Search NASA⌕ Search

SEARCH · Search NASA

Results for “PSD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-C-304-03: Experimental Investigation On the Accuracy of Plastic Scintillation Dosimeters in Small Fields

Purpose: To investigate the accuracy of the Exradin W1 (SI) and of an “in-house” plastic scintillation dosimeter (CHUQ PSD) in small radiation fields. Methods: Output factor (OF) measurements with the W1 and CHUQ PSD were performed for field sizes of 0.5 x 0.5, 1 x 1 and 2 x 2 cm{sup 2}. Both detectors were placed parallel to the central axis (CAX) in water. The spectrum discrimination calibration method was performed in each set-up to account for the Cerenkov (CRV) signal created in the fiber. The OFs were compared to the expected field factors in water derived using i) Monte Carlo (MC) simulations of an accurate accelerator model and ii) microLion (PTW) and D1V diode (SI) OFs. MC-derived correction factors were applied to both the microLion and D1V OFs. For the CHUQ PSD the calibration was repeated in water (// CAX), solid water (perpendicular to CAX) and under a shielded configuration. The signal was collected using a spectrometer (wavelength range = 185–1100 nm). Spectral analysis was performed to evaluate potential changes of the spectral distributions under the various calibration set-up configurations. Results: The W1 OFs presented an over-response for the 0.5 x 0.5 cm{sup 2} in the range of 3 – 4.1% relative to the expected field factor. The CHUQ PSD presented an under-response in the range of 1.5 – 2.7%, without accounting for volume averaging. The CRV spectra under the various calibration procedures appeared similar to each other and only minor changes were observed to the respective OFs. Conclusion: The W1 and CHUQ PSD can be used in small fields down to a 1 x 1 cm{sup 2} field size. Discrepancies were encountered between the two detectors for the smallest field size of 0.5 x 0.5 cm{sup 2} with the CHUQ PSD exhibiting a closer agreement to the expected field factor. Funding sources: 1) Alexander S. Onassis Public Benefit Foundation in Greece and 2) CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council, Grant number: 432290, RGPIN-2014-06475.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

60 APPLIED LIFE SCIENCES↗

Final scientific report for DOE award title: Improving the Representation of Ice Sedimentation Rates in Global Climate Models

