Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Track Output”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

WE-EF-303-05: Development and Commissioning of Real-Time Imaging Function for Respiratory-Gated Spot-Scanning Proton Beam Therapy

Purpose: To realize real-time-image gated proton beam therapy (RGPT) for treating mobile tumors. Methods: The rotating gantry of spot scanning proton beam therapy has been designed to equip two x-ray fluoroscopy devices that enable real-time imaging of the internal fiducial markers during respiration. Three-dimensional position of the fiducial marker located near the tumor can be calculated from the fluoroscopic images obtained from orthogonal directions and therapeutic beam is gated only when the fiducial marker is within the predefined gating window. Image acquisition rate can be selected from discrete value ranging from 0.1 Hz to 30 Hz. In order to confirm the effectiveness of RGPT and apply it clinically, clinical commissioning was conducted. Commissioning tests were categorized to main three parts including geometric accuracy, temporal accuracy and dosimetric evaluation. Results: Developed real-time imaging function has been installed and its basic performances have been confirmed. In the evaluation of geometric accuracy, coincidence of three-dimensional treatment room coordinate system and imaging coordinate system was confirmed to be less than 1 mm. Fiducial markers (gold sphere and coil) were able to be tracked in simulated clinical condition using an anthropomorphic chest phantom. In the evaluation of temporal accuracy, latency from image acquisition to gate on/off signal was about 60 msec in typical case. In dosimetric evaluation, treatment beam characteristics including beam irradiation position and dose output were stable in gated irradiation. Homogeneity indices to the mobile target were 0.99 (static), 0.89 (w/o gating, motion is parallel to direction of scan), 0.75 (w/o gating, perpendicular), 0.98 (w/ gating, parallel) and 0.93 (w/ gating, perpendicular). Dose homogeneity to the mobile target can be maintained in RGPT. Conclusion: Real-time imaging function utilizing x-ray fluoroscopy has been developed and commissioned successfully in order to realize RGPT. Funding Support: This research was partially supported by Japan Society for the Promotion of Science (JSPS) through the FIRST Program. Conflict of Interest: Prof. Shirato has research fund from Hitachi Ltd, Mitsubishi Heavy Industries Ltd and Shimadzu Corporation.

60 APPLIED LIFE SCIENCES↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Magnetic tweezers with high permeability electromagnets for fast actuation of magnetic beads

As a powerful and versatile scientific instrument, magnetic tweezers have been widely used in biophysical research areas, such as mechanical cell properties and single molecule manipulation. If one wants to steer bead position, the nonlinearity of magnetic properties and the strong position dependence of the magnetic field in most magnetic tweezers lead to quite a challenge in their control. In this article, we report multi-pole electromagnetic tweezers with high permeability cores yielding high force output, good maneuverability, and flexible design. For modeling, we adopted a piece-wise linear dependence of magnetization on field to characterize the magnetic beads. We implemented a bi-linear interpolation of magnetic field in the work space, based on a lookup table obtained from finite element simulation. The electronics and software were custom-made to achieve high performance. In addition, the effects of dimension and defect on structure of magnetic tips also were inspected. In a workspace with size of 0.1 × 0.1 mm{sup 2}, a force of up to 400 pN can be applied on a 2.8 μm superparamagnetic bead in any direction within the plane. Because the magnetic particle is always pulled towards a tip, the pulling forces from the pole tips have to be well balanced in order to achieve control of the particle’s position. Active video tracking based feedback control is implemented, which is able to work at a speed of up to 1 kHz, yielding good maneuverability of the magnetic beads.

36 MATERIALS SCIENCE↗

Adaptation of the modified Bouc–Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: Testing using MRI

