Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photodiode arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Radiation effects studies for the high-resolution spectrograph

The generation and collection of charge carriers created during the passage of energetic protons through a silicon photodiode array are modeled. Pulse height distributions of noise charge collected during exposure of a digicon type diode array to 21 and 75 MeV protons were obtained. The magnitude of charge collected by a diode from each proton event is determined not only by diffusion, but by statistical considerations involving the ionization process itself. Utilizing analytical solutions to the diffusion equation for transport of minority carriers, together with the Vavilov theory of energy loss fluctuations in thin absorbers, simulations of the pulse height spectra which follow the experimental distributions fairly well are presented and an estimate for the minority carrier diffusion length L sub d is provided.

Smith, L. C.↗

Simultaneous multiple-point velocity measurements using laser-induced iodine fluorescence

A technique is demonstrated for measuring velocity at multiple locations in a plane of a gaseous flowfield using Doppler-shifted absorption with fluorescence detection from iodine molecules, excited by a sheet of tunable single-axial-mode argon-ion laser radiation at 514.5 nm. Measurements were made simultaneously at 10,000 points in an iodine-seeded supersonic flow field with a 100 x 100 element photodiode array camera and were found to agree well with a numerical solution for the velocity field. The accuracy with which a component of velocity can be measured is limited, in the current approach, by the iodine linewidth to about 5 m/sec.

Mcdaniel, J. C.↗

Laser-induced fluorescence technique for velocity field measurements in subsonic gas flows

A nonintrusive optical technique is reported for multiple-point velocity measurements in subsonic flows. The technique is based on the detection of fluorescence from a Doppler-shifted absorption line of seeded iodine molecules excited at a laser frequency fixed in the wing of the line. Counterpropagating laser sheets are used to illuminate the flow, in the present case a nitrogen round jet, thereby eliminating the need for an unshifted reference signal. The fluorescence is detected simultaneously at 10,000 points in a plane of the flow using a 100 x 100 element photodiode-array camera. The velocity at each point is computed from four successive camera frames, each recorded with a different beam direction. The measured mean velocities between 5 and 50 m/sec agree well with data from the literature.

Hiller, B.↗

Observations of spectroscopic binaries at ultraviolet and red wavelengths

The use of IUE-satellite and ground-based-Reticon observations for the study of spectroscopic binaries is examined, and sample data from the Reticon are presented. IUE radial-velocity determinations with uncertainties as low as 2-5 km/sec should be possible for binaries with early-type secondary components, using UV spectral lines where contamination by the later-type primary is reduced. The Reticon solid-state photodiode-array detector has been used at the coudefocus of the 2.7-m telescope at McDonald Observatory for observation of complex multiple systems in the 400-950-nm range with a quantum efficiency of 40-80 percent and resolution of 20-30 pm at 440 pm/mm. The fundamental parameters of 15 systems observed with this apparatus are listed in a table, and two sample spectra are shown.

Fekel, F. C., Jr.↗

CARS system for turbulent flame measurements

Simultaneous nitrogen number density and rotational-vibrational temperatures were measured in a turbulent diffusion flame with a Coherent Anti-Stokes Raman Scattering (CARS) instrument. The fuel jet was diluted with nitrogen (20 percent by volume) to allow temperature measurements across the entire jet mixing region. These measurements were compared with fluid dynamics computations. The CARS system incorporated a neodymium YAG laser, an intensified silicon photodiode array detector, and unique dynamic range enhancement methods. Theoretical calculations were based on a parabolic Navier-Stokes computer code. The comparison of these techniques will aid their development in the study of complex flowfields.

Antcliff, R. R.↗

Characterization of CNRS Fizeau wedge laser tuner

A fringe detection and measurement system was constructed for use with the CNRS Fizeau wedge laser tuner, consisting of three circuit boards. The first board is a standard Reticon RC-100 B motherboard which is used to provide the timing, video processing, and housekeeping functions required by the Reticon RL-512 G photodiode array used in the system. The sampled and held video signal from the motherboard is processed by a second, custom fabricated circuit board which contains a high speed fringe detection and locating circuit. This board includes a dc level discriminator type fringe detector, a counter circuit to determine fringe center, a pulsed laser triggering circuit, and a control circuit to operate the shutter for the He-Ne reference laser beam. The fringe center information is supplied to the third board, a commercial single board computer, which governs the data collection process and interprets the results.

Source record↗

Velocity visualization in gaseous flows

Techniques are established for visualizing velocity in gaseous flows. Two approaches are considered, both of which are capable of yielding velocity simultaneously at a large number of flowfield locations, thereby providing images of velocity. The first technique employs a laser to mark specific fluid elements and a camera to track their subsequent motion. Marking is done by laser-induced phosphorescence of biacetyl, added as a tracer species in a flow of N2, or by laser-induced formation of sulfur particulates in SF6-H2-N2 mixtures. The second technique is based on the Doppler effect, and uses an intensified photodiode array camera and a planar form of laser-induced fluorescence to detect 2-d velocities of I2 (in I2-N2 mixtures) via Doppler-shifted absorption of narrow-linewidth laser radiation at 514.5 nm.