It is well known that cirrus clouds play a major role in regulating the earth’s climate, but the details of how this works are just beginning to be understood. This project targeted the main property of cirrus clouds that influence climate processes; the ice fall speed. That is, this project improves the representation of the mass-weighted ice particle fall velocity, V m , in climate models, used to predict future climate on global and regional scales. Prior to 2007, the dominant sizes of ice particles in cirrus clouds were poorly understood, making it virtually impossible to predict how cirrus clouds interact with sunlight and thermal radiation. Due to several studies investigating the performance of optical probes used to measure the ice particle size distribution (PSD), as well as the remote sensing results from our last ARM project, it is now well established that the anomalously high concentrations of small ice crystals often reported prior to 2007 were measurement artifacts. Advances in the design and data processing of optical probes have greatly reduced these ice artifacts that resulted from the shattering of ice particles on the probe tips and/or inlet tube, and PSD measurements from one of these improved probes (the 2-dimensional Stereo or 2D-S probe) are utilized in this project to parameterize V m for climate models. Our original plan in the proposal was to parameterize the ice PSD (in terms of temperature and ice water content) and ice particle mass and projected area (in terms of mass- and area-dimensional power laws or m-D/A-D expressions) since these are the microphysical properties that determine V m , and then proceed to calculate V m from these parameterized properties. But the 2D-S probe directly measures ice particle projected area and indirectly estimates ice particle mass for each size bin. It soon became apparent that the original plan would introduce more uncertainty in the V m calculations than simply using the 2D-S measurements to directly calculate V m . By calculating V m directly from the measured PSD, ice particle projected area and estimated mass, more accurate estimates of V m are obtained. These V m values were then parameterized for climate models by relating them to (1) sampling temperature and ice water content (IWC) and (2) the effective diameter (D e ) of the ice PSD. Parameterization (1) is appropriate for climate models having single-moment microphysical schemes whereas (2) is appropriate for double-moment microphysical schemes and yields more accurate V m estimates. These parameterizations were developed for tropical cirrus clouds, Arctic cirrus, mid-latitude synoptic cirrus and mid-latitude anvil cirrus clouds based on field campaigns in these regions. An important but unexpected result of this research was the discovery of microphysical evidence indicating the mechanisms by which ice crystals are produced in cirrus clouds. This evidence, derived from PSD measurements, indicates that homogeneous freezing ice nucleation dominates in mid-latitude synoptic cirrus clouds, whereas heterogeneous ice nucleation processes dominate in mid-latitude anvil cirrus. Based on these findings, D e was parameterized in terms of temperature (T) for conditions dominated by (1) homo- and (2) heterogeneous ice nucleation. From this, an experiment was designed for global climate models (GCMs). The net radiative forcing from cirrus clouds may be affected by the means ice is produced (homo- or heterogeneously), and this net forcing contributes to climate sensitivity (i.e. the change in mean global surface temperature resulting from a doubling of CO 2 ). The objective of this GCM experiment was to determine how a change in ice nucleation mode affects the predicted global radiation balance. In the first simulation (Run 1), the D e -T relationship for homogeneous nucleation is used at all latitudes, while in the second simulation (Run 2), the D e -T relationship for heterogeneous nucleation is used at all latitudes. For both runs, V m is calculated from D e . Two GCMs were used; the Community Atmosphere Model version 5 (CAM5) and a European GCM known as ECHAM5 (thanks to our European colleagues who collaborated with us). Similar results were obtained from both GCMs in the Northern Hemisphere mid-latitudes, with a net cooling of ~ 1.0 W m -2 due to heterogeneous nucleation, relative to Run 1. The mean global net cooling was 2.4 W m -2 for the ECHAM5 GCM while CAM5 produced a mean global net cooling of about 0.8 W m -2 . This dependence of the radiation balance on nucleation mode is substantial when one considers the direct radiative forcing from a CO 2 doubling is 4 W m -2 . The differences between GCMs in mean global net cooling estimates may demonstrate a need for improving the representation of cirrus clouds in GCMs, including the coupling between microphysical and radiative properties. Unfortunately, after completing this GCM experiment, we learned from the company that provided the 2D-S microphysical data that the data was corrupted due to a computer program coding problem. Therefore the microphysical data had to be reprocessed and reanalyzed, and the GCM experiments were redone under our current ASR project but using an improved experimental design.

