Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase contrast microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Complexions at the iron-magnetite interface

Synthesizing distinct phases and controlling crystalline defects are key concepts in materials design. These approaches are often decoupled, with the former grounded in equilibrium thermodynamics and the latter in nonequilibrium kinetics. By unifying them through defect phase diagrams, we can apply phase equilibrium models to thermodynamically evaluate defects—including dislocations, grain boundaries, and phase boundaries—establishing a theoretical framework linking material imperfections to properties. Using scanning transmission electron microscopy (STEM) with differential phase contrast (DPC) imaging, we achieve the simultaneous imaging of heavy Fe and light O atoms, precisely mapping the atomic structure and chemical composition at the iron-magnetite (Fe/Fe 3 O 4 ) interface. We identify a well-ordered two-layer interface-stabilized phase state (referred to as complexion) at the Fe[001]/Fe 3 O 4 [001] interface. Using density-functional theory (DFT), we explain the observed complexion and map out various interface-stabilized phases as a function of the O chemical potential. The formation of complexions increases interface adhesion by 20% and alters charge transfer between adjacent materials, impacting transport properties. Our findings highlight the potential of tunable defect-stabilized phase states as a degree of freedom in materials design, enabling optimized corrosion protection, catalysis, and redox-driven phase transitions, with applications in materials sustainability, efficient energy conversion, and green steel production.

36 MATERIALS SCIENCE↗

Biomechanical drivers of the evolution of butterflies and moths with a coilable proboscis

Current biomechanical models suggest that butterflies and moths use their proboscis as a drinking straw pulling nectar as a continuous liquid column. Our analyses revealed an alternative mode for fluid uptake: drinking bubble trains that help defeat drag. We combined X-ray phase-contrast imaging, optical video microscopy, micro-computed tomography, phylogenetic models of evolution and fluid mechanics models of bubble-train formation to understand the biomechanics of butterfly and moth feeding. Our models suggest that the bubble-train mechanism appeared in the early evolution of butterflies and moths with a proboscis long enough to coil. We propose that, in addition to the ability to drink a continuous column of fluid from pools, the ability to exploit fluid films by capitalizing on bubble trains would have expanded the range of available food sources, facilitating diversification of Lepidoptera.

Palaoro, Alexandre V.↗

Low-loss waveguides fabricated in BK7 glass by high repetition rate femtosecond fiber laser

For the first time femtosecond-laser writing has inscribed low-loss optical waveguides in Schott BK7 glass, a commercially important type of borosilicate widely used in optical applications. The use of a variable repetition rate laser enabled the identification of a narrow processing window at 1 MHz repetition rate with optimal waveguides exhibiting propagation losses of 0.3 dB/cm and efficient mode matching to standard optical fibers at a 1550 nm wavelength. The waveguides were characterized by complementary phase contrast and optical transmission microscopy, identifying a micrometer-sized guiding region within a larger complex structure of both positive and negative refractive index variations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Colour thresholding and objective quantification in bioimaging

Computer imaging is rapidly becoming an indispensable tool for the quantification of variables in research and medicine. Whilst its use in medicine has largely been limited to qualitative observations, imaging in applied basic sciences, medical research and biotechnology demands objective quantification of the variables in question. In black and white densitometry (0-256 levels of intensity) the separation of subtle differences between closely related hues from stains is sometimes very difficult. True-colour and real-time video microscopy analysis offer choices not previously available with monochrome systems. In this paper we demonstrate the usefulness of colour thresholding, which has so far proven indispensable for proper objective quantification of the products of histochemical reactions and/or subtle differences in tissue and cells. In addition, we provide interested, but untrained readers with basic information that may assist decisions regarding the most suitable set-up for a project under consideration. Data from projects in progress at Tulane are shown to illustrate the advantage of colour thresholding over monochrome densitometry and for objective quantification of subtle colour differences between experimental and control samples.

NASA Discipline Neuroscience↗

Martensite crystal structure in Ru-based high temperature shape memory alloys

Highlights: • A three level twinned microstructure is recognized in the β″ phase. • Wavy contrast boundaries which are typical for translation interfaces • Displacements are translations of tetragonal β′ phase, lost during transformation. • Six times bigger monoclinic cell is characterized by the disappearance of 5 translations. - Abstract: High temperature shape memory alloys RuNb and RuTa were investigated by X-ray diffraction in order to determine the structure of the low temperature β” martensite. Powder X-ray diffraction and Rietveld analysis confirm the monoclinic symmetry and allow a precise determination of the atom positions. The low temperature microstructure is the result of a martensitic transformation from a tetragonal β′ martensite. The analysis of how it is controlled by the space groups of the two phases and by their relative orientation is performed by transmission electron microscopy. A three level twinned microstructure is recognized in the β” phase. The investigation at the smallest scale twins reveals the presence of wavy contrast boundaries which are typical for translation interfaces. High resolution transmission electron microscopy images, accompanied by phase contrast imaging analysis, have been used to determine the translation vectors associated to the interfaces. These displacements are the translations of the tetragonal β′ phase which are lost during the transformation. The combination of X-ray diffraction and transmission electron microscopy investigation allows the suggestion of a global distortion mechanism that explains the atomic displacements in the β” form.

