Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Safe Replacement For Asbestos In Nickel/Hydrogen Cells

Polyethylene fibers and potassium titanate particles perform as well as asbestos. New material for separators of nickel-hydrogen electrochemical cells offers performance similar to that of asbestos separator material without adverse health effects. In one version, separator contains pure polyethylene fibers, and may or may not contain supplementary latices as bonding agents. In standard wet-laying papermaking process, fibers pressed into mat, then dried. Mat used as is or pressed further in hot calender stack to soften and fuse fibers at crossing points. Treatment reduces porosity and increases resistance of mat to passage of air bubbles under pressure. In alternative version, matrix of 20 to 40 percent polyethylene fibers and 60 to 80 percent potassium titanate particles formed on paper machine, then dried. It, too, can be treated by hot calendering.

Scott, William E.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic ray detector consisting of twelve gas counter trays sandwiched between two large area circular scintillation counters was flown from Palestine, Texas in November of 1972 to study the composition of primary particles 1.5 GeV/nucleon in the charge range 3 to 30. For each analyzed event, a recording was made of (1) the particle trajectory using four 20 wire proportional counter trays, (2) the energy loss in each of the solid counters, and (3) the dE/dx losses in each of the twelve gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

Cherenkov-dE/dx-range measurements on cosmic ray iron group nuclei

A balloon experiment which combined a large area plastic detector unit with electronic dE/dx-C data is presented. The correlation of the electronic data with the range data of the plastic detector stack was achieved by rotating plastic detector disks which provided in this way the passive plastic detector with an incorporated time determination. The constant flux of cosmic ray particles with charge Z greater than two was used to gauge the time resolving system. Stopping cosmic ray iron group nuclei in the energy range 400 to 700 MeV/nuc are identified using their electronic scintillator and Cherenkov signals and their etch conelengths and range data. The precise knowledge of the particle's trajectory proposes refined pathlength corrections to the electronic data.

Sermund, G.↗

Measurement of low energy cosmic rays aboard Spacelab-1

In December 1983 the first Spacelab mission was launched for a duration of 10 days. Aboard was the Kiel experiment Isotopic Stack designed for measurement of heavy cosmic ray nuclei with nuclear charge equal to or greater than 3 and energies up to some 100MeV/nuc. One part of the stack was rotated in well defined steps registered by an angle encoder to receive information on impact times of the nuclei. Using this time resolving system geomagnetically forbidden particles can be detected. The chemical composition and energy spectra of mainly CNO particles are examined using a rotated 300 microns m thick CR-39 foil beneath a fixed 100 microns m thick Kodak-Cellulose Nitrate foil. About 600 sq cm have been scanned yielding nearly 100 nuclear tracks within an energy range of approximately 8 to 30 MeV/nuc. The calibration is done by means of a postflight irradiation with 410 MeV/nuc Fe-56 at Berkeley Laboratory, California, USA. Relative abundances and energy spectra are presented.

Beaujean, R.↗

Measurement of trapped proton fluences in main stack of P0006 experiment

We have measured directional distribution and Eastward directed mission fluence of trapped protons at two different energies with plastic nuclear track detectors (CR-39 with DOP) in the main stack of the P0006 experiment on LDEF. Results show arriving directions of trapped protons have very high anisotropy with most protons arriving from the West direction. Selecting these particles we have determined the mission fluence of Eastward directed trapped protons. We found experimental fluences are slightly higher than results of the model calculations of Armstrong and Colborn.

Nefedov, N.↗

Galactic heavy cosmic rays with 5 less than E less than 130 MeV/nucleon

With stacks of Lexan and cellulose triacetate exposed outside the lunar modules on Apollo 16 and 17, a study was made of the spectra and composition of low-energy particles in interplanetary space. For the period from Apr. 16 to 23, 1972 (Apollo 16), measurements were made of the spectra of the elements 6 less than or equal to Z less than or equal to 28 at energies 40 less than or equal to E less than or equal to 150 MeV/nucleon. For the period from Dec. 11 to 13, 1972 (Apollo 17), a study was made of CNO, NeMgSi, and elements with Z greater than 16 at energies 5 less than or equal to E less than or equal to 40 MeV/nucleon. Using the abundance of charges 17 less than or equal to Z less than or equal to 25 relative to iron as a tracer, it is found that the bulk of the heavy particles in interplanetary space at E greater than 10 MeV/nucleon are of galactic rather than solar origin. The relative abundances of the various charge groups are independent of energy from about 2 GeV/nucleon down to about 30 MeV/nucleon.