54 ENVIRONMENTAL SCIENCES↗

Parameterizing Size Distribution in Ice Clouds

PARAMETERIZING SIZE DISTRIBUTIONS IN ICE CLOUDS David L. Mitchell and Daniel H. DeSlover ABSTRACT An outstanding problem that contributes considerable uncertainty to Global Climate Model (GCM) predictions of future climate is the characterization of ice particle sizes in cirrus clouds. Recent parameterizations of ice cloud effective diameter differ by a factor of three, which, for overcast conditions, often translate to changes in outgoing longwave radiation (OLR) of 55 W m-2 or more. Much of this uncertainty in cirrus particle sizes is related to the problem of ice particle shattering during in situ sampling of the ice particle size distribution (PSD). Ice particles often shatter into many smaller ice fragments upon collision with the rim of the probe inlet tube. These small ice artifacts are counted as real ice crystals, resulting in anomalously high concentrations of small ice crystals (D < 100 µm) and underestimates of the mean and effective size of the PSD. Half of the cirrus cloud optical depth calculated from these in situ measurements can be due to this shattering phenomenon. Another challenge is the determination of ice and liquid water amounts in mixed phase clouds. Mixed phase clouds in the Arctic contain mostly liquid water, and the presence of ice is important for determining their lifecycle. Colder high clouds between -20 and -36 oC may also be mixed phase but in this case their condensate is mostly ice with low levels of liquid water. Rather than affecting their lifecycle, the presence of liquid dramatically affects the cloud optical properties, which affects cloud-climate feedback processes in GCMs. This project has made advancements in solving both of these problems. Regarding the first problem, PSD in ice clouds are uncertain due to the inability to reliably measure the concentrations of the smallest crystals (D < 100 µm), known as the “small mode”. Rather than using in situ probe measurements aboard aircraft, we employed a treatment of ice cloud optical properties formulated in terms of PSD parameters in combination with remote measurements of thermal radiances to characterize the small mode. This is possible since the absorption efficiency (Qabs) of small mode crystals is larger at 12 µm wavelength relative to 11 µm wavelength due to the process of wave resonance or photon tunneling more active at 12 µm. This makes the 12/11 µm absorption optical depth ratio (or equivalently the 12/11 µm Qabs ratio) a means for detecting the relative concentration of small ice particles in cirrus. Using this principle, this project tested and developed PSD schemes that can help characterize cirrus clouds at each of the three ARM sites: SGP, NSA and TWP. This was the main effort of this project. These PSD schemes and ice sedimentation velocities predicted from them have been used to test the new cirrus microphysics parameterization in the GCM known as the Community Climate Systems Model (CCSM) as part of an ongoing collaboration with NCAR. Regarding the second problem, we developed and did preliminary testing on a passive thermal method for retrieving the total water path (TWP) of Arctic mixed phase clouds where TWPs are often in the range of 20 to 130 g m-2 (difficult for microwave radiometers to accurately measure). We also developed a new radar method for retrieving the cloud ice water content (IWC), which can be vertically integrated to yield the ice water path (IWP). These techniques were combined to determine the IWP and liquid water path (LWP) in Arctic clouds, and hence the fraction of ice and liquid water. We have tested this approach using a case study from the ARM field campaign called M-PACE (Mixed-Phase Arctic Cloud Experiment). This research led to a new satellite remote sensing method that appears promising for detecting low levels of liquid water in high clouds typically between -20 and -36 oC. We hope to develop this method in future research.

54 ENVIRONMENTAL SCIENCES↗

In-Flight Vibration Environment of the NASA F-15B Flight Test Fixture

Flight vibration data are analyzed for the NASA F-15B/Flight Test Fixture II test bed. Understanding the in-flight vibration environment benefits design and integration of experiments on the test bed. The power spectral density (PSD) of accelerometer flight data is analyzed to quantify the in-flight vibration environment from a frequency of 15 Hz to 1325 Hz. These accelerometer data are analyzed for typical flight conditions and maneuvers. The vibration data are compared to flight-qualification random vibration test standards. The PSD levels in the lateral axis generally are greater than in the longitudinal and vertical axes and decrease with increasing frequency. At frequencies less than approximately 40 Hz, the highest PSD levels occur during takeoff and landing. Peaks in the PSD data for the test fixture occur at approximately 65, 85, 105-110, 200, 500, and 1000 Hz. The pitch-pulse and 2-g turn maneuvers produce PSD peaks at 115 Hz. For cruise conditions, the PSD level of the 85-Hz peak is greatest for transonic flight at Mach 0.9. From 400 Hz to 1325 Hz, the takeoff phase has the highest random vibration levels. The flight-measured vibration levels generally are substantially lower than the random vibration test curve.

