Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Contamination monitoring of the OSIRIS-REx ISO5 asteroid sample cleanroom

The OSIRIS-REx mission to asteroid Bennu successfully collected hundreds of grams of asteroid regolith in October 2020 [1]. The spacecraft departed Bennu in May 2021 for Earth return and will release the sample canister to be recovered in Utah in September 2023 [2]. Samples will be transported to the curation facility at NASA Johnson Space Center, where an ISO5 equivalent cleanroom has been designed in 2017 and completed in 2021. Aspects of the design and material selection for the cleanroom and its supporting facilities (air handling system, cleanroom floors and walls, filters, paints, etc.) were optimized to minimize effects of organic and inorganic contaminants and offgassing [3]. Since its completion, the lab has been carefully monitored to understand and establish a baseline with respect to multiple environmental aspects – measurement of particle counts, deploying Si wafer witness plates for organic and inorganic contaminants, deploying aluminum foils for a focus on organics with JSC in-house expertise, gas samples, and regular microbial and fungal measurements on selected surfaces and air samples in the cleanroom. This contribution will report on nearly one year of monitoring and highlight several specific aspects that have led to a better understanding of the new cleanroom environment.

carbonaceous asteroid↗

Examination of Lunar Regolith Simulants By SEM-EDS and Imaging Raman Spectroscopy

The Artemis series lunar missions will include sample returns from the lunar south pole. Lunar regolith simulants (RS) generated in the lab provide opportunities to compare two surface science techniques: scanning electron microscopy (SEM-EDS) and Raman induced surface spectroscopy. The results will also be applicable for supporting future commercial lunar payload services (CLPS) and Artemis surface. Surface characterization contributes to continued development of lunar regolith studies and adds to various regolith databases. In characterizing various lunar regolith simulants, part of the aim should be to standardize techniques and utilize anticipated methods available for astromaterials studied during, or returned from, upcoming missions, particularly samples collected from the Moon’s south pole and permanently shadowed regions (PSRs).. An initial survey of available simulants has been started with Raman scanning process for particle counting the results of which will enrich the NASA-JSC Simulant Development Lab (SDL) simulant properties database and the Colorado School of Mines Planetary Simulant Data Base. An SEM-EDS dataset of raw regolith simulant materials are collected.

Raman Microscopy↗

Insights From Routine Microbiological Monitoring of Air in Astromaterials Curation Cleanrooms

NASA maintains nine separate cleanrooms at the Johnson Space Center to curate and preserve astromaterials samples. Routine microbial monitoring of the surfaces in these cleanrooms began in 20181. Until recently, materials compatibility requirements prevented monitoring airborne biological particles in all but one of these cleanrooms. New astromaterials collections from carbon rich asteroids are more susceptible to biological degradation than previous collections. Therefore, it is important to monitor the bioburden in the air and on surfaces in these labs. Establishing a comprehensive microbial monitoring program will help inform the monitoring and curation plans for Mars sample return which will include samples that are extremely biologically sensitive. In April of 2022 we began routinely collecting air samples in seven of the nine curation cleanrooms (Meteorite ISO 7 equivalent, Lunar ISO 6 equivalent, Stardust, Hayabusa2, OSIRIS-REx ISO 5 equivalent, and Genesis ISO 4 equivalent) using a sampling device that collects airborne biological particles on an electret filter instead conventional sampler that collect cells in a liquid media or onto organic rich Petri dishes. Electret is a generic term for electrostatically charged media. The charge on these materials increases particle trapping when compared to non-charged filters of similar thickness. N95 respirators also use electret filters. This dry sample collection method allows us to meet materials requirements for all the curation labs and reduces the risk of inadvertently introducing contamination as part of our monitoring effort. This method also allows us to preserve a portion of each sample for DNA extraction and next generation sequencing. DNA sequencing helps us to characterize the portion of the cleanroom microbiome that we cannot culture. We will present the results of our first 8 months of monitoring, compare these results to particle counts in the labs and to measurements made directly onto Petri dishes when possible. We will also make recommendations for modifications to the sampling method to improve sampling efficiency and preserve diversity.

A. B. Regberg↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Fluorescent Particle Vertical Profiles (Counts and Fractions) at SAIL

This dataset contains vertically resolved fluorescent aerosol number concentrations and fluorescent fractions of total aerosol number concentrations measured with the ARM Tethered Balloon System during the Surface Atmosphere Integrated Field Laboratory campaign near Gothic, Colorado. Measurements were collected during April and June 2023 as part of the ARM–EMSL FICUS project “Characterization of the Aerobiome during the ARM Surface-Atmosphere Integrated Laboratory Campaign,” which was designed to characterize the vertical distribution of bioaerosol-relevant particles in the Colorado River Basin. The dataset includes profiles of fluorescent particle concentrations measured with a Fluorescent Portable Optical Particle Sizer (FPOPS) in the approximately 0.5–3 µm diameter range. For fluorescent fractions of total aerosol number concentrations, we compare FPOPS measurements to POPS on the same TBS flight.