Price, P. B.↗

Graphite-Fiber-Reinforced Glass-Matrix Composite

G/GI structural composite material made of graphite fibers embedded in borosilicate glass exhibit excellent strength, fracture toughness, and dimensional stability at elevated temperatures. It is made by passing graphite-fiber yarn through slurry containing suspension of fine glass particles in carrier liquid and winding on drum to produce prepegged uniaxial tape. After drying, tapes are cut into appropriate lengths and laid up in graphite die in desired stacking scheme. Stack is consolidated by hot pressing in furnace.

Prewo, K. M.↗

Structural comparison of nickel electrodes and precursor phases

A summary of previous Raman spectroscopic results and a discussion of important structural differences in the various phases of active mass and active mass precurors are presented. Raman spectra provide unique signatures for these phases, and allow one to distinguish each phase, even when the compound is amorphous to X-rays (i.e., does not scatter X-rays because of a lack of order and/or small particle size). The structural changes incurred during formation, charge and discharge, cobalt addition, and aging will be discussed and related to electrode properties. Important structural differences include NiO2 layer stacking, nonstoichiometry (especially cation-deficit nonstoichiometry), disorder, dopant content, and water content. The results indicate that optimal nickel active mass is non-close packed and nonstoichiometric. The formation process transforms precursor phases into this structure. Therefore, the precursor disorder, or lack thereof, influences this final active mass structure and the rate of formation. Aging processes induce structural change which is believed to be detrimental. The role of cobalt addition can be appreciated in terms of structures favored or stabilized by the dopant. In recent work, the in situ Raman technique to characterize the critical structural parameters was developed. An in situ method relates structure, electrochemistry, and preparation. In situ Raman spectra of cells during charge and discharge, either during cyclic voltammetry or under constant current conditions were collected. With the structure-preparation knowledge and the in situ Raman tool, it will be possible to define the structure-property-preparation relations in more detail. This instrumentation has application to a variety of electrode systems.

Cornilsen, Bahne C.↗

Lunar surface cosmic ray experiment

The galactic cosmic ray and solar flare experiment on Apollo 16 is reported. The published papers presented describe the experiment, equipment, data processing techniques, and operational history. The principle findings include: (1) The composition of heavy ions in interplanetary space at energies between approximately 30 and 130 MeV/nucleon is the same, within experimental errors. (2) The ability of a Lexan stack to determine simultaneously the energy spectra of major elements from He up to Fe in the energy interval 0.2 to 30 MeV/nucleon revealed systematic changes in the composition of solar flare particles as a function of energy. (3) Heavy ions emitted in a solar flare appear to be completely stripped of electrons, and are not in charge equilibrium at the time of acceleration and releases from the sun.

Price, P. B.↗

A comparison of two types of velocity models for the lunar crust: Smooth continuous and stepwise layered

The data from the Apollo-14 and Apollo-16 Active Seismic Experiments were reanalyzed and show that a power-law velocity variation with depth is consistent with both the traveltimes and amplitudes of the first arrivals for source-to-geophone separations up to 32m. The data were improved by removing spurious glithches, flickering and stacking. While this improved the signal-to-noise ratios, it was not possible to measure the arrivals beyond 32m. The physical evidence that the shallow lunar regolith is made up of fine particles adds weight to the 1/6-power velocity model. The 1/6-power law predicts the traveltime t(x), varies with separation, x, as t(x) = t sub 0 (x/x sub 0) to the 5/6 power and, using a first-order theory, the amplitude, A(x), varies as A(x) = A sub 0 (x/x sub 0) to the (13-m)/12, M 1; the layer-velocity model predicts t(x) = t sub 0 (x/xsub 0) and A(x) = A sub 0 (x/x sub 0) to the 2nd power.