Purpose: Binning list-mode acquisitions as a function of a surrogate signal related to respiration has been employed to reduce the impact of respiratory motion on image quality in cardiac emission tomography (SPECT and PET). Inherent in amplitude binning is the assumption that there is a monotonic relationship between the amplitude of the surrogate signal and respiratory motion of the heart. This assumption is not valid in the presence of hysteresis when heart motion exhibits a different relationship with the surrogate during inspiration and expiration. The purpose of this study was to investigate the novel approach of using the Bouc–Wen (BW) model to provide a signal accounting for hysteresis when binning list-mode data with the goal of thereby improving motion correction. The study is based on the authors’ previous observations that hysteresis between chest and abdomen markers was indicative of hysteresis between abdomen markers and the internal motion of the heart. Methods: In 19 healthy volunteers, they determined the internal motion of the heart and diaphragm in the superior–inferior direction during free breathing using MRI navigators. A visual tracking system (VTS) synchronized with MRI acquisition tracked the anterior–posterior motions of external markers placed on the chest and abdomen. These data were employed to develop and test the Bouc–Wen model by inputting the VTS derived chest and abdomen motions into it and using the resulting output signals as surrogates for cardiac motion. The data of the volunteers were divided into training and testing sets. The training set was used to obtain initial values for the model parameters for all of the volunteers in the set, and for set members based on whether they were or were not classified as exhibiting hysteresis using a metric derived from the markers. These initial parameters were then employed with the testing set to estimate output signals. Pearson’s linear correlation coefficient between the abdomen, chest, average of chest and abdomen markers, and Bouc–Wen derived signals versus the true internal motion of the heart from MRI was used to judge the signals match to the heart motion. Results: The results show that the Bouc–Wen model generated signals demonstrated strong correlation with the heart motion. This correlation was slightly larger on average than that of the external surrogate signals derived from the abdomen marker, and average of the abdomen and chest markers, but was not statistically significantly different from them. Conclusions: The results suggest that the proposed model has the potential to be a unified framework for modeling hysteresis in respiratory motion in cardiac perfusion studies and beyond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmic ray muon clustering for the MicroBooNE liquid argon time projection chamber using sMask-RCNN

In this article, we describe a modified implementation of Mask Region-based Convolutional Neural Networks (Mask-RCNN) for cosmic ray muon clustering in a liquid argon TPC and applied to MicroBooNE neutrino data. Our implementation of this network, called sMask-RCNN, uses sparse submanifold convolutions to increase processing speed on sparse datasets, and is compared to the original dense version in several metrics. The networks are trained to use wire readout images from the MicroBooNE liquid argon time projection chamber as input and produce individually labeled particle interactions within the image. These outputs are identified as either cosmic ray muon or electron neutrino interactions. We find that sMask-RCNN has an average pixel clustering efficiency of 85.9% compared to the dense network's average pixel clustering efficiency of 89.1%. We demonstrate the ability of sMask-RCNN used in conjunction with MicroBooNE's state-of-the-art Wire-Cell cosmic tagger to veto events containing only cosmic ray muons. The addition of sMask-RCNN to the Wire-Cell cosmic tagger removes 70% of the remaining cosmic ray muon background events at the same electron neutrino event signal efficiency. This event veto can provide 99.7% rejection of cosmic ray-only background events while maintaining an electron neutrino event-level signal efficiency of 80.1%. In addition to cosmic ray muon identification, sMask-RCNN could be used to extract features and identify different particle interaction types in other 3D-tracking detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic ray muon clustering for the MicroBooNE liquid argon time projection chamber using sMask-RCNN

In this article, we describe a modified implementation of Mask Region-based Convolutional Neural Networks (Mask-RCNN) for cosmic ray muon clustering in a liquid argon TPC and applied to MicroBooNE neutrino data. Our implementation of this network, called sMask-RCNN, uses sparse submanifold convolutions to increase processing speed on sparse datasets, and is compared to the original dense version in several metrics. The networks are trained to use wire readout images from the MicroBooNE liquid argon time projection chamber as input and produce individually labeled particle interactions within the image. These outputs are identified as either cosmic ray muon or electron neutrino interactions. We find that sMask-RCNN has an average pixel clustering efficiency of 85.9% compared to the dense network's average pixel clustering efficiency of 89.1%. We demonstrate the ability of sMask-RCNN used in conjunction with MicroBooNE's state-of-the-art Wire-Cell cosmic tagger to veto events containing only cosmic ray muons. The addition of sMask-RCNN to the Wire-Cell cosmic tagger removes 70% of the remaining cosmic ray muon background events at the same electron neutrino event signal efficiency. Furthermore, this event veto can provide 99.7% rejection of cosmic ray-only background events while maintaining an electron neutrino event-level signal efficiency of 80.1%. In addition to cosmic ray muon identification, sMask-RCNN could be used to extract features and identify different particle interaction types in other 3D-tracking detectors.

