Search NASA⌕ Search

SEARCH · Search NASA

Results for “Personal Background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

85 records · Page 5

The NT digital micro tape recorder

The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of intensive, multi-disciplinary research and development. What follows is a discussion of the technologies that have made the NT possible: (1) NT format mechanics, (2) NT media, (3) NT circuitry and board.

Sasaki, Toshikazu↗

...And the Beats Keep Runnin Runnin (In Space)

Introduction: This case series describes the medical clearance of NASA astronauts after diagnosis of atrial fibrillation seeking to fly to the International Space Station (ISS). BACKGROUND: Atrial fibrillation is the most common sustained arrhythmia with increasing incidence with age and is associated with increased lifetime risk of stroke. Treatment may consist of pharmacologic rate control and anticoagulation. Although it is not yet known how spaceflight modifies risk of cardioembolic event or adverse treatment effects, these can have significant impact on mission and crew health for spaceflight and granting a medical waiver for flight is a complex, case-by-case consideration. Case Presentation: We reviewed all records of waivers granted by NASA for atrial fibrillation and flutter, and identified 6 cases (4 short-duration [<18 days] and 2 long-duration missions [>60 days]) where waiver was granted with subsequent spaceflight. DISCUSSION: NASA has approved astronauts with a history of atrial fibrillation or flutter for flight following an appropriate medical evaluation. With the high prevalence of atrial fibrillation in the general population, we anticipate that consideration of medical waiver will become increasingly common as commercial spaceflight grows. These cases provide a potential framework for risk assessment and management of this population, to balance potential risk modification inherent in the microgravity environment against implications to crew performance, mission success, and personal health of spaceflight participants

Space Medicine↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Health and Pharmacogenomics

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expand in duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to tailor medications for individual crewmembers and further examine appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique clinical and environmental history, genetic makeup, and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. A subset of this field is pharmacogenomics (PGX), the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on drug choice and dosing to avoid adverse events and maximize efficacy. The study goal was to identify which current space pharmacy drugs could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs on the ISS was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both astronauts’ personal medications, including supplements and over the counter drugs (n=151) contained in the ISS medical accessory kit (IMAK), and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in a total of 157 drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure (LxC). Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent ineffective treatment or impactful side effect events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost, or technical criteria and ranked from 1 (very low) to 5 (very high). An assessment of PGX reference laboratories is currently underway to evaluate sample requirements, benefit analysis (cost vs. utility of allele variant analysis), relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments (LxC 5x5 table) indicated 128 medications were in the green zone where risk is acceptable, with the remaining 29 of the medications in the yellow or red zone driven predominantly due to drug failure or safety concerns. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive preflight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve drug efficacy, and further open the door to countermeasure research. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more effective and efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing selection of the best treatment choice, and providing tailored countermeasures for individual crewmembers.

Pharmacogenomics↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Medicine and Pharmacogenomics for Human Deep Space Exploration

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expanding duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be even more essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to further tailor medications included in the spacecraft formulary and increased examination of appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of cutting-edge research and medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique factors and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. One example is the field of pharmacogenomics (PGX),the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on pharmaceutical choice and dosing to avoid adverse drug events and maximize pharmacological efficacy. The goal of this study was to evaluate which drugs in the current space pharmacy could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs onboard the International Space Station (ISS) was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both personal astronaut medications, including supplements and over the counter drugs (n=151) and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in 157 total drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure. Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent adverse events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost or technical and ranked from 1 (very low) to 5 (very high).A comprehensive assessment of commercially available PGX solutions is currently underway to evaluate specimen requirements, cost/benefit analysis (cost vs. number of alleles assessed), utility of variant analysis, relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments(LxC 5x5 table) indicated29medicationswere in the yellow or red zone driven predominantly by drug failure or safety concerns, with the remainder(n=128)of the medications in the green zone where risk is acceptable. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive pre-flight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve targeting drug efficacy and safety, and further open the door to countermeasure research exploring PGX-related allelic variants. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more cost effective and more efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing crew autonomy and providing tailored countermeasures