36 MATERIALS SCIENCE↗

Spatial Mapping of Electrostatic Fields in 2D Heterostructures

In situ electron microscopy is an effective tool for understanding the mechanisms driving novel phenomena in 2D structures. However, due to practical challenges, it is difficult to address these technologically relevant 2D heterostructures with electron microscopy. Here, we use the differential phase contrast (DPC) imaging technique to build a methodology for probing local electrostatic fields during electrical operation with nanoscale spatial resolution in such materials. We find that, by combining a traditional DPC setup with a high-pass filter, we can largely eliminate electric fluctuations emanating from short-range atomic potentials. Using a method based on this filtering algorithm, a priori electric field expectations can be directly compared with experimentally derived values to readily identify inhomogeneities and potentially problematic regions. Furthermore, we use this platform to analyze the electric field and charge density distribution across layers of hBN and MoS 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

TEM phase contrast imaging with image plane phase grating

Transmission microscopy imaging systems include a mask and/or other modulator situated to encode image beams, e.g., by deflecting the image beam with respect to the mask and/or sensor. The beam is modulated/masked either before or after transmission through a sample to induce a spatially and/or temporally encoded signal by modifying any of the beam/image components including the phase/coherence, intensity, or position of the beam at the sensor. For example, a mask can be placed/translated through the beam so that several masked beams are received by a sensor during a single sensor integration time. Images associated with multiple mask displacements are then used to reconstruct a video sequence using a compressive sensing method. Another example of masked modulation involves a mechanism for phase-retrieval, whereby the beam is modulated by a set of different masks in the image plane and each masked image is recorded in the diffraction plane.

47 OTHER INSTRUMENTATION↗

MnSe phase segregation during heteroepitaxy of Mn doped Ga{sub 2}Se{sub 3} on Si(001).

Heteroepitaxial thin films of Mn-doped Ga{sub 2}Se{sub 3} are grown by molecular beam epitaxy on Si(001):As. Mn-doped films are laminar for the first 1-2 nm, after which oriented islands with flat tops are observed by scanning tunneling microscopy. In contrast with the bulk phase diagram, which predicts MnGa{sub 2}Se{sub 4} precipitates, the precipitates are identified by bond length measurements from extended x-ray absorption fine structure as rocksalt MnSe. This difference is attributed to superior lattice matching of MnSe to the substrate, and an epitaxial relationship between the MnSe and Si substrate is inferred.

36 MATERIALS SCIENCE↗

Real-Time Interactive 4D-STEM Phase-Contrast Imaging From Electron Event Representation Data: Less computation with the right representation

The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.

4D-STEM↗

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Diamond Beamline I13L for Imaging and Coherence

I13L is the first long beamline at Diamond dedicated to imaging and coherence. Two independent branches will operate in the energy range of 6-30 keV with spatial resolution on the micro- to nano-lengthscale. The Imaging branch is dedicated to imaging and tomography with In-line phase contrast and full-field microscopy on the micron to nano-length scale. Ultimate resolution will be achieved on the Coherence branch at I13L with imaging techniques in the reciprocal space. The experimental stations will be located about 250 m from the source, taking advantage of the coherence properties of the source. The beamline has some outstanding features such as the mini-beta layout of the storage ring's straight section. The optical layout is optimized for beam stability and high optical quality to preserve the coherent radiation. In the experimental stations several methods will be available, starting for the first user with in-line phase contrast imaging on the imaging branch and Coherent X-ray Diffraction (CXRD) on the coherence branch.