Corda, Stephen↗

Electron- and Photon-stimulated Desorption of Alkali Atoms from Lunar Sample and a Model Mineral Surface

We report recent results on an investigation of source mechanisms for the origin of alkali atoms in the tenuous planetary atmospheres, with focus on non-thermal processes (photon stimulated desorption (PSD), electron stimulated desorption (ESD), and ion sputtering). Whereas alkaline earth oxides (MgO, CaO) are far more abundant in lunar samples than alkali oxides (Na2O, K2O), the atmosphere of the Moon contains easily measurable concentrations of Na and K, while Ca and Mg are undetected there; traces of Ca have recently been seen in the Moon's atmosphere (10-3 of Na). The experiments have included ESD, PSD and ion sputtering of alkali atoms from model mineral surface (amorphous SiO2) and from a lunar basalt sample obtained from NASA. The comparison is made between ESD and PSD efficiency of monovalent alkalis (Na, K) and divalent alkaline earths (Ba, Ca).The ultrahigh vacuum measurement scheme for ESD and PSD of Na atoms includes a highly sensitive alkali metal detector based on surface ionization, and a time-of-flight technique. For PSD measurements, a mercury arc light source (filtered and chopped) is used. We find that bombardment of the alkali covered surfaces by ultraviolet photons or by low energy electrons (E>4 eV) causes desorption of hot alkali atoms. This results are consistent with the model developed to explain our previous measurements of sodium desorption from a silica surface and from water ice: electron- or photon-induced charge transfer from the substrate to the ionic adsorbate causes formation of a neutral alkali atom in a repulsive configuration, from which desorption occurs. The two-electron charge transfer to cause desorption of divalent alkaline eath ions is a less likely process.The data support the suggestion that PSD by UV solar photons is a dominant source process for alkalis in the tenuous lunar atmosphere.

Yakshinskiy, B. V.↗

Insights Into the Size-Resolved Dust Emission From Field Measurements in the Moroccan Sahara

The particle size distribution (PSD) of mineral dust has a strong effect on the impacts of dust on climate. However, our understanding of the emitted dust PSD, including its variability and the fraction of super-coarse dust (diameter >10 µm), remains limited. Here, we provide new insights into the size-resolved dust emission process based on a field campaign performed in the Moroccan Sahara in September 2019 in the context of the FRontiers in dust minerAloGical coMposition and its Effects upoN climaTe (FRAGMENT) project. The obtained dust concentration and diffusive flux PSDs show significant dependencies upon the friction velocity (u*), wind direction and type of event (regular events versus haboob events). For instance, the number fraction of sub-micrometre particles increases with u*, along with a large decrease in the mass fraction of super-coarse dust. We identify dry deposition, which is modulated by u* and fetch length, as a potential cause for this PSD variability. Using a resistance model constrained with field observations to estimate the dry deposition flux and thereby also the emitted dust flux, we show that deposition could represent up to ∼90 % of the emission of super-coarse particles (>10 µm) and up to ∼65 % of the emission of particles as small as ∼5 µm in diameter. Importantly, removing the deposition component significantly reduces the variability with u* in the PSD of the emitted dust flux compared with the diffusive flux, particularly for super-coarse dust. The differences between regular and haboob event concentration and diffusive flux PSDs are suspected to result from a smaller and variable dust source fetch during the haboob events, and/or an increased resistance of soil aggregates to fragmentation associated with the observed increase in relative humidity along the haboob outflow. Finally, compared to the invariant emitted dust flux PSD estimated based on brittle fragmentation theory, we obtain a substantially higher proportion of super-micrometre particles in the dust flux. Overall, our results suggest that dry deposition needs to be adequately considered to estimate the emitted PSD, even in studies limited to the fine and coarse size ranges (<10 µm).