47 OTHER INSTRUMENTATION↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Particle-Tracking Proton Computed Tomography—Data Acquisition, Preprocessing, and Preconditioning

Proton CT (pCT) is a promising new imaging technique that can reconstruct relative stopping power (RSP) more accurately than x-ray CT in each cubic millimeter voxel of the patient. This, in turn, will result in better proton range accuracy and, therefore, smaller planned tumor volumes (PTV). The hardware description and some reconstructed images have previously been reported. In a series of two contributions, we focus on presenting the software algorithms that convert pCT detector data to the final reconstructed pCT images for application in proton treatment planning. There were several options on how to accomplish this, and we will describe our solutions at each stage of the data processing chain. In the first paper of this series, we present the data acquisition with the pCT tracking and energy-range detectors and how the data are preprocessed, including the conversion to the well-formatted track information from tracking data and water-equivalent path length from the data of a calibrated multi-stage energy-range detector. These preprocessed data are then used for the initial image formation with an FDK cone-beam CT algorithm. The output of data acquisition, preprocessing, and FDK reconstruction is presented along with illustrative imaging results for two phantoms, including a pediatric head phantom. The second paper in this series will demonstrate the use of iterative solvers in conjunction with the superiorization methodology to further improve the images resulting from the upfront FDK image reconstruction and the implementation of these algorithms on a hybrid CPU/GPU computer cluster.

42 ENGINEERING↗

Utilizing HYSPLIT for Emergency Response Modeling at SRS

The threat of a disaster happening at the Savannah River Site (SRS) is low, but not zero. When an emergency arises, emergency responders utilize a variety of tools to detect, track, and mitigate the disaster. HYSPLIT is a community atmospheric dispersion model that is highly configurable and has been used operationally to simulate particle, chemical, and radionuclide releases. We have developed a preliminary user interface (UI) that configures HYSPLIT to run for a variety of Emergency Action Level (EAL) scenarios at SRS. Using a hypothetical EAL scenario of an accidental release of Pu-238 in H-area and K-area onsite, an analysis was done to show how a preliminary UI framework allows HYSPLIT to be run on a terminal without the need form an active network connection. The study was successful in multiple aspects. For the preliminary UI, users were able to input certain characteristics of the hypothetical EAL such as hours of emission (how long was Pu-238 being released), curies of release, release start time (when does the model run start), and type of radionuclide directly into the terminal. For HYSPLIT, the model was successful in being able to take the UI input, calculate the results from the inputs and output multiple figures of both total volumetric airborne concentrations and surface deposition. We used the Pu-238 Derived Intervention Level (DIL) deposition thresholds for produce, dairy, and beef for visualization of the surface deposition, showing how a release would impact ingestion pathways.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mixed-Material Scintillators (MMSS Quarterly Report FY20Q2)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection. This quarter, we delivered one the MMSS Particle-ID Modeling report, a major deliverable of this project. This report describes our results on simulations of the particle-ID (PID) class of detectors. We found that these detectors outperform competing approaches for neutron-gamma discrimination, neutron source pointing, and neutron spectroscopy. Further highlights of the report are described below. During this quarter, We alerted HQ to a change in schedule for the remaining simulations planned for this project: we plan to put off further simulation and reporting of the position-resolving (PR) detector class until July. This change in schedule has allowed us to go into additional detail in the PID work that is both very promising and motivates our upcoming proposal. The other active task in this project is prototyping 3D-printed scintillators with the aim of realizing the designs we’ve simulated. On that front, we had three focuses: measuring the light output, increasing the size of printed parts, and combining blue and green scintillators. We succeeded in measuring the light output, showing an output of 30% of commercial standard. This result leaves room for improvement but is within striking distance of where we need to be. We were on track to demonstrate a key requirement for increasing the size of parts and also to show combined green/blue prints before the laboratory moved to a Minimum Safe (MinSafe) Operations posture as a result of local Shelter In Place orders due to Covid-19.