Fluorescent particle concentration↗

Calibration correction of an active scattering spectrometer probe to account for refractive index of stratospheric aerosols

The use of the active scattering spectrometer probe (ASAS-X) to measure sulfuric acid aerosols on U-2 and ER-2 research aircraft has yielded results that are at times ambiguous due to the dependence of particles' optical signatures on refractive index as well as physical dimensions. The calibration correction of the ASAS-X optical spectrometer probe for stratospheric aerosol studies is validated through an independent and simultaneous sampling of the particles with impactors; sizing and counting of particles on SEM images yields total particle areas and volumes. Upon correction of calibration in light of these data, spectrometer results averaged over four size distributions are found to agree with similarly averaged impactor results to within a few percent: indicating that the optical properties or chemical composition of the sample aerosol must be known in order to achieve accurate optical aerosol spectrometer size analysis.

Pueschel, R. F.↗

Analysis of counting errors in the phase/Doppler particle analyzer

NASA is investigating the application of the Phase Doppler measurement technique to provide improved drop sizing and liquid water content measurements in icing research. The magnitude of counting errors were analyzed because these errors contribute to inaccurate liquid water content measurements. The Phase Doppler Particle Analyzer counting errors due to data transfer losses and coincidence losses were analyzed for data input rates from 10 samples/sec to 70,000 samples/sec. Coincidence losses were calculated by determining the Poisson probability of having more than one event occurring during the droplet signal time. The magnitude of the coincidence loss can be determined, and for less than a 15 percent loss, corrections can be made. The data transfer losses were estimated for representative data transfer rates. With direct memory access enabled, data transfer losses are less than 5 percent for input rates below 2000 samples/sec. With direct memory access disabled losses exceeded 20 percent at a rate of 50 samples/sec preventing accurate number density or mass flux measurements. The data transfer losses of a new signal processor were analyzed and found to be less than 1 percent for rates under 65,000 samples/sec.

Oldenburg, John R.↗

Fundamental Research Applied To Enable Hardware Performance in Microgravity

NASA sponsors microgravity research to generate knowledge in physical sciences. In some cases, that knowledge must be applied to enable future research. This article describes one such example. The Dust and Aerosol measurement Feasibility Test (DAFT) is a risk-mitigation experiment developed at the NASA Glenn Research Center by NASA and ZIN Technologies, Inc., in support of the Smoke Aerosol Measurement Experiment (SAME). SAME is an investigation that is being designed for operation in the Microgravity Science Glovebox aboard the International Space Station (ISS). The purpose of DAFT is to evaluate the performance of P-Trak (TSI Incorporated, Shoreview, MN)--a commercially available condensation nuclei counter and a key SAME diagnostic- -in long-duration microgravity because of concerns about its ability to operate properly in that environment. If its microgravity performance is proven, this device will advance the state of the art in particle measurement capabilities for space vehicles and facilities, such as aboard the ISS. The P-Trak, a hand-held instrument, can count individual particles as small as 20 nm in diameter in an aerosol stream. Particles are drawn into the device by a built-in suction pump. Upon entering the instrument, these particles pass through a saturator tube where they mix with an alcohol vapor (see the following figure). This mixture then flows through a cooled condenser tube where some of the alcohol condenses onto the sample particles, and the droplets grow in a controlled fashion until they are large enough to be counted. These larger droplets pass through an internal nozzle and past a focused laser beam, producing flashes of light that are sensed by a photodetector and then counted to determine particle number concentration. The operation of the instrument depends on the proper internal flow and recycling of isopropyl alcohol in both the vapor and liquid phases.

Sheredy, William A.↗

Cleanroom air sampler counts, categorizes, and records particle data

Light scattering particle counter monitors particles in a clean room. It categorizes and records the particles according to size and functions simultaneously in three separate areas. The counter uses a transducer head to transform light signals into electric signals.

Nelson, M. B.↗

End-to-end test of the electron-proton spectrometer

A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.

Cash, B. L.↗

A Study of the Effects of Relative Humidity on Small Particle Adhesion to Surfaces

Ambient dust ranging in size from less than one micron up to 140 microns was used as test particles. Relative humidities of 33% to 100% were used to condition test surfaces after loading with the test particles. A 20 psi nitrogen blowoff was used as the removal mechanism to test for particle adhesion. Particles were counted before and after blowoff to determine retention characteristics. Particle adhesion increased drastically as relative humidity increased above 50%. The greatest adhesion changes occurred within the first hour of conditioning time. Data are presented for total particle adhesion, for particles 10 microns and larger, and 50 microns and larger.

Whitfield, W. J.↗

Evaluation of XCT for Matrix Density Measurement of Particle Fuel Forms

Particle fuel forms generally consist of a dispersion of fuel, such as tristructural isotropic (TRISO) particles, within a refractory matrix (e.g., graphite or silicon carbide). The density of matrix materials for particle fuel forms is of interest for modeling fuel form strength and thermal properties and may be specified as a quality control parameter, depending on reactor design. Some of the uncertainty associated with traditional, manual approaches can be eliminated by performing x-ray computed tomography (XCT) on the fuel forms and applying image processing methods to generate a precise count of the number of particles. This also removes the need to include determination of particle count within each individual fuel form during fabrication. Unfortunately, reconstruction artifacts from high-Z uranium-bearing kernels prevent accurate measurement of individual particle volumes using this approach, so the use of mean particle mass and volume are still necessary for computation of average fuel form matrix density. This method of using XCT to count particles in individual fuel form for determination of average matrix density was applied to three archived compacts from the Advanced Gas Reactor Fuel Development and Qualification (AGR)-1 campaign, four archived compacts with uranium carbide/uranium oxide (UCO) TRISO from the AGR-2 campaign, and three archived UO 2 -TRISO compacts from the AGR-2 campaign. The resulting density values were compared with those previously reported, showing slight changes due to uncertainties in the previously used number of particles in each of these cylindrical, graphite matrix compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An IDEA of What's in the Air

The Automatic Particle Fallout Monitor (APFM) is an automated instrument that assesses real-time particle contamination levels in a facility by directly imaging, sizing, and counting contamination particles. It allows personnel to respond to particle contamination before it becomes a major problem. For NASA, the APFM improves the ability to mitigate, avoid, and explain mission-compromising incidents of contamination occurring during payload processing, launch vehicle ground processing, and potentially, during flight operations. Commercial applications are in semiconductor processing and electronics fabrication, as well as aerospace, aeronautical, and medical industries. The product could also be used to measure the air quality of hotels, apartment complexes, and corporate buildings. IDEA sold and delivered its first four units to the United Space Alliance for the Space Shuttle Program at Kennedy. NASA used the APFM in the Kennedy Space Station Processing Facility to monitor contamination levels during the assembly of International Space Station components.

Source record↗

Fabrication and testing of an airborne ice particle counter

An optical ice particle counter was proposed as a companion instrument to the GSFC laser nephelometer. By counting ice particles and total cloud particles (both ice and liquid water), these two instruments may be used to study the balance between ice and water in clouds.

Kebabian, P. L.↗

Type I polar stratospheric cloud particles - Concentration, shape, size, light extinction

Results from the flight on January 24, 1989 of the Airborne Arctic Stratospheric Experiment during which the ER-2 aircraft transitioned from unsaturated to ice saturated air at 20 km altitude are presented. Aerosol particles were sampled by wire impactors and examined for number density as a function of particle size by taking photomicrographs in a scanning electron microscope and visually sizing and counting the particles. Differences in the chemical, physical and optical properties of stratospheric aerosol between ice-saturated and nonsaturated air are described.

Pueschel, R. F.↗

Some characteristics of the solar flare event of February 16, 1984

In the morning of February 16, 1984 a solar cosmic ray event (GLE) was recorded by the world wide network of neutron monitors (NM). The counting rate vs. time profile of the Goose Bay NM (geog. lat. = 53.3 deg. N, deog. long. = 299.6 deg E) where the increase is expressed as percent of the counting rate of an equatorial sea level NM is presented. The Goose Bay NM was observed to have the maximum response to the solar particles. Its counting rate vs. time profile exhibits a rapid increase to maximum, has a large amplitude (approx. 170%) and decays rapidly to background in approx. 90 min. In Fig. 1 we also show the counting rate vs. time profile for the Tixie Bay NM (71.6 deg, 128.9 deg) which recorded an increase of only a few percent. Since the NMs at Goose Bay and Tixie Bay have asymptotic viewing directions approx. 180 deg apart in longitude, the anisotropy of the solar particle flux at Earth from these stations.

Debrunner, H.↗