particle size distribution↗

Performance stability of plastics for neutron-gamma pulse shape discrimination

The introduction of the first commercially available plastic scintillators with pulse shape discrimination (PSD) offered by Eljen Technology marked progress towards potentially replacing liquid scintillators in neutron detection. However, use of these plastics over several recent years has revealed an important flaw in these materials: the eventual degradation of scintillation light output and PSD performance. Here, studies described in this paper considered possible reasons for this degradation. Experiments conducted with numerous lab-prepared and commercial EJ-276 samples showed that the main factor affecting the instability is oxidation that involves highly reactive radicals generated during the polymerization process or from the further breakdown of polymer chains under oxygen/air exposure. Based on the obtained results, the stability of scintillation performance for PPO (2,5-Diphenyloxazole)-based PSD plastics has been improved through modifications of the composition via the utilization of scintillation dyes and compounds with antioxidant properties that diminish the effects of oxidation. Elements of these studies were used in the commercial production of the most recent EJ-276D PSD plastic version for fast neutron detection and 6Li-loaded plastics for thermal neutron and antineutrino detection applications. Performance projections of the new PSD plastics indicate a likely degradation of less than 10 % over 5–10 years in comparison to previous EJ-276 that might lose up to 30–40 % of the scintillation light during 1–2 years of storage or deployment under ambient conditions.

36 MATERIALS SCIENCE↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DOE Residential Energy Code Field Study - Pennsylvania

This project consisted of three distinct phases – all focused on residential one- and two-family dwellings and townhouses. Phase 1 included a baseline field study with inspections and performance testing to assess construction practices with respect to the energy code. PNNL used the data to perform EUI and savings potential analyses. Phase 2 consisted of training, education, and outreach to building industry professionals with content based on the findings from Phase 1. Phase 3 was a post-program field study using the same methodology as Phase 1 and was intended to measure the impact of Phase 2. During Phase 1 of the project, PSD collected data from 171 job sites across eastern Pennsylvania, a territory bounded by PECO, PPL, and Met-Ed electric distribution territories, to reach the required 63 “home equivalents” deemed necessary by PNNL for a representative sample. Based on subsequent analysis, four key items were identified as having significant savings potential from improvement in compliance, including duct leakage, above-grade wall insulation (specifically insulation installation quality), foundation insulation, and high-efficacy lighting. About half the total savings potential is from duct leakage, so that was the primary focus. The goal of Phase 2 was to improve upon these key compliance weaknesses through an intensive training, education, and outreach program. PSD dubbed this effort the Penn Energy Codes Program. For Phase 3, PSD obtained a new sample plan from PNNL, obtained permit data from sample municipalities, and made substitutions where necessary. PSD field staff visited 165 job sites to collect the required 504 key observations. PSD submitted all data collection sheets to PNNL for their analysis to determine if there was a measurable change due to Phase 2 activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prognostic value of left ventricular dyssynchrony evaluated by gated myocardial perfusion imaging in patients with chronic kidney disease and normal perfusion defect scores

Background: This study aimed to investigate whether indices of left ventricular (LV) dyssynchrony by gated myocardial perfusion SPECT (GMPS) could be useful to predict prognosis in chronic kidney disease (CKD) patients with normal perfusion defect scores. Methods: One hundred and sixty-seven CKD patients with normal perfusion defect scores on adenosine-stress {sup 201}Tl GMPS and no previous history of overt heart diseases were enrolled. Phase standard deviation (PSD) and bandwidth (BW) were automatically calculated from GMPS. The major adverse cardiac events (MACEs) for a mean of 560 days were defined as sudden cardiac death, fatal arrhythmias, and acute coronary syndrome requiring urgent coronary revascularization. Patients were divided into two groups according to the presence or absence of MACEs. Results: The MACEs occurred in 12 patients (7.1%). Patients who experienced MACEs showed significantly higher PSD and wider BW than those who did not. In the Kaplan-Meier event-free survival analysis, cardiac event rate was significantly higher in the high-PSD and wide-BW group (n = 81) than in the low-PSD and narrow-BW group (n = 71) (P = .002). The multivariate regression analysis revealed that the PSD was associated with MACEs (odds ratio 1.33, 95% confidence interval 1.05-1.69, P = .01). Conclusion: The LV dyssynchrony indices from GMPS may be novel prognostic predictors in CKD patients with normal perfusion defect scores.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NMDA-induced accumulation of Shank at the postsynaptic density is mediated by CaMKII