42 ENGINEERING↗

High-speed spiral imaging technique for an atomic force microscope using a linear quadratic Gaussian controller

This paper demonstrates a high-speed spiral imaging technique for an atomic force microscope (AFM). As an alternative to traditional raster scanning, an approach of gradient pulsing using a spiral line is implemented and spirals are generated by applying single-frequency cosine and sine waves of slowly varying amplitudes to the X and Y-axes of the AFM’s piezoelectric tube scanner (PTS). Due to these single-frequency sinusoidal input signals, the scanning process can be faster than that of conventional raster scanning. A linear quadratic Gaussian controller is designed to track the reference sinusoid and a vibration compensator is combined to damp the resonant mode of the PTS. An internal model of the reference sinusoidal signal is included in the plant model and an integrator for the system error is introduced in the proposed control scheme. As a result, the phase error between the input and output sinusoids from the X and Y-PTSs is reduced. The spirals produced have particularly narrow-band frequency measures which change slowly over time, thereby making it possible for the scanner to achieve improved tracking and continuous high-speed scanning rather than being restricted to the back and forth motion of raster scanning. As part of the post-processing of the experimental data, a fifth-order Butterworth filter is used to filter noises in the signals emanating from the position sensors and a Gaussian image filter is used to filter the images. A comparison of images scanned using the proposed controller (spiral) and the AFM PI controller (raster) shows improvement in the scanning rate using the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermalization of nuclear matter in heavy-ion collisions at Fermi energies

We analyze the time evolution of the kinetic properties of nuclear matter produced in heavy-ion collisions at Fermi energies. The collision system is simulated using Constrained Molecular Dynamics (CoMD) transport calculations whose output is the isospin, position, and momentum of the nucleons. Focusing on central 35 A·MeV 40 Ca+ 40 Ca collisions we utilize this information to extract localized momentum distributions in volume elements of 8 fm 3 and time steps of 5 fm/$c$. We then parameterize the single-particle momentum distributions with thermally motivated fit functions in the local rest frame of each cell. While the transverse-momentum distributions are well reproduced by thermal ones, the longitudinal ones carry a marked imprint of the initial nuclear motion which we capture by introducing a centroid motion into our fit functions. In particular, we find that Fermi distributions yield significantly better fits than Boltzmann ones, a consequence of the Pauli blocking implemented in CoMD. From the fits we extract the time dependence of the thermodynamic and collective properties of the excited nuclear medium. We find that the transverse temperature gradually rises to about 6 MeV, which is accompanied by a dissipation of the initial centroid motion of the incoming nuclei which vanishes at about 100 fm/c after initial impact. In conclusion, we are therefore able to track the transition of beam energy into random kinetic energy for nucleons, suggesting a three-dimensional equilibration of energy in the late stages of the collision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TU-A-9A-03: Development and Verification of a Forward Model That Assists in Iterative Post-Processing Algorithms Used to Reduce Blur in Compton Backscatter Imaging Systems

Purpose: In Compton Backscatter Imaging (CBI), the source and detector reside on the same side of the patient. We previously demonstrated the applicability of CBI systems for medical purposes using an industrial system. To assist in post-processing images from a CBI system, a forward model based on radiation absorption and scatter principles has been developed. Methods: The forward model was developed in C++ using raytracing to track particles. The algorithm accepts phantoms of any size and resolution to calculate the fraction of incident photons scattered back to the detector, and can perform these calculations for any detector geometry and source specification. To validate the model, results were compared to MCNP-X, which is a Monte Carlo based simulation software, for various combinations of source specifications, detector geometries, and phantom compositions. Results: The model verified that the backscatter signal to the detector was based on three interaction probabilities: a) attenuation of photons going into the phantom, b) Compton scatter of photons toward the detector, and c) attenuation of photons coming out of the phantom. The results from the MCNP-X simulations and the forward model varied from 1 to 5%. This difference was less than 1% for energies higher than 30 keV, but was up to 4% for lower energies. At 50 keV, the difference was less than 1% for multiple detector widths and for both homogeneous and heterogeneous phantoms. Conclusion: As part of the optimization of a medical CBI system, an efficient and accurate forward model was constructed in C++ to estimate the output of CBI system. The model characterized individual components contributing to CBI output and increased computational efficiency over Monte Carlo simulations. It is now used in the development of novel post-processing algorithms that reduce image blur by reversing undesired contribution from outside the region of interest.

