The 60-MW Shuttle Interaction Heating Facility

An arc-heated wind-tunnel system described in the present paper will simulate aerodynamic heating in large-scale tests of the thermal protection system of the Shuttle Orbiter Vehicle during entry. The system provides for large-scale subsystem tests in high-enthalpy streams with boundary layer flows at high Reynolds numbers and for large test-body sizes in stagnation flows. The discussion covers the design concept of the arc-jet systems, the extensive hardware developments of the arc heater to provide reliable operation, and verification and performance measurements of the system's operating envelopes.

W Winovich↗

Grand Challenges for Small Wind: Results of the European Academy Study

While modern wind turbines have become by far the largest rotating machines on Earth with further upscaling planned for the future, a renewed interest in small wind turbines (SWTs) is fostering energy transition and smart grid development. Small machines have traditionally not received the same level of aerodynamic refinement as their larger counterparts, resulting in lower efficiency, lower capacity factors, and therefore a higher cost of energy. In an effort to reduce this gap, research programs are developing worldwide. With this background, the scope of the present study is 2-fold. In the first part of this paper, an overview of the current status of the technology is presented in terms of technical maturity, diffusion, and cost. The second part of the study proposes five grand challenges that are thought to be key to fostering the development of small wind turbine technology in the near future, i.e. (1) improving energy conversion of modern SWTs through better design and control, especially in the case of turbulent wind; (2) better predicting long-term turbine performance with limited resource measurements and proving reliability; (3) improving the economic viability of small wind energy; (4) facilitating the contribution of SWTs to the energy demand and electrical system integration; (5) fostering engagement, social acceptance, and deployment for global distributed wind markets. To tackle these challenges, a series of unknowns and gaps are first identified and discussed. Based on them, improvement areas are suggested, for which 10 key enabling actions are finally proposed.

ENGINEERING,WIND ENERGY↗

A Most Probable Point-Based Method for Reliability Analysis, Sensitivity Analysis and Design Optimization

A major step in a most probable point (MPP)-based method for reliability analysis is to determine the MPP. This is usually accomplished by using an optimization search algorithm. The optimal solutions associated with the MPP provide measurements related to safety probability. This study focuses on two commonly used approximate probability integration methods; i.e., the Reliability Index Approach (RIA) and the Performance Measurement Approach (PMA). Their reliability sensitivity equations are first derived in this paper, based on the derivatives of their respective optimal solutions. Examples are then provided to demonstrate the use of these derivatives for better reliability analysis and Reliability-Based Design Optimization (RBDO).

Hou, Gene J.-W.↗

Feasibility Study of NSLS-II Sextupole BBA Measurement

In storage ring light sources, beam-based alignment (BBA) which adjusts the BPM centers to the quadrupole magnet centers is a common practice to maintain the machine performance. For more reliable and convenient BBA process, in the design of the storage ring, BPMs are located as close as possible to the quadrupoles. The most common method is scanning the position of the beam at the BPM (equivalently at the adjacent quadrupole) and find the position where the quadrupole strength change does not give change in the closed orbit. In the simulation of the feasibility test, we choose parameters, tune, orbit and phase advance and measure their variations depending on the sextupole offsets. Also, together with the real configuration of family, we simulate the individual power supply case for the comparisons. In this note, the simulation processes and the results are presented.

43 PARTICLE ACCELERATORS↗

Performance Evaluation of Pressure Transducers for Water Impacts

The Orion Multi-Purpose Crew Vehicle is being designed for water landings. In order to benchmark the ability of engineering tools to predict water landing loads, test programs are underway for scale model and full-scale water impacts. These test programs are predicated on the reliable measurement of impact pressure histories. Tests have been performed with a variety of pressure transducers from various manufacturers. Both piezoelectric and piezoresistive devices have been tested. Effects such as thermal shock, pinching of the transducer head, and flushness of the transducer mounting have been studied. Data acquisition issues such as sampling rate and anti-aliasing filtering also have been studied. The response of pressure transducers have been compared side-by-side on an impulse test rig and on a 20-inch diameter hemisphere dropped into a pool of water. The results have identified a range of viable configurations for pressure measurement dependent on the objectives of the test program.