Highlights: • NMDA-induces accumulation of Shank at the postsynaptic density. • Shank accumulation is preferential to the distal region of the postsynaptic density. • Shank accumulation is mediated by CaMKII. - Abstract: Shank is a specialized scaffold protein present in high abundance at the postsynaptic density (PSD). Using pre-embedding immunogold electron microscopy on cultured hippocampal neurons, we had previously demonstrated further accumulation of Shank at the PSD under excitatory conditions. Here, using the same experimental protocol, we demonstrate that a cell permeable CaMKII inhibitor, tatCN21, blocks NMDA-induced accumulation of Shank at the PSD. Furthermore we show that NMDA application changes the distribution pattern of Shank at the PSD, promoting a 7–10 nm shift in the median distance of Shank labels away from the postsynaptic membrane. Inhibition of CaMKII with tatCN21 also blocks this shift in the distribution of Shank. Altogether these results imply that upon activation of NMDA receptors, CaMKII mediates accumulation of Shank, preferentially at the distal regions of the PSD complex extending toward the cytoplasm.

60 APPLIED LIFE SCIENCES↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

A moment-based kinetic theory model for polydisperse gas–particle flows

Starting from a generalized population balance equation and the Boltzmann–Enskog collision model for hard spheres, a kinetic theory model for polydisperse gas–particle flows is introduced. Here, polydispersity results from spherical particles with the same material density but different diameters. The particle size distribution (PSD) of the particles is allowed to evolve in space and time due to physical processes such as mixing. In order to treat a continuous PSD, the particle-phase model is formulated in terms of the moments of the PSD, and velocity moments conditioned on the particle size. Velocity moments up to second order are included, resulting in transport equations for the mass, momentum and granular temperature, all conditioned on the particle size. In the numerical implementation, the PSD is represented using quadrature-based moment methods (QBMM). With QBMM, a continuous PSD can be treated using a relatively small number of moments as compared to class or sectional methods. In this work, a realizable numerical algorithm for solving the moment system in a finite-volume code is proposed, valid for dilute systems wherein frictional forces are negligible. The ability of the proposed model to describe polydisperse gas–particle systems is demonstrated using cluster-induced turbulence and riser flow.

42 ENGINEERING↗

Outer Radiation Belt Dynamics During the October 2012 Storm Revisited: Rapid Inward Radial Transport From a Dynamic Outer Boundary

Earth's outer radiation belt electron flux is highly variable and can be enhanced by over an order of magnitude over timescales less than one day, as observed during the October 2012 storm. Previous studies of this storm (e.g., Reeves et al., 2013, https://doi.org/10.1126/science.1237743) have invoked local acceleration to explain this. However, here, we argue that the observations can instead be explained by fast inward radial transport. One method often invoked to distinguish between these two acceleration processes is the existence of local peaks in electron phase space density (PSD) as a function of L* at fixed first, M, and second, K, adiabatic invariants. However, this method relies on the assumption that the evolution of the PSD as a function of L* occurs over timescales slower than the satellite orbital period. Here, high spatiotemporal resolution data from the Global Positioning System (GPS) spacecraft constellation is used to show that enhancements in the PSD occur during the October 2012 storm over short timescales not resolvable by the Van Allen Probes. In addition, Geostationary Operational Environmental Satellite spacecraft data also indicate that these enhancements are consistent with relativistic electron injections. A radial diffusion model is shown to reproduce the PSD dynamics observed by the Van Allen Probes, once rapid variations at the simulation outer boundary are included, consistent with GPS data. This verifies that apparently “locally growing” peaks in PSD along high apogee satellite orbits can be produced by fast inward radial transport without requiring the action of any local acceleration processes.