07 ISOTOPE AND RADIATION SOURCES↗

Twin-pulse seeding enables pump-probe capabilities in the EUV to soft X-ray spectrum at synchrotron light sources

Having previously reported that separating the two stages of echo-enabled harmonic generation (EEHG) with one or more bending magnet (BM) sections allows the BMs to serve as the desired source of momentum compaction, here we demonstrate that this arrangement can greatly reduce the total energy modulation required by any 4th generation synchrotron light source, leading to higher repetition rates as well as stronger coherent radiation output power, with significant benefits. Since the EEHG beamline performance is mainly determined by the momentum compaction, beam emittances and beta functions of a storage ring lattice, allowing for different separations between the two stages is a straightforward way to increase the momentum compaction of chicane 1. This also enables pump-probe capabilities in a novel context, where twin-pulse seeding on the same electron bunch would allow two distinct radiation pulses with an adjustable delay in the range of 0.1 to 10 ps. In the twin-pulse seeding scheme, the same electron bunch could undergo modulation from two distinct laser pulses. Later stages would produce independent harmonics in subsequent straight sections. There are two variations of this twin-pulse seeding scheme, supporting different scientific applications. With a common modulation in stage 1, the first option allows simultaneously two independent radiation sources, with a full coverage of the EUV (2.5 to 50 nm) to soft X-ray (1.25 to 2.5 nm) spectrum; for the second option, the same stage 2 undulator could generate two coherent pulses both fitting within the FEL bandwidth, or at distinct harmonics. We present particle tracking simulation studies based on the APS-U lattice, including quantum excitation and radiation damping. These simulations indicate that there is no degradation of the modulated longitudinal phase space even when the two stages are separated by as many as 10 BM sections.

36 MATERIALS SCIENCE↗

SU-F-T-464: Development of a Secondary Check Procedure to Evaluated Flatness and Symmetry Discrepancies Detected During Daily Morning QA

Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data for offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.

60 APPLIED LIFE SCIENCES↗

The CMS Phase 2 Outer Tracker Analyzer of Test Outputs - POTATO!

The Phase-2 upgrade of the Large Hadron Collider (LHC), also known as the High-Luminosity LHC (HL-LHC) is designed to achieve peak instantaneous luminosities which is about an order of magnitude higher than the nominal design value of $10^{34}~cm^{-2}s^{-1}$ delivering a total of atleast $3000 fb^{-1}$ data over 10 years of operation at $\sqrt{s}~=~14~TeV$. One crucial aspect of the CMS Phase-2 detector upgrade is the replacement of the existing tracking detector in order to deal with the extreme HL-LHC conditions, retaining and further expanding the physics performances achieved in the previous years. The outer part of the upgraded tracker (OT), will be equipped with over 13,000 macro Pixel-Strip (PS) and Strip-Strip (2S) modules! Module production is distributed across centers worldwide and necessitates coordinated efforts and standardized procedures. Along with production and assembly of the modules, Fermilab OT group is also working on a tool, Phase 2 Outer Tracker Analyzer of Test Outputs (POTATO) that will analyze, grade, upload and manage the large quantity of files to be stored in the centralized Database (DB). In this contribution a brief overview of the module testing and the power and dire need of POTATO to handle this large number of test outputs will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CMS Phase 2 Outer Tracker Analyzer of Test Outputs - POTATO!

The Phase-2 upgrade of the Large Hadron Collider (LHC), also known as the High-Luminosity LHC (HL-LHC) is designed to achieve peak instantaneous luminosities which is about an order of magnitude higher than the nominal design value of $10^{34}~cm^{-2}s^{-1}$ delivering a total of atleast $3000 fb^{-1}$ data over 10 years of operation at $\sqrt{s}~=~14~TeV$. One crucial aspect of the CMS Phase-2 detector upgrade is the replacement of the existing tracking detector in order to deal with the extreme HL-LHC conditions, retaining and further expanding the physics performances achieved in the previous years. The outer part of the upgraded tracker (OT), will be equipped with over 13,000 macro Pixel-Strip (PS) and Strip-Strip (2S) modules! Module production is distributed across centers worldwide and necessitates coordinated efforts and standardized procedures. Along with production and assembly of the modules, Fermilab OT group is also working on a tool, Phase 2 Outer Tracker Analyzer of Test Outputs (POTATO) that will analyze, grade, upload and manage the large quantity of files to be stored in the centralized Database (DB). In this contribution a brief overview of the module testing and the power and dire need of POTATO to handle this large number of test outputs will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DNA Extraction by Isotachophoresis in a Microfluidic Channel