43 PARTICLE ACCELERATORS↗

Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction

Coherent x-ray diffraction microscopy is a lensless phase-contrast imaging technique with high image contrast. Although electron tomography allows intensive study of the three-dimensional structure of cellular organelles, it has inherent difficulty with thick objects. X rays have the unique benefit of allowing noninvasive analysis of thicker objects and high spatial resolution. We observed an unstained human chromosome using coherent x-ray diffraction. The reconstructed images in two or three dimensions show an axial structure, which has not been observed under unstained conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unexpected bismuth concentration profiles in metal-organic vapor phase epitaxy-grown Ga(As{sub 1−x}Bi{sub x})/GaAs superlattices revealed by Z-contrast scanning transmission electron microscopy imaging

A set of GaAs{sub 1−x}Bi{sub x}/GaAs multilayer quantum-well structures was deposited by metal-organic vapor phase epitaxy at 390 °C and 420 °C. The precursor fluxes were introduced with the intent of growing discrete and compositionally uniform GaAs{sub 1−x}Bi{sub x} well and GaAs barrier layers in the epitaxial films. High-resolution high-angle annular-dark-field (or “Z-contrast”) scanning transmission electron microscopy imaging revealed concentration profiles that were periodic in the growth direction, but far more complicated in shape than the intended square wave. The observed composition profiles could explain various reports of physical properties measurements that suggest compositional inhomogeneity in GaAs{sub 1−x}Bi{sub x} alloys as they currently are grown.

36 MATERIALS SCIENCE↗

Atomically sharp domain walls in an antiferromagnet

The interest in understanding scaling limits of magnetic textures such as domain walls spans the entire field of magnetism from its physical fundamentals to applications in information technologies. Here, we explore antiferromagnetic CuMnAs in which imaging by x-ray photoemission reveals the presence of magnetic textures down to nanoscale, reaching the detection limit of this established microscopy in antiferromagnets. We achieve atomic resolution by using differential phase-contrast imaging within aberration-corrected scanning transmission electron microscopy. We identify abrupt domain walls in the antiferromagnetic film corresponding to the Néel order reversal between two neighboring atomic planes. Our work stimulates research of magnetic textures at the ultimate atomic scale and sheds light on electrical and ultrafast optical antiferromagnetic devices with magnetic field–insensitive neuromorphic functionalities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical and Calorimetric Studies of Cholesterol-Rich Filamentous, Helical Ribbon and Crystal Microstructures

Formation of biological self-assemblies at all scales is a focus of studies in fields ranging from biology to physics to biomimetics. Understanding the physico-chemical properties of these self-assemblies may lead to the design of bio-inspired structures and technological applications. Here we examine self-assembled filamentous, helical ribbon, and crystal microstructures formed in chemically defined lipid concentrate (CDLC), a model system for cholesterol crystallization in gallbladder bile. CDLC consists of cholesterol, bilayer-forming amphiphiles, micelle-forming amphiphiles, and water. Phase contrast and differential interference contrast (DIC) microscopy indicate the presence of three microstructure types in all samples studied, and allow for an investigation of the structures' unique geometries. Additionally, confocal microscopy is used for qualitative assessment of surface and internal composition. To complement optical observations, calorimetric (differential-scanning and modulation) experiments, provide the basis for an in-depth understanding of collective and individual thermal behavior. Observed ''transition'' features indicate clustering and ''straightening'' of helical ribbons into short, increasingly thickening, filaments that dissolve with increasing temperature. These results suggest that all microstructures formed in CDLC may coexist in a metastable chemical equilibrium. Further investigation of the CDLC thermal profile should uncover the process of cholesterol crystallization as well as the unique design and function of microstructures formed in this system.

60 APPLIED LIFE SCIENCES↗

Charge Recombination, Transport Dynamics, and Interfacial Effects in Organic Solar Cells