Vassilakos, Gregory J.↗

Interchangeable end effector tools utilized on the PFMA

An instrumented task board, used for measuring forces applied by the Protoflight Manipulator Arm (PFMA) to the task board, was fabricated and delivered to Marshall Space Flight Center. SRS Technologies phased out the existing IBM compatible data acquisition system, used with a instrumented task board, and integrated the force measuring electronic hardware in with the Macintosh II data acquisition system. The purpose of this change was to acquire all data with the same time tag, allowing easier and more accurate data reduction in addition to real-time graphics. A three-dimensional optical position sensing system for determining the location of the PFMA's end effect or in reference to the center of the instrumented task board was also designed and delivered under. An improved task board was fabricated which included an improved instrumented beam design. The modified design of the task board improved the force/torque measurement system by increasing the sensitivity, reliability, load range and ease of maintenance. A calibration panel for the optical position system was also designed and fabricated. The calibration method developed for the position sensors enhanced the performance of the sensors as well as simplified the installation and calibration procedures required. The modifications made under this effort expanded the capabilities of the task board system. The system developed determines the arm's position relative to the task board and measures the signals to the joints resulting from the operator's control signals in addition to the task board forces. The software and hardware required to calculate and record the position of the PFMA during the performance of tasks with the instrumented task board were defined, designed and delivered to MSFC. PFMA joint input signals can be measured from a breakout box to evaluate the sensitivity or response of the arm operation to control commands. The data processing system provides the capability for post processing of time-history graphics and plots of the PFMA positions, the operator's actions, and the PFMA servo reactions in addition to realtime force and position sensor data presentation.

Cody, Joe↗

Gamma-Ray Simulated Spectrum Deconvolution of a LaBr₃ 1-in. x 1-in. Scintillator for Nondestructive ATR Fuel Burnup On-Site Predictions

A deconvolution method for a LaBr₃ 1"x1" detector for nondestructive Advanced Test Reactor (ATR) fuel burnup applications was developed. The method consisted of obtaining the detector response function, applying a deconvolution algorithm to 1”x1” LaBr₃ simulated, data along with evaluating the effects that deconvolution have on nondestructively determining ATR fuel burnup. The simulated response function of the detector was obtained using MCNPX as well with experimental data. The Maximum-Likelihood Expectation Maximization (MLEM) deconvolution algorithm was selected to enhance one-isotope source-simulated and fuel- simulated spectra. The final evaluation of the study consisted of measuring the performance of the fuel burnup calibration curve for the convoluted and deconvoluted cases. The methodology was developed in order to help design a reliable, high resolution, rugged and robust detection system for the ATR fuel canal capable of collecting high performance data for model validation, along with a system that can calculate burnup and using experimental scintillator detector data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Nuclear Well Logging Techniques to Lunar Resource Assessment

The use of neutron and gamma ray measurements for the analysis of material composition has become well established in the last 40 years. Schlumberger has pioneered the use of this technology for logging wells drilled to produce oil and gas, and for this purpose has developed neutron generators that allow measurements to be made in deep (5000 m) boreholes under adverse conditions. We also make ruggedized neutron and gamma ray detector packages that can be used to make reliable measurements on the drill collar of a rotating drill string while the well is being drilled, where the conditions are severe. Modern nuclear methods used in logging measure rock formation parameters like bulk density and porosity, fluid composition, and element abundances by weight including hydrogen concentration. The measurements are made with high precision and accuracy. These devices (well logging sondes) share many of the design criteria required for remote sensing in space; they must be small, light, rugged, and able to perform reliably under adverse conditions. We see a role for the adaptation of this technology to lunar or planetary resource assessment missions.

Albats, P.↗

Analyses of Technology for Solid State Coherent Lidar

Over past few years, considerable advances have been made in the areas of the diode-pumped, eye-safe, solid state lasers and room temperature, wide bandwidth, semiconductor detectors operating in the near-infrared region. These advances have created new possibilities for the development of reliable and compact coherent lidar systems for a wide range of applications. This research effort is aimed at further developing solid state coherent lidar technology for remote sensing of atmospheric processes such as wind, turbulence and aerosol concentration. The work performed by the UAH personnel under this Delivery Order concentrated on design and analyses of laboratory experiments and measurements, and development of advanced lidar optical subsystems in support of solid state laser radar remote sensing systems which are to be designed, deployed, and used to measure atmospheric processes and constituents. Under this delivery order, a lidar breadboard system was designed and analyzed by considering the major aircraft and space operational requirements. The lidar optical system was analyzed in detail using SYNOPSIS and Code V optical design packages. The lidar optical system include a wedge scanner and the compact telescope designed by the UAH personnel. The other major optical components included in the design and analyses were: polarizing beam splitter, routing mirrors, wave plates, signal beam derotator, and lag angle compensator. This lidar system is to be used for demonstrating all the critical technologies for the development of a reliable and low-cost space-based instrument capable of measuring global wind fields. A number of laboratory experiments and measurements were performed at the NASA/MSFC Detector Characterization Facility, previously developed by the UAH personnel. These laboratory measurements include the characterization of a 2-micron InGaAs detectors suitable for use in coherent lidars and characterization of Holographic Optical Element Scanners. UAH personnel actively participated in the development of performance and operational requirements for the development of the high pulse energy transmitter laser and frequency-agile local oscillator laser, that are in-progress at NASA Langley Research Center and Jet Propulsion Laboratory.