Alice R W Tang↗

Validation of Decompression Sickness Risk Mitigation Protocols for Planetary Spaceflight Missions

BACKGROUND: Apollo missions used a 100% O2 cabin atmosphere which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activity (EVA) on the moon. NASA’s future missions to the moon and Mars are expected to use nitrox gas mixtures of up to 34% O2, 66% N2, which will reduce flammability risk compared with Apollo, but will necessitate Oxygen prebreathe prior to EVA to reduce DCS risk to acceptable levels. Prebreathe protocols used on the space shuttle and International Space Station are validated for microgravity EVAs, but the significantly increased risk of DCS during equivalent ambulatory EVAs make these protocols inapplicable to planetary EVA. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA as a compromise that balances prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. However, this atmosphere may not be used for vehicles that do not support frequent EVA, and with commercial providers and international providers expected to provide landers, pressurized rovers, habitats, and spacesuits, different combinations of vehicle and spacesuit atmospheres are possible and will each require validated prebreathe protocols. OVERVIEW: Key components of a multi-year strategic roadmap include: 1) Establish hypobaric chamber facility capable of supporting 8-person EVA prebreathe validation tests at saturation atmospheres up to 36% O2; 2) validate an EVA physical workload simulation for use during prebreathe validation testing; 3) validate the recommended “exploration atmosphere” prebreathe protocol; 4) validate prebreathe protocols for additional atmospheric combinations that bound the most likely potential operating ranges of future vehicles and spacesuits; and 5) update DCS risk estimation models based on results of prebreathe validation studies. DISCUSSION: Details and data from completion of the first two steps of the strategic roadmap will be presented; the third step is currently underway, with pilot results provided in a companion presentation. Steps four and five will require a multi-year series of chamber tests; collaborations are being pursued.

Andrew F. J. Abercromby↗

Neocytolysis on descent from altitude: a newly recognized mechanism for the control of red cell mass

BACKGROUND: Studies of space-flight anemia have uncovered a physiologic process, neocytolysis, by which young red blood cells are selectively hemolyzed, allowing rapid adaptation when red cell mass is excessive for a new environment. OBJECTIVES: 1) To confirm that neocytolysis occurs in another situation of acute plethora-when high-altitude dwellers with polycythemia descend to sea level; and 2) to clarify the role of erythropoietin suppression. DESIGN: Prospective observational and interventional study. SETTING: Cerro de Pasco (4380 m) and Lima (sea level), Peru. PARTICIPANTS: Nine volunteers with polycythemia. INTERVENTIONS: Volunteers were transported to sea level; three received low-dose erythropoietin. MEASUREMENTS: Changes in red cell mass, hematocrit, hemoglobin concentration, reticulocyte count, ferritin level, serum erythropoietin, and enrichment of administered(13)C in heme. RESULTS: In six participants, red cell mass decreased by 7% to 10% within a few days of descent; this decrease was mirrored by a rapid increase in serum ferritin level. Reticulocyte production did not decrease, a finding that establishes a hemolytic mechanism.(13)C changes in circulating heme were consistent with hemolysis of young cells. Erythropoietin was suppressed, and administration of exogenous erythropoietin prevented the changes in red cell mass, serum ferritin level, and(13)C-heme. CONCLUSIONS: Neocytolysis and the role of erythropoietin are confirmed in persons with polycythemia who descend from high altitude. This may have implications that extend beyond space and altitude medicine to renal disease and other situations of erythropoietin suppression, hemolysis, and polycythemia.

Non-NASA Center↗

Design and implementation of scalable tape archiver

In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed cassettes, thus balancing the load of each archiver. Background migration occurs the robotics are idle. Both migration algorithms are based on access frequency and space utility of each element archiver. To normalize these parameters according to the number of drives in each element archiver, it is possible to maintain high performance even if some tape drives fail. We found that the foreground migration is efficient at reducing access response time. Beside the foreground migration, the background migration makes it possible to track the transition of spatial access locality quickly.

