Search NASA⌕ Search

SEARCH · Search NASA

Results for “Passive Heat Removal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

82 records · Page 5

Energy-Efficient Direct Air Capture System for High Purity CO 2 Separation

The primary objective of this project is to demonstrate the University of Cincinnati’s direct air capture (DAC) sorbent technology in a monolithic structure installed in a passive air contactor (PAC). The modified amine-based sorbent technology provides reduced heat of desorption and resistance to thermal and oxidative degradations for robust and long-term performances and cost effective sorbent management. During the project period, additional amine modifications were developed and a U.S./PCT patent application was filed.

42 ENGINEERING↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Numerical investigation of the AP1000 response following loss-of-coolant accident using PCTRAN and CFD to support R&D of SMRs

Small Modular Reactors (SMRs) present a promising solution for the future of sustainable energy, offering advantages such as reduced waste generation, advanced passive safety features, and potential cost efficiencies. Ongoing research focuses on the design and development of SMRs, addressing challenges through numerical simulations and experimental test data. Given that many next-generation reactors are first-of-a-kind (FOK), current operational reactors serve as valuable benchmarks for understanding various thermal-hydraulic phenomena during postulated design basis accidents (DBAs), including loss-of-coolant accidents (LOCA), main steam line breaks (MSLB), and steam generator tube ruptures (SGTR). This study employs the AP1000 model Personal Computer Transient Analyzer (PCTRAN) to simulate reactor responses to small-break LOCA scenarios, specifically analyzing break sizes of 2 and 10 inches. Additionally, ANSYS FLUENT software is utilized to assess containment responses to large-break LOCAs, focusing on the quantification of decay heat removal via natural convection. Verification of the PCTRAN results is achieved using Westinghouse data, with CFD results corroborating the findings. The outcomes demonstrate strong agreement with Westinghouse data, confirming the accuracy of the simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toluene adsorption and capacity regeneration using zeolite-based monolith and activated carbon fiber felt

Common adsorbents studied to remove volatile organic compounds (VOCs) from indoor air can release previously adsorbed VOCs back into the indoor space when the adsorbent is saturated or if the VOC concentration fluctuates. A durable adsorbent with a continuous regeneration strategy could prevent this recontamination of the indoor air and reduce adsorbent disposal waste. A deeper understanding of the adsorption and desorption behavior of VOC adsorbents is needed to create an efficient regeneration strategy. This study investigated the adsorption and thermal desorption behavior of toluene on two different adsorbents, (1) a zeolite-based adsorbent and (2) an activated carbon fiber (ACF) felt. Consistent adsorption behavior across a series of toluene concentrations was used to experimentally determine effective adsorption capacity. When the cumulative adsorption between thermal regeneration steps was maintained below the maximum effective capacity with 0% breakthrough, the zeolite-based adsorbent was found to effectively minimize passive desorption. The impact of regeneration feed conditions, such as inert, oxidizing, humidified air, on thermal desorption was examined. These conditions influenced desorption of the zeolite-based adsorbent but had minimal impact on the ACF felt adsorbent, which would lead to different regeneration schedules and methods for applications in buildings' heating, ventilation, and air conditioning (HVAC) systems.

Moses-DeBusk, Melanie [Oak Ridge National Laborato↗

Development of Large Bore Rabbit Capsules in Support of BWR Cladding Irradiations in HFIR

The High Flux Isotope Reactor (HFIR) is an ideal tool for materials irradiation testing because of its intense steady-state neutron flux. Many programs take advantage of HFIR’s central flux trap for irradiation experiments using capsules, also known as rabbits, to support advanced materials development and reactor design. The facility that makes up the HFIR flux trap has recently undergone a design change that increases the HFIR primary coolant volumetric flow rate by removing restrictions in the system. As a result, the usable cross-sectional area within the facility increased, opening the door to increase the cross-sectional area of the rabbit capsules that fill the facility. This report documents a new large-diameter rabbit housing that increases the usable volume within the rabbit capsule by 22.6%. However, challenges arise with increasing the capsule size, such as establishing a new maximum capsule operating pressure and determining the thermal-hydraulic characteristics. This report addresses those challenges with previously adopted HFIR safety methods. The rupture pressure of the rabbit housings is demonstrated while verifying that capsule swelling during and after rupture will not block coolant flow. Then, a safety factor is applied to ascertain an administrative operating pressure. Additionally, the thermal-hydraulic performance of the HFIR facility filled with large-diameter rabbit capsules is shown to not violate previously determined safety criteria. Next, heat transfer coefficients are determined for use in design calculations. Furthermore, this report gives an example of internal configurations for the new, larger rabbit capsules that use relevant boiling water reactor (BWR) cladding geometry. Finally, this report documents an example thermal design performance for a rabbit capsule containing six gauge-curved tensile tube specimens. The thermal performance gives predicted temperature distributions within the capsule and shows the expected temperature of the passive thermometers for post-irradiation temperature comparisons.