The need for renewable sources of energy is well known. Conversion of sunlight to electricity using solar cells is one of the most important opportunities for creating renewable energy sources. The research carried out under DE-FG02-08ER46535 focused on the science and technology of “Plastic” solar cells comprised of organic (i.e. carbon based) semiconductors. The Bulk Heterojunction concept involves a phase separated blend of two organic semiconductors each with dimensions in the nano-meter length scale --- one a material that functions as a donor for electrons and the other a material that functions as an acceptor for electrons. The nano-scale inter-penetrating network concept for “Plastic” solar cells was created at UC Santa Barbara. A simple measure of the impact of this concept can be obtained from a Google search which gives 244,000 “hits” for the Bulk Heterojunction solar cell. Research funded through this program focused on four major areas: 1. Interfacial effects in organic photovoltaics, 2. Charge transfer and photogeneration of mobile charge carriers in organic photovoltaics, 3. Transport and recombination of the photogenerated charge carriers in organic photovoltaics, 4. Synthesis of novel organic semiconducting polymers and semiconducting small molecules, including conjugated polyelectrolytes. Following the discovery of ultrafast charge transfer at UC Santa Barbara in 1992, the nano-organic (Bulk Heterojunction) concept was formulated. The need for a morphology comprising two interpenetrating bicontinuous networks was clear: one network to carry the photogenerated electrons (negative charge) to the cathode and one network to carry the photo-generated holes (positive charge) to the anode. This remarkable self-assembled network morphology has now been established using Transmission electron Microscopy (TEM) either in the Phase Contrast mode or via TEM-Tomography. The steps involved in delivering power from a solar cell to an external circuit are the following: • Photo-excitation of the donor (or the acceptor). • Charge transfer with holes in the donor domain and electrons in the acceptor domain. • Sweep-out to electrodes prior to recombination by the internal electric field. • Energy delivered to the external circuit. Each of these four steps was studied in detail using a wide variety of organic semiconductors with different molecular structures. This UC Santa Barbara group was the first to clarify the origin and the mechanism involved in the ultrafast charge transfer process. The ultrafast charge transfer (time scale approximately 100 times faster than the first step in the photo-synthesis of green plants) is the fundamental reason for the potential for high power conversion efficiency of sunlight to electricity from plastic solar cells. The UCSB group was the first to emphasize, clarify and demonstrate the need for sweep-out to electrodes prior to recombination by the internal electric field. The UCSB group was the first to synthesize small molecule organic semiconductors capable of high power conversion efficiencies. The results of this research were published in high impact peer-reviewed journals. Our published papers (40 in number) provide answers to fundamental questions that have been heavily discussed and debated in the field of Bulk Heterojunction Solar Cells; scientific questions that must be resolved before this technology can be ready for commercialization in large scale for production of renewable energy. Of the forty publications listed, nineteen were co-authored by two or more of the PIs, consistent with the multi-investigator approach described in the original proposal. The specific advantages of this “plastic” solar cell technology are the following: a. Manufacturing by low-cost printing technology using soluble organic semiconductors; this approach can be implemented in large scale by roll-to-roll printing on plastic substrates. b. Low energy cost in manufacturing; all steps carried out at room temperature (approx. a factor of ten less than the use of Silicon which requires high temperature processing). c. Low carbon footprint d. Lightweight, flexible and rugged Because of the resolution of many scientific issues, a significant fraction of which were addressed in the research results of DE-FG02-08ER46535, the power conversion efficiencies are improving at an ever increasing rate. During the funding period of DE-FG02-08ER46535, the power conversion efficiencies of plastic solar cells improved from just a few per cent to values greater than 11% with contributions from our group and from researchers all over the world.

14 SOLAR ENERGY↗

Hard X-ray Phase-Contrast Tomographic Nanoimaging

Synchrotron-based full-field tomographic microscopy established itself as a tool for noninvasive investigations. Many beamlines worldwide routinely achieve micrometer spatial resolution while the isotropic 100-nm barrier is reached and trespassed only by few instruments, mainly in the soft x-ray regime. We present an x-ray, full-field microscope with tomographic capabilities operating at 10 keV and with a 3D isotropic resolution of 144 nm recently installed at the TOMCAT beamline of the Swiss Light Source. Custom optical components, including a beam-shaping condenser and phase-shifting dot arrays, were used to obtain an ideal, aperture-matched sample illumination and very sensitive phase-contrast imaging. The instrument has been successfully used for the nondestructive, volumetric investigation of single, unstained cells.

43 PARTICLE ACCELERATORS↗

Three-Phase 3D Reconstruction of a LiCoO2 Cathode via FIB-SEM Tomography

Abstract Three-phase three-dimensional (3D) microstructural reconstructions of lithium-ion battery electrodes are critical input for 3D simulations of electrode lithiation/delithiation, which provide a detailed understanding of battery operation. In this report, 3D images of a LiCoO 2 electrode are achieved using focused ion beam-scanning electron microscopy (FIB-SEM), with clear contrast among the three phases: LiCoO 2 particles, carbonaceous phases (carbon and binder) and the electrolyte space. The good contrast was achieved by utilizing an improved FIB-SEM sample preparation method that combined infiltration of the electrolyte space with a low-viscosity silicone resin and triple ion-beam polishing. Morphological parameters quantified include phase volume fraction, surface area, feature size distribution, connectivity, and tortuosity. Electrolyte tortuosity was determined using two different geometric calculations that were in good agreement. The electrolyte tortuosity distribution versus position within the electrode was found to be highly inhomogeneous; this will lead to inhomogeneous electrode lithiation/delithiation at high C-rates that could potentially cause battery degradation.

Liu, Zhao (ORCID:0000000303702406)↗