Nemoto, Toshihiro↗

Brief summary of the evolution of high-temperature creep-fatigue life prediction models for crack initiation

The evolution of high-temperature, creep-fatigue, life-prediction methods used for cyclic crack initiation is traced from inception in the late 1940's. The methods reviewed are material models as opposed to structural life prediction models. Material life models are used by both structural durability analysts and by material scientists. The latter use micromechanistic models as guidance to improve a material's crack initiation resistance. Nearly one hundred approaches and their variations have been proposed to date. This proliferation poses a problem in deciding which method is most appropriate for a given application. Approaches were identified as being combinations of thirteen different classifications. This review is intended to aid both developers and users of high-temperature fatigue life prediction methods by providing a background from which choices can be made. The need for high-temperature, fatigue-life prediction methods followed immediately on the heels of the development of large, costly, high-technology industrial and aerospace equipment immediately following the second world war. Major advances were made in the design and manufacture of high-temperature, high-pressure boilers and steam turbines, nuclear reactors, high-temperature forming dies, high-performance poppet valves, aeronautical gas turbine engines, reusable rocket engines, etc. These advances could no longer be accomplished simply by trial and error using the 'build-em and bust-em' approach. Development lead times were too great and costs too prohibitive to retain such an approach. Analytic assessments of anticipated performance, cost, and durability were introduced to cut costs and shorten lead times. The analytic tools were quite primitive at first and out of necessity evolved in parallel with hardware development. After forty years more descriptive, more accurate, and more efficient analytic tools are being developed. These include thermal-structural finite element and boundary element analyses, advanced constitutive stress-strain-temperature-time relations, and creep-fatigue-environmental models for crack initiation and propagation. The high-temperature durability methods that have evolved for calculating high-temperature fatigue crack initiation lives of structural engineering materials are addressed. Only a few of the methods were refined to the point of being directly useable in design. Recently, two of the methods were transcribed into computer software for use with personal computers.

Halford, Gary R.↗

TEACH (Train to Enable/Achieve Culturally Sensitive Healthcare)

Personnel from diverse ethnic and demographic backgrounds come together in both civilian and military healthcare systems, facing diagnoses that at one level are equalizers: coronary disease is coronary disease, breast cancer is breast cancer. Yet the expression of disease in individuals from different backgrounds, individual patient experience of disease as a particular illness, and interactions between patients and providers occurring in any given disease scenario, all vary enormously depending on the fortuity of the equation of "which patient happens to arrive in whose exam room." Previously, providers' absorption of lessons-learned depended on learning as an apprentice would when exposed over time to multiple populations. As a result, and because providers are often thrown into situations where communications falter through inadequate direct patient experience, diversity in medicine remains a training challenge. The questions then become: Can simulation and virtual training environments (VTEs) be deployed to short-track and standardize this sort of random-walk problem? Can we overcome the unevenness of training caused by some providers obtaining the valuable exposure to diverse populations, whereas others are left to "sink or swim"? This paper summarizes developing a computer-based VTE called TEACH (Training to Enable/Achieve Culturally Sensitive Healthcare). TEACH was developed to enhance healthcare providers' skills in delivering culturally sensitive care to African-American women with breast cancer. With an authoring system under development to ensure extensibility, TEACH allows users to role-play in clinical oncology settings with virtual characters who interact on the basis of different combinations of African American sub-cultural beliefs regarding breast cancer. The paper reports on the roll-out and evaluation of the degree to which these interactions allow providers to acquire, practice, and refine culturally appropriate communication skills and to achieve cultural and individual personalization of healthcare in their clinical practices.