Biological assays have many applications. For example, forensics personnel and medical professionals use these tests to diagnose diseases and track their progression or identify pathogens and the host response to them. One limitation of these tests, however, is that most of them target only one piece of the sample - such as bacterial DNA - and other components (e.g. host genomic DNA) get in the way, even though they may be useful for different tests. To address this problem, it would be useful to extract several different substances from a complex biological sample - such as blood - in an inexpensive and efficient manner. This summer, I worked with Maxim Shusteff at Lawrence Livermore National Lab on the Rapid Automated Sample Prep project. The goal of the project is to solve the aforementioned problem by creating a system that uses a series of different extraction methods to extract cells, bacteria, and DNA from a complex biological sample. Biological assays can then be run on purified output samples. In this device, an operator could input a complex sample such as blood or saliva, and would receive separate outputs of cells, bacteria, viruses, and DNA. I had the opportunity to work this summer with isotachophoresis (ITP), a technique that can be used to extract nucleic acids from a sample. This technique is intended to be the last stage of the purification device. Isotachophoresis separates particles based on different electrophoretic mobilities. This technique is convenient for out application because free solution DNA mobility is approximately equal for DNA longer than 300 base pairs in length. The sample of interest - in our case DNA - is fed into the chip with streams of leading electrolyte (LE) and trailing electrolyte (TE). When an electric field is applied, the species migrate based on their electrophoretic mobilities. Because the ions in the leading electrolyte have a high electrophoretic mobility, they race ahead of the slower sample and trailing electrolyte ions. Conversely, the trailing electrolyte ions have a slow electrophoretic mobility, so they lag behind the sample, thus trapping the species of interest between the LE and TE streams. In a typical isotachophoresis configuration, the electric field is applied in a direction parallel to the direction of flow. The species then form bands that stretch across the width of the channel. A major limitation of that approach is that only a finite amount of sample can be processed at once, and the sample must be processed in batches. For our purposes, a form of free-flow isotachophoresis is more convenient, where the DNA forms a band parallel to the edges of the channel. To achieve this, in our chip, the electric field is applied transversely. This creates a force perpendicular to the direction of flow, which causes the different ions to migrate across the flow direction. Because the mobility of the DNA is between the mobility of the leading and the trailing electrolyte, the DNA is focused in a tight band near the center of the channel. The stream of DNA can then be directed to a different output to produce a highly concentrated outlet stream without batch processing. One hurdle that must be overcome for successful ITP is isolating the electrochemical reactions that result from the application of high voltage for the actual process of isotachophoresis. The electrochemical reactions that occur around metal electrodes produce bubbles and pH changes that are detrimental to successful ITP. The design of the chips we use incorporates polyacrylamide gels to serve as electrodes along the central channel. For our design, the metal electrodes are located away from the chip, and high conductivity buffer streams carry the potential to the chip, functioning as a 'liquid electrode.' The stream then runs alongside a gel barrier. The gel electrode permits ion transfer while simultaneously isolating the separation chamber from any contaminants in the outer, 'liquid electrode' streams. The difference in potential from one side of the chip to the other creates an electric field. This field traverses the inner, separation channel, containing the leading electrolyte, the trailing electrolyte, and the sample of interest (DNA). To increase the ease of use of the chips, a newer chip design has been fabricated. This design has wire electrodes integrated on the chip, rather than elsewhere. To keep the pH changes and bubbling isolated from the separation channel, the chip contains deeper wells near the electrodes so that the flowing buffer can wash away any gases that form around the electrode. This design is significantly more compact because it eliminates the cumbersome electrode boxes. Eliminating the electrode boxes also decreases the required voltage, making the experiments safer. This happens because when the 'liquid electrode' streams travel through small diameter tubing, they lose much of their voltage due to the electrical resistance of the fluid in the tubing.

42 ENGINEERING↗