Hanson, R. K.↗

Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

Roberts, W. T.↗

Fizeau wavemeter for pulsed laser wavelength measurement

A Fizeau wavelength meter optimized for use with pulsed laser sources has been developed and characterized which demonstrates a CW resolution better than 2 parts in 10 to the 7th and a pulsed resolution better than 1 part in 10 to the 6th. The static optical design is based on a Fizeau wedge interferometer, which together with spatial filtering and collimating optics is used to produce a pattern of parallel fringes which is imaged on a linear photodiode array and analyzed by a minicomputer. A series of CW and pulsed measurements of various narrowband laser sources are described, and particular difficulties involved in pulsed laser measurements with the wavemeter are examined.

Morris, M. B.↗

Velocity visualization in gas flows using laser-induced phosphorescence of biacetyl

Visualization of a two-dimensional velocity field by means of laser-induced phosphorescence is demonstrated in a nitrogen flow at room temperature. A pulsed dye laser is used to excite seeded biacetyl molecules along a line in the flow. Two successive exposures of the emitted phosphorescence are recorded with an intensified 100 x 100 element photodiode array camera. Velocities are determined from the distance traveled in the time interval between exposures. Important factors in connection with the phosphorescence of biacetyl are discussed.

Hiller, B.↗

Operation of a microchannel plate counting system in a mass spectrometer

A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

Murphy, D. M.↗

The Hopkins ultraviolet telescope

The Shuttle is scheduled to carry the Hopkins UV Telescope (HUT) aloft in 1986. HUT will be one of three telescopes on the mission and will be sensitive to the 450-1800 A interval. Its primary goals will be observations of Halley's Comet, the planets, distant galaxies and quasars. It will be controlled by Spacelab personnel and features a 0.9 m primary mirror, a spectrograph on the focal plane, and an Si intensified image television camera for on-line image monitoring. The main component of the spectrograph will be a 1024 channel self-scanning Reticon photodiode array coupled by optic fibers to the microchannel detector plates. HUT is presently undergoing qualification testing.

Davidsen, A. F.↗

Two-frequency laser-induced fluorescence technique for rapid velocity-field measurements in gas flows

A technique is presented for measurements of two-dimensional velocity fields in gas flows. The single-mode frequency of an argon-ion laser is fixed in the wing of an absorption line of iodine molecules that are seeded at low level in the flow of interest. The emitted fluorescence is detected with an image-intensified 100 x 100 photodiode-array camera. two pairs of counterpropagating laser sheets sequentially probe the flow to determine two velocity components. The frequency in one pair is shifted with respect to the other by an acousto-optic modulator. This two-frequency scheme eliminates the need to determine the slope of the line externally and offers the potential for combined pressure and velocity-field measurements.

Hiller, B.↗

Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

Roberts, B.↗

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

Near-infrared spectroscopy of planetary nebulae: How strong is the H2 emission?

In an effort to understand the systematics of the H2 emission from planetary nebulae, a program of near-infared spectroscopy using the University of Texas infrared reticon spectrometer was started. This instrument has a 1x32 element InSb photodiode array as a detector. All of the observations reported were made on the McDonald Observatory 2.7 m telescope, with spectra resolving power lambda/delta lambda = 600. The spectral coverage allows the measurement strengths of Brackett gamma He I 2.113 microns, HE II 2.189 microns and the v = 1=0 S(1) line of H2 at 2.122 microns. One of the most important advantages of this instrument is that we are able to resolve H2 from the adjacent He I line. Most previous observations of planetaries have been made at spectral resolving powers of about 100, which blend these lines. The contribution of the He I line has generally been dismissed as being unimportant, but we show that this may not be valid. Our higher resolving power also improves the line-to-continuum contrast; in some cases, the continuum is the limiting factor in detecting faint lines.

Dinerstein, H. L.↗

Optical strain measurement system development, phase 1

A laser speckle, differential strain measurement system was built and tested for future applications in hostile environments. One dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system was used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 16 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

Melting of troilite at high pressure in a diamond cell by laser heating

A system for measuring melting temperatures at high pressures is described. The sample is heated with radiation from a YAG laser. The beam is reflected downward through a microscope objective, through the upper diamond anvil, and focused onto the sample. Hense, intense heating is produced only at the sample and not within the diamond anvils. A vidicon system is used to observe the sample during heating. Incandescent light from the heated sample passes back through the objective lens into a grating spectrometer. The spectrum of the incandescent light is received by the photodiode array and stored in the multichannel analyzer. These data can then be transferred to floppy disk for analysis. A curve fitting program is used to compare the spectra with standard blackbody curves and to determine the temperature. Pressure is measured by the ruby fluorescence method. The system was used to study the melting behavior of natural troilite (FeS).

Bassett, William A.↗