Maulitz, Russell↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗

Video-Camera-Based Position-Measuring System

A prototype optoelectronic system measures the three-dimensional relative coordinates of objects of interest or of targets affixed to objects of interest in a workspace. The system includes a charge-coupled-device video camera mounted in a known position and orientation in the workspace, a frame grabber, and a personal computer running image-data-processing software. Relative to conventional optical surveying equipment, this system can be built and operated at much lower cost; however, it is less accurate. It is also much easier to operate than are conventional instrumentation systems. In addition, there is no need to establish a coordinate system through cooperative action by a team of surveyors. The system operates in real time at around 30 frames per second (limited mostly by the frame rate of the camera). It continuously tracks targets as long as they remain in the field of the camera. In this respect, it emulates more expensive, elaborate laser tracking equipment that costs of the order of 100 times as much. Unlike laser tracking equipment, this system does not pose a hazard of laser exposure. Images acquired by the camera are digitized and processed to extract all valid targets in the field of view. The three-dimensional coordinates (x, y, and z) of each target are computed from the pixel coordinates of the targets in the images to accuracy of the order of millimeters over distances of the orders of meters. The system was originally intended specifically for real-time position measurement of payload transfers from payload canisters into the payload bay of the Space Shuttle Orbiters (see Figure 1). The system may be easily adapted to other applications that involve similar coordinate-measuring requirements. Examples of such applications include manufacturing, construction, preliminary approximate land surveying, and aerial surveying. For some applications with rectangular symmetry, it is feasible and desirable to attach a target composed of black and white squares to an object of interest (see Figure 2). For other situations, where circular symmetry is more desirable, circular targets also can be created. Such a target can readily be generated and modified by use of commercially available software and printed by use of a standard office printer. All three relative coordinates (x, y, and z) of each target can be determined by processing the video image of the target. Because of the unique design of corresponding image-processing filters and targets, the vision-based position- measurement system is extremely robust and tolerant of widely varying fields of view, lighting conditions, and varying background imagery.

Lane, John↗

Stellar Occultation Observations to Constrain the Stratosphere of Uranus for Aerocapture

Background on Uranus: Voyager 2 (V2) UV stellar and solar occultations at Uranus detected a warm stratosphere and extremely hot thermosphere [1, 2], far in excess of solar irradiance [3, 4] and internal heating [5, 6]. New theories to explain similar heating at Jupiter [7] and Saturn [8] cannot be tested at Uranus due to a dearth of reliable measurements. In [9, 10], we reprocessed 26 archival Earth-based stellar occultations by Uranus (1977-1996), finding stratospheric temperatures (~200 K) warmer than the original (~100 K), but in stark tension with V2 (~300-500 K). In [10], we built a physics-based, 1-D atmospheric model (see Fig 1) that finds a nearly isothermal stratosphere and a dynamic heat sink in the lower thermosphere. Aerocapture: Aerocapture is spacecraft maneuver that uses a single deep dip to enter orbit. It could decrease cruise time and launch mass for a Uranus mission, but the greatest impediment is uncertain stratospheric densities of Uranus [11]. Aims: 1) Observe and process many high S/N Uranus stellar occultations in the next decade; 2) constrain stratospheric densities for aerocapture; 3) better understand the energy balance; 4) determine stratospheric changes since 1996. Upcoming Occultations: We will present our observing plan for the 2025 April Uranus occultation (K mag 8) and discuss the best-in-a-century 2031 event (K mag 4). We will discuss other events in the early 2030s [12] [13], predicted constraints on density, and simulations of aerocapture for UOP. We will discuss the Shadow Chaser, a small satellite concept for observing occultations from Earth orbit [12]. Conclusions: New stellar occultations can vastly improve profiles of the stratosphere of Uranus; this is critical for understanding energy circulation and constraining densities for using aerocapture on UOP. References: [1] Herbert, F. et al. (1987). JGR. [2] Stevens, M. et al. (1993). Icarus. [3] Marley, M. & McKay, C. (1999). Icarus, [4] Li, C. et al. (2018). JQRST. [5] Pearl, J. et al. (1990). Icarus. [6] Melin, H (2020). Nat Astron. [7] O’Donoghue, J. et al. (2021) Nature. [8] Mueller-Wodarg, I. et al. (2019) GRL. [9] Saunders, W. et al. (2023). PSJ. [10] Saunders, W. et al. (2024). PSJ. [11] Report of the Aerocapture Demonstration Relevance Assessment Team (2023). [12] Saunders, W. et al. (2022). P&SS. [13] French, R. & Souami, D. (2023) PSJ.

William Saunders↗