1, approximately consistent with PSP measurements in the broader range α ∼ 0.6–1.7. In the limit where ions are injected at the same energy per nucleon, α can be as low as ∼0.3. These findings further support the role of magnetic reconnection in producing high-energy heavy ions at the HCS.

Murtas, Giulia [West Virginia Univ., Morgantown, W↗

Absorptive corrections to the electromagnetic form factor in high-energy elastic proton-proton scattering

Recently, it was noted that absorptive corrections to the electromagnetic form factor in high-energy proton-proton scattering are important for the theoretical interpretation of the p ↑ p and p ↑ A analyzing power A N ( t ) measurements with the Hydrogen Jet Target polarimeter (HJET) at RHIC. Here, a concise expression for the absorptive correction was derived within the eikonal approach. The resulting analysis reveals a systematic bias, nearly independent of the beam energy, in the experimental determination of the real-to-imaginary ratio ρ when absorption effects are overlooked in the data analysis. Quantification of this bias, as ρ meas = ρ + ( 0.036 ± 0.016 ) bias , was achieved using a Regge fit applied to available proton-proton measurements of ρ meas ( s ) and σ tot meas ( s ) . Considering the potential impact of such an effect on the experimentally determined A N ( t ) , one may enhance consistency between the HJET and STAR measurements of the hadronic spin-flip amplitude. While the sign of the bias in the value of ρ aligns with the anticipated effective increase in the proton charge radius in p p scattering due to absorption, it amplifies the observed discrepancy between σ tot meas and ρ meas values at s = 13 TeV as measured in the TOTEM experiment. Evaluation (using published TOTEM data) of the measured proton-proton d σ / d t dependence on the absorptive corrections indicated that possible soft photon corrections to the hadronic amplitude slope may be essential for such data analysis. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