Amzajerdian, Farzin↗

Physics of Interplanetary Dust Collection with Aerogel

This report presents the results of research undertaken to study various problems associated with hypervelocity capture of dust particles in aerogel. The primary topics investigated were the properties of shocked aerogel and the requirements for reliable capture of particles on the STARDUST mission. In particular, the viscosity of shocked aerogel has been an open question. The results presented here suggest that the viscosity of aerogel at high impact velocities is negligible, although there remains some uncertainty about lower velocities. The model adopted for viscosity treats the mixture of polymeric silica and decomposition products and finds that, for particle velocities of 6-7 km/s, the viscosity is similar to that typical of light gasses at STP. Expressions for the Hugoniot of aerogel as a function of density were also obtained from the available data. All aerogels of interest for cosmic dust collectors have very similar shock velocity-particle velocity Hugoniot curves. The strength behavior of aerogel for low-speed penetration was measured, but further work is needed to study the proper way to apply this to the issue of terminal deceleration of a dust particle. Preliminary calculations designed to maximize the penetration depths were performed to determine the required density of aerogel to reliably stop a particle in a 3 cm thickness of aerogel (the path length expected for a normal impact into the STARDUST collector). In order to stop a particle of density rho(sub p) and diameter d(sub p), the mean density of the aerogel collector should be no less than that given by the expression bar rho(sub 0) = 1.085 X 10(exp -4 )rho(sub p)d(sub p), for densities measured in g/ cu cm and the particle diameter measured in micrometers.

Anderson, William W.↗

Workload: Measurement and Management

Poster: The workload research project has as its task to survey the available literature on: (1) workload measurement techniques; and (2) the effects of workload on operator performance. The first set of findings provides practitioners with a collection of simple-to-use workload measurement techniques along with characterizations of the kinds of tasks each technique has been shown reliably address. This allows design practitioners to select and use the most appropriate techniques for the task(s) at hand. The second set of findings provides practitioners with the guidance they need to design for appropriate kinds and amounts of workload across all tasks for which the operator is responsible. This guidance helps practitioners design systems and procedures that ensure appropriate levels of engagement across all tasks, and avoid designs and procedures that result in operator boredom, complacency, loss of awareness, undue levels of stress, or skill atrophy that can result from workload that distracts operators from the tasks they perform and monitor, workload levels that are too low, too high, or too consistent or predictable. Only those articles that were peer reviewed, long standing and generally accepted in the field, and applicable to a relevant range of conditions in a select domain of interest, in analogous "extreme" environments to those in space were included. In addition, all articles were reviewed and evaluated on uni-dimensional and multi-dimensional considerations. Casner & Gore also examined the notion of thresholds and the conditions that may benefit mostly from the various methodological approaches. Other considerations included whether the tools would be suitable for guiding a requirement-related and design-related question. An initial review of over 225 articles was conducted and entered into an EndNote database. The reference list included a range of conditions in the domain of interest (subjective/objective measures), the seminal works in workload, as well as summary works

Gore, Brian Francis↗

Review and Performance Testing of the Optical Power Monitor (PMON)

The LISA mission requires a high precision optical power monitoring and control system that combines high reliability and measurement accuracy with extremely low disturbance to the core interferometric detection system. NASA is working with Avo Photonics to design and build this optical power monitor, known as PMON. The high-level design requirements take into account detector redundancy, mechanical rigidity, stability against temperature and input alignment changes, parasitic scatter and reflection artifacts, as well as low magnetic field. Gamma and Proton radiation tests have been performed on the photodiodes from a few vendors to verify radiation tolerance. Engineering development units of the PMON have been fabricated, delivered and evaluated at NASA.

Hua Jiao↗

Improved sliced velocity map imaging apparatus optimized for H photofragments

Time-sliced velocity map imaging (SVMI), a high-resolution method for measuring kinetic energy distributions of products in scattering and photodissociation reactions, is challenging to implement for atomic hydrogen products. We describe an ion optics design aimed at achieving SVMI of H fragments in a broad range of kinetic energies (KE), from a fraction of an electronvolt to a few electronvolts. In order to enable consistently thin slicing for any imaged KE range, an additional electrostatic lens is introduced in the drift region for radial magnification control without affecting temporal stretching of the ion cloud. Time slices of {approx}5 ns out of a cloud stretched to Greater-Than-Or-Slanted-Equal-To 50 ns are used. An accelerator region with variable dimensions (using multiple electrodes) is employed for better optimization of radial and temporal space focusing characteristics at each magnification level. The implemented system was successfully tested by recording images of H fragments from the photodissociation of HBr, H{sub 2}S, and the CH{sub 2}OH radical, with kinetic energies ranging from <0.4 eV to >3 eV. It demonstrated KE resolution Less-Than-Or-Equivalent-To 1%-2%, similar to that obtained in traditional velocity map imaging followed by reconstruction, and to KE resolution achieved previously in SVMI of heavier products. We expect it to perform just as well up to at least 6 eV of kinetic energy. The tests showed that numerical simulations of the electric fields and ion trajectories in the system, used for optimization of the design and operating parameters, provide an accurate and reliable description of all aspects of system performance. This offers the advantage of selecting the best operating conditions in each measurement without the need for additional calibration experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-contact direct measurement of the magnetocaloric effect in thin samples

