Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Airborne bathymetric charting using pulsed blue-green lasers

Laboratory and airborne experiments have proven the feasibility and demonstrated the techniques of an airborne pulsed laser system for rapidly mapping coastal water bathymetry. Water depths of 10 plus or minus 0.25 m were recorded in waters having an effective attenuation coefficient of 0.175 m. A 2-MW peak power Nd:YAG pulsed laser was flown at an altitude of 600 m. An advanced system, incorporating a mirror scanner, a high pulsed rate laser, and a good signal processor, could survey coastal zones at the rate of several square miles per hour.

Kim, H. H.↗

An anemometer for measuring velocities on the .25 to 4.25 M/sec range

A vane type anemometer was developed as a secondary standard for the on site calibration of wind velocity sensors. The instrument outputs an electrical pulse for each interruption of a light source by an eight vane fan. The pulse rate is proportional to the fan's angular speed and linearly related to wind velocity over the range 0.25 to 4.27 m/sec.

Carpini, T. D.↗

Fresnel-Fizeau effect in a rotating optical fiber ring interferometer

Measurements of the Fresnel-Fizeau effect in a fiber ring interferometer gyroscope are reported. The presence of the dispersion term in the Fresnel drag coefficient was discernable. The temperature dependence of the coefficient bears on the temperature sensitivity of the optical fiber gyroscope. An alternate approach to measuring fiber dispersion is an added benefit, leading to determination of maximum pulse rate transmitted through single-mode fibers.

Vali, V.↗

Long-duration high-efficiency operation of a continuously pulsed copper laser utilizing copper bromide as a lasant

A copper laser utilizing copper bromide as a lasant and neon as the buffer gas has been operated at an average laser power of between 16 and 19.5 W for a period of 68 h. Lasing was attained at a pulsing rate of 16.7 kHz in a quartz discharge tube 2.5-cm in diameter with an electrode separation of 200 cm. The laser energy/pulse and peak power/pulse corresponding to an average power of 19.5 W are 1.2 mJ and 30 kW, respectively. The ratio of laser power at 510.6 and 578.2 nm varied from 3.9 to 1.1 corresponding to a total average laser power of 4 and 18 W, respectively. The highest wall plug and capacitor efficiency measured during 68 h of operation were 0.7 and 1.1%, respectively.

Chen, C. J.↗

Certain questions of the acclimatization of construction workers to the conditions of a subtropical climate

The period of active acclimatization was determined for construction workers coming into a subtropical climate. Changes were observed in metabolic processes, oxygen needs, pulse rate, arterial pressure, body and skin temperature, body weight, water consumption and loss, and the comfort zone of heat sensitivity. It was concluded that acclimatization is facilitated if introduction to the hot climate occurs in the mild cool season, rather than the summer. This also prevents heat prostration and improves the development of adaptive mechanisms.

Babayev, A.↗

Effect of prolonged hypodynamia on certain physiological functions in dogs

The behavior of 20 dogs whose mobility was restricted was experimentally investigated. Their reactions to hypodynamia were either active behavior or progressive general depression and increased muscular weakness. Arterial pressure, pressor sinocarotid reflex valve, body weight, pulse rate, body temperature, and plasma cholinesterase activity were monitered for 28 days. Results are reported.

Yaremenko, B. R.↗

Accommodations assessment: Spaceborne Doppler lidar wind measuring system

An accommodations analysis performed by the MSFC Preliminary Design Office for a spaceborne Doppler lidar wind measuring system is summarized. A dedicated, free-flying spacecraft design concept is described. Mass and beginning-of-life power requirements are estimated at 2260 kg and 6.0 - 8.5 kW respectively, to support a pulsed, CO2, Doppler lidar having a pulse energy of 10 J, pulse rate of 8 Hz, and efficiency of approximately 5%. Under the assumptions of the analysis, such a system would provide wind measurements on a global scale, with accuracies of a few meters per second.

Source record↗

Coherently pulsed laser source

An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent pulses that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device generates sound waves containing a group of frequencies which result in spaced pulses. The first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.

Margolis, J. S.↗

A shuttle scanning laser altimeter for topographic mapping

The shuttle scanning laser altimeter is an instrument, currently under development at JPL, capable of producing a three-dimensional elevation map of the topography along a wide swath beneath a spaceborne platform. Operating on the same principle as radar (broadcast of a short pulse of radiation and timing the reception of an echo) the very narrow beamwidths and high pulse rates of modern lasers would allow a significant breakthrough in the areal resolution capability of altimeters. Specifically, the copper vapor laser currently available and planned for use would provide 50 meter horizontal and 3 meter vertical resolution over a 10 kilometer continuous swath or, in a snapshot mode, a 50 kilometer square area.

Kobrick, M.↗

Submegahertz frequency-stablized Nd:YAG oscillator

The operation of a 5-msec, quasi-continuous wave (CW) 10-Hz repetition-rate pulsed single-frequency Nd:YAG oscillator with a feedback stabilized frequency bandwidth of less than 200 kHz is described. The major problems associated with frequency stabilization for quasi-CW operation, frequency chirp and maintenance of the frequency control signal, are described, and the design of a wide-bandwidth frequency locking system with a search and chirp compensation loop is given. This frequency stabilized oscillator is a potentially useful laser source for atmospheric wind velocity measurements by coherent lidar Doppler velocimetry, which require a laser source with less than 1 MHz linewidth, and also has applications in high-resolution nonlinear spectroscopic studies at Fourier-transform-limited linewidths.