99 GENERAL AND MISCELLANEOUS↗

Inverse Method for Estimating the Spatial Variability of Soil Particle Size Distribution from Observed Soil Moisture

Soil particle size distribution (PSD) (i.e., clay, silt, sand, and rock contents) information is one of critical factors for understanding water cycle since it affects almost all of water cycle processes, e.g., drainage, runoff, soil moisture, evaporation, and evapotranspiration. With information about soil PSD, we can estimate almost all soil hydraulic properties (e.g., saturated soil moisture, field capacity, wilting point, residual soil moisture, saturated hydraulic conductivity, pore-size distribution index, and bubbling capillary pressure) based on published empirical relationships. Therefore, a regional or global soil PSD database is essential for studying water cycle regionally or globally. At the present stage, three soil geographic databases are commonly used, i.e., the Soil Survey Geographic database, the State Soil Geographic database, and the National Soil Geographic database. Those soil data are map unit based and associated with great uncertainty. Ground soil surveys are a way to reduce this uncertainty. However, ground surveys are time consuming and labor intensive. In this study, an inverse method for estimating mean and standard deviation of soil PSD from observed soil moisture is proposed and applied to Throughfall Displacement Experiment sites in Walker Branch Watershed in eastern Tennessee. This method is based on the relationship between spatial mean and standard deviation of soil moisture. The results indicate that the suggested method is feasible and has potential for retrieving soil PSD information globally from remotely sensed soil moisture data.

54 ENVIRONMENTAL SCIENCES↗

Performance of BF{sub 3} Filled Position Sensitive Neutron Detector

{sup 3}He filled position sensitive detectors (PSD)s developed in-house are successfully used for neutron scattering studies at Dhruva. However recent global scarcity of {sup 3}He has made it essential to find an alternative. It is very difficult to meet performance capabilities of {sup 3}He for neutron detection in any of the alternate materials. Among various alternatives, BF{sub 3} gas can be one. We have recently put an effort to evaluate performance of BF{sub 3} based PSD. For that a PSD filled with BF{sub 3} gas at 0.8 bar pressure is fabricated and characterized. Performances of the same with Pu-Be source and at Hi-Q Diffractometer, Dhruva are reported in this paper. Diffraction spectra from standard samples Fe and Si at wavelength 0.783 A were recorded. It is found that while position resolution of the BF{sub 3} filled PSD is comparable but the efficiency is 20 times less than that of a {sup 3}He(12 bar) filled PSD.

36 MATERIALS SCIENCE↗

REPRODUCTION OF THE OBSERVED TWO-COMPONENT MAGNETIC HELICITY IN SOLAR WIND TURBULENCE BY A SUPERPOSITION OF PARALLEL AND OBLIQUE ALFVEN WAVES

The angular distribution of the normalized reduced magnetic helicity density ({sigma} r{sub m}) in solar wind turbulence reveals two components of distinct polarity in different angle ranges. This kind of two-component {sigma}{sup r}{sub m} may indicate the possible wave modes and power spectral densities (PSDs) of the turbulent fluctuations. Here we model the measured angular distribution of {sigma}{sup r}{sub m} by assuming a PSD distribution for Alfven fluctuations in wavevector space, and then fit the model results to the observations by adjusting the pattern of the PSD distribution. It is found that the two-component form of the PSD, which has a major and minor component close to k and k{sub ||}, respectively, seems to be responsible for the observed two-component {sigma}{sup r}{sub m}. On the other hand, both an isotropic PSD and a PSD with only a single component bending toward k fail to reproduce the observations. Moreover, it is shown that the effect of gradual balance between outward and inward wave-energy fluxes with decreasing spatial scale needs to be considered in order to reproduce the observed diminishing of |{sigma}{sup r}{sub m}| at shorter scales. Therefore, we suggest that the observed two-component {sigma}{sup r}{sub m} in the solar wind turbulence may be due to a superposition of Alfven waves with quasi-perpendicular (major part) and quasi-parallel (minor part) propagation. The waves seem to become gradually balanced toward shorter scales.

79 ASTRONOMY AND ASTROPHYSICS↗