An experimental setup, based on a non-contact temperature sensor, is proposed to directly measure the magnetocaloric effect of samples few micrometers thick. The measurement of the adiabatic temperature change of foils and ribbons is fundamental to design innovative devices based on magnetocaloric thin materials or micro-structuring bulk samples. The reliability of the proposed setup is demonstrated by comparing the measurements performed on a bulk gadolinium sample with the results obtained by an experimental setup based on a Cernox bare chip thermoresistance and by in-field differential scanning calorimetry. We show that this technique can measure the adiabatic temperature variation on gadolinium sheets as thin as 27 μm. Heat transfer simulations are added to describe the capability of the presented technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Area Silicon Sheet by EFG

Influences on ribbon quality which might be caused by various materials of construction which are used in the growth furnace were assessed. At the present level of ribbon quality, which has produced 8.5% to 9.5% efficient solar cells, no particular influence of any furnace part was detected. The experiments led to the suspicion that the general environment and the somewhat unoptimized materials handling procedures might be responsible for the current variations in ribbon quality and that, therefore, continuous work with this furnace under rather more stringent environmental conditions and operating procedures could perhaps improve materials quality to some extent. The work on the multiple furnace was continued with two multiple growth runs being performed. In these runs, the melt replenishment system performed poorly and extensive modifications to it were designed to make reliable melt feeding for five ribbon growth possible. Additional characterization techniques for wide ribbons, stress measurements, and growth dynamics experiments are reported.

Source record↗

Design of an oxygen sensor with automatic self-testing and calibration capability

Future long duration manned space missions require a reliable sensor to monitor cabin oxygen (O2) pressure. This paper presents a concept for a solid zirconia O2 sensor capable of automatic self-test and calibration without the need for consumable materials. The operation and the techniques used to verify proper performance and to calibrate the sensor are described. Coulometric measurements are used to calculate the cabin O2 pressure without comparison to any reference state; potentiometric measurements are simple and reliable. The use of independent measurements permits the verification of results obtained with either technique. The design includes fault diagnostics which takes corrective action if a fault occurs.

Cusick, Robert J.↗

Investigation on experimental techniques to detect, locate and quantify gear noise in helicopter transmissions

A robotic system to automate the detection, location, and quantification of gear noise using acoustic intensity measurement techniques has been successfully developed. Major system components fabricated under this grant include an instrumentation robot arm, a robot digital control unit and system software. A commercial, desktop computer, spectrum analyzer and two microphone probe complete the equipment required for the Robotic Acoustic Intensity Measurement System (RAIMS). Large-scale acoustic studies of gear noise in helicopter transmissions cannot be performed accurately and reliably using presently available instrumentation and techniques. Operator safety is a major concern in certain gear noise studies due to the operating environment. The man-hours needed to document a noise field in situ is another shortcoming of present techniques. RAIMS was designed to reduce the labor and hazard in collecting data and to improve the accuracy and repeatability of characterizing the acoustic field by automating the measurement process. Using RAIMS a system operator can remotely control the instrumentation robot to scan surface areas and volumes generating acoustic intensity information using the two microphone technique. Acoustic intensity studies requiring hours of scan time can be performed automatically without operator assistance. During a scan sequence, the acoustic intensity probe is positioned by the robot and acoustic intensity data is collected, processed, and stored.

Flanagan, P. M.↗

Performance and reliability of the NASA biomass production chamber

The Biomass Production Chamber (BPC) at the Kennedy Space Center is part of the Controlled Ecological Life Support System (CELSS) Breadboard Project. Plants are grown in a closed environment in an effort to quantify their contributions to the requirements for life support. Performance of this system is described. Also, in building this system, data from component and subsystem failures are being recorded. These data are used to identify problem areas in the design and implementation. The techniques used to measure the reliability will be useful in the design and construction of future CELSS. Possible methods for determining the reliability of a green plant, the primary component of CELSS, are discussed.

Fortson, R. E.↗