Sun, Y. L.↗

Applications of excimer lasers for atmospheric species measurements

Excimer lasers are proven sources of high pulse energy and high average power coherent radiation at several wavelength regions throughout the ultraviolet spectrum. If designed properly, excimer lasers can be operated with both low divergence and narrow spectral bandwidth, and using an oscillator - injection-locked amplifier configuration they can be tuned over a 10 to 20 A bandwidth without appreciable loss in energy. Additional wavelength coverage from excimer lasers can be obtained by stimulated Raman scattering. With the development of magnetic switching for the high voltage, high power switches, the electric discharge excimer laser can also be operated reliably for extended periods of time at high pulse rates. All these features make excimer lasers ideal sources of ultraviolet radiation for a variety of remote and in-situ atmospheric species measurements.

Laudenslager, J. B.↗

MLRS - A lunar/artificial satellite laser ranging facility at the McDonald Observatory

Experience from lunar and satellite laser ranging experiments carried out at McDonald Observatory has been used to design the McDonald Laser Ranging Station (MLRS). The MLRS is a dual-purpose installation designed to obtain observations from the LAGEOS satellite and lunar targets. The instruments used at the station include a telescope assembly 0.76 meters in diameter; a Q-switched doubled neodymium YAG laser with a pulse rate of three nanoseconds; and a GaAs photodetector with Fabry-Perot interferometric filter. A functional diagram of the system is provided. The operating parameters of the instruments are summarized in a table.

Shelus, P. J.↗

Spectroscopic aspects of differential method for sounding gas composition of the atmosphere

The problems concerning the dynamics of populations of the sounded atmospheric gas molecule levels taking into account the nonmonochromatic character of radiation, durations of exciting and sounding pulses, rates of relaxation of excited vibration-rotation states population along different channels in a natural multicomponent mixture of gases and air were investigated. The problems of spectroscopic software, completeness and accuracy of the initial spectroscopic information, information on channels and rates of relaxation from the viewpoint of developing specific schemes of sounding are discussed. The values of deviations of vibration-rotation level populations of some atmospheric molecules from their equilibrium value at simultaneous action of double frequency radiation on the sounding path and the corresponding dynamic variation of lidar return amplitude were estimated. The importance of nonlinear spectrosopic effects in the lidar return value variation at sounding radiation frequency equaling the resonance frequency of vibration-rotation transition in the problem on sounding the humidity profiles and concentrations of gaseous pollutants was also estimated.

Zuev, V. V.↗

AlGaAs growth by OMCVD using an excimer laser

AlGaAs has been grown on GaAs by laser assisted OMCVD using an excimer laser, wavelength 193 nm, and a Cambridge OMCVD reactor. Films were grown at temperatures of 450 and 500 C with the laser beam parallel to the surface and impinging onto the surface at 15 deg from parallel. The samples were heated by RF coils while the laser beam was perpendicular to the gas flow. Typical gas flow parameters are 12 slm of H2, 15 sccm of Ga(CH3)3, 13 sccm of Al(CH3)3, and a pressure of 250 mbar. The initial energy density of the beam at the surface was 40 mJ/sq cm, the pulse rate was 20 pps, and the growth time was 7 min. The films were analyzed by Auger electron spectroscopy for the aluminum concentration and by TEM for the surface morphology.

Warner, Joseph D.↗

Application of low-power, high-rate PCM telemetry in a helicopter instrumentation system

The use of low-power, high-rate pulse code modulation (PCM) in a helicopter instrumentation system is examined. A Helicopter Instrumentation and Recording System (HIARS) was developed to obtain main rotor blade measurements and fuselage performance measurements. The HIARS consists of a low-power PCM telemeter, a digital PCM system, an optical rotor position sensor, and a PCM decommutation unit; the components and functions of these subsystems are described. Flight tests were conducted to evaluate the ability of the HIARS to measure aircraft parameters. The test data reveal that the PCM telemetry is applicable to helicopter instrumentation systems.

Thomas, Mitchel E.↗

Microcirculatory fluid dynamics in weightlessness and simulated weightlessness

The method of Smith et al. (1985), which makes it possible to simultaneously measure the macrocirculation and microcirculation in an unanesthetized rat, was used to study the effect of acute hypokinesia on the rat microvascular system. The measurements yielded values of the length, diameter, and number of arteriolar and venular vessels; vascular patterns; branching ratios; and the amplitude and frequency of vasomotion. Early effects (30-60 min after the start of the head-down tilt) include a 10 percent increase in the diameter of arterioles, a slight increase of heart rate and mean arterial blood pressure, and an increase in the heart rate-pulse pressure product, with most of the changes returning to normal after 2-3 h. The baroreceptor reflex index was reduced by almost 50 percent for the first 2 h, but rebounded to almost 3 times the control value after 3 h. This indicates that, in spite of relatively small changes in gross hemodynamic parameters, the cardiovascular function is altered significantly during the acute phase of hypokinesia.

Hutchins, P. M.↗

Single longitudinal mode operation of semiconductor laser arrays with etalon feedback

The multiple longitudinal mode output of high-power diode-laser arrays is converted into single mode with 97 percent efficiency by optical feedback from a thin (less than 200-micron thick) etalon external to the laser. The coupled cavities formed by addition of the etalon favor a single longitudinal mode. Single-mode operation is retained at 0.1 MHz pulsed rates. Both the near-field and the far-field patterns of the laser array remain nearly unchanged while the array operates in a single longitudinal mode.

Hemmati, H.↗

Lightning flashes triggered in altitude by the rocket and wire technique

Electrical measurements were conducted in 1987 and 1988 on streamer and leader discharges occurring during the first stages of a triggered flash. This paper describes the pulsing phenomenon observed at positive leader onset (typical pulsing rate 25 microns), and it is shown that the same process happened in the case of the ignition of a flash triggered in altitude; with a wire several hundred meters long, positive leader propagates alone for several ms before the ignition of the downward negative stepped leader.

Laroche, P.↗