99 GENERAL AND MISCELLANEOUS↗

Development of Large Bore Rabbit Capsules in Support of BWR Cladding Irradiations in HFIR

The High Flux Isotope Reactor (HFIR) is an ideal tool for materials irradiation testing because of its intense steady-state neutron flux. Many programs take advantage of HFIR’s central flux trap for irradiation experiments using capsules, also known as rabbits, to support advanced materials development and reactor design. The facility that makes up the HFIR flux trap has recently undergone a design change that increases the HFIR primary coolant volumetric flow rate by removing restrictions in the system. As a result, the usable cross-sectional area within the facility increased, opening the door to increase the cross-sectional area of the rabbit capsules that fill the facility. This report documents a new large-diameter rabbit housing that increases the usable volume within the rabbit capsule by 22.6%. However, challenges arise with increasing the capsule size, such as establishing a new maximum capsule operating pressure and determining the thermal-hydraulic characteristics. This report addresses those challenges with previously adopted HFIR safety methods. The rupture pressure of the rabbit housings is demonstrated while verifying that capsule swelling during and after rupture will not block coolant flow. Then, a safety factor is applied to ascertain an administrative operating pressure. Additionally, the thermal-hydraulic performance of the HFIR facility filled with large-diameter rabbit capsules is shown to not violate previously determined safety criteria. Next, heat transfer coefficients are determined for use in design calculations. Furthermore, this report gives an example of internal configurations for the new, larger rabbit capsules that use relevant boiling water reactor (BWR) cladding geometry. Finally, this report documents an example thermal design performance for a rabbit capsule containing six gauge-curved tensile tube specimens. The thermal performance gives predicted temperature distributions within the capsule and shows the expected temperature of the passive thermometers for post-irradiation temperature comparisons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

Optimization of Annealing for WZ-Phase Removal and Densification in Sb-Doped CdSexTe1-x Solar Cells

The impact of high temperature annealing (HTA) treatments on the performance of Sb-doped CdSeTe solar cells containing a CdSe0.25Te0.75/CdTe front stack and a vapor transport (VT) deposited CdTe:Sb absorber was studied. The HTA treatment of the thermally evaporated CdSe0.25Te0.75/CdTe front stack converts the mixed-phase film into a single zinc blende structure through recrystallization of the photo-inactive wurtzite phase. Subsequently, HTA treatment of the full device stack after vapor transport deposition of CdTe:Sb absorber promotes Se-Te intermixing, reduces voids, densifies the full stack and enhances CdTe:Sb grain growth. Comprehensive characterizations revealed that the combined HTA treatments significantly improved film crystallinity, removed the WZ phase in the front stack, enhanced full-stack densification, reduced defect densities, and enhanced carrier dynamics. With HTA treatments, the open-circuit voltage (VOC) of CdSeTe:Sb devices increased from ~ 400 mV to >= 600 mV, and when combined with optimized CdCl2 treatment, VOC reached 849 mV. The net carrier concentrations (NA-ND) of representative devices were NA-ND = 1.5 x 10^15, 1.1 x 10^15, and 3.5 x 10^14 cm-3 for the no-HTA, moderate-HTA, and optimized high-VOC conditions, respectively. Since the highest VOC corresponds to the lowest apparent NA-ND, , which is similar to a Cu-doped-only CdSeTe solar cell (NA-ND ~= 2 x 10^14 cm-3), the data indicate that improved device performance does not result from increased electrically active Sb; instead, it points to structural improvement as the dominant effect of HTA. The findings demonstrate the potential of HTA treatments to improve the structural and electrical properties of CdSeXTe1-X solar cells.

14 SOLAR ENERGY↗