Gangi, A. F.↗

Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

Significant absorbed dose levels exceeding 1.0 Gy day-1 have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLDs) of U.S.S.R. and U.S.A. manufacture. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

NASA Discipline Number 04-10↗

Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

Significant absorbed dose levels exceeding 1.0 Gy day(exp -1) have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLD's) made in U.S.S.R. and U.S.A. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

Watts, J. W., Jr.↗

Attempt at dust debris collection with stacked detectors (A0138-2)

The primary objective of this experiment is to investigate the feasibility of future missions of multilayer thin-film detectors acting as energy sorter to collect micrometeoroids, if not in their original shape, at least as fragments suitable for chemical analysis. It is expected that this kind of particle collector will help in solving one of the most puzzling topics in cosmic-dust studies: the mineralogical and chemical composition of the particles. This is a matter of great interest in the study of the origin and evolution of the solar system.

Mandeville, J. C.↗

Heavy ion measurement on LDEF

Heavy ions with nuclear charge Z = 6 to Z = 26 are detected in a stack of plastic track detectors. The measured energies in the range of 10-240 MeV/nuc are well below the geomagnetic cut off value of the Long Duration Exposure Facility (LDEF) orbit. The arrival directions of the low energy particles (Z = 6-26, E less than 40 MeV/nuc) are consistent with a trapped component incident in the South Atlantic Anomaly.

Jonathal, D.↗

Three-Dimensional Simulations of Electron Beams Focused by Periodic Permanent Magnets

A fully three-dimensional (3D) model of an electron beam focused by a periodic permanent magnet (PPM) stack has been developed. First, the simulation code MAFIA was used to model a PPM stack using the magnetostatic solver. The exact geometry of the magnetic focusing structure was modeled; thus, no approximations were made regarding the off-axis fields. The fields from the static solver were loaded into the 3D particle-in-cell (PIC) solver of MAFIA where fully 3D behavior of the beam was simulated in the magnetic focusing field. The PIC solver computes the time-integration of electromagnetic fields simultaneously with the time integration of the equations of motion of charged particles that move under the influence of those fields. Fields caused by those moving charges are also taken into account; thus, effects like space charge and magnetic forces between particles are fully simulated. The electron beam is simulated by a number of macro-particles. These macro-particles represent a given charge Q amounting to that of several million electrons in order to conserve computational time and memory. Particle motion is unrestricted, so particle trajectories can cross paths and move in three dimensions under the influence of 3D electric and magnetic fields. Correspondingly, there is no limit on the initial current density distribution of the electron beam, nor its density distribution at any time during the simulation. Simulation results including beam current density, percent ripple and percent transmission will be presented, and the effects current, magnetic focusing strength and thermal velocities have on beam behavior will be demonstrated using 3D movies showing the evolution of beam characteristics in time and space. Unlike typical beam optics models, this 3D model allows simulation of asymmetric designs such as non- circularly symmetric electrostatic or magnetic focusing as well as the inclusion of input/output couplers.

Kory, Carol L.↗

Cosmic heavy ion tracks in mesoscopic biological test objects

Since more than 20 years ago, when the National Academy of Sciences and the National Research Council of the U.S.A. released their report on 'HZE particle effects in manned spaced flight', it has been emphasized how difficult - if not even impossible - it is to assess their radiobiological impact on man from conventional studies where biological test organisms are stochastically exposed to 'large' fluences of heavy ions. An alternative, competing approach had been realized in the BIOSTACK experiments, where the effects of single cosmic as well as accelerator - heavy ions on individual biological test organisms could be investigated. Although presented from the beginning as the preferable approach for terrestrial investigations with accelerator heavy ions too ('The BIOSTACK as an approach to high LET radiation research'), only recently this insight is gaining more widespread recognition. In space flight experiments, additional constraints imposed by the infrastructure of the vehicle or satellite further impede such investigations. Restrictions concern the physical detector systems needed for the registration of the cosmic heavy ions' trajectories as well as the biological systems eligible as test organisms. Such optimized procedures and techniques were developed for the investigations on chromosome aberrations induced by cosmic heavy ions in cells of the stem meristem of lettuce seeds (Lactuca sativa) and for the investigation of the radiobiological response of Wolffia arriza, which is the smallest flowering (water) plant. The biological effects were studied by the coworkers of the Russian Institute of Biomedical Problems (IBMP) which in cooperation with the European Space Agency ESA organized the exposure in the Biosatellites of the Cosmos series. Since biological investigations and physical measurements of particle tracks had to be performed in laboratories widely separated, the preferred fixed contact between biological test objects and the particle detectors until the geometrical correlation between tracks and organisms has been established could not be maintained. This gave rise to half a dozen of coordinate systems for different measurements which finally had to be related to a single stack reference system.

